Maxillary protrusion combined with mandibular retraction is a highly prevalent but extremely complex maxillofacial deformity that can have a serious negative impact on patients’facial aesthetics and mental health.The...Maxillary protrusion combined with mandibular retraction is a highly prevalent but extremely complex maxillofacial deformity that can have a serious negative impact on patients’facial aesthetics and mental health.The traditional orthodontic treatment strategy often involves extracting 4 first premolars and conventional fixed techniques,combined with mini-implant screws,to retract the anterior teeth and improve facial protrusion.In recent years,an invisible orthodontic technique,without brackets,has become increasingly popular.However,while an invisible aligner has been used in some cases with reasonable results,there remain significant challenges in achieving a perfect outcome.This case report presents an adolescent patient with bimaxillary protrusion and mandibular retrognathia.Based on the characteristics of the invisible aligners and the growth characteristics of the adolescent’s teeth and jawbone,we designed precise three-dimensional tooth movement and corresponding resistance/over-correction for each tooth,while utilizing the patient’s jawbone growth potential to promote rapid development of the mandible,accurately and efficiently correcting bimaxillary protrusion and skeletal mandibular retrognathia.The patient’s facial aesthetics,especially the lateral morphology,have been greatly improved,and various aesthetic indicators have also shown significant changes,and to the patient’s great benefit,invasive mini-implant screws were not used during the treatment.This case highlights the advantages of using invisible aligners in adolescent maxillary protrusion combined with mandibular retraction patients.Furthermore,comprehensive and accurate design combined with good application of growth potential can also enable invisible orthodontic technology to achieve perfect treatment effects in tooth extractions,providing clinical guidance for orthodontists.展开更多
Stemming from the unique in-plane honeycomb lattice structure and the sp^(2)hybridized carbon atoms bonded by exceptionally strong carbon–carbon bonds,graphene exhibits remarkable anisotropic electrical,mechanical,an...Stemming from the unique in-plane honeycomb lattice structure and the sp^(2)hybridized carbon atoms bonded by exceptionally strong carbon–carbon bonds,graphene exhibits remarkable anisotropic electrical,mechanical,and thermal properties.To maximize the utilization of graphene’s in-plane properties,pre-constructed and aligned structures,such as oriented aerogels,films,and fibers,have been designed.The unique combination of aligned structure,high surface area,excellent electrical conductivity,mechanical stability,thermal conductivity,and porous nature of highly aligned graphene aerogels allows for tailored and enhanced performance in specific directions,enabling advancements in diverse fields.This review provides a comprehensive overview of recent advances in highly aligned graphene aerogels and their composites.It highlights the fabrication methods of aligned graphene aerogels and the optimization of alignment which can be estimated both qualitatively and quantitatively.The oriented scaffolds endow graphene aerogels and their composites with anisotropic properties,showing enhanced electrical,mechanical,and thermal properties along the alignment at the sacrifice of the perpendicular direction.This review showcases remarkable properties and applications of aligned graphene aerogels and their composites,such as their suitability for electronics,environmental applications,thermal management,and energy storage.Challenges and potential opportunities are proposed to offer new insights into prospects of this material.展开更多
In wireless communication networks,mobile users in overlapping areas may experience severe interference,therefore,designing effective Interference Management(IM)methods is crucial to improving network performance.Howe...In wireless communication networks,mobile users in overlapping areas may experience severe interference,therefore,designing effective Interference Management(IM)methods is crucial to improving network performance.However,when managing multiple disturbances from the same source,it may not be feasible to use existing IM methods such as Interference Alignment(IA)and Interference Steering(IS)exclusively.It is because with IA,the aligned interference becomes indistinguishable at its desired Receiver(Rx)under the cost constraint of Degrees-of-Freedom(DoF),while with IS,more transmit power will be consumed in the direct and repeated application of IS to each interference.To remedy these deficiencies,Interference