Dust collection systems represent a significant portion of a wood product manufacturer’s total electricity use. The system fan works against the static pressure of the entire system—the blast gates, the ductwork, an...Dust collection systems represent a significant portion of a wood product manufacturer’s total electricity use. The system fan works against the static pressure of the entire system—the blast gates, the ductwork, and the upstream or downstream cyclone and/or baghouse. A poor system design (e.g., sharp elbows or undersized ductwork) increases the total amount of static pressure in the system, the fan’s performance curve shifts, increasing the total brake horsepower required by the fan (up to the maximum point on the curve). Additionally, system designers may oversize a dust collection system to ensure adequate dust capture and transport, either to accommodate system expansion or simply to be conservative. Since theoretical fan energy use increases with its velocity cubed, this can be an expensive safety net. This paper presents a comprehensive literature review about industrial cyclone dust collectors energy saving in relation to management, technologies, and policies. Energy-saving technologies like high-efficiency motors (HEMs), variable-speed drives (VSDs), leak detection, and pressure drop reduction have all been examined. Based on energy saving technologies results, it has been found that in the industrial sectors, a sizeable amount of electric energy, and utility bill can be saved using these technologies. Finally, various energy-saving policies were reviewed.展开更多
In order to control the maximum tangential velocity V?m(m/s)of the turbulent rotational air flow and the collection efficiencyηc(%)using the fly ash of the mean diameter X R50=5.57?m,two secondary jet nozzles were in...In order to control the maximum tangential velocity V?m(m/s)of the turbulent rotational air flow and the collection efficiencyηc(%)using the fly ash of the mean diameter X R50=5.57?m,two secondary jet nozzles were installed to the body of the axial flow cyclone dust collector with the body diameter D1=99mm.Then in order to estimate V?m(m/s),the conservation theory of the angular momentum flux with Ogawa combined vortex model was applied.The comparisons of the estimated results of V?m(m/s)with the measured results by the cylindrical Pitot-tube were shown in good agreement.And also the estimated collection efficienciesηcth(%)basing upon the cut-size Xc(?m)which was calculated by using the estimated V?m(m/s)and also the particle size distribution R(Xp)were shown a little higher values than the experimental results due to the re-entrainment of the collected dust.The best method for adjustment ofηc(%)related to the contribution of the secondary jet flow is principally to apply the centrifugal effect?c(1).Above stated results are described in detail.展开更多
In order to enhance the atomization efficiency of atomizer, a new type of wind-spray dust controller combining the rotary-atomization and colliding broken of droplets was designed by the method of opening the water ci...In order to enhance the atomization efficiency of atomizer, a new type of wind-spray dust controller combining the rotary-atomization and colliding broken of droplets was designed by the method of opening the water circulation within the blades. The experiment test for dust controller was conducted by adjusting the following parameters: rotating speed, diversion hole-exit diameter, and colliding tooth angle. Results show that the atomization efficiency increases firstly then decreases with them. And the optimal parameters are obtained with rotating speed 1500-2200 r/min, diversion hole-exit diameter 2-2.5 mm and colliding tooth angle 30°-40°, and under these conditions the corresponding atomization efficiency tops to 95%. Then, the atomization situation under the optimal parameters is held from the aspect of simulation internal flow field and the results of droplet size(30-80 μm) are got, which indicates that the conclusion on the optimized parameters of dust controller is reasonable. The collecting efficiencies of different dust concentrations are determined, ranging from 85% to 98.4%, which shows that the designed dust controller can obtain a good atomizing effect and achieve well dustfall efficiency for the wetting dust control of coal mine.展开更多
As the main equipment of flue gas dedusting in coal fired boiler,electrostatic precipitator(ESP)can meet the requirements of emission standard for air pollutants from coal-fired power plants through improving the effi...As the main equipment of flue gas dedusting in coal fired boiler,electrostatic precipitator(ESP)can meet the requirements of emission standard for air pollutants from coal-fired power plants through improving the efficiency of ESP and combining with desulfurization system while not installing wet ESP(WESP).This paper introduces the modifications of ESP cathode structure to improve the efficiency of dust collection by reducing the secondary dust loss at cathode.The application of cathode dust collection provides a reference for the improvement of ESP dust collection efficiency.展开更多
