An experimental analysis regarding the distribution of the cutting fluid is very difficult due to the inaccessibility of the contact zone within the bore hole.Therefore,suitable simulation models are necessary to eval...An experimental analysis regarding the distribution of the cutting fluid is very difficult due to the inaccessibility of the contact zone within the bore hole.Therefore,suitable simulation models are necessary to evaluate new tool designs and optimize drilling processes.In this paper the coolant distribution during helical deep hole drilling is analyzed with high-speed microscopy.Micro particles are added to the cutting fluid circuit bya developed high-pressure mixing vessel.After the evaluation of suitable particle size,particle concentration and coolant pressure,a computational fluid dynamics(CFD)simulation is validated with the experimental results.The comparison shows a very good model quality with a marginal difference for the flow velocity of 1.57%between simulation and experiment.The simulation considers the kinematic viscosity of the fluid.The results show that the fluid velocity in the chip flutes is low compared to the fluid velocity at the exit of the coolant channels of the tool and drops even further between theguidechamfers.Theflow velocity and the flow pressure directly at the cutting edge decrease to such an extent that the fluid cannot generate a sufficient cooling or lubrication.With the CFD simulation a deeper understanding of the behavior and interactions of the cutting fluid is achieved.Based on these results further research activities to improve the coolant supply can be carried out with great potential to evaluate new tool geometries and optimize the machining process.展开更多
Abstract: The most popularly used fin types in compact heat exchangers are the serrated fins, wavy fins, louvered fins and plain fins. Amongst these fin types the serrated fins assume lot of importance due to its enh...Abstract: The most popularly used fin types in compact heat exchangers are the serrated fins, wavy fins, louvered fins and plain fins. Amongst these fin types the serrated fins assume lot of importance due to its enhanced thermo-hydraulic performance. Thermo-hydraulic design of CHEs (Compact heat exchangers) is strongly dependent upon the predicted/measured dimensionless performance (Colburnj factor and Fanning friction vs. Reynolds number) of heat transfer surfaces. This paper describes the numerical analysis to study the heat transfer coefficient and friction factor of Serrated fins in water medium. CFD (Computational fluid dynamics) methodology has been used to develop the single phase water heat transfer coefficient and friction factor correlations for serrated fins using ANSYS Fluent 14.5. The results are compared with previous air-cooled models and experimental results of water. The water cooled CFD analysis results shows that the Prandtl number has a large effect on the Nusselt number of the serrated fin geometry. Finally, the generalized correlations are developed for serrated fins taking all geometrical parameters into account. This numerical estimation can reduce the number of tests/experiments to a minimum for similar applications.展开更多
The design of an annular combustion chamber in a gas turbine engine is thebackbone of this paper.It is specifically designed for a low bypass turbofan engine in a jettrainer aircraft.The combustion chamber is position...The design of an annular combustion chamber in a gas turbine engine is thebackbone of this paper.It is specifically designed for a low bypass turbofan engine in a jettrainer aircraft.The combustion chamber is positioned in between the compressor and turbine.lt has to be designed based on the constant pressure,enthalpy addition process.The presentmethodology deals with the computation of the initial design parameters from benchmarking ofreal-time industry standards and arriving at optimized values.It is then studied for feasibilityand finalized.Then the various dimensions of the combustor are calculated based on differentempirical formulas.The air mass flow is then distributed across the zones of the combustor.The cooling requirement is met using the cooling holes.Finally the variations of parameters atdifferent points are calculated.The whole combustion chamber is modeled using Siemens NX8.0,a modeling software and presented.The model is then analyzed using various parametersat various stages and levels to determine the optimized design.The aerodynamic flowcharacteristics is simulated numerically by means of ANSYS 14.5 software suite.The air-fuelmixture,combustion-turbulence,thermal and cooling analysis is carried out.The analysis isperformed at various scenarios and compared.The results are then presented in image outputsand graphs.展开更多
Heat-transfer coefficients(HTC)on surfaces exposed to convection environments are often measured by transient techniques such as thermochromic liquid crystal(TLC)or infrared thermography.In these techniques,the surfac...Heat-transfer coefficients(HTC)on surfaces exposed to convection environments are often measured by transient techniques such as thermochromic liquid crystal(TLC)or infrared thermography.In these techniques,the surface temperature is measured as a function of time,and that measurement is used with the exact solution for unsteady,zero-dimensional(0-D)or one-dimensional(1-D)heat conduction into a solid to calculate the local HTC.When using the 0-D or 1-D exact solutions,the transient techniques assume the HTC and the free-stream or bulk temperature characterizing the convection environment to be constants in addition to assuming the