Alignment Steering(IAS)is proposed by incorporating IA and IS and exploiting their advantages in IM.With IAS,the interfering Transmitter(Tx)first aligns one interference incurred by the transmission of one data stream to a one-dimensional subspace orthogonal to the desired transmission at the interfered Rx,and then the remaining interferences are treated as a whole and steered to the same subspace as the aligned interference.Moreover,two improved versions of IAS,i.e.,IAS with Full Adjustment at the Interfering Tx(IAS-FAIT)and Interference Steering and Alignment(ISA),are presented.The former considers the influence of IA on the interfering user-pair's performance.The orthogonality between the desired signals at the interfered Rx can be maintained by adjusting the spatial characteristics of all interferences and the aligned interference components,thus ensuring the Spectral Efficiency(SE)of the interfering communication pairs.Under ISA,the power cost for IS at the interfered Tx is minimized,hence improving SE performance of the interfered communication-pairs.Since the proposed methods are realized at the interfering and interfered Txs cooperatively,the expenses of IM are shared by both communication-pairs.Our in-depth simulation results show that joint use of IA and IS can effectively manage multiple disturbances from the same source and improve the system's SE.展开更多
In this paper,an improved spatio-temporal alignment measurement method is presented to address the inertial matching measurement of hull deformation under the coexistence of time delay and large misalignment angle.Lar...In this paper,an improved spatio-temporal alignment measurement method is presented to address the inertial matching measurement of hull deformation under the coexistence of time delay and large misalignment angle.Large misalignment angle and time delay often occur simultaneously and bring great challenges to the accurate measurement of hull deformation in space and time.The proposed method utilizes coarse alignment with large misalignment angle and time delay estimation of inertial measurement unit modeling to establish a brand-new spatiotemporal aligned hull deformation measurement model.In addition,two-step loop control is designed to ensure the accurate description of dynamic deformation angle and static deformation angle by the time-space alignment method of hull deformation.The experiments illustrate that the proposed method can effectively measure the hull deformation angle when time delay and large misalignment angle coexist.展开更多
Beams typically do not travel through the magnet centers because of errors in storage rings.The beam deviating from the quadrupole centers is affected by additional dipole fields due to magnetic field feed-down.Beam-b...Beams typically do not travel through the magnet centers because of errors in storage rings.The beam deviating from the quadrupole centers is affected by additional dipole fields due to magnetic field feed-down.Beam-based alignment(BBA)is often performed to determine a golden orbit where the beam circulates around the quadrupole center axes.For storage rings with many quadrupoles,the conventional BBA procedure is time-consuming,particularly in the commissioning phase,because of the necessary iterative process.In addition,the conventional BBA method can be affected by strong coupling and the nonlinearity of the storage ring optics.In this study,a novel method based on a neural network was proposed to determine the golden orbit in a much shorter time with reasonable accuracy.This golden orbit can be used directly for operation or adopted as a starting point for conventional BBA.The method was demonstrated in the HLS-II storage ring for the first time through simulations and online experiments.The results of the experiments showed that the golden orbit obtained using this new method was consistent with that obtained using the conventional BBA.The development of this new method and the corresponding experiments are reported in this paper.展开更多
Accurate forecasting of time series is crucial across various domains.Many prediction tasks rely on effectively segmenting,matching,and time series data alignment.For instance,regardless of time series with the same g...Accurate forecasting of time series is crucial across various domains.Many prediction tasks rely on effectively segmenting,matching,and time series data alignment.For instance,regardless of time series with the same granularity,segmenting them into different granularity events can effectively mitigate the impact of varying time scales on prediction accuracy.However,these events of varying granularity frequently intersect with each other,which may possess unequal durations.Even minor differences can result in significant errors