Artificial Intelligence (AI) expands its recognition rapidly through the past few years in the context of generating content dynamically, remarkably challenging the human creativity. This study aims to evaluate the ef...Artificial Intelligence (AI) expands its recognition rapidly through the past few years in the context of generating content dynamically, remarkably challenging the human creativity. This study aims to evaluate the efficacy of AI in enhancing personal branding for musicians, particularly in crafting brand images based on emotions received from the artist’s music will improve the audience perceptions regarding the artist’s brand. Study used a quantitative approach for the research, gathering primary data from the survey of 191 people—music lovers, musicians and music producers. The survey focuses on preferences, perceptions, and behaviours related to music consumption and artist branding. The study results demonstrate the awareness and understanding of AI’s role in personal branding within the music industry. Also, results indicate that such an adaptive approach enhances audience perceptions of the artist and strengthens emotional connections. Furthermore, over 50% of the participants indicated a desire to attend live events where an artist’s brand image adapts dynamically to their emotions. The study focuses on novel approaches in personal branding based on the interaction of AI-driven emotional data. In contrast to traditional branding concepts, this study indicates that AI can suggest dynamic and emotionally resonant brand identities for artists. The real time audience response gives proper guidance for the decision-making. This study enriches the knowledge of AI’s applicability to branding processes in the context of the music industry and opens the possibilities for additional advancements in building emotionally appealing brand identities.展开更多
Distortion-free data embedding is a technique which can assure that not only the secret data is correctly extracted but also the cover media is recovered without any distortion after secret data is extracted completel...Distortion-free data embedding is a technique which can assure that not only the secret data is correctly extracted but also the cover media is recovered without any distortion after secret data is extracted completely. Because of these advantages, this technique attracts the attention of many researchers. In this paper, a new distortion-free data embedding scheme for high dynamic range (HDR) images is proposed. By depending on Cartesian product, this scheme can obtain higher embedding capacity while maintaining the exactly identical cover image and stego image when using the tone mapping algorithms. In experimental results, the proposed scheme is superior to Yu et aL's scheme in regard to the embedding rate——an average embedding rate of 0.1355 bpp compared with Yn et aL's scheme (0.1270 bpp).展开更多
An effective method for object shape recovery using HDRIs (high dynamic range images) is proposed. The radiance values of each point on the reference sphere and target object are firstly calculated, thus the set of ...An effective method for object shape recovery using HDRIs (high dynamic range images) is proposed. The radiance values of each point on the reference sphere and target object are firstly calculated, thus the set of candidate normals of each target point are found by comparing its radiance to that of each reference sphere point. In single-image shape recovery, a smoothness operation is applied to the target normals to obtain a stable and reasonable result; while in photometric stereo, radiance vectors of reference and target objects formed due to illuminations under different fight source directions are directly compared to get the most suitable target normals. Finally, the height values can be recovered from the resulting normal field. Because diffuse and specular reflection are handled in an unified framework with radiance, our approach eliminates the limitation presented in most recovery strategies, i.e., only Lambertian model can be used. The experiment results from the real and synthesized images show the performance of our approach.展开更多
An improved estimation of motion vectors of feature points is proposed for tracking moving objects of dynamic image sequence. Feature points are firstly extracted by the improved minimum intensity change (MIC) algor...An improved estimation of motion vectors of feature points is proposed for tracking moving objects of dynamic image sequence. Feature points are firstly extracted by the improved minimum intensity change (MIC) algorithm. The matching points of these feature points are then determined by adaptive rood pattern searching. Based on the random sample consensus (RANSAC) method, the background motion is finally compensated by the parameters of an affine transform of the background motion. With reasonable morphological filtering, the moving objects are completely extracted from the background, and then tracked accurately. Experimental results show that the improved method is successful on the motion background compensation and offers great promise in tracking moving objects of the dynamic image sequence.展开更多
The fast X-ray imaging beamline(BL16U2)at Shanghai Synchrotron Radiation Facility(SSRF)is a new beamline that provides X-ray micro-imaging capabilities across a wide range of time scales,spanning from 100 ps toμs and...The fast X-ray imaging beamline(BL16U2)at Shanghai Synchrotron Radiation Facility(SSRF)is a new beamline that provides X-ray micro-imaging capabilities across a wide range of time scales,spanning from 100 ps toμs and ms.This beamline has been specifically designed to facilitate the investigation of a wide range of rapid phenomena,such as the deformation and failure of materials subjected to intense dynamic loads.In addition,it enables the study of high-pressure and high-speed fuel spray processes in automotive engines.The light source of this beamline is a cryogenic permanent magnet undulator(CPMU)that is cooled by liquid nitrogen.This CPMU can generate X-ray photons within an energy range of 8.7-30 keV.The beamline offers two modes of operation:monochromatic beam mode with a liquid nitrogen-cooled double-crystal monochromator(DCM)and pink beam mode with the first crystal of the DCM out of the beam path.Four X-ray imaging methods were implemented in BL16U2:single-pulse ultrafast X-ray imaging,microsecond-resolved X-ray dynamic imaging,millisecond-resolved X-ray dynamic micro-CT,and high-resolution quantitative micro-CT.Furthermore,BL16U2 is equipped with various in situ impact loading systems,such as a split Hopkinson bar system,light gas gun,and fuel spray chamber.Following the completion of the final commissioning in 2021 and subsequent trial operations in 2022,the beamline has been officially available to users from 2023.展开更多
