Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography corona...Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.展开更多
Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scannin...Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scanning mode. Methods: The imaging data of 100 patients who underwent CT coronary angiography (CCTA) using Siemens force CT retrospective gated triggering spiral scan (RES-SPIRAL), adaptive prospective gated triggering sequence scan (SEQ) and prospective coarse pitch scan (TurboFlash) retrospectively was collected. The image quality was evaluated by objective and subjective methods. The effective radiation dose of patients was compared and analyzed, and the indications of the three scanning modes were analyzed. The application value of dual-source CT TurboFlash coarse pitch scanning in coronary artery imaging was evaluated. Results: The results showed that the left main coronary artery, the right coronary artery and their tertiary branches could be clearly displayed in the three groups of images: the left anterior descending branch, the left circumflex branch, and their three-level branches. There was no statistical difference in subjective image quality among the three groups of pictures (P > 0.05). There was no statistical difference in objective evaluation indexes, such as CT value, SNR, CNR and Noise among the three groups (P > 0.05). The patient radiation dose results showed that the effective radiation dose ED of RES-SPIRA scan was (9.22 ± 1.33) mSv. The dose of SEQ was (2.88 ± 2.47) mSv, and the dose of TurboFlash was (0.51 ± 0.16) mSv. There was significant difference in comparison of the three groups (P 0.05). RES-spiral scanning had the highest radiation dose and TurboFlash coarse pitch scanning (TurboFlash) had the lowest radiation dose. Conclusion: TurboFlash coarse pitch scanning is low in dosage, fast in speed and wide in adaptability. It is especially suitable for the elderly, children, coma and other patients who cannot cooperate with breath-holding examination, as well as for the screening and examination of coronary artery diseases in asymptomatic population. Undoubtedly, it is a worthy method of heart coronary artery examination.展开更多
Objective: On the premise that the image quality meets the requirements of clinical diagnosis, we explored the methods to reduce the radiation dose of coronary artery imaging with Dual-Source CT (DSCT). Methods: We ra...Objective: On the premise that the image quality meets the requirements of clinical diagnosis, we explored the methods to reduce the radiation dose of coronary artery imaging with Dual-Source CT (DSCT). Methods: We randomly selected 200 patients with coronary heat disease (BIM 0.05). The average image noise in group A is (41.76 ± 7.98) HU, in group B the average image noise is (43.97 ± 3.88) HU, the dif- ference between the two groups was not statistically significant (P>0.05). The average CTDIvol of group A and B were (20.63 ± 2.24) mGy, (38.11 ± 10.69) mGy, respectively, then P <0.01. The average DLP of group A and B are (235.75 ± 28.64) mGycm and (492.59 ± 125.49) mGycm respectively, then P <0.01, the dif- ference of radiation dose had statistical significance (P<0.05). Conclusions: For coronary artery imaging with DSCT the heart electric pulse (AUTO) regulation technology can meet the diagnostic requirements and effectively reduce the radiation dose.展开更多
Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention t...Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention therapy. Methods: Eighteen patients with central lungcancer underwent MSCT with real time helical thin-slice CT scanning. Three-dimensional bronchialartery reconstruction was done at the console work-station. The space anatomical characters ofbronchial artery were observed through different rotations. Results: For 6 cases, thethree-dimensional images of bronchial artery (33.33%) could exactly show the origins, the routes(lung inner segment and mediatism segment) and the diameters of bronchial arteries. Vision rate ofbronchial arteries was the highest in pulmonary artery stricture and truncation groups, and thevessels' diameter became larger apparently. These characters demonstrated blood supply of this kindof central lung cancer come from bronchial artery. Volume rendering images were the best ones amongthree-dimensional images. Conclusion: Three-dimensional imaging with MSCT in bronchial artery canreveal the anatomical characters of bronchial artery and provide theoretical evidence on bloodsupply and intervention therapy of central lung cancer.展开更多
基金Supported by the Ministry of Science and Technology of Inner Mongolia, China (20110504)
文摘Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.
文摘Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scanning mode. Methods: The imaging data of 100 patients who underwent CT coronary angiography (CCTA) using Siemens force CT retrospective gated triggering spiral scan (RES-SPIRAL), adaptive prospective gated triggering sequence scan (SEQ) and prospective coarse pitch scan (TurboFlash) retrospectively was collected. The image quality was evaluated by objective and subjective methods. The effective radiation dose of patients was compared and analyzed, and the indications of the three scanning modes were analyzed. The application value of dual-source CT TurboFlash coarse pitch scanning in coronary artery imaging was evaluated. Results: The results showed that the left main coronary artery, the right coronary artery and their tertiary branches could be clearly displayed in the three groups of images: the left anterior descending branch, the left circumflex branch, and their three-level branches. There was no statistical difference in subjective image quality among the three groups of pictures (P > 0.05). There was no statistical difference in objective evaluation indexes, such as CT value, SNR, CNR and Noise among the three groups (P > 0.05). The patient radiation dose results showed that the effective radiation dose ED of RES-SPIRA scan was (9.22 ± 1.33) mSv. The dose of SEQ was (2.88 ± 2.47) mSv, and the dose of TurboFlash was (0.51 ± 0.16) mSv. There was significant difference in comparison of the three groups (P 0.05). RES-spiral scanning had the highest radiation dose and TurboFlash coarse pitch scanning (TurboFlash) had the lowest radiation dose. Conclusion: TurboFlash coarse pitch scanning is low in dosage, fast in speed and wide in adaptability. It is especially suitable for the elderly, children, coma and other patients who cannot cooperate with breath-holding examination, as well as for the screening and examination of coronary artery diseases in asymptomatic population. Undoubtedly, it is a worthy method of heart coronary artery examination.
文摘Objective: On the premise that the image quality meets the requirements of clinical diagnosis, we explored the methods to reduce the radiation dose of coronary artery imaging with Dual-Source CT (DSCT). Methods: We randomly selected 200 patients with coronary heat disease (BIM 0.05). The average image noise in group A is (41.76 ± 7.98) HU, in group B the average image noise is (43.97 ± 3.88) HU, the dif- ference between the two groups was not statistically significant (P>0.05). The average CTDIvol of group A and B were (20.63 ± 2.24) mGy, (38.11 ± 10.69) mGy, respectively, then P <0.01. The average DLP of group A and B are (235.75 ± 28.64) mGycm and (492.59 ± 125.49) mGycm respectively, then P <0.01, the dif- ference of radiation dose had statistical significance (P<0.05). Conclusions: For coronary artery imaging with DSCT the heart electric pulse (AUTO) regulation technology can meet the diagnostic requirements and effectively reduce the radiation dose.
文摘Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention therapy. Methods: Eighteen patients with central lungcancer underwent MSCT with real time helical thin-slice CT scanning. Three-dimensional bronchialartery reconstruction was done at the console work-station. The space anatomical characters ofbronchial artery were observed through different rotations. Results: For 6 cases, thethree-dimensional images of bronchial artery (33.33%) could exactly show the origins, the routes(lung inner segment and mediatism segment) and the diameters of bronchial arteries. Vision rate ofbronchial arteries was the highest in pulmonary artery stricture and truncation groups, and thevessels' diameter became larger apparently. These characters demonstrated blood supply of this kindof central lung cancer come from bronchial artery. Volume rendering images were the best ones amongthree-dimensional images. Conclusion: Three-dimensional imaging with MSCT in bronchial artery canreveal the anatomical characters of bronchial artery and provide theoretical evidence on bloodsupply and intervention therapy of central lung cancer.