The application of spray towers for CO2 capture is a development trend in recent years. However, most of the previous jobs were conducted in a cylindrical tower by using a single spray nozzle, whose configuration and ...The application of spray towers for CO2 capture is a development trend in recent years. However, most of the previous jobs were conducted in a cylindrical tower by using a single spray nozzle, whose configuration and performance is not good enough for industrial application. To solve this problem, the present work proposed a diameter-varying spray tower and a new spray mode of dual-nozzle opposed impinging spray to enhance the heat and mass transfer of CO2 absorption process. Experiments were performed to investigate the mass transfer performance (in terms of the CO2 removal rate (η) and the overall mass transfer coefficient (KGae)) of the improved spray tower under various operating conditions. Experimental results showed that the liquid to gas ratio and mole ratio of MEA to C02 are major factors, which affect the absorption performance and the maximums of η and KGae that are 94.0% and 0.574 kmol. m^-3·h^-1·kPa^-1, respectively, under the experimental conditions. Furthermore, new correlations to predict the mass transfer coefficient of the proposed spray tower are developed in various CO2 concentrations with a Pearson Correlation Coefficient over 90%.展开更多
Many researchers have studied single and double effect absorption cycles based on first and second lows of thermodynamics But so far the relation of different parameters inside these cycles to the second law of thermo...Many researchers have studied single and double effect absorption cycles based on first and second lows of thermodynamics But so far the relation of different parameters inside these cycles to the second law of thermodynamics in boiler and cooling tower has not been investigated. In this paper, a system comprised of a series flow double effect water-Lithium bromide absorption chiller, a boiler and a cooling tower is studied based on the first and second laws of thermodynamics, and also exergy analysis is investigated. For this purpose, mass and energy conservation laws governing the system are written, and coefficient of performance of the system, exergy destruction (loss) of each component and exergy efficiency have been calculated.展开更多
基金Supported by the National Natural Science Foundation of China(51276141)the Natural Science Basic Research Plan in Shaanxi Province of China(2015JQ5192)"Fundamental Research Funds for the Central Universities"
文摘The application of spray towers for CO2 capture is a development trend in recent years. However, most of the previous jobs were conducted in a cylindrical tower by using a single spray nozzle, whose configuration and performance is not good enough for industrial application. To solve this problem, the present work proposed a diameter-varying spray tower and a new spray mode of dual-nozzle opposed impinging spray to enhance the heat and mass transfer of CO2 absorption process. Experiments were performed to investigate the mass transfer performance (in terms of the CO2 removal rate (η) and the overall mass transfer coefficient (KGae)) of the improved spray tower under various operating conditions. Experimental results showed that the liquid to gas ratio and mole ratio of MEA to C02 are major factors, which affect the absorption performance and the maximums of η and KGae that are 94.0% and 0.574 kmol. m^-3·h^-1·kPa^-1, respectively, under the experimental conditions. Furthermore, new correlations to predict the mass transfer coefficient of the proposed spray tower are developed in various CO2 concentrations with a Pearson Correlation Coefficient over 90%.
文摘Many researchers have studied single and double effect absorption cycles based on first and second lows of thermodynamics But so far the relation of different parameters inside these cycles to the second law of thermodynamics in boiler and cooling tower has not been investigated. In this paper, a system comprised of a series flow double effect water-Lithium bromide absorption chiller, a boiler and a cooling tower is studied based on the first and second laws of thermodynamics, and also exergy analysis is investigated. For this purpose, mass and energy conservation laws governing the system are written, and coefficient of performance of the system, exergy destruction (loss) of each component and exergy efficiency have been calculated.