AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four ...AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI) was performed. RESULTS: There were no significant differences in visual acuity (P〉0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (t-=-0.634, P=-0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC), nucleus opacity (NO), cortex (C) and posterior lens capsular (P) (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=-0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.50.8 before and ld, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P〈0.01) between the two groups. CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method.展开更多
This paper deals with the surface analysis of spherical polymeric optical micro-resonators in order to correlate surface defects with optical characteristics. Atomic force microscopy was used on structures to determin...This paper deals with the surface analysis of spherical polymeric optical micro-resonators in order to correlate surface defects with optical characteristics. Atomic force microscopy was used on structures to determine surface quality, which is the main origin of optical scattering losses. Surface morphologies were numerically treated to enable a relevant investigation on surface parameters such as root mean square (RMS) roughness (30.1 +/- 3.0 nm) or correlation length (few microns) necessary to express optical quality factors. A statistical analysis was conducted for calibration of these parameters as a function of cavities’ diameter. Results are in perfect agreement with spectral analyses performed in parallel on others structures. This comparison highlights the main role of scattering losses on quality factor origin.展开更多
AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system.METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D ...AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system.METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of Acry Sof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes,T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), residual refractive cylinder and intraocular lens(IOL) axis rotation.Objective optical quality were measured using optical quality analysis system(OQAS Ⅱ, Visiometrics, Spain),included the cutoff frequency of modulation transfer function(MTFcutoff), objective scattering index(OSI),Strehl ratio, optical quality analysis system value(OV)100%, OV 20% and OV 9% [the optical quality analysis system(OQAS) values at contrasts of 100%, 20%, and 9%].RESULTS: At 3mo postoperative, the mean UDVA and CDVA was 0.18 ±0.11 and 0.07 ±0.08 log MAR; the mean residual refractive cylinder was 0.50 ±0.29 D; the mean toric IOL axis rotation was 3.62 ±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV9% were 22.862 ±5.584, 1.80 ±0.84, 0.155 ±0.038, 0.76 ±0.18,0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%,OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different(P 】0.05), except the residual refractive cylinder(P 【0.05).CONCLUSION: The optical quality analysis system was useful for characterizing the optical quality of Acry Sof toric IOL implantation. Implantation of an Acry Sof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery.展开更多
Multi-modality medical image fusion has more and more important applications in medical image analysis and understanding. In this paper, we develop and apply a multi-resolution method based on wavelet pyramid to fuse ...Multi-modality medical image fusion has more and more important applications in medical image analysis and understanding. In this paper, we develop and apply a multi-resolution method based on wavelet pyramid to fuse medical images from different modalities such as PET-MRI and CT-MRI. In particular, we evaluate the different fusion results when applying different selection rules and obtain optimum combination of fusion parameters.展开更多
AIM:To evaluate the effect of low-degree astigmatism on objective visual quality through the Optical Quality Analysis System(OQAS).METHODS:This study enrolled 46 participants(aged 23 to 30y,90 eyes)with normal or corr...AIM:To evaluate the effect of low-degree astigmatism on objective visual quality through the Optical Quality Analysis System(OQAS).METHODS:This study enrolled 46 participants(aged 23 to 30y,90 eyes)with normal or corrected-to-normal vision.The cylindrical lenses(0,0.5,0.75,1.0,and 1.25 D)were placed at the axial direction(180°,45°,90°,and 135°)in front of the eyes with the best correction to form 16 types of regular low-degree astigmatism.OQAS was used to detect the objective visual quality,recorded as the objective scattering index(OSI),OQAS values at contrasts of 100%,20%,and 9%predictive visual acuity(OV100%,OV20%,and OV9%),modulation transfer function cut-off(MTFcut-off)and Strehl ratio(SR).The mixed effect linear model was used to compare objective visual quality differences between groups and examine associations between astigmatic magnitude and objective visual quality parameters.RESULTS:Apparent negative relationships between the magnitude of low astigmatism and objective visual quality were observed.The increase of OSI per degree of astigmatism at 180°,45°,90°,and 135°axis were 0.38(95%CI:0.35,0.42),0.50(95%CI:0.46,0.53),0.49(95%CI:0.45,0.54)and 0.37(95%CI:0.34,0.41),respectively.The decrease of MTFcut-off per degree of astigmatism at 180°,45°,90°,and 135°axis were-10.30(95%CI:-11.43,-9.16),-12.73(95%CI:-13.62,-11.86),-12.75(95%CI:-13.79,-11.70),and-9.97(95%CI:-10.92,-9.03),respectively.At the same astigmatism degree,OSI at 45°and 90°axis were higher than that at 0°and 135°axis,while MTFcut-off were lower.CONCLUSION:Low astigmatism of only 0.50 D can significantly reduce the objective visual quality.展开更多