when matching time series with future trends.Besides,directly using matched events but unaligned events as state vectors in machine learning-based prediction models can lead to insufficient prediction accuracy.Therefore,this paper proposes a short-term forecasting method for time series based on a multi-granularity event,MGE-SP(multi-granularity event-based short-termprediction).First,amethodological framework for MGE-SP established guides the implementation steps.The framework consists of three key steps,including multi-granularity event matching based on the LTF(latest time first)strategy,multi-granularity event alignment using a piecewise aggregate approximation based on the compression ratio,and a short-term prediction model based on XGBoost.The data from a nationwide online car-hailing service in China ensures the method’s reliability.The average RMSE(root mean square error)and MAE(mean absolute error)of the proposed method are 3.204 and 2.360,lower than the respective values of 4.056 and 3.101 obtained using theARIMA(autoregressive integratedmoving average)method,as well as the values of 4.278 and 2.994 obtained using k-means-SVR(support vector regression)method.The other experiment is conducted on stock data froma public data set.The proposed method achieved an average RMSE and MAE of 0.836 and 0.696,lower than the respective values of 1.019 and 0.844 obtained using the ARIMA method,as well as the values of 1.350 and 1.172 obtained using the k-means-SVR method.展开更多
Thermal management of nanoscale quantum dots(QDs)in light-emitting devices is a long-lasting challenge.The existing heat transfer reinforcement solutions for QDs-polymer composite mainly rely on thermal-conductive fil...Thermal management of nanoscale quantum dots(QDs)in light-emitting devices is a long-lasting challenge.The existing heat transfer reinforcement solutions for QDs-polymer composite mainly rely on thermal-conductive fillers.However,this strategy failed to deliver the QDs’heat generation across a long distance,and the accumulated heat still causes considerable temperature rise of QDs-polymer composite,which eventually menaces the performance and reliability of lightemitting devices.Inspired by the radially aligned fruit fibers in oranges,we proposed to eliminate this heat dissipation challenge by establishing long-range ordered heat transfer pathways within the QDs-polymer composite.Ultrahigh molecular weight polyethylene fibers(UPEF)were radially aligned throughout the polymer matrix,thus facilitating massive efficient heat dissipation of the QDs.Under a UPEF filling fraction of 24.46 vol%,the in-plane thermal conductivity of QDs-radially aligned UPEF composite(QDs-RAPE)could reach 10.45 W m^(−1) K^(−1),which is the highest value of QDs-polymer composite reported so far.As a proof of concept,the QDs’working temperature can be reduced by 342.5℃ when illuminated by a highly concentrated laser diode(LD)under driving current of 1000 mA,thus improving their optical performance.This work may pave a new way for next generation high-power QDs lighting applications.展开更多
P-and SV-wave dispersion and attenuation have been extensively investigated in saturated poroelastic media with aligned fractures.However,there are few existing models that incorporate the multiple wave attenuation me...P-and SV-wave dispersion and attenuation have been extensively investigated in saturated poroelastic media with aligned fractures.However,there are few existing models that incorporate the multiple wave attenuation mechanisms from the microscopic scale to the macroscopic scale.Hence,in this work,we developed a unified model to incorporate the wave attenuation mechanisms at different scales,which includes the microscopic squirt flow between the microcracks and pores,the mesoscopic wave-induced fluid flow between fractures and background(FB-WIFF),and the macroscopic Biot's global flow and elastic scattering(ES)from the fractures.Using Tang's modified Biot's theory and the mixed-boundary conditions,we derived the exact frequency-dependent solutions of the scattering problem for a single penny-shaped fracture with oblique incident P-and SV-waves.We then developed theoretical models for a set of aligned fractures and randomly oriented fractures using the Foldy approximation.The results indicated that microcrack squirt flow considerably influences the dispersion and attenuation of P-and SV-wave velocities.The coupling effects of microcrack squirt flow with the FB-WIFF and ES of fractures cause much higher velocity dispersion and attenuation for P waves than for SV waves.Randomly oriented fractures substantially reduce the attenuation caused by the FB-WIFF and ES,particularly for the ES attenuation of SV waves.Through a comparison with existing models in the limiting cases and previous experimental measurements,we validated our model.展开更多