Nuclearmagnetic resonance imaging of breasts often presents complex backgrounds.Breast tumors exhibit varying sizes,uneven intensity,and indistinct boundaries.These characteristics can lead to challenges such as low a...Nuclearmagnetic resonance imaging of breasts often presents complex backgrounds.Breast tumors exhibit varying sizes,uneven intensity,and indistinct boundaries.These characteristics can lead to challenges such as low accuracy and incorrect segmentation during tumor segmentation.Thus,we propose a two-stage breast tumor segmentation method leveraging multi-scale features and boundary attention mechanisms.Initially,the breast region of interest is extracted to isolate the breast area from surrounding tissues and organs.Subsequently,we devise a fusion network incorporatingmulti-scale features and boundary attentionmechanisms for breast tumor segmentation.We incorporate multi-scale parallel dilated convolution modules into the network,enhancing its capability to segment tumors of various sizes through multi-scale convolution and novel fusion techniques.Additionally,attention and boundary detection modules are included to augment the network’s capacity to locate tumors by capturing nonlocal dependencies in both spatial and channel domains.Furthermore,a hybrid loss function with boundary weight is employed to address sample class imbalance issues and enhance the network’s boundary maintenance capability through additional loss.Themethod was evaluated using breast data from 207 patients at RuijinHospital,resulting in a 6.64%increase in Dice similarity coefficient compared to the benchmarkU-Net.Experimental results demonstrate the superiority of the method over other segmentation techniques,with fewer model parameters.展开更多
AIM: To evaluate the ability of the time-signal intensity curve (TIC) of the pancreas obtained from dynamic contrast-enhanced magnetic resonance imaging (MRI) for differentiation of focal pancreatic masses, especially...AIM: To evaluate the ability of the time-signal intensity curve (TIC) of the pancreas obtained from dynamic contrast-enhanced magnetic resonance imaging (MRI) for differentiation of focal pancreatic masses, especially pancreatic carcinoma coexisting with chronic pancreatitis and tumor-forming pancreatitis. METHODS: Forty-eight consecutive patients who underwent surgery for a focal pancreatic mass, including pancreatic ductal carcinoma (n = 33), tumor-forming pancreatitis (n = 8), and islet cell tumor (n = 7), were reviewed. Five pancreatic carcinomas coexisted with longstanding chronic pancreatitis. The pancreatic TICs were obtained from the pancreatic mass and the pancreatic parenchyma both proximal and distal to the mass lesion in each patient, prior to surgery, and were classified into 4 types according to the time to a peak: 25 s and 1, 2, and 3 min after the bolus injection of contrast material, namely, type-Ⅰ, Ⅱ, Ⅲ, and Ⅳ, respectively, and were then compared to the corresponding histological pancreatic conditions. RESULTS: Pancreatic carcinomas demonstrated type-Ⅲ (n = 13) or Ⅳ (n = 20) TIC. Tumor-forming pancreatitis showed type-Ⅱ (n = 5) or Ⅲ (n = 3) TIC. All islet cell tumors revealed type-Ⅰ. The type-Ⅳ TIC was only recognized in pancreatic carcinoma, and the TIC of carcinoma always depicted the slowest rise to a peak among the 3 pancreatic TICs measured in each patient, even in patients with chronic pancreatitis.CONCLUSION: Pancreatic TIC from dynamic MRI provides reliable information for distinguishing pancreatic carcinoma from other pancreatic masses, and may enable us to avoid unnecessary pancreatic surgery and delays in making a correct diagnosis of pancreatic carcinoma, especially, in patients with longstanding chronic pancreatitis.展开更多
Preoperative detection of lymph nodes(LNs) metastasis is always highly challenging for radiologists nowadays. The utility of quantitative dynamic contrast-enhanced magnetic resonance imaging(QDCE-MRI) in identifyi...Preoperative detection of lymph nodes(LNs) metastasis is always highly challenging for radiologists nowadays. The utility of quantitative dynamic contrast-enhanced magnetic resonance imaging(QDCE-MRI) in identifying LNs metastasis is not well understood. In the present study, 59 patients with histologically proven rectal carcinoma underwent preoperative QDCE-MRI. The short axis diameter ratio, long axis diameter ratio, short-to-long axis diameter ratio and QDEC-MRI parameters(Ktrans, Kep, fPV and Ve) values were compared between the non-metastatic(n=44) and metastatic(n=35) LNs groups based on pathological examination. Compared with the non-metastatic group, the metastatic group exhibited significantly higher short axis diameter(7.558±0.668 mm vs. 5.427±0.285 mm), Ktrans(0.483±0.198 min-1 vs. 0.218±0.116 min^-1) and Ve(0.399±0.118 vs. 0.203±0.096) values(all P〈0.05). The short-to-long axis diameter ratio, long axis diameter ratio, Kep and fPV values did not show significant differences between the two groups. In conclusion, our results showed that for LNs larger than 5 mm in rectal cancer, there are distinctive differences in the Ktrans and Ve values between the metastatic and non-metastatic LNs, suggesting that QDCE-MRI may be potentially helpful in identifying LNs status.展开更多
A dynamic imaging method for monitoring self-potential data was proposed.Based on the Darcy’s law and Archie’sformulas,a dynamic model was built as a state model to simulate the transportation of metallic ions in po...A dynamic imaging method for monitoring self-potential data was proposed.Based on the Darcy’s law and Archie’sformulas,a dynamic model was built as a state model to simulate the transportation of metallic ions in porous medium,and theNernst equation was used to calculate the redox potential of metallic ions for observation modeling.Then,the state model andobservation model form an extended Kalman filter cycle to perform dynamic imaging.The noise added synthetic data imaging testshows that the extended Kalman filter can effectively fuse the model evolution and observed self-potential data.The further sandboxmonitoring experiment also demonstrates that the self-potential can be used to monitor the activities of metallic ions and exactlyretrieve the dynamic process of metallic contamination.展开更多