conduction into the solid to be 0-D or 1-D.In this study,computational fluid dynamics(CFD)conjugate analyses were performed to examine the errors that might be invoked by these assumptions for a problem,where the free-stream/bulk temperature and the heat-transfer coefficient vary appreciably along the surface and where conduction into the solid may not be 0-D or 1-D.The problem selected to assess these errors is flow and heat transfer in a channel lined with a staggered array of pin fins.This conjugate study uses three-dimensional(3-D)unsteady Reynolds-averaged Navier-Stokes(RANS)closed by the shear-stress transport(SST)turbulence model for the gas phase(wall functions not used)and the Fourier law for the solid phase.The errors in the transient techniques are assessed by comparing the HTC predicted by the time-accurate conjugate CFD with those predicted by the 0-D and 1-D exact solutions,where the surface temperatures needed by the exact solutions are taken from the time-accurate conjugate CFD solution.Results obtained show that the use of the 1-D exact solution for the semi-infinite wall to give reasonably accurate“transient”HTC(less than 5%〇relative error).Transient techniques that use the 0-D exact solution for the pin fins were found to produce large errors(up to 160%relative error)because the HTC varies appreciably about each pin fin.This study also showed that HTC measured by transient techniques could differ considerably from the HTC obtained under steady-state conditions with isothermal walls.展开更多
The fast-growing demand of computational fluid dynamics(CFD) application for computing resources stimulates the development of high performance computing(HPC) and meanwhile raises new requirements for the technolo...The fast-growing demand of computational fluid dynamics(CFD) application for computing resources stimulates the development of high performance computing(HPC) and meanwhile raises new requirements for the technology of parallel application performance monitor and analysis.In response to large-scale and long-time running for the application of CFD,online and scalable performance analysis technology is required to optimize the parallel programs as well as to improve their operational efficiency.As a result,this research implements a scalable infrastructure for online performance analysis on CFD application with homogeneous or heterogeneous system.The infrastructure is part of the parallel application performance monitor and analysis system(PAPMAS) and is composed of two modules which are scalable data transmission module and data storage module.The paper analyzes and elaborates this infrastructure in detail with respect to its design and implementation.Furthermore,some experiments are carried out to verify the rationality and high efficiency of this infrastructure that could be adopted to meet the practical needs.展开更多
文摘An experimental analysis regarding the distribution of the cutting fluid is very difficult due to the inaccessibility of the contact zone within the bore hole.Therefore,suitable simulation models are necessary to evaluate new tool designs and optimize drilling processes.In this paper the coolant distribution during helical deep hole drilling is analyzed with high-speed microscopy.Micro particles are added to the cutting fluid circuit bya developed high-pressure mixing vessel.After the evaluation of suitable particle size,particle concentration and coolant pressure,a computational fluid dynamics(CFD)simulation is validated with the experimental results.The comparison shows a very good model quality with a marginal difference for the flow velocity of 1.57%between simulation and experiment.The simulation considers the kinematic viscosity of the fluid.The results show that the fluid velocity in the chip flutes is low compared to the fluid velocity at the exit of the coolant channels of the tool and drops even further between theguidechamfers.Theflow velocity and the flow pressure directly at the cutting edge decrease to such an extent that the fluid cannot generate a sufficient cooling or lubrication.With the CFD simulation a deeper understanding of the behavior and interactions of the cutting fluid is achieved.Based on these results further research activities to improve the coolant supply can be carried out with great potential to evaluate new tool geometries and optimize the machining process.
文摘Abstract: The most popularly used fin types in compact heat exchangers are the serrated fins, wavy fins, louvered fins and plain fins. Amongst these fin types the serrated fins assume lot of importance due to its enhanced thermo-hydraulic performance. Thermo-hydraulic design of CHEs (Compact heat exchangers) is strongly dependent upon the predicted/measured dimensionless performance (Colburnj factor and Fanning friction vs. Reynolds number) of heat transfer surfaces. This paper describes the numerical analysis to study the heat transfer coefficient and friction factor of Serrated fins in water medium. CFD (Computational fluid dynamics) methodology has been used to develop the single phase water heat transfer coefficient and friction factor correlations for serrated fins using ANSYS Fluent 14.5. The results are compared with previous air-cooled models and experimental results of water. The water cooled CFD analysis results shows that the Prandtl number has a large effect on the Nusselt number of the serrated fin geometry. Finally, the generalized correlations are developed for serrated fins taking all geometrical parameters into account. This numerical estimation can reduce the number of tests/experiments to a minimum for similar applications.