In this paper, we investigate a 1D pressureless Euler-alignment system with a non-local alignment term, describing a kind of self-organizing problem for flocking. As a result, by the transport equation theory and Lagr...In this paper, we investigate a 1D pressureless Euler-alignment system with a non-local alignment term, describing a kind of self-organizing problem for flocking. As a result, by the transport equation theory and Lagrange coordinate transformation, the local well-posedness of the solutions for the 1D pressureless Euler-alignment in Besov spaces with 1≤p∞ is established. Next, the ill-posedness of the solutions for this model in Besov spaces with 1≤p and is also deduced. Finally, the precise blow-up criteria of the solutions for this system is presented in Besov spaces with 1≤p .展开更多
The aim of this study was to evaluate and compare the colour stabilities of three types of orthodontic clear aligners exposed to staining agents in vitro. Sixty clear orthodontic aligners produced by three manufacture...The aim of this study was to evaluate and compare the colour stabilities of three types of orthodontic clear aligners exposed to staining agents in vitro. Sixty clear orthodontic aligners produced by three manufacturers (Invisalign, Angelalign, and Smartee) were immersed in three staining solutions (coffee, black tea, and red wine) and one control solution (distilled water). After 12-h and 7-day immersions, the aligners were washed in an ultrasonic cleaner and measured with a colourimeter. The colour changes (△E*) were calculated on the basis of the Commission Internationale de I'Eclairage L*a*b* colour system (CIE L*a*b*), and the results were then converted into National Bureau of Standards (NBS) units. Fourier transformation infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM) were conducted to observe the molecular and morphologic alterations to the aligner surfaces, respectively. The three types of aligners exhibited slight colour changes after 12 h of staining, with the exception of the Invisalign aligners stained with coffee. The Invisalign aligners exhibited significantly higher AE* values (ranging from 0.30 to 27.81) than those of the Angelalign and Smartee aligners (AE* values ranging from 0.33 to 1.89 and 0.32 to 1.61, respectively, P〈O.05). IFT-IR analysis confirmed that the polymer-based structure of aligners did not exhibit significant chemical differences before and after the immersions. The SEM results revealed different surface alterations to the three types of aligner materials after the 7-day staining. The three types of aesthetic orthodontic appliances exhibited colour stability after the 12-h immersion, with the exception of the Invisalign aligners stained by coffee. The Invisalign aligners were more prone than the Angelalign and Smartee aligners to pigmentation. Aligner materials may be improved by considering aesthetic colour stability properties.展开更多
Observation of unexpectedly large global spin alignment of φ vector mesons in non-central heavy-ion collisions by STAR experiment may reveal the non-perturbative nature of quark interaction in hot matter through fluc...Observation of unexpectedly large global spin alignment of φ vector mesons in non-central heavy-ion collisions by STAR experiment may reveal the non-perturbative nature of quark interaction in hot matter through fluctuating strong force field with short correlation length.展开更多
Objective The aim of the study was to evaluate the coverage of the prostate when prostatic implanted fiducial markers are used to verify setup of the patients in comparison to the pelvic bones while using conebeam com...Objective The aim of the study was to evaluate the coverage of the prostate when prostatic implanted fiducial markers are used to verify setup of the patients in comparison to the pelvic bones while using conebeam computed tomography(CBCT). Methods Seventeen patients with prostate cancer were included. For each patient, daily online CBCT was done. CT planning was matched with CBCT with the help of fiducial markers(3–5 markers) and another matching with done the help of pelvic bony landmarks. Registration of clinical target volume(CTV) 1 including prostate plus seminal vesicles and CTV2 including prostate only was done and were used to confirm the target volume during the process of matching. Delineation of the rectum on every CBCT was done. Two automatic margin representing planning target volume(PTV) were created. PTV1 was generated by adding 1 cm in all directions(PTV1a) and 0.7 cm in the posterior direction(PTV1b). PTV2 was generated by adding 0.5 cm in all directions(PTV2a) and 0.3 cm in the posterior direction(PTV2b). PTV1a was