Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography corona...Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.展开更多
Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acqu...Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv,P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique.展开更多
Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic,pulmonary and coronary circulation.We present a ...Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic,pulmonary and coronary circulation.We present a preterm newborn female patient with type 2 truncusarteriosus,left superior vena cava and aberrant subclavian artery diagnosed with low dose dual-source cardiac computed tomography(CT).We discuss that low dose dual-source cardiac CT has more advantages than other imaging methods and it is an important modality for assessment of patients with conotruncal anomalies such as truncusarteriosus.展开更多
Objective:Coronary artery anatomical variations and anomalies are an important topic due to their potential clinical manifestations.This study aims to investigate the prevalence of coronary artery anatomical variation...Objective:Coronary artery anatomical variations and anomalies are an important topic due to their potential clinical manifestations.This study aims to investigate the prevalence of coronary artery anatomical variations and anomalies in symptomatic patients with coronary computed tomography angiography(CCTA).Methods:This is a retrospective study that included all symptomatic patients who had CCTA in a tertiary care hospital in Saudi Arabia during a period of seven years.Results:The total number of included patients was 507(60%males)with a mean age of 57.4 years.Approximately 41%had luminal stenoses,averaging 49.7%.The total num-ber of patients with coronary anatomical variations(CAV)and coronary artery anomalies(CAA)was 217(43%).CAV prevalence was 26%,which included 14%non-right coronary dominance,5%short left main coronary artery(LMCA),and 7%division variations(trifurcation and quadrifurcarion)of the LMCA.The prevalence of CAA was 29%,which included 5%origin anomalies,22%myocardial bridge,and 2%course anomalies.Conclusions:A high prevalence of coronary artery anatomic variations and anomalies in symptomatic patients is reported in this study.Systematic reviews,meta-analyses,reporting guidelines,and unified definitions and classifications of cor-onary variations and anomalies are lacking in the literature,presenting potential opportunities for future research and publications.展开更多
Objective: On the premise that the image quality meets the requirements of clinical diagnosis, we explored the methods to reduce the radiation dose of coronary artery imaging with Dual-Source CT (DSCT). Methods: We ra...Objective: On the premise that the image quality meets the requirements of clinical diagnosis, we explored the methods to reduce the radiation dose of coronary artery imaging with Dual-Source CT (DSCT). Methods: We randomly selected 200 patients with coronary heat disease (BIM 0.05). The average image noise in group A is (41.76 ± 7.98) HU, in group B the average image noise is (43.97 ± 3.88) HU, the dif- ference between the two groups was not statistically significant (P>0.05). The average CTDIvol of group A and B were (20.63 ± 2.24) mGy, (38.11 ± 10.69) mGy, respectively, then P <0.01. The average DLP of group A and B are (235.75 ± 28.64) mGycm and (492.59 ± 125.49) mGycm respectively, then P <0.01, the dif- ference of radiation dose had statistical significance (P<0.05). Conclusions: For coronary artery imaging with DSCT the heart electric pulse (AUTO) regulation technology can meet the diagnostic requirements and effectively reduce the radiation dose.展开更多
Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scannin...Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scanning mode. Methods: The imaging data of 100 patients who underwent CT coronary angiography (CCTA) using Siemens force CT retrospective gated triggering spiral scan (RES-SPIRAL), adaptive prospective gated triggering sequence scan (SEQ) and prospective coarse pitch scan (TurboFlash) retrospectively was collected. The image quality was evaluated by objective and subjective methods. The effective radiation dose of patients was compared and analyzed, and the indications of the three scanning modes were analyzed. The application value of dual-source CT TurboFlash coarse pitch scanning in coronary artery imaging was evaluated. Results: The results showed that the left main coronary artery, the right coronary artery and their tertiary branches could be clearly displayed in the three groups of images: the left anterior descending branch, the left circumflex branch, and their three-level branches. There was no statistical difference in subjective image quality among the three groups of pictures (P > 0.05). There was no statistical difference in objective evaluation indexes, such as CT value, SNR, CNR and Noise among the three groups (P > 0.05). The patient radiation dose results showed that the effective radiation dose ED of RES-SPIRA scan was (9.22 ± 1.33) mSv. The dose of SEQ was (2.88 ± 2.47) mSv, and the dose of TurboFlash was (0.51 ± 0.16) mSv. There was significant difference in comparison of the three groups (P 0.05). RES-spiral scanning had the highest radiation dose and TurboFlash coarse pitch scanning (TurboFlash) had the lowest radiation dose. Conclusion: TurboFlash coarse pitch scanning is low in dosage, fast in speed and wide in adaptability. It is especially suitable for the elderly, children, coma and other patients who cannot cooperate with breath-holding examination, as well as for the screening and examination of coronary artery diseases in asymptomatic population. Undoubtedly, it is a worthy method of heart coronary artery examination.展开更多
Objectives To investigate the morphologic characteristics of intramural hematoma(IMH)on CT angiography(CTA),and evaluate the possible correlation of serum C-reactive protein(CRP)with morphologic characteristics of IMH...Objectives To investigate the morphologic characteristics of intramural hematoma(IMH)on CT angiography(CTA),and evaluate the possible correlation of serum C-reactive protein(CRP)with morphologic characteristics of IMH.Material and Methods Forty-two patients who were initially diagnosed as IMH by aortic CTA and also had serum CRP examination on the same day of CTA were enrolled in this retrospective study,including 30 males and 12 females,with the mean age of 61±14 years old.The volumetric CT data were retrospectively processed and analyzed on post-processing workstation.Based on the thickness of IMH and the length-area curve,the crosssectional area of true lumen and total vessel were measured,the hematoma-vessel ratio(HVR)was calculated.Imaging characteristics were compared between patients who had pathological elevated CRP(>0.8 mg/dl)and those did not.Spearman correlation analyses of CRP level and morphological characteristics of IMH were performed,and the receiver operating characteristic(ROC)curve was used to evaluate the diagnostic validity of CRP.Results Of all 42 IMH patients,the mean serum CRP was 3.94±4.71 mg/dl,and the mean HVR was 46.7%±14.2%.HVR in patients with elevated CRP was significantly higher than those with normal CRP(49.7%±15.0%vs.40.7%±10.5%,P=0.030).HVR was mildly correlated with CRP in all patients(r=0.48,P<0.001).CRP levels differed neither between patients with Stanford type A and B(P=0.207),nor between patients with and without intimal disruption(P=0.230).To discriminate HVR>47%(the mean value),the area under curve(AUC)were 0.700(95%CI:0.535-0.865)for CRP at a cutoff point of 3.55 mg/dl,with a sensitivity of 54.5%and a specificity of 90.0%.Conclusion CRP was mildly correlated with the severity of cross-sectional hematoma area of IMH,but not with Stanford types and the presence of intimal disruption.展开更多
目的探讨基于冠状动脉CT血管成像(CCTA)的人工智能(AI)诊断系统及CT无创血流储备分数(CT-FFR)在评估高海拔地区冠状动脉临界病变结构及功能学中的应用价值。方法前瞻性收集2022年1月~2023年10月青海大学附属医院冠心病临界病变患者164例...目的探讨基于冠状动脉CT血管成像(CCTA)的人工智能(AI)诊断系统及CT无创血流储备分数(CT-FFR)在评估高海拔地区冠状动脉临界病变结构及功能学中的应用价值。方法前瞻性收集2022年1月~2023年10月青海大学附属医院冠心病临界病变患者164例,按居住地海拔进行分组,其中2000~3000m为A组(n=83),3000m以上为B组(n=81),再将两组患者按冠脉狭窄程度细分为50%~60%亚组(n=84)和61%~70%亚组(n=80)。将患者冠状动脉CT血管成像数据导入AI辅助诊断及CT-FFR测量系统,以冠脉造影及冠脉传统血流储备分数(FFR)为金标准,分别评价AI及CT-FFR在高海拔地区冠脉临界病变诊断中的应用。结果以FFR为金标准,CT-FFR与FFR的一致性为83.75%。B组钙化斑块、易损斑块高于A组(P=0.037、0.020);B组冠状动脉多支病变、61%~70%狭窄程度发生率均高于A组(P<0.05);A组、B组在61%~70%亚组钙化斑块、易损斑块发生率均高于50%~60%亚组(P<0.05)。B组CT-FFR值低于A组(0.76±0.04 vs 0.88±0.05,P<0.01);A、B两组在61%~70%亚组CT-FFR值≤0.80、<0.70的发生率高于50%~60%亚组(P<0.05)。结论AI诊断系统及CT-FFR对评估高海拔地区冠状动脉临界病变的结构特征及血流动力学改变的结果与冠脉造影、FFR一致性高,具有较高的诊断敏感度和特异度。展开更多
基金Supported by the Ministry of Science and Technology of Inner Mongolia, China (20110504)
文摘Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.