Objective: To evaluate the feasibility of dynamic contrast-enhanced magnetic resonance imaging(DCEMRI) for predicting tumor response to radiotherapy in patients with suspected primary central nervous system(CNS) ...Objective: To evaluate the feasibility of dynamic contrast-enhanced magnetic resonance imaging(DCEMRI) for predicting tumor response to radiotherapy in patients with suspected primary central nervous system(CNS) germ cell tumors(GCTs).Methods: DCE-MRI parameters of 35 patients with suspected primary CNS GCTs were obtained prior to diagnostic radiation, using the Tofts and Kermode model. Radiosensitivity was determined in tumors diagnosed 2 weeks after radiation by observing changes in tumor size and markers as a response to MRI. Taking radiosensitivity as the gold standard, the cut-off value of DCE-MRI parameters was measured by receiver operating characteristic(ROC) curve. Diagnostic accuracy of DCE-MRI parameters for predicting radiosensitivity was evaluated by ROC curve.Results: A significant elevation in transfer constant(K^trans) and extravascular extracellular space(Ve)(P=0.000), as well as a significant reduction in rate constant(Kep)(P=0.000) was observed in tumors. K^trans, relative K^trans, and relative Kep of the responsive group were significantly higher than non-responsive groups. No significant difference was found in Kep, Ve, and relative Ve between the two groups. Relative K^trans showed the best diagnostic value in predicting radiosensitivity with a sensitivity of 100%, specificity of 91.7%, positive predictive value(PPV) of 95.8%, and negative predictive value(NPV) of 100%.Conclusions: Relative K^trans appeared promising in predicting tumor response to radiation therapy(RT). It is implied that DCE-MRI pre-treatment is a requisite step in diagnostic procedures and a novel and reliable approach to guide clinical choice of RT.展开更多
In many areas of oncology, dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) has proven to be a clinically useful, non-invasive functional imaging technique to quantify tumor vasculature and tumor perfusio...In many areas of oncology, dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) has proven to be a clinically useful, non-invasive functional imaging technique to quantify tumor vasculature and tumor perfusion characteristics. Tumor angiogenesis is an essential process for tumor growth, proliferation, and metastasis. Malignant lesions demonstrate rapid extravasation of contrast from the intravascular space to the capillary bed due to leaky capillaries associated with tumor neovascularity. DCE-MRI has the potential to provide information regarding blood flow, areas of hypoperfusion, and variations in endothelial permeability and microvessel density to aid treatment selection, enable frequent monitoring during treatment and assess response to targeted therapy following treatment. This review will discuss the current status of DCE-MRI in cancer imaging, with a focus on its use in imaging prostate malignancies as well as weaknesses that limit its widespread clinical use. The latest techniques for quantification of DCE-MRI parameters will be reviewed and compared.展开更多
A new framework of region-based dynamic image fusion is proposed. First, the technique of target detection is applied to dynamic images (image sequences) to segment images into different targets and background regions...A new framework of region-based dynamic image fusion is proposed. First, the technique of target detection is applied to dynamic images (image sequences) to segment images into different targets and background regions. Then different fusion rules are employed in different regions so that the target information is preserved as much as possible. In addition, steerable non-separable wavelet frame transform is used in the process of multi-resolution analysis, so the system achieves favorable characters of orientation and invariant shift. Compared with other image fusion methods, experimental results showed that the proposed method has better capabilities of target recognition and preserves clear background information.展开更多
The S(1D2)+CO(X1Σ+) product channel from photodissociation of OCS at 217 nm has been measured using the DC slice velocity map imaging (VMI) technique in combination with resonance enhanced multiphoton ionizat...The S(1D2)+CO(X1Σ+) product channel from photodissociation of OCS at 217 nm has been measured using the DC slice velocity map imaging (VMI) technique in combination with resonance enhanced multiphoton ionization (REMPI). Two diflerent REMPI intermediate states (1F3 and 1P1) and several pump-probe laser polarization geometries are used to detect the angular momentum polarization of the photofragmented S(1D2). The molecular- frame polarization parameters, as well as the laboratory-frame anisotropy parameters, for individual rotational states of co-fragment CO, are determined using two diflerent full quantum theories. The measured total kinetic energy release spectrum from photodissociation of OCS indicates two dissociation channels, corresponding to the fast and slow recoiling velocities of S(1D2), respectively. The slow channel is concluded to originate from an initial photoexcitation to the A(1A') state, followed by a non-adiabatic transition to the ground state. The fast channel is found to follow a coherent excitation to A(1A') and B(1A') states, where contributions of the two states are almost equal at 217 nm. The determined alignment and anisotropy parameters further indicate that the slow channel follows an incoherent excitation, while the fast channel follows a coherent excitation to A(1A') and B(1A') states with a phase di erence of π/2.展开更多
The dynamic multichannel binocular visual image modeling is studied based on Internet of Things (IoT) Perception Layer, using mobile robot self-organizing network. By employing multigroup mobile robots with binocular ...The dynamic multichannel binocular visual image modeling is studied based on Internet of Things (IoT) Perception Layer, using mobile robot self-organizing network. By employing multigroup mobile robots with binocular visual system, the real visual images of the object will be obtained. Then through the mobile self-organizing network, a three-dimensional model is rebuilt by synthesizing the returned images. On this basis, we formalize a novel algorithm for multichannel binocular visual three-dimensional images based on fast three-dimensional modeling. Compared with the method based on single binocular visual system, the new algorithm can improve the Integrity and accuracy of the dynamic three-dimensional object modeling. The simulation results show that the new method can effectively accelerate the modeling speed, improve the similarity and not increase the data size.展开更多