prescribed to receive 46 Gy in conventional fractionation with a boost dose of 30 Gy to PTV1b. The same dose was prescribed to PTV2a and PTV2b. Calculation of the percentage of intersection between CTV1and CTV2 created on CBCT with the original CTV scan was done. A comparison between the two CTVs(CTV1and CTV2) mean dose and the original delineated CTV was done. Then a comparison to the mean dose of the original CTV of PTV1a, PTV2a(CTV1a and CTV2a), and for PTV1b and PTV2b(CTV1b and CTV2b). Calculation of the mean rectal dose and also V60, V70 and V74 was done on the delineated rectum on every CBCT, and then a comparison to the planned original rectal dose. Results The created CTV1and CTV2 intersection percentage with the original CTV1and CTV2 significantly increased by 85%(range, 65%–95%, P < 0.05), when fiducial markers were used. The main difference of the received mean dose was significantly less in comparison to pelvic bone alignment(0.03% to 2% vs 0.03% to 11.6% for PTV1a, P < 0.006;0.01% to 1.8% vs 0.03% to 10.2% for PTV2a, P < 0.014;0.08 to 2.11 vs 0.04 to 11.29 for PTV1b, P < 0.015 and 0.01 to 1.79 vs 0.01 to 9.69 for PTV2b, P < 0.004). With the use of less PTV margins, significant decrease of the rectal mean dose, V60, V70 and V74 by P < 0.004, P < 0.004, P < 0.0005 and P < 0.009, respectively. Reduction of the CTV1a and CTV1b mean dose by 1.13% and 0.28% in comparison to the initial CTV1a and CTV2a.Conclusion A significant improvement of prostatic cancer patients alignment when fiducial markers are used, with more homogenous dose distribution, and with significant decrease in PTV margins. The delivered rectal dose is significantly less allowing prostate dose escalation.展开更多
Bioprinting has been widely investigated for tissue engineering and regenerative medicine applications.However,it is still difficult to reconstruct the complex native cell arrangement due to the limited printing resol...Bioprinting has been widely investigated for tissue engineering and regenerative medicine applications.However,it is still difficult to reconstruct the complex native cell arrangement due to the limited printing resolution of conventional bioprinting techniques such as extrusion-and inkjet-based printing.Recently,an electrohydrodynamic(EHD)bioprinting strategy was reported for the precise deposition of well-organized cell-laden constructs with microscale filament size,whereas few studies have been devoted to developing bioinks that can be applied for EHD bioprinting and simultaneously support cell spreading.This study describes functionalized alginate-based bioinks for microscale EHD bioprinting using peptide grafting and fibrin incorporation,which leads to high cell viability(>90%)and cell spreading.The printed filaments can be further refined to as small as 30μm by incorporating polyoxyethylene and remained stable over one week when exposed to an aqueous environment.By utilizing the presented alginate-based bioinks,layer-specific cell alignment along the printing struts could be observed inside the EHD-printed microscale filaments,which allows fabricating living constructs with cell-scale filament resolution for guided cellular orientation.展开更多
A deep learning-based automated Kirkpatrick-Baez mirror alignment method is proposed for synchrotron radiation.We trained a convolutional neural network(CNN)on simulated and experimental imaging data of a focusing sys...A deep learning-based automated Kirkpatrick-Baez mirror alignment method is proposed for synchrotron radiation.We trained a convolutional neural network(CNN)on simulated and experimental imaging data of a focusing system.Instead of learning directly from bypass images,we use a scatterer for X-ray modulation and speckle generation for image feature enhancement.The smallest normalized root-mean-square error on the validation set was 4%.Compared with conventional alignment methods based on motor scanning and analyzer setups,the present method simplified the optical layout and estimated alignment errors using a single-exposure experiment.Single-shot misalignment error estimation only took 0.13 s,significantly outperforming conventional methods.We also demonstrated the effects of the beam quality and pretraining using experimental data.The proposed method exhibited strong robustness,can handle high-precision focusing systems with complex or dynamic wavefront errors,and provides an important basis for intelligent control of future synchrotron radiation beamlines.展开更多