The water quality testing principle by surface plasmon resonance(SPR)is introduced.Using the scanning mode angular spectral testing and the CCD angular spectral testing,a kind of highresolution,wide-range,and portable...The water quality testing principle by surface plasmon resonance(SPR)is introduced.Using the scanning mode angular spectral testing and the CCD angular spectral testing,a kind of highresolution,wide-range,and portable optical waveguide SPR angular spectral testing system is studied,the method of improving the testing accuracy is discussed,and a long-life surface plasmon optical waveguide transducer is also proposed.Utilizing the SPR testing system,we contrastively tack some test for several sorts of solution,the results presented that significant differences of SPR peaks observed in different sorts of liquid,which indicated the effectiveness of SPR technology used in water quality testing and analysis.展开更多
Increasing attention has been paid to the deterioration of air quality in China during the past decade.This study presents the spatiotemporal variations of aerosol concentration across China during 2000–2016 using ae...Increasing attention has been paid to the deterioration of air quality in China during the past decade.This study presents the spatiotemporal variations of aerosol concentration across China during 2000–2016 using aerosol optical depth(AOD)from the atmospheric product of Moderate Resolution Imaging Spectroradiometer.Percentile thresholds are applied to define AOD days with different loadings.Temporally,aerosol concentration has increased since 2000 and reached the highest level in 2011;then it has declined from 2011 to 2016.Seasonally,aerosol concentration is the highest in summer and the lowest in winter.Spatially,North China and Sichuan Basin are featured by high aerosol concentration with increasing trends in North China and decreasing trends in Sichuan Basin.North,Southeast and Southwest China have been through increasing days with low AOD loading;however,Northeast China has experienced increasing days with high AOD loading.It is likely that air quality influenced by aerosols has notably improved over North China in spring and summer,over Southwest and Southeast China in autumn,but has degraded over Northeast China in autumn.展开更多
文摘AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI) was performed. RESULTS: There were no significant differences in visual acuity (P〉0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (t-=-0.634, P=-0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC), nucleus opacity (NO), cortex (C) and posterior lens capsular (P) (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=-0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.50.8 before and ld, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P〈0.01) between the two groups. CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method.
文摘This paper deals with the surface analysis of spherical polymeric optical micro-resonators in order to correlate surface defects with optical characteristics. Atomic force microscopy was used on structures to determine surface quality, which is the main origin of optical scattering losses. Surface morphologies were numerically treated to enable a relevant investigation on surface parameters such as root mean square (RMS) roughness (30.1 +/- 3.0 nm) or correlation length (few microns) necessary to express optical quality factors. A statistical analysis was conducted for calibration of these parameters as a function of cavities’ diameter. Results are in perfect agreement with spectral analyses performed in parallel on others structures. This comparison highlights the main role of scattering losses on quality factor origin.
文摘AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system.METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of Acry Sof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes,T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), residual refractive cylinder and intraocular lens(IOL) axis rotation.Objective optical quality were measured using optical quality analysis system(OQAS Ⅱ, Visiometrics, Spain),included the cutoff frequency of modulation transfer function(MTFcutoff), objective scattering index(OSI),Strehl ratio, optical quality analysis system value(OV)100%, OV 20% and OV 9% [the optical quality analysis system(OQAS) values at contrasts of 100%, 20%, and 9%].RESULTS: At 3mo postoperative, the mean UDVA and CDVA was 0.18 ±0.11 and 0.07 ±0.08 log MAR; the mean residual refractive cylinder was 0.50 ±0.29 D; the mean toric IOL axis rotation was 3.62 ±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV9% were 22.862 ±5.584, 1.80 ±0.84, 0.155 ±0.038, 0.76 ±0.18,0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%,OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different(P 】0.05), except the residual refractive cylinder(P 【0.05).CONCLUSION: The optical quality analysis system was useful for characterizing the optical quality of Acry Sof toric IOL implantation. Implantation of an Acry Sof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery.