To evaluate the performance of basic shape representation methods for the description of dynamic cellular morphology, several frequently-used shape descriptors are compared. The methods are examined by using 50 lympho...To evaluate the performance of basic shape representation methods for the description of dynamic cellular morphology, several frequently-used shape descriptors are compared. The methods are examined by using 50 lymphocyte video clips including two kinds of lymphocyte cells. Our goal is to represent cell shape in each frame accurately, meanwhile precisely classify the two groups of cells based on the cellular morphological variations in the video clips. Experimental results illustrate that in general the region-based shape descriptors outperform the contour-based ones, since the contourbased methods are excessively sensitive and ignorant to cellular internal information. Due to their robustness to noise, the region-based shape descriptors are suitable for dynamic cell representation. Although region-based methods are more time-consuming, they analyze the entire cell area.展开更多
Objective: To prospectively compare the discriminative capacity of dynamic contrast enhanced-magnetic resonance imaging(DCE-MRI) with that of^18F-fluorodeoxyglucose(^18F-FDG) positron emission tomography/computed...Objective: To prospectively compare the discriminative capacity of dynamic contrast enhanced-magnetic resonance imaging(DCE-MRI) with that of^18F-fluorodeoxyglucose(^18F-FDG) positron emission tomography/computed tomography(PET/CT) in the differentiation of malignant and benign solitary pulmonary nodules(SPNs).Methods: Forty-nine patients with SPNs were included in this prospective study. Thirty-two of the patients had malignant SPNs, while the other 17 had benign SPNs. All these patients underwent DCE-MRI and ^18F-FDG PET/CT examinations. The quantitative MRI pharmacokinetic parameters, including the trans-endothelial transfer constant(K^trans), redistribution rate constant(Kep), and fractional volume(Ve), were calculated using the Extended-Tofts Linear two-compartment model. The ^18F-FDG PET/CT parameter, maximum standardized uptake value(SUV(max)), was also measured. Spearman's correlations were calculated between the MRI pharmacokinetic parameters and the SUV(max) of each SPN. These parameters were statistically compared between the malignant and benign nodules. Receiver operating characteristic(ROC) analyses were used to compare the diagnostic capability between the DCE-MRI and ^18F-FDG PET/CT indexes.Results: Positive correlations were found between K^trans and SUV(max), and between K(ep) and SUV(max)(P〈0.05).There were significant differences between the malignant and benign nodules in terms of the K^trans, K(ep) and SUV(max) values(P〈0.05). The areas under the ROC curve(AUC) of K^trans) K(ep) and SUV(max) between the malignant and benign nodules were 0.909, 0.838 and 0.759, respectively. The sensitivity and specificity in differentiating malignant from benign SPNs were 90.6% and 82.4% for K^trans; 87.5% and 76.5% for K(ep); and 75.0% and 70.6%for SUV(max), respectively. The sensitivity and specificity of K^trans and K(ep) were higher than those of SUV(max), but there was no significant difference between them(P〉0.05).Conclusions: DCE-MRI can be used to differentiate between benign and malignant SPNs and has the advantage of being radiation free.展开更多
A novel method combining visualization particle tracking with image-based dynamic light scattering was developed to achieve the in situ and real-time size measurement of nanobubbles(NBs).First,the in situ size distrib...A novel method combining visualization particle tracking with image-based dynamic light scattering was developed to achieve the in situ and real-time size measurement of nanobubbles(NBs).First,the in situ size distribution of NBs was visualized by dark-field microscopy.Then,real-time size during the preparation was measured using image-based dynamic light scattering,and the longitudinal size distribution of NBs in the sample cell was obtained in a steady state.Results show that this strategy can provide a detailed and accurate size of bubbles in the whole sample compared with the commercial ZetaSizer Nano equipment.Therefore,the developed method is a real-time and simple technology with excellent accuracy,providing new insights into the accurate measurement of the size distribution of NBs or nanoparticles in solution.展开更多
After a brief review of existing methods for fabric wetting and wicking measurement,a new numerical approach based on dynamic image acquisition and analysis was proposed to study the liquid wetting and wicking propert...After a brief review of existing methods for fabric wetting and wicking measurement,a new numerical approach based on dynamic image acquisition and analysis was proposed to study the liquid wetting and wicking properties of woven fabrics.A measuring system was first developed to record on-site the images of liquid ascending in fabrics for a certain period of time.The hardware and software platforms and the experimental methods were described,and the image processing and analysis as well as other related algorithms were discussed in detail.The liquid front curves and rising rates in wetting and wicking were eventually obtained towards different fabrics.From liquid wicking curves,relationship between liquid ascending height and liquid ascending time agrees well with the Washburn theory.The data comparison between the numerical measurement and the traditional test proves the reliability of the numerical results.展开更多
Speedometer identification has been researched for many years.The common approaches to that problem are usually based on image subtraction,which does not adapt to image offsets caused by camera vibration.To cope with ...Speedometer identification has been researched for many years.The common approaches to that problem are usually based on image subtraction,which does not adapt to image offsets caused by camera vibration.To cope with the rapidity,robust and accurate requirements of this kind of work in dynamic scene,a fast speedometer identification algorithm is proposed,it utilizes phase correlation method based on regional entire template translation to estimate the offset between images.In order to effectively reduce unnecessary computation and false detection rate,an improved linear Hough transform method with two optimization strategies is presented for pointer line detection.Based on VC++ 6.0 software platform with OpenCV library,the algorithm performance under experiments has shown that it celerity and precision.展开更多