Low-noise high-stability current sources have essential applications such as neutron electric dipole moment measurement and high-stability magnetometers. Previous studies mainly focused on frequency noise above 0.1 Hz...Low-noise high-stability current sources have essential applications such as neutron electric dipole moment measurement and high-stability magnetometers. Previous studies mainly focused on frequency noise above 0.1 Hz while less on the low-frequency noise/drift. We use double resonance alignment magnetometers(DRAMs) to measure and suppress the low-frequency noise of a homemade current source(CS) board. The CS board noise level is suppressed by about 10 times in the range of 0.001-0.1 Hz and is reduced to 100 n A/√Hz at 0.001 Hz. The relative stability of CS board can reach2.2 × 10^(-8). In addition, the DRAM shows a better resolution and accuracy than a commercial 7.5-digit multimeter when measuring our homemade CS board. Further, by combining the DRAM with a double resonance orientation magnetometer,we may realize a low-noise CS in the 0.001-1000 Hz range.展开更多
Advancements in next-generation sequencer(NGS)platforms have improved NGS sequence data production and reduced the cost involved,which has resulted in the production of a large amount of genome data.The downstream ana...Advancements in next-generation sequencer(NGS)platforms have improved NGS sequence data production and reduced the cost involved,which has resulted in the production of a large amount of genome data.The downstream analysis of multiple associated sequences has become a bottleneck for the growing genomic data due to storage and space utilization issues in the domain of bioinformatics.The traditional string-matching algorithms are efficient for small sized data sequences and cannot process large amounts of data for downstream analysis.This study proposes a novel bit-parallelism algorithm called BitmapAligner to overcome the issues faced due to a large number of sequences and to improve the speed and quality of multiple sequence alignment(MSA).The input files(sequences)tested over BitmapAligner can be easily managed and organized using the Hadoop distributed file system.The proposed aligner converts the test file(the whole genome sequence)into binaries of an equal length of the sequence,line by line,before the sequence alignment processing.The Hadoop distributed file system splits the larger files into blocks,based on a defined block size,which is 128 MB by default.BitmapAligner can accurately process the sequence alignment using the bitmask approach on large-scale sequences after sorting the data.The experimental results indicate that BitmapAligner operates in real time,with a large number of sequences.Moreover,BitmapAligner achieves the exact start and end positions of the pattern sequence to test the MSA application in the whole genome query sequence.The MSA’s accuracy is verified by the bitmask indexing property of the bit-parallelism extended shifts(BXS)algorithm.The dynamic and exact approach of the BXS algorithm is implemented through the MapReduce function of Apache Hadoop.Conversely,the traditional seeds-and-extend approach faces the risk of errors while identifying the pattern sequences’positions.Moreover,the proposed model resolves the largescale data challenges that are covered through MapReduce in the Hadoop framework.Hive,Yarn,HBase,Cassandra,and many other pertinent flavors are to be used in the future for data structuring and annotations on the top layer of Hadoop since Hadoop is primarily used for data organization and handles text documents.展开更多
The anisotropic absorption and emission from semiconductor CdSe/CdS quantum rods(QRs)provide extra benefits among other photoluminescence nanocrystals.Using photo-induced alignment technique,the QRs can be oriented in...The anisotropic absorption and emission from semiconductor CdSe/CdS quantum rods(QRs)provide extra benefits among other photoluminescence nanocrystals.Using photo-induced alignment technique,the QRs can be oriented in liquid crystal polymer matrix at a large scale.In this article,a 2D Dammann grating pattern,within“SKL”characters domains aligned QRs in composite film,was fabricated by multi-step photo exposure using several photo masks,and a continuous geometric lens profile pattern aligned QRs was realized by the single step polarization converting holographic irradiation method.Both polarized optical microscope and fluorescence microscope are employed to determine the liquid crystal director profiles and QRs anisotropic excitation properties.We have been able to orient the QRs in fine binary and continuous patterns that confirms the strong quantum rod aligning ability of the proposed method.Thus,the proposed approach paves a way for photoinduced flexible QRs alignments to provide a highly specific and difficult-to-replicate security application at a large scale.展开更多
