The joints connecting vertical and horizontal elements are the "weak link" in structural systems assembled from wood panels. If they are too weak, local failures may occur, resulting in performance that is significa...The joints connecting vertical and horizontal elements are the "weak link" in structural systems assembled from wood panels. If they are too weak, local failures may occur, resulting in performance that is significantly below expectations. If they are too resistant, the joints may be unable to dissipate energy during vibrations, thus possibly initiating a fast progressive failure. This paper re-processes and re-elaborates the results of shaking table tests previously carried out by the author and other co-workers. The goal is to assess the feasibility of a joint which is able to dissipate energy during vibration, without degrading the connection performance.展开更多
Numerical and experimental study was conducted to investigate the failure mode and strength performance of stiffened composite panel repaired by bolted joints under compressive load, and the results were then compared...Numerical and experimental study was conducted to investigate the failure mode and strength performance of stiffened composite panel repaired by bolted joints under compressive load, and the results were then compared with those from virgin stiffened composite panel without any damage. A finite element analysis model was established for repaired and virgin stiffened composite panels under compressive load, the 3D Hashin criteria was applied to identify the composite structure failure, and the secondary stress criteria was adopted to identify the adhesive failure between the base laminate and the stiffener. The failure modes of repaired stiffened composite panels were stiffened composite panels breaking off along the bolt joints. The experimental results were consistent with the finite element analysis results, indicating the reliability of the finite element analysis model.展开更多
In circular shield tunnels bearing high inner pressure or rectangular shaped shield tunnels,as the axial force at the segmental lining decreases,the bolt load at the segmental joint increases.It is essential to adopt ...In circular shield tunnels bearing high inner pressure or rectangular shaped shield tunnels,as the axial force at the segmental lining decreases,the bolt load at the segmental joint increases.It is essential to adopt high-stiffness segmental joints to improve the bearing capacity and control the deformation at the joint position.When designing high-stiffness segmental joints,the selection of ductileiron joint panel is crucial.In this study,two types of segmental joints with different joint panels were fabricated,and the effects of joint panel stiffness on the mechanical properties of segmental joints were analyzed through full-scale sagging and hogging bending tests.The results showed that the failure mode of high-stiffness segmental joint was similar to that of large eccentric compression section.According to the difference of panel stiffness,the failure modes can be specified into two types.If the stiffness is sufficient,the joint failure occurs due to the yielding of bolts;otherwise,it occurs due to the large deformation of ductile-iron joint panels.As for the design requirement of segmental joint,the stiffness of joint panel should be sufficient,i.e.,the opening and failure of the joints are finally induced by the bolt deformation.Otherwise,before the plastic deformation of the bolts,the large deformation of the joint panels will occur under a bendingmoment-dominant load,and the bearing capacity of the joints will greatly decrease.展开更多
基金Italian National Research Council (CNR) Unde Grant No. CU07.00016 ST/97
文摘The joints connecting vertical and horizontal elements are the "weak link" in structural systems assembled from wood panels. If they are too weak, local failures may occur, resulting in performance that is significantly below expectations. If they are too resistant, the joints may be unable to dissipate energy during vibrations, thus possibly initiating a fast progressive failure. This paper re-processes and re-elaborates the results of shaking table tests previously carried out by the author and other co-workers. The goal is to assess the feasibility of a joint which is able to dissipate energy during vibration, without degrading the connection performance.
文摘Numerical and experimental study was conducted to investigate the failure mode and strength performance of stiffened composite panel repaired by bolted joints under compressive load, and the results were then compared with those from virgin stiffened composite panel without any damage. A finite element analysis model was established for repaired and virgin stiffened composite panels under compressive load, the 3D Hashin criteria was applied to identify the composite structure failure, and the secondary stress criteria was adopted to identify the adhesive failure between the base laminate and the stiffener. The failure modes of repaired stiffened composite panels were stiffened composite panels breaking off along the bolt joints. The experimental results were consistent with the finite element analysis results, indicating the reliability of the finite element analysis model.
基金supported by the National Natural Science Foundation of China(Grant No.52090083)the Postdoctoral Innovative Talents Supporting Program(Grant No.BX20200247)the Shanghai Sailing Program(Grant No.20YF1451400).
文摘In circular shield tunnels bearing high inner pressure or rectangular shaped shield tunnels,as the axial force at the segmental lining decreases,the bolt load at the segmental joint increases.It is essential to adopt high-stiffness segmental joints to improve the bearing capacity and control the deformation at the joint position.When designing high-stiffness segmental joints,the selection of ductileiron joint panel is crucial.In this study,two types of segmental joints with different joint panels were fabricated,and the effects of joint panel stiffness on the mechanical properties of segmental joints were analyzed through full-scale sagging and hogging bending tests.The results showed that the failure mode of high-stiffness segmental joint was similar to that of large eccentric compression section.According to the difference of panel stiffness,the failure modes can be specified into two types.If the stiffness is sufficient,the joint failure occurs due to the yielding of bolts;otherwise,it occurs due to the large deformation of ductile-iron joint panels.As for the design requirement of segmental joint,the stiffness of joint panel should be sufficient,i.e.,the opening and failure of the joints are finally induced by the bolt deformation.Otherwise,before the plastic deformation of the bolts,the large deformation of the joint panels will occur under a bendingmoment-dominant load,and the bearing capacity of the joints will greatly decrease.