文摘The design of an annular combustion chamber in a gas turbine engine is thebackbone of this paper.It is specifically designed for a low bypass turbofan engine in a jettrainer aircraft.The combustion chamber is positioned in between the compressor and turbine.lt has to be designed based on the constant pressure,enthalpy addition process.The presentmethodology deals with the computation of the initial design parameters from benchmarking ofreal-time industry standards and arriving at optimized values.It is then studied for feasibilityand finalized.Then the various dimensions of the combustor are calculated based on differentempirical formulas.The air mass flow is then distributed across the zones of the combustor.The cooling requirement is met using the cooling holes.Finally the variations of parameters atdifferent points are calculated.The whole combustion chamber is modeled using Siemens NX8.0,a modeling software and presented.The model is then analyzed using various parametersat various stages and levels to determine the optimized design.The aerodynamic flowcharacteristics is simulated numerically by means of ANSYS 14.5 software suite.The air-fuelmixture,combustion-turbulence,thermal and cooling analysis is carried out.The analysis isperformed at various scenarios and compared.The results are then presented in image outputsand graphs.
基金This research was supported by the National Energy Technology Laboratory of the US Department of Energy with Robin Ames and Richard Dennis as the technical monitors.The authors are grateful for this support.
文摘Heat-transfer coefficients(HTC)on surfaces exposed to convection environments are often measured by transient techniques such as thermochromic liquid crystal(TLC)or infrared thermography.In these techniques,the surface temperature is measured as a function of time,and that measurement is used with the exact solution for unsteady,zero-dimensional(0-D)or one-dimensional(1-D)heat conduction into a solid to calculate the local HTC.When using the 0-D or 1-D exact solutions,the transient techniques assume the HTC and the free-stream or bulk temperature characterizing the convection environment to be constants in addition to assuming the conduction into the solid to be 0-D or 1-D.In this study,computational fluid dynamics(CFD)conjugate analyses were performed to examine the errors that might be invoked by these assumptions for a problem,where the free-stream/bulk temperature and the heat-transfer coefficient vary appreciably along the surface and where conduction into the solid may not be 0-D or 1-D.The problem selected to assess these errors is flow and heat transfer in a channel lined with a staggered array of pin fins.This conjugate study uses three-dimensional(3-D)unsteady Reynolds-averaged Navier-Stokes(RANS)closed by the shear-stress transport(SST)turbulence model for the gas phase(wall functions not used)and the Fourier law for the solid phase.The errors in the transient techniques are assessed by comparing the HTC predicted by the time-accurate conjugate CFD with those predicted by the 0-D and 1-D exact solutions,where the surface temperatures needed by the exact solutions are taken from the time-accurate conjugate CFD solution.Results obtained show that the use of the 1-D exact solution for the semi-infinite wall to give reasonably accurate“transient”HTC(less than 5%〇relative error).Transient techniques that use the 0-D exact solution for the pin fins were found to produce large errors(up to 160%relative error)because the HTC varies appreciably about each pin fin.This study also showed that HTC measured by transient techniques could differ considerably from the HTC obtained under steady-state conditions with isothermal walls.
基金Aeronautical Science Foundation of China(2010ZA04001)National Natural Science Foundation of China (61073013,90818024)
文摘The fast-growing demand of computational fluid dynamics(CFD) application for computing resources stimulates the development of high performance computing(HPC) and meanwhile raises new requirements for the technology of parallel application performance monitor and analysis.In response to large-scale and long-time running for the application of CFD,online and scalable performance analysis technology is required to optimize the parallel programs as well as to improve their operational efficiency.As a result,this research implements a scalable infrastructure for online performance analysis on CFD application with homogeneous or heterogeneous system.The infrastructure is part of the parallel application performance monitor and analysis system(PAPMAS) and is composed of two modules which are scalable data transmission module and data storage module.The paper analyzes and elaborates this infrastructure in detail with respect to its design and implementation.Furthermore,some experiments are carried out to verify the rationality and high efficiency of this infrastructure that could be adopted to meet the practical needs.