From the mechanical similarity point of view, the centrifugal effect, Ar, and the Stokes number, St, as well as the Reynolds number, Re_c for the motion of solid particles in the cyclone are the relevant parameters. I...From the mechanical similarity point of view, the centrifugal effect, Ar, and the Stokes number, St, as well as the Reynolds number, Re_c for the motion of solid particles in the cyclone are the relevant parameters. In order to apply these similarity laws for the prediction of the characteristics of the collection efficiency, ηc, geometrically similar types of uni-flow cyclones were used. The body diameters of the cyclones were D_1=30, 50, 69 and 99 mm, respectively. The feed particle concentration of the fly-ash particles was up to C_o = 60g/m^3. From the experimental results: (1) the pressure drop, △pc, in the cyclones was a function of not only the Reynods number, Re_c, but also the body diameter, D_1; (2) the collection efficiency, η_c, did not always increase with decreasing body diameter but there existed an optimal body size; (3) application of the mechanical similarity laws to the collection efficiency was not always sufficient for estimating the collection efficiency, since the feed particle concentration was an additional important factor; (4) a new parameter which was the ratio, E_(pf), of the apparent separation energy, W_p, of the solid particles to the energy loss, E_c, of the gas flow in the cyclone was introduced for discussing the collection efficiency; (5) Fuchs theory, used to estimate the collection efficiency, was examined. Fuchs theory may be applied for high feed particle concentration.展开更多
The cyclone dust collector is an important subsystem of straw crushers used in agriculture.In the present study,a new type of dust collector with involute morphology is proposed to obtain better dust removal efficienc...The cyclone dust collector is an important subsystem of straw crushers used in agriculture.In the present study,a new type of dust collector with involute morphology is proposed to obtain better dust removal efficiency with respect to that of classical tangential and spiral dust collectors.A discrete phase model(DPM)method is used in synergy with a turbulence model,and the SIMPLE algorithm to simulate the flow field inside the dust collector and the related particle dynamics.It is shown that the internal flow field features a primary swirl,a secondary swirl and blockage effects.Moreover,for the involute dust collector,the tangential velocity in the initial stage and the pressure in the high-pressure area are larger than those obtained for the classical types.The dust removal efficiency is 37.11%,25.3%,and 16.37%for the involute type dust collector,the tangential type and the spiral type,respectively.展开更多
A cyclone dust collector is applied in many industries. Especially the axial flow cyclone is the mostsimple construction and it keeps high reliability for maintenance. On the other hand, the collectionefficiency of th...A cyclone dust collector is applied in many industries. Especially the axial flow cyclone is the mostsimple construction and it keeps high reliability for maintenance. On the other hand, the collectionefficiency of the cyclone depends not only on the inlet gas velocity but also on the feed particle concentration. The collection efficiency increases with increasing feed particle concentration. However untilnow the problem of how to estimate the collection efficiency depended on the feed particle concentrationis remained except the investigation by Muschelknautz & Brunner~[6]. Therefore in this paper one ofthe estimate method for the collection efficiency of the axial flow cyclones is proposed. The applicationto the geometrically similar type of cyclone of the body diameters D_1=30, 50, 69 and 99 mm showedin good agreement with the experimental results of the collection efficiencies which were described indetail in the paper by Ogawa & Sugiyama~[8].展开更多
文摘Dust collection systems represent a significant portion of a wood product manufacturer’s total electricity use. The system fan works against the static pressure of the entire system—the blast gates, the ductwork, and the upstream or downstream cyclone and/or baghouse. A poor system design (e.g., sharp elbows or undersized ductwork) increases the total amount of static pressure in the system, the fan’s performance curve shifts, increasing the total brake horsepower required by the fan (up to the maximum point on the curve). Additionally, system designers may oversize a dust collection system to ensure adequate dust capture and transport, either to accommodate system expansion or simply to be conservative. Since theoretical fan energy use increases with its velocity cubed, this can be an expensive safety net. This paper presents a comprehensive literature review about industrial cyclone dust collectors energy saving in relation to management, technologies, and policies. Energy-saving technologies like high-efficiency motors (HEMs), variable-speed drives (VSDs), leak detection, and pressure drop reduction have all been examined. Based on energy saving technologies results, it has been found that in the industrial sectors, a sizeable amount of electric energy, and utility bill can be saved using these technologies. Finally, various energy-saving policies were reviewed.
文摘In order to control the maximum tangential velocity V?m(m/s)of the turbulent rotational air flow and the collection efficiencyηc(%)using the fly ash of the mean diameter X R50=5.57?m,two secondary jet nozzles were installed to the body of the axial flow cyclone dust collector with the body diameter D1=99mm.Then in order to estimate V?m(m/s),the conservation theory of the angular momentum flux with Ogawa combined vortex model was applied.The comparisons of the estimated results of V?m(m/s)with the measured results by the cylindrical Pitot-tube were shown in good agreement.And also the estimated collection efficienciesηcth(%)basing upon the cut-size Xc(?m)which was calculated by using the estimated V?m(m/s)and also the particle size distribution R(Xp)were shown a little higher values than the experimental results due to the re-entrainment of the collected dust.The best method for adjustment ofηc(%)related to the contribution of the secondary jet flow is principally to apply the centrifugal effect?c(1).Above stated results are described in detail.