基金Supported by the Ministry of Science and Technology of Inner Mongolia, China (20110504)
文摘Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv,P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique.
文摘Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic,pulmonary and coronary circulation.We present a preterm newborn female patient with type 2 truncusarteriosus,left superior vena cava and aberrant subclavian artery diagnosed with low dose dual-source cardiac computed tomography(CT).We discuss that low dose dual-source cardiac CT has more advantages than other imaging methods and it is an important modality for assessment of patients with conotruncal anomalies such as truncusarteriosus.
文摘Objective:Coronary artery anatomical variations and anomalies are an important topic due to their potential clinical manifestations.This study aims to investigate the prevalence of coronary artery anatomical variations and anomalies in symptomatic patients with coronary computed tomography angiography(CCTA).Methods:This is a retrospective study that included all symptomatic patients who had CCTA in a tertiary care hospital in Saudi Arabia during a period of seven years.Results:The total number of included patients was 507(60%males)with a mean age of 57.4 years.Approximately 41%had luminal stenoses,averaging 49.7%.The total num-ber of patients with coronary anatomical variations(CAV)and coronary artery anomalies(CAA)was 217(43%).CAV prevalence was 26%,which included 14%non-right coronary dominance,5%short left main coronary artery(LMCA),and 7%division variations(trifurcation and quadrifurcarion)of the LMCA.The prevalence of CAA was 29%,which included 5%origin anomalies,22%myocardial bridge,and 2%course anomalies.Conclusions:A high prevalence of coronary artery anatomic variations and anomalies in symptomatic patients is reported in this study.Systematic reviews,meta-analyses,reporting guidelines,and unified definitions and classifications of cor-onary variations and anomalies are lacking in the literature,presenting potential opportunities for future research and publications.
文摘Objective: On the premise that the image quality meets the requirements of clinical diagnosis, we explored the methods to reduce the radiation dose of coronary artery imaging with Dual-Source CT (DSCT). Methods: We randomly selected 200 patients with coronary heat disease (BIM 0.05). The average image noise in group A is (41.76 ± 7.98) HU, in group B the average image noise is (43.97 ± 3.88) HU, the dif- ference between the two groups was not statistically significant (P>0.05). The average CTDIvol of group A and B were (20.63 ± 2.24) mGy, (38.11 ± 10.69) mGy, respectively, then P <0.01. The average DLP of group A and B are (235.75 ± 28.64) mGycm and (492.59 ± 125.49) mGycm respectively, then P <0.01, the dif- ference of radiation dose had statistical significance (P<0.05). Conclusions: For coronary artery imaging with DSCT the heart electric pulse (AUTO) regulation technology can meet the diagnostic requirements and effectively reduce the radiation dose.
文摘Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scanning mode. Methods: The imaging data of 100 patients who underwent CT coronary angiography (CCTA) using Siemens force CT retrospective gated triggering spiral scan (RES-SPIRAL), adaptive prospective gated triggering sequence scan (SEQ) and prospective coarse pitch scan (TurboFlash) retrospectively was collected. The image quality was evaluated by objective and subjective methods. The effective radiation dose of patients was compared and analyzed, and the indications of the three scanning modes were analyzed. The application value of dual-source CT TurboFlash coarse pitch scanning in coronary artery imaging was evaluated. Results: The results showed that the left main coronary artery, the right coronary artery and their tertiary branches could be clearly displayed in the three groups of images: the left anterior descending branch, the left circumflex branch, and their three-level branches. There was no statistical difference in subjective image quality among the three groups of pictures (P > 0.05). There was no statistical difference in objective evaluation indexes, such as CT value, SNR, CNR and Noise among the three groups (P > 0.05). The patient radiation dose results showed that the effective radiation dose ED of RES-SPIRA scan was (9.22 ± 1.33) mSv. The dose of SEQ was (2.88 ± 2.47) mSv, and the dose of TurboFlash was (0.51 ± 0.16) mSv. There was significant difference in comparison of the three groups (P 0.05). RES-spiral scanning had the highest radiation dose and TurboFlash coarse pitch scanning (TurboFlash) had the lowest radiation dose. Conclusion: TurboFlash coarse pitch scanning is low in dosage, fast in speed and wide in adaptability. It is especially suitable for the elderly, children, coma and other patients who cannot cooperate with breath-holding examination, as well as for the screening and examination of coronary artery diseases in asymptomatic population. Undoubtedly, it is a worthy method of heart coronary artery examination.
