In this study, a novel phoswich detector for beta–gamma coincidence detection is designed. Unlike the triple crystal phoswich detector designed by researchers at the University of Missouri, Columbia, this phoswich de...In this study, a novel phoswich detector for beta–gamma coincidence detection is designed. Unlike the triple crystal phoswich detector designed by researchers at the University of Missouri, Columbia, this phoswich detector is of the semi-well type, so it has a higher detection efficiency. The detector consists of BC-400 and NaI:Tl with decay time constants of 2.4 and 230 ns, respectively.The BC-400 scintillator detects beta particles, and the Na I:Tl cell is used for gamma detection. Geant4 simulations of this phoswich detector find that a 2-mm-thick BC-400 scintillator can absorb nearly all of the beta particles whose energies are below 700 keV. Further, for a 2.00-cmthick NaI:Tl crystal, the gamma source peak efficiency for photons ranges from a maximum of nearly 90% at 30 keV to 10% at 1 MeV. The self-absorption effect is also discussed in this paper in order to determine the carrier gas' s influence.展开更多
In Wireless Body Area Networks(WBANs)with respect to health care,sensors are positioned inside the body of an individual to transfer sensed data to a central station periodically.The great challenges posed to healthca...In Wireless Body Area Networks(WBANs)with respect to health care,sensors are positioned inside the body of an individual to transfer sensed data to a central station periodically.The great challenges posed to healthcare WBANs are the black hole and sink hole attacks.Data from deployed sensor nodes are attracted by sink hole or black hole nodes while grabbing the shortest path.Identifying this issue is quite a challenging task as a small variation in medicine intake may result in a severe illness.This work proposes a hybrid detection framework for attacks by applying a Proportional Coinciding Score(PCS)and an MK-Means algorithm,which is a well-known machine learning technique used to raise attack detection accuracy and decrease computational difficulties while giving treatments for heartache and respiratory issues.First,the gathered training data feature count is reduced through data pre-processing in the PCS.Second,the pre-processed features are sent to the MK-Means algorithm for training the data and promoting classification.Third,certain attack detection measures given by the intrusion detection system,such as the number of data packages trans-received,are identified by the MK-Means algorithm.This study demonstrates that the MK-Means framework yields a high detection accuracy with a low packet loss rate,low communication overhead,and reduced end-to-end delay in the network and improves the accuracy of biomedical data.展开更多
Positron emission tomography (PET) using 18F-fluorodeoxyglucose (FDG) has not been widely used in China for expensive cost ($1200). Dual-head coincidence single photon emission computed tomography (DHC-SPECT) ...Positron emission tomography (PET) using 18F-fluorodeoxyglucose (FDG) has not been widely used in China for expensive cost ($1200). Dual-head coincidence single photon emission computed tomography (DHC-SPECT) can depict many of the lesions depicted with a PET scanner in the lungs, which is used in place of PET-CT for discriminating malignant from benign pulmonary nodules in many studies. However, DHC-SPECT has inevitable false-negative results because the sensitivity for small lesions less than 2.0 cm is limited, and has high false-positive rate for active inflammatory nodules. Furthermore,DHC-SPECT also has a considerably higher cost ($300 in China) than other imaging examination.展开更多
基金supported by the National Natural Science Foundation of China(Nos.11205108,11475121,and 11575145)the Excellent Youth Fund of Sichuan University(No.2016SCU04A13)
文摘In this study, a novel phoswich detector for beta–gamma coincidence detection is designed. Unlike the triple crystal phoswich detector designed by researchers at the University of Missouri, Columbia, this phoswich detector is of the semi-well type, so it has a higher detection efficiency. The detector consists of BC-400 and NaI:Tl with decay time constants of 2.4 and 230 ns, respectively.The BC-400 scintillator detects beta particles, and the Na I:Tl cell is used for gamma detection. Geant4 simulations of this phoswich detector find that a 2-mm-thick BC-400 scintillator can absorb nearly all of the beta particles whose energies are below 700 keV. Further, for a 2.00-cmthick NaI:Tl crystal, the gamma source peak efficiency for photons ranges from a maximum of nearly 90% at 30 keV to 10% at 1 MeV. The self-absorption effect is also discussed in this paper in order to determine the carrier gas' s influence.
基金funded by Stefan cel Mare University of Suceava,Romania.
文摘In Wireless Body Area Networks(WBANs)with respect to health care,sensors are positioned inside the body of an individual to transfer sensed data to a central station periodically.The great challenges posed to healthcare WBANs are the black hole and sink hole attacks.Data from deployed sensor nodes are attracted by sink hole or black hole nodes while grabbing the shortest path.Identifying this issue is quite a challenging task as a small variation in medicine intake may result in a severe illness.This work proposes a hybrid detection framework for attacks by applying a Proportional Coinciding Score(PCS)and an MK-Means algorithm,which is a well-known machine learning technique used to raise attack detection accuracy and decrease computational difficulties while giving treatments for heartache and respiratory issues.First,the gathered training data feature count is reduced through data pre-processing in the PCS.Second,the pre-processed features are sent to the MK-Means algorithm for training the data and promoting classification.Third,certain attack detection measures given by the intrusion detection system,such as the number of data packages trans-received,are identified by the MK-Means algorithm.This study demonstrates that the MK-Means framework yields a high detection accuracy with a low packet loss rate,low communication overhead,and reduced end-to-end delay in the network and improves the accuracy of biomedical data.
文摘Positron emission tomography (PET) using 18F-fluorodeoxyglucose (FDG) has not been widely used in China for expensive cost ($1200). Dual-head coincidence single photon emission computed tomography (DHC-SPECT) can depict many of the lesions depicted with a PET scanner in the lungs, which is used in place of PET-CT for discriminating malignant from benign pulmonary nodules in many studies. However, DHC-SPECT has inevitable false-negative results because the sensitivity for small lesions less than 2.0 cm is limited, and has high false-positive rate for active inflammatory nodules. Furthermore,DHC-SPECT also has a considerably higher cost ($300 in China) than other imaging examination.