期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Photonic-assisted approach for instantaneous microwave frequency measurement with tunable range by using Mach-Zehnder interferometers 被引量:5
1
作者 王大鹏 徐坤 +3 位作者 戴键 吴钟乐 纪越峰 林金桐 《Chinese Optics Letters》 SCIE EI CAS CSCD 2013年第2期12-14,共3页
A novel photonic-assisted approach to microwave frequency measurement is proposed and experimentally demonstrated. The proposed scheme is based on the frequency-to-power mapping with different transmis- sion responses... A novel photonic-assisted approach to microwave frequency measurement is proposed and experimentally demonstrated. The proposed scheme is based on the frequency-to-power mapping with different transmis- sion responses. A polarizer is used in one output branch of a phase modulator to simultaneously implement phase modulation and intensity modulation. Owing to the complementary nature of the transmission re- sponses and the Mach-Zehnder interferometers (MZIs), this scheme theoretically provides high resolution and tunable measurement range. The measurement errors in the experimental results can be kept within 0.2 GHz over a freauencv ranee from 0.1 to 5.3 GHz. 展开更多
关键词 Photonic-assisted approach for instantaneous microwave frequency measurement with tunable range by using mach-zehnder interferometers ACF
原文传递
Design of Mach-Zehnder Interferometer and Ring Resonator for Biochemical Sensing 被引量:2
2
作者 Dedi IRAWAN Toto SAKTIOTO +1 位作者 Jalil ALI Preecha YUPAPIN 《Photonic Sensors》 SCIE EI CAS CSCD 2015年第1期12-18,共7页
We proposed a compact design of an optical biochemical sensor based on the Mach-Zehnder interferometer (MZI), which was coupled by a ring resonator (RR) as a sensing tool. The sensor sensitivity has been determine... We proposed a compact design of an optical biochemical sensor based on the Mach-Zehnder interferometer (MZI), which was coupled by a ring resonator (RR) as a sensing tool. The sensor sensitivity has been determined by power difference at the output ports. The sensor enhancement has been optimized by numerically evaluating the geometrical parameters of the MZ! and RR. A great sensor sensitivity depicted by Fano resonance characteristic has been demonstrated as a function of the round trip phase in the range of 4×10^-4 - 4×10^-4, which was changed by the presence of the sample solution in the sensing area. This optimum sensitivity has been obtained for the values of two coupling coefficients of the MZI k1 =k2 =0.5/mm and the coupling coefficient between the MZI arm and RR KR = 0.5/ram. Furthermore, a good profile of sensitivity exchange has been exhibited by inducing the direct current voltage to the coupling region of k R. Finally, the output power transmission of the ring-coupled arm was depicted as a function of tunable k R. 展开更多
关键词 mach-zehnder interferometer ring resonator biochemical sensor tunable sensitivity Fano resonance
原文传递