The ROD baffle heat exchanger can slightly enhance the shell side heat transfer coefficient with the significant reduction of pressure, loss due to the shell side fluid flowing longitudinally through tube bundle, whic...The ROD baffle heat exchanger can slightly enhance the shell side heat transfer coefficient with the significant reduction of pressure, loss due to the shell side fluid flowing longitudinally through tube bundle, which leads to the reduction of the manufacture and running cost and in some cases to the dimensions reduction of the heat exchangers. Because of the complexities of fluid dynamics equations and the structure of heat exchangers, few theoretical researches have been accomplished to specify the shell side characteristics of the ROD baffle heat exchanger. A unit duct model in the shell side of the longitudinal flow type heat exchanger has been developed based on suitable simplification. A numerical analysis on shell side of the ROD baffle heat exchanger has been carried out at constant wall temperature to obtain the characteristics of heat transfer and pressure drop. The numerical results show that the ROD baffles placed vertically and horizontally in the unit duct continue to shear and comminute the streamline flow when the fluid crosses over the ROD-baffles, and change the fluid flow directions, and then the continuity and stability of the fluid axe destroyed. The effect of disturbing flow can promote fluid turbulent intensity and effectively enhance heat transfer. The numerical analyses can provide the theoretical bases for optimizing the structure of ROD baffle heat exchanger and improving its performance.展开更多
The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analy...The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analyzed.The test shows that making full use of the evaporative cooling "free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the energy efficiency ratio of the Unit(EER)is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the new wind ratio up to 50 percent,more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent.展开更多
The traditional integer order PID controller manipulates the air-conditioning fan coil unit(FCU)that offers cooliug and heatins loads to each air-conditioning room in summer and winter,respectivelv.In order to maintai...The traditional integer order PID controller manipulates the air-conditioning fan coil unit(FCU)that offers cooliug and heatins loads to each air-conditioning room in summer and winter,respectivelv.In order to maintain a steady indoor temperature in summer and winter,the control quality cannot meet the related requirements of air-conditioning automation,such as large overshoot,large steady state error.long regulating time,etc.In view of these factors,this paper develops a fractional order PID controller to deal with such problem associated with FCU.Then,by varving mutation factor and crossover rate of basic differential evolution algorithmadaptivelv,a modified differential evolution algorithm(MDEA)is designed to tune the satisfactory values of five parameters of indoor temperature fractional order PID controller.This fractional order PID coutrol system is configured and the corresponding mumerical simulation is conducted by means of MATLAB software.The results indicate that the proposed fractional order PID control svstem and MDEA are reliable and the related control performance indexes meet with the related requirements of comfortable air-conditioning design and control criteria.展开更多
文摘The ROD baffle heat exchanger can slightly enhance the shell side heat transfer coefficient with the significant reduction of pressure, loss due to the shell side fluid flowing longitudinally through tube bundle, which leads to the reduction of the manufacture and running cost and in some cases to the dimensions reduction of the heat exchangers. Because of the complexities of fluid dynamics equations and the structure of heat exchangers, few theoretical researches have been accomplished to specify the shell side characteristics of the ROD baffle heat exchanger. A unit duct model in the shell side of the longitudinal flow type heat exchanger has been developed based on suitable simplification. A numerical analysis on shell side of the ROD baffle heat exchanger has been carried out at constant wall temperature to obtain the characteristics of heat transfer and pressure drop. The numerical results show that the ROD baffles placed vertically and horizontally in the unit duct continue to shear and comminute the streamline flow when the fluid crosses over the ROD-baffles, and change the fluid flow directions, and then the continuity and stability of the fluid axe destroyed. The effect of disturbing flow can promote fluid turbulent intensity and effectively enhance heat transfer. The numerical analyses can provide the theoretical bases for optimizing the structure of ROD baffle heat exchanger and improving its performance.
基金Xi'an Polytechnic University Graduate Innovational Foundation(chx080608)
文摘The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analyzed.The test shows that making full use of the evaporative cooling "free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the energy efficiency ratio of the Unit(EER)is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the new wind ratio up to 50 percent,more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent.
基金the National Natural Science Foundation of China(Nos.61364004 and 51808275)the Chinese Scholars to Study Overseas Sponsored by ChinaScholarship Council Foundation(No.201408625045)+1 种基金the Doctoral Research Funds of Lanzhou University of Technology(No.04-237)the Alumni Foundation Civil Engineering 77,Lanzhou University of Technology(No.TM-QK1301)。
文摘The traditional integer order PID controller manipulates the air-conditioning fan coil unit(FCU)that offers cooliug and heatins loads to each air-conditioning room in summer and winter,respectivelv.In order to maintain a steady indoor temperature in summer and winter,the control quality cannot meet the related requirements of air-conditioning automation,such as large overshoot,large steady state error.long regulating time,etc.In view of these factors,this paper develops a fractional order PID controller to deal with such problem associated with FCU.Then,by varving mutation factor and crossover rate of basic differential evolution algorithmadaptivelv,a modified differential evolution algorithm(MDEA)is designed to tune the satisfactory values of five parameters of indoor temperature fractional order PID controller.This fractional order PID coutrol system is configured and the corresponding mumerical simulation is conducted by means of MATLAB software.The results indicate that the proposed fractional order PID control svstem and MDEA are reliable and the related control performance indexes meet with the related requirements of comfortable air-conditioning design and control criteria.