基金the National Natural Science Foundation of China (No. 19675005).
文摘Multi-modality medical image fusion has more and more important applications in medical image analysis and understanding. In this paper, we develop and apply a multi-resolution method based on wavelet pyramid to fuse medical images from different modalities such as PET-MRI and CT-MRI. In particular, we evaluate the different fusion results when applying different selection rules and obtain optimum combination of fusion parameters.
文摘AIM:To evaluate the effect of low-degree astigmatism on objective visual quality through the Optical Quality Analysis System(OQAS).METHODS:This study enrolled 46 participants(aged 23 to 30y,90 eyes)with normal or corrected-to-normal vision.The cylindrical lenses(0,0.5,0.75,1.0,and 1.25 D)were placed at the axial direction(180°,45°,90°,and 135°)in front of the eyes with the best correction to form 16 types of regular low-degree astigmatism.OQAS was used to detect the objective visual quality,recorded as the objective scattering index(OSI),OQAS values at contrasts of 100%,20%,and 9%predictive visual acuity(OV100%,OV20%,and OV9%),modulation transfer function cut-off(MTFcut-off)and Strehl ratio(SR).The mixed effect linear model was used to compare objective visual quality differences between groups and examine associations between astigmatic magnitude and objective visual quality parameters.RESULTS:Apparent negative relationships between the magnitude of low astigmatism and objective visual quality were observed.The increase of OSI per degree of astigmatism at 180°,45°,90°,and 135°axis were 0.38(95%CI:0.35,0.42),0.50(95%CI:0.46,0.53),0.49(95%CI:0.45,0.54)and 0.37(95%CI:0.34,0.41),respectively.The decrease of MTFcut-off per degree of astigmatism at 180°,45°,90°,and 135°axis were-10.30(95%CI:-11.43,-9.16),-12.73(95%CI:-13.62,-11.86),-12.75(95%CI:-13.79,-11.70),and-9.97(95%CI:-10.92,-9.03),respectively.At the same astigmatism degree,OSI at 45°and 90°axis were higher than that at 0°and 135°axis,while MTFcut-off were lower.CONCLUSION:Low astigmatism of only 0.50 D can significantly reduce the objective visual quality.
文摘The water quality testing principle by surface plasmon resonance(SPR)is introduced.Using the scanning mode angular spectral testing and the CCD angular spectral testing,a kind of highresolution,wide-range,and portable optical waveguide SPR angular spectral testing system is studied,the method of improving the testing accuracy is discussed,and a long-life surface plasmon optical waveguide transducer is also proposed.Utilizing the SPR testing system,we contrastively tack some test for several sorts of solution,the results presented that significant differences of SPR peaks observed in different sorts of liquid,which indicated the effectiveness of SPR technology used in water quality testing and analysis.
基金supported by a Natural Sciences and Engineering Research Council of Canada(NSERC)Discovery Grant and Ontario Trillium Scholarship.
文摘Increasing attention has been paid to the deterioration of air quality in China during the past decade.This study presents the spatiotemporal variations of aerosol concentration across China during 2000–2016 using aerosol optical depth(AOD)from the atmospheric product of Moderate Resolution Imaging Spectroradiometer.Percentile thresholds are applied to define AOD days with different loadings.Temporally,aerosol concentration has increased since 2000 and reached the highest level in 2011;then it has declined from 2011 to 2016.Seasonally,aerosol concentration is the highest in summer and the lowest in winter.Spatially,North China and Sichuan Basin are featured by high aerosol concentration with increasing trends in North China and decreasing trends in Sichuan Basin.North,Southeast and Southwest China have been through increasing days with low AOD loading;however,Northeast China has experienced increasing days with high AOD loading.It is likely that air quality influenced by aerosols has notably improved over North China in spring and summer,over Southwest and Southeast China in autumn,but has degraded over Northeast China in autumn.