基金Fund supported by the Clinical Research Supporting Fund of Chinese PLA General Hospital(2016FC-TSYS-1039)~~
文摘Objectives To investigate the morphologic characteristics of intramural hematoma(IMH)on CT angiography(CTA),and evaluate the possible correlation of serum C-reactive protein(CRP)with morphologic characteristics of IMH.Material and Methods Forty-two patients who were initially diagnosed as IMH by aortic CTA and also had serum CRP examination on the same day of CTA were enrolled in this retrospective study,including 30 males and 12 females,with the mean age of 61±14 years old.The volumetric CT data were retrospectively processed and analyzed on post-processing workstation.Based on the thickness of IMH and the length-area curve,the crosssectional area of true lumen and total vessel were measured,the hematoma-vessel ratio(HVR)was calculated.Imaging characteristics were compared between patients who had pathological elevated CRP(>0.8 mg/dl)and those did not.Spearman correlation analyses of CRP level and morphological characteristics of IMH were performed,and the receiver operating characteristic(ROC)curve was used to evaluate the diagnostic validity of CRP.Results Of all 42 IMH patients,the mean serum CRP was 3.94±4.71 mg/dl,and the mean HVR was 46.7%±14.2%.HVR in patients with elevated CRP was significantly higher than those with normal CRP(49.7%±15.0%vs.40.7%±10.5%,P=0.030).HVR was mildly correlated with CRP in all patients(r=0.48,P<0.001).CRP levels differed neither between patients with Stanford type A and B(P=0.207),nor between patients with and without intimal disruption(P=0.230).To discriminate HVR>47%(the mean value),the area under curve(AUC)were 0.700(95%CI:0.535-0.865)for CRP at a cutoff point of 3.55 mg/dl,with a sensitivity of 54.5%and a specificity of 90.0%.Conclusion CRP was mildly correlated with the severity of cross-sectional hematoma area of IMH,but not with Stanford types and the presence of intimal disruption.
文摘目的探讨基于冠状动脉CT血管成像(CCTA)的人工智能(AI)诊断系统及CT无创血流储备分数(CT-FFR)在评估高海拔地区冠状动脉临界病变结构及功能学中的应用价值。方法前瞻性收集2022年1月~2023年10月青海大学附属医院冠心病临界病变患者164例,按居住地海拔进行分组,其中2000~3000m为A组(n=83),3000m以上为B组(n=81),再将两组患者按冠脉狭窄程度细分为50%~60%亚组(n=84)和61%~70%亚组(n=80)。将患者冠状动脉CT血管成像数据导入AI辅助诊断及CT-FFR测量系统,以冠脉造影及冠脉传统血流储备分数(FFR)为金标准,分别评价AI及CT-FFR在高海拔地区冠脉临界病变诊断中的应用。结果以FFR为金标准,CT-FFR与FFR的一致性为83.75%。B组钙化斑块、易损斑块高于A组(P=0.037、0.020);B组冠状动脉多支病变、61%~70%狭窄程度发生率均高于A组(P<0.05);A组、B组在61%~70%亚组钙化斑块、易损斑块发生率均高于50%~60%亚组(P<0.05)。B组CT-FFR值低于A组(0.76±0.04 vs 0.88±0.05,P<0.01);A、B两组在61%~70%亚组CT-FFR值≤0.80、<0.70的发生率高于50%~60%亚组(P<0.05)。结论AI诊断系统及CT-FFR对评估高海拔地区冠状动脉临界病变的结构特征及血流动力学改变的结果与冠脉造影、FFR一致性高,具有较高的诊断敏感度和特异度。