BACKGROUND: AND PURPOSE: The measurement of relative cerebral blood volume (rCBV) and the volume transfer constant (K(trans)) by means of dynamic contrast-enhanced (DCE) perfusion MR imaging (pMRI) can be useful in ch...BACKGROUND: AND PURPOSE: The measurement of relative cerebral blood volume (rCBV) and the volume transfer constant (K(trans)) by means of dynamic contrast-enhanced (DCE) perfusion MR imaging (pMRI) can be useful in characterizing brain tumors. The purpose of our study was to evaluate the utility of these measurements in differentiating typical meningiomas and atypical meningiomas. METHODS: Fifteen patients with pathologically confirmed typical meningiomas and seven with atypical meningiomas underwent conventional imaging and DCE pMRI before resection.rCBV measurements were calculated by using standard intravascular展开更多
文摘Artificial Intelligence (AI) expands its recognition rapidly through the past few years in the context of generating content dynamically, remarkably challenging the human creativity. This study aims to evaluate the efficacy of AI in enhancing personal branding for musicians, particularly in crafting brand images based on emotions received from the artist’s music will improve the audience perceptions regarding the artist’s brand. Study used a quantitative approach for the research, gathering primary data from the survey of 191 people—music lovers, musicians and music producers. The survey focuses on preferences, perceptions, and behaviours related to music consumption and artist branding. The study results demonstrate the awareness and understanding of AI’s role in personal branding within the music industry. Also, results indicate that such an adaptive approach enhances audience perceptions of the artist and strengthens emotional connections. Furthermore, over 50% of the participants indicated a desire to attend live events where an artist’s brand image adapts dynamically to their emotions. The study focuses on novel approaches in personal branding based on the interaction of AI-driven emotional data. In contrast to traditional branding concepts, this study indicates that AI can suggest dynamic and emotionally resonant brand identities for artists. The real time audience response gives proper guidance for the decision-making. This study enriches the knowledge of AI’s applicability to branding processes in the context of the music industry and opens the possibilities for additional advancements in building emotionally appealing brand identities.
文摘Distortion-free data embedding is a technique which can assure that not only the secret data is correctly extracted but also the cover media is recovered without any distortion after secret data is extracted completely. Because of these advantages, this technique attracts the attention of many researchers. In this paper, a new distortion-free data embedding scheme for high dynamic range (HDR) images is proposed. By depending on Cartesian product, this scheme can obtain higher embedding capacity while maintaining the exactly identical cover image and stego image when using the tone mapping algorithms. In experimental results, the proposed scheme is superior to Yu et aL's scheme in regard to the embedding rate——an average embedding rate of 0.1355 bpp compared with Yn et aL's scheme (0.1270 bpp).
基金the National Basic Research Program of China(No.2006CB303105)
文摘An effective method for object shape recovery using HDRIs (high dynamic range images) is proposed. The radiance values of each point on the reference sphere and target object are firstly calculated, thus the set of candidate normals of each target point are found by comparing its radiance to that of each reference sphere point. In single-image shape recovery, a smoothness operation is applied to the target normals to obtain a stable and reasonable result; while in photometric stereo, radiance vectors of reference and target objects formed due to illuminations under different fight source directions are directly compared to get the most suitable target normals. Finally, the height values can be recovered from the resulting normal field. Because diffuse and specular reflection are handled in an unified framework with radiance, our approach eliminates the limitation presented in most recovery strategies, i.e., only Lambertian model can be used. The experiment results from the real and synthesized images show the performance of our approach.
文摘An improved estimation of motion vectors of feature points is proposed for tracking moving objects of dynamic image sequence. Feature points are firstly extracted by the improved minimum intensity change (MIC) algorithm. The matching points of these feature points are then determined by adaptive rood pattern searching. Based on the random sample consensus (RANSAC) method, the background motion is finally compensated by the parameters of an affine transform of the background motion. With reasonable morphological filtering, the moving objects are completely extracted from the background, and then tracked accurately. Experimental results show that the improved method is successful on the motion background compensation and offers great promise in tracking moving objects of the dynamic image sequence.
基金supported by the CAS Project for Young Scientists in Basic Research(YSBR-096)the National Major Scientific Instruments and Equipment Development Project of China(No.11627901)+1 种基金the National Key Research and Development Program of China(Nos.2021YFF0701202,2021YFA1600703)the National Natural Science Foundation of China(Nos.U1932205,12275343).
文摘The fast X-ray imaging beamline(BL16U2)at Shanghai Synchrotron Radiation Facility(SSRF)is a new beamline that provides X-ray micro-imaging capabilities across a wide range of time scales,spanning from 100 ps toμs and ms.This beamline has been specifically designed to facilitate the investigation of a wide range of rapid phenomena,such as the deformation and failure of materials subjected to intense dynamic loads.In addition,it enables the study of high-pressure and high-speed fuel spray processes in automotive engines.The light source of this beamline is a cryogenic permanent magnet undulator(CPMU)that is cooled by liquid nitrogen.This CPMU can generate X-ray photons within an energy range of 8.7-30 keV.The beamline offers two modes of operation:monochromatic beam mode with a liquid nitrogen-cooled double-crystal monochromator(DCM)and pink beam mode with the first crystal of the DCM out of the beam path.Four X-ray imaging methods were implemented in BL16U2:single-pulse ultrafast X-ray imaging,microsecond-resolved X-ray dynamic imaging,millisecond-resolved X-ray dynamic micro-CT,and high-resolution quantitative micro-CT.Furthermore,BL16U2 is equipped with various in situ impact loading systems,such as a split Hopkinson bar system,light gas gun,and fuel spray chamber.Following the completion of the final commissioning in 2021 and subsequent trial operations in 2022,the beamline has been officially available to users from 2023.
