期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
An Enhanced Axial-flux Magnetic-geared Machine with Dual-winding Design for Electric Vehicle Applications
1
作者 Weinong Fu Qinying Wu +2 位作者 Shuangxia Niu Yuanxi Chen Xinhua Guo 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第3期239-247,共9页
Axial-flux magnetic-geared machine(MGM) is a promising solution for electric vehicle applications for combining the virtues of both axial-flux electric machine and magnetic gear. However, generalized MGMs are limited ... Axial-flux magnetic-geared machine(MGM) is a promising solution for electric vehicle applications for combining the virtues of both axial-flux electric machine and magnetic gear. However, generalized MGMs are limited by the torque density issue, accordingly inapplicable to industrial applications. To solve the abovementioned issue, an improved axial-flux magnetic-geared machine with a dual-winding design is proposed. The key merit of the proposed design is to achieve enhanced torque performance and space utilization with the proposed design, which installs a set of auxiliary winding between modulation rings. With the proposed design, overload protection capability, and fault-tolerant capability can be also achieved, for the proposed machine can work with either the excitation of armature windings or auxiliary windings. The pole-pair, slot combination, and parametric design is studied and optimized by the 3d finite-element method and designed C++ optimization software. Electromagnetic analysis and performance comparison indicate that the proposed machine can achieve a torque enhancement of 68.6% compared to the comparison machine. 展开更多
关键词 Axial-flux dual-winding Magnetic-geared machine Torque enhancement
下载PDF
Design and Optimization of Dual-Winding Fault-Tolerant Permanent Magnet Motor 被引量:5
2
作者 Xuefeng Jiang Shaoshuai Wang +1 位作者 Qiang Li Yufei Gao 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第1期45-53,共9页
To improve the performance of the traditional fault-tolerant permanent magnet(PM)motor,the design and optimal schemes of dual-winding fault-tolerant permanent magnet motor(DWFT-PMM)are proposed and investigated.In ord... To improve the performance of the traditional fault-tolerant permanent magnet(PM)motor,the design and optimal schemes of dual-winding fault-tolerant permanent magnet motor(DWFT-PMM)are proposed and investigated.In order to obtain small cogging torque ripple and inhibiting the short-circuit current,the air gap surface shape of the PM and the anti short-circuits reactance parameters are designed and optimized.According to the actual design requirements of an aircraft electrical actuation system,the parameters,finite element analysis and experimental verification of the DWFT-PMM after optimal design are presented.The research results show that the optimized DWFT-PMM owns the merits of strong magnetic isolation,physics isolation,inhibiting the short circuit current,small cogging torque ripple and high fault tolerance. 展开更多
关键词 dual-winding motor design and optimization FAULT-TOLERANCE finite element analysis short-circuit fault
下载PDF
A strong robustness open-circuit fault diagnosis strategy for novel fault-tolerant electric drive system based on d-q-axis current signal 被引量:2
3
作者 Xuefeng JIANG Shaoshuai WANG +3 位作者 Jie LI Daoyu WU Wenxin HUANG Zhenmao HAN 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2021年第10期115-127,共13页
To diagnose the Open-Circuit(OC)fault in the novel fault-tolerant electric drive system,based on d-q-axis current signal,a strong robustness diagnosis strategy is proposed and investigated.Fewer independent power supp... To diagnose the Open-Circuit(OC)fault in the novel fault-tolerant electric drive system,based on d-q-axis current signal,a strong robustness diagnosis strategy is proposed and investigated.Fewer independent power supplies and converters are required in the novel fault-tolerant electric drive system based on Dual-Winding Permanent Magnet Motor(DWPMM),and the system’s reliability,usage ratio and power density have been improved compared to the conventional fault-tolerant motor drive system.However,the novel fault-tolerant electric drive system has the OC fault diagnostic false alarms issue when load changes suddenly or under light-load condition.And it lacks the research on the diagnostic method when the system encounters intermittent OC fault in power switches.By theory derivation,simulation and experimental verification,it can be concluded that the proposed strong robustness OC fault diagnosis strategy based on d-q-axis current signal can overcome the OC fault diagnostic false alarms issue when load changes suddenly or under light-load condition.And it can detect and locate the OC fault of single-phase winding in real time,and diagnose the intermittent OC fault of power switches. 展开更多
关键词 dual-winding motor Electric drive system Fault-tolerant system Open-circuit fault diagnosis Permanent magnet motor Strong robustness
原文传递
上一页 1 下一页 到第