基金Project(U1261107)supported by the Joint Funds of the National Natural Science Foundation of China
文摘In order to enhance the atomization efficiency of atomizer, a new type of wind-spray dust controller combining the rotary-atomization and colliding broken of droplets was designed by the method of opening the water circulation within the blades. The experiment test for dust controller was conducted by adjusting the following parameters: rotating speed, diversion hole-exit diameter, and colliding tooth angle. Results show that the atomization efficiency increases firstly then decreases with them. And the optimal parameters are obtained with rotating speed 1500-2200 r/min, diversion hole-exit diameter 2-2.5 mm and colliding tooth angle 30°-40°, and under these conditions the corresponding atomization efficiency tops to 95%. Then, the atomization situation under the optimal parameters is held from the aspect of simulation internal flow field and the results of droplet size(30-80 μm) are got, which indicates that the conclusion on the optimized parameters of dust controller is reasonable. The collecting efficiencies of different dust concentrations are determined, ranging from 85% to 98.4%, which shows that the designed dust controller can obtain a good atomizing effect and achieve well dustfall efficiency for the wetting dust control of coal mine.
文摘As the main equipment of flue gas dedusting in coal fired boiler,electrostatic precipitator(ESP)can meet the requirements of emission standard for air pollutants from coal-fired power plants through improving the efficiency of ESP and combining with desulfurization system while not installing wet ESP(WESP).This paper introduces the modifications of ESP cathode structure to improve the efficiency of dust collection by reducing the secondary dust loss at cathode.The application of cathode dust collection provides a reference for the improvement of ESP dust collection efficiency.
文摘From the mechanical similarity point of view, the centrifugal effect, Ar, and the Stokes number, St, as well as the Reynolds number, Re_c for the motion of solid particles in the cyclone are the relevant parameters. In order to apply these similarity laws for the prediction of the characteristics of the collection efficiency, ηc, geometrically similar types of uni-flow cyclones were used. The body diameters of the cyclones were D_1=30, 50, 69 and 99 mm, respectively. The feed particle concentration of the fly-ash particles was up to C_o = 60g/m^3. From the experimental results: (1) the pressure drop, △pc, in the cyclones was a function of not only the Reynods number, Re_c, but also the body diameter, D_1; (2) the collection efficiency, η_c, did not always increase with decreasing body diameter but there existed an optimal body size; (3) application of the mechanical similarity laws to the collection efficiency was not always sufficient for estimating the collection efficiency, since the feed particle concentration was an additional important factor; (4) a new parameter which was the ratio, E_(pf), of the apparent separation energy, W_p, of the solid particles to the energy loss, E_c, of the gas flow in the cyclone was introduced for discussing the collection efficiency; (5) Fuchs theory, used to estimate the collection efficiency, was examined. Fuchs theory may be applied for high feed particle concentration.
基金supported by the Independent Research Fund of the State Key Laboratory of Mining Response and Disaster Prevention and Control in Deep Coal Mines(No.SKLMRDPC20ZZ06)and the Program in the Youth Elite Support Plan in Universities of Anhui Province(No.gxyq2020013).
文摘The cyclone dust collector is an important subsystem of straw crushers used in agriculture.In the present study,a new type of dust collector with involute morphology is proposed to obtain better dust removal efficiency with respect to that of classical tangential and spiral dust collectors.A discrete phase model(DPM)method is used in synergy with a turbulence model,and the SIMPLE algorithm to simulate the flow field inside the dust collector and the related particle dynamics.It is shown that the internal flow field features a primary swirl,a secondary swirl and blockage effects.Moreover,for the involute dust collector,the tangential velocity in the initial stage and the pressure in the high-pressure area are larger than those obtained for the classical types.The dust removal efficiency is 37.11%,25.3%,and 16.37%for the involute type dust collector,the tangential type and the spiral type,respectively.
文摘A cyclone dust collector is applied in many industries. Especially the axial flow cyclone is the mostsimple construction and it keeps high reliability for maintenance. On the other hand, the collectionefficiency of the cyclone depends not only on the inlet gas velocity but also on the feed particle concentration. The collection efficiency increases with increasing feed particle concentration. However untilnow the problem of how to estimate the collection efficiency depended on the feed particle concentrationis remained except the investigation by Muschelknautz & Brunner~[6]. Therefore in this paper one ofthe estimate method for the collection efficiency of the axial flow cyclones is proposed. The applicationto the geometrically similar type of cyclone of the body diameters D_1=30, 50, 69 and 99 mm showedin good agreement with the experimental results of the collection efficiencies which were described indetail in the paper by Ogawa & Sugiyama~[8].