基金funded by the National Natural Foundation of China under Grant No.61172167the Science Fund Project of Heilongjiang Province(LH2020F035).
文摘Nuclearmagnetic resonance imaging of breasts often presents complex backgrounds.Breast tumors exhibit varying sizes,uneven intensity,and indistinct boundaries.These characteristics can lead to challenges such as low accuracy and incorrect segmentation during tumor segmentation.Thus,we propose a two-stage breast tumor segmentation method leveraging multi-scale features and boundary attention mechanisms.Initially,the breast region of interest is extracted to isolate the breast area from surrounding tissues and organs.Subsequently,we devise a fusion network incorporatingmulti-scale features and boundary attentionmechanisms for breast tumor segmentation.We incorporate multi-scale parallel dilated convolution modules into the network,enhancing its capability to segment tumors of various sizes through multi-scale convolution and novel fusion techniques.Additionally,attention and boundary detection modules are included to augment the network’s capacity to locate tumors by capturing nonlocal dependencies in both spatial and channel domains.Furthermore,a hybrid loss function with boundary weight is employed to address sample class imbalance issues and enhance the network’s boundary maintenance capability through additional loss.Themethod was evaluated using breast data from 207 patients at RuijinHospital,resulting in a 6.64%increase in Dice similarity coefficient compared to the benchmarkU-Net.Experimental results demonstrate the superiority of the method over other segmentation techniques,with fewer model parameters.
文摘AIM: To evaluate the ability of the time-signal intensity curve (TIC) of the pancreas obtained from dynamic contrast-enhanced magnetic resonance imaging (MRI) for differentiation of focal pancreatic masses, especially pancreatic carcinoma coexisting with chronic pancreatitis and tumor-forming pancreatitis. METHODS: Forty-eight consecutive patients who underwent surgery for a focal pancreatic mass, including pancreatic ductal carcinoma (n = 33), tumor-forming pancreatitis (n = 8), and islet cell tumor (n = 7), were reviewed. Five pancreatic carcinomas coexisted with longstanding chronic pancreatitis. The pancreatic TICs were obtained from the pancreatic mass and the pancreatic parenchyma both proximal and distal to the mass lesion in each patient, prior to surgery, and were classified into 4 types according to the time to a peak: 25 s and 1, 2, and 3 min after the bolus injection of contrast material, namely, type-Ⅰ, Ⅱ, Ⅲ, and Ⅳ, respectively, and were then compared to the corresponding histological pancreatic conditions. RESULTS: Pancreatic carcinomas demonstrated type-Ⅲ (n = 13) or Ⅳ (n = 20) TIC. Tumor-forming pancreatitis showed type-Ⅱ (n = 5) or Ⅲ (n = 3) TIC. All islet cell tumors revealed type-Ⅰ. The type-Ⅳ TIC was only recognized in pancreatic carcinoma, and the TIC of carcinoma always depicted the slowest rise to a peak among the 3 pancreatic TICs measured in each patient, even in patients with chronic pancreatitis.CONCLUSION: Pancreatic TIC from dynamic MRI provides reliable information for distinguishing pancreatic carcinoma from other pancreatic masses, and may enable us to avoid unnecessary pancreatic surgery and delays in making a correct diagnosis of pancreatic carcinoma, especially, in patients with longstanding chronic pancreatitis.
基金supported by the Provincial Key Clinical Specialty(Medical Imaging)Development Program from Health and Family Planning Commission of Hunan Province,China(No.2015/43)the Health and Family Planning Commission of Hunan Province,China(No.B2016060)the National Key Clinical Specialty(Oncology Department)Development Program from National Health and Family Planning Commission of China(No.2013/544)
文摘Preoperative detection of lymph nodes(LNs) metastasis is always highly challenging for radiologists nowadays. The utility of quantitative dynamic contrast-enhanced magnetic resonance imaging(QDCE-MRI) in identifying LNs metastasis is not well understood. In the present study, 59 patients with histologically proven rectal carcinoma underwent preoperative QDCE-MRI. The short axis diameter ratio, long axis diameter ratio, short-to-long axis diameter ratio and QDEC-MRI parameters(Ktrans, Kep, fPV and Ve) values were compared between the non-metastatic(n=44) and metastatic(n=35) LNs groups based on pathological examination. Compared with the non-metastatic group, the metastatic group exhibited significantly higher short axis diameter(7.558±0.668 mm vs. 5.427±0.285 mm), Ktrans(0.483±0.198 min-1 vs. 0.218±0.116 min^-1) and Ve(0.399±0.118 vs. 0.203±0.096) values(all P〈0.05). The short-to-long axis diameter ratio, long axis diameter ratio, Kep and fPV values did not show significant differences between the two groups. In conclusion, our results showed that for LNs larger than 5 mm in rectal cancer, there are distinctive differences in the Ktrans and Ve values between the metastatic and non-metastatic LNs, suggesting that QDCE-MRI may be potentially helpful in identifying LNs status.
基金Project(41574123) supported by the National Natural Science Foundation of ChinaProject(2013FY110800) supported by the National Basic Research Scientific Program of China
文摘A dynamic imaging method for monitoring self-potential data was proposed.Based on the Darcy’s law and Archie’sformulas,a dynamic model was built as a state model to simulate the transportation of metallic ions in porous medium,and theNernst equation was used to calculate the redox potential of metallic ions for observation modeling.Then,the state model andobservation model form an extended Kalman filter cycle to perform dynamic imaging.The noise added synthetic data imaging testshows that the extended Kalman filter can effectively fuse the model evolution and observed self-potential data.The further sandboxmonitoring experiment also demonstrates that the self-potential can be used to monitor the activities of metallic ions and exactlyretrieve the dynamic process of metallic contamination.
基金supported by Beijing Natural Science Foundation(No.7122029)
文摘Objective: To evaluate the feasibility of dynamic contrast-enhanced magnetic resonance imaging(DCEMRI) for predicting tumor response to radiotherapy in patients with suspected primary central nervous system(CNS) germ cell tumors(GCTs).Methods: DCE-MRI parameters of 35 patients with suspected primary CNS GCTs were obtained prior to diagnostic radiation, using the Tofts and Kermode model. Radiosensitivity was determined in tumors diagnosed 2 weeks after radiation by observing changes in tumor size and markers as a response to MRI. Taking radiosensitivity as the gold standard, the cut-off value of DCE-MRI parameters was measured by receiver operating characteristic(ROC) curve. Diagnostic accuracy of DCE-MRI parameters for predicting radiosensitivity was evaluated by ROC curve.Results: A significant elevation in transfer constant(K^trans) and extravascular extracellular space(Ve)(P=0.000), as well as a significant reduction in rate constant(Kep)(P=0.000) was observed in tumors. K^trans, relative K^trans, and relative Kep of the responsive group were significantly higher than non-responsive groups. No significant difference was found in Kep, Ve, and relative Ve between the two groups. Relative K^trans showed the best diagnostic value in predicting radiosensitivity with a sensitivity of 100%, specificity of 91.7%, positive predictive value(PPV) of 95.8%, and negative predictive value(NPV) of 100%.Conclusions: Relative K^trans appeared promising in predicting tumor response to radiation therapy(RT). It is implied that DCE-MRI pre-treatment is a requisite step in diagnostic procedures and a novel and reliable approach to guide clinical choice of RT.
文摘In many areas of oncology, dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) has proven to be a clinically useful, non-invasive functional imaging technique to quantify tumor vasculature and tumor perfusion characteristics. Tumor angiogenesis is an essential process for tumor growth, proliferation, and metastasis. Malignant lesions demonstrate rapid extravasation of contrast from the intravascular space to the capillary bed due to leaky capillaries associated with tumor neovascularity. DCE-MRI has the potential to provide information regarding blood flow, areas of hypoperfusion, and variations in endothelial permeability and microvessel density to aid treatment selection, enable frequent monitoring during treatment and assess response to targeted therapy following treatment. This review will discuss the current status of DCE-MRI in cancer imaging, with a focus on its use in imaging prostate malignancies as well as weaknesses that limit its widespread clinical use. The latest techniques for quantification of DCE-MRI parameters will be reviewed and compared.
基金Project (No. 2004CB719401) supported by the National Basic Research Program (973) of China
文摘A new framework of region-based dynamic image fusion is proposed. First, the technique of target detection is applied to dynamic images (image sequences) to segment images into different targets and background regions. Then different fusion rules are employed in different regions so that the target information is preserved as much as possible. In addition, steerable non-separable wavelet frame transform is used in the process of multi-resolution analysis, so the system achieves favorable characters of orientation and invariant shift. Compared with other image fusion methods, experimental results showed that the proposed method has better capabilities of target recognition and preserves clear background information.
文摘The S(1D2)+CO(X1Σ+) product channel from photodissociation of OCS at 217 nm has been measured using the DC slice velocity map imaging (VMI) technique in combination with resonance enhanced multiphoton ionization (REMPI). Two diflerent REMPI intermediate states (1F3 and 1P1) and several pump-probe laser polarization geometries are used to detect the angular momentum polarization of the photofragmented S(1D2). The molecular- frame polarization parameters, as well as the laboratory-frame anisotropy parameters, for individual rotational states of co-fragment CO, are determined using two diflerent full quantum theories. The measured total kinetic energy release spectrum from photodissociation of OCS indicates two dissociation channels, corresponding to the fast and slow recoiling velocities of S(1D2), respectively. The slow channel is concluded to originate from an initial photoexcitation to the A(1A') state, followed by a non-adiabatic transition to the ground state. The fast channel is found to follow a coherent excitation to A(1A') and B(1A') states, where contributions of the two states are almost equal at 217 nm. The determined alignment and anisotropy parameters further indicate that the slow channel follows an incoherent excitation, while the fast channel follows a coherent excitation to A(1A') and B(1A') states with a phase di erence of π/2.
基金supported by HiTech Researchand Development Program of China under Grant No.2007AA10Z235
文摘The dynamic multichannel binocular visual image modeling is studied based on Internet of Things (IoT) Perception Layer, using mobile robot self-organizing network. By employing multigroup mobile robots with binocular visual system, the real visual images of the object will be obtained. Then through the mobile self-organizing network, a three-dimensional model is rebuilt by synthesizing the returned images. On this basis, we formalize a novel algorithm for multichannel binocular visual three-dimensional images based on fast three-dimensional modeling. Compared with the method based on single binocular visual system, the new algorithm can improve the Integrity and accuracy of the dynamic three-dimensional object modeling. The simulation results show that the new method can effectively accelerate the modeling speed, improve the similarity and not increase the data size.
基金Supported by the National Natural Science Foundation of China(61271112)
文摘To evaluate the performance of basic shape representation methods for the description of dynamic cellular morphology, several frequently-used shape descriptors are compared. The methods are examined by using 50 lymphocyte video clips including two kinds of lymphocyte cells. Our goal is to represent cell shape in each frame accurately, meanwhile precisely classify the two groups of cells based on the cellular morphological variations in the video clips. Experimental results illustrate that in general the region-based shape descriptors outperform the contour-based ones, since the contourbased methods are excessively sensitive and ignorant to cellular internal information. Due to their robustness to noise, the region-based shape descriptors are suitable for dynamic cell representation. Although region-based methods are more time-consuming, they analyze the entire cell area.
基金supported by the Jiangsu Province Natural Science Foundation (No. BK20161291)the Nantong Science Foundation of China (No. MS2201507)the Nantong Municipal Commission of Health and Family Planning Young Fund (No. WQ2014047)
文摘Objective: To prospectively compare the discriminative capacity of dynamic contrast enhanced-magnetic resonance imaging(DCE-MRI) with that of^18F-fluorodeoxyglucose(^18F-FDG) positron emission tomography/computed tomography(PET/CT) in the differentiation of malignant and benign solitary pulmonary nodules(SPNs).Methods: Forty-nine patients with SPNs were included in this prospective study. Thirty-two of the patients had malignant SPNs, while the other 17 had benign SPNs. All these patients underwent DCE-MRI and ^18F-FDG PET/CT examinations. The quantitative MRI pharmacokinetic parameters, including the trans-endothelial transfer constant(K^trans), redistribution rate constant(Kep), and fractional volume(Ve), were calculated using the Extended-Tofts Linear two-compartment model. The ^18F-FDG PET/CT parameter, maximum standardized uptake value(SUV(max)), was also measured. Spearman's correlations were calculated between the MRI pharmacokinetic parameters and the SUV(max) of each SPN. These parameters were statistically compared between the malignant and benign nodules. Receiver operating characteristic(ROC) analyses were used to compare the diagnostic capability between the DCE-MRI and ^18F-FDG PET/CT indexes.Results: Positive correlations were found between K^trans and SUV(max), and between K(ep) and SUV(max)(P〈0.05).There were significant differences between the malignant and benign nodules in terms of the K^trans, K(ep) and SUV(max) values(P〈0.05). The areas under the ROC curve(AUC) of K^trans) K(ep) and SUV(max) between the malignant and benign nodules were 0.909, 0.838 and 0.759, respectively. The sensitivity and specificity in differentiating malignant from benign SPNs were 90.6% and 82.4% for K^trans; 87.5% and 76.5% for K(ep); and 75.0% and 70.6%for SUV(max), respectively. The sensitivity and specificity of K^trans and K(ep) were higher than those of SUV(max), but there was no significant difference between them(P〉0.05).Conclusions: DCE-MRI can be used to differentiate between benign and malignant SPNs and has the advantage of being radiation free.
基金The National Key Research and Development Program of China(No.2017YFA0104302)the National Natural Science Foundation of China(No.51832001,61821002,81971750).
文摘A novel method combining visualization particle tracking with image-based dynamic light scattering was developed to achieve the in situ and real-time size measurement of nanobubbles(NBs).First,the in situ size distribution of NBs was visualized by dark-field microscopy.Then,real-time size during the preparation was measured using image-based dynamic light scattering,and the longitudinal size distribution of NBs in the sample cell was obtained in a steady state.Results show that this strategy can provide a detailed and accurate size of bubbles in the whole sample compared with the commercial ZetaSizer Nano equipment.Therefore,the developed method is a real-time and simple technology with excellent accuracy,providing new insights into the accurate measurement of the size distribution of NBs or nanoparticles in solution.
基金the Research Funds for the Central Universities,China(No.1302-1)The Project Sponsored SRF for ROCS,SEM,China
文摘After a brief review of existing methods for fabric wetting and wicking measurement,a new numerical approach based on dynamic image acquisition and analysis was proposed to study the liquid wetting and wicking properties of woven fabrics.A measuring system was first developed to record on-site the images of liquid ascending in fabrics for a certain period of time.The hardware and software platforms and the experimental methods were described,and the image processing and analysis as well as other related algorithms were discussed in detail.The liquid front curves and rising rates in wetting and wicking were eventually obtained towards different fabrics.From liquid wicking curves,relationship between liquid ascending height and liquid ascending time agrees well with the Washburn theory.The data comparison between the numerical measurement and the traditional test proves the reliability of the numerical results.
基金Supported by the National Natural Science Foundation of China (61004139)Beijing Municipal Natural Science Foundation(4101001)2008 Yangtze Fund Scholar and Innovative Research Team Development Schemes of Ministry of Education
文摘Speedometer identification has been researched for many years.The common approaches to that problem are usually based on image subtraction,which does not adapt to image offsets caused by camera vibration.To cope with the rapidity,robust and accurate requirements of this kind of work in dynamic scene,a fast speedometer identification algorithm is proposed,it utilizes phase correlation method based on regional entire template translation to estimate the offset between images.In order to effectively reduce unnecessary computation and false detection rate,an improved linear Hough transform method with two optimization strategies is presented for pointer line detection.Based on VC++ 6.0 software platform with OpenCV library,the algorithm performance under experiments has shown that it celerity and precision.
文摘BACKGROUND: AND PURPOSE: The measurement of relative cerebral blood volume (rCBV) and the volume transfer constant (K(trans)) by means of dynamic contrast-enhanced (DCE) perfusion MR imaging (pMRI) can be useful in characterizing brain tumors. The purpose of our study was to evaluate the utility of these measurements in differentiating typical meningiomas and atypical meningiomas. METHODS: Fifteen patients with pathologically confirmed typical meningiomas and seven with atypical meningiomas underwent conventional imaging and DCE pMRI before resection.rCBV measurements were calculated by using standard intravascular