The contamination of Atlantic salmon with severe acute respiratory syndrome coronavirus 2(SARS-CoV-2)has impeded the development of the cold-chain food industry and posed possible risks to the population.Electron beam...The contamination of Atlantic salmon with severe acute respiratory syndrome coronavirus 2(SARS-CoV-2)has impeded the development of the cold-chain food industry and posed possible risks to the population.Electron beam(E-beam)irradiation under 2,4,7,and 10 kGy can effectively inactivate SARS-CoV-2 in cold-chain seafood.However,there are few statistics about the quality changes of salmon exposed to these irradiation dosages.This work demonstrated that E-beam irradiation at dosages capable of killing SARS-CoV-2 induced lipid oxidation,decreased vitamin A content,and increased some amino acids and ash content.In addition,irradiation altered the textural features of salmon,such as its hardness,resilience,cohesiveness,and chewiness.The irradiation considerably affected the L*,a*,and b*values of salmon,with the L*value increasing and a*,b*values decreasing.There was no significant difference in the sensory evaluation of control and irradiated salmon.It was shown that irradiation with 2−7 kGy E-beam did not significantly degrade quality.The inactivation of SARS-CoV-2 in salmon is advised at a dose of 2 kGy.展开更多
Mechanically aligned total knee arthroplasty (TKA) for valgus knee is considered a “challenging surgery.” Recently, the kinematic alignment (KA) method has gained attention. This study aimed to present objective cli...Mechanically aligned total knee arthroplasty (TKA) for valgus knee is considered a “challenging surgery.” Recently, the kinematic alignment (KA) method has gained attention. This study aimed to present objective clinical data, such as intraoperative balance assessment and radiographic evaluation of postoperative lower extremity alignment after TKA using the KA method for valgus deformity. Twenty-one TKA knees (mean age, 74 years;2 males, 19 females) with KA for severe valgus deformity (hip-knee-ankle-angle ≥ 10°) performed at our department in the past 3 years were included in this study. Intraoperative gap and balance measurements and postoperative radiographic evaluation were performed. A total arc of range of motion was achieved up to 98% of preoperative values at 3 weeks postoperatively. Intraoperative gap and balance were stable throughout the entire range of motion. In addition, there were no statistically significant differences in either balance or gap values at each flexion angle. KA TKA is a “simple surgery” rather than a “challenging surgery” because additional soft tissue procedures are not required, operative time is short, intraoperative and postoperative balance is very stable, and a good alignment is achieved. This procedure may relieve surgeons of the stress of TKA for valgus deformities.展开更多
基金supported by grants from the Interdisciplinary Program of Wuhan National High Magnetic Field Center(No.WHMFC202207)China Oral Health Foundation(No.A2023-009).
文摘Maxillary protrusion combined with mandibular retraction is a highly prevalent but extremely complex maxillofacial deformity that can have a serious negative impact on patients’facial aesthetics and mental health.The traditional orthodontic treatment strategy often involves extracting 4 first premolars and conventional fixed techniques,combined with mini-implant screws,to retract the anterior teeth and improve facial protrusion.In recent years,an invisible orthodontic technique,without brackets,has become increasingly popular.However,while an invisible aligner has been used in some cases with reasonable results,there remain significant challenges in achieving a perfect outcome.This case report presents an adolescent patient with bimaxillary protrusion and mandibular retrognathia.Based on the characteristics of the invisible aligners and the growth characteristics of the adolescent’s teeth and jawbone,we designed precise three-dimensional tooth movement and corresponding resistance/over-correction for each tooth,while utilizing the patient’s jawbone growth potential to promote rapid development of the mandible,accurately and efficiently correcting bimaxillary protrusion and skeletal mandibular retrognathia.The patient’s facial aesthetics,especially the lateral morphology,have been greatly improved,and various aesthetic indicators have also shown significant changes,and to the patient’s great benefit,invasive mini-implant screws were not used during the treatment.This case highlights the advantages of using invisible aligners in adolescent maxillary protrusion combined with mandibular retraction patients.Furthermore,comprehensive and accurate design combined with good application of growth potential can also enable invisible orthodontic technology to achieve perfect treatment effects in tooth extractions,providing clinical guidance for orthodontists.
基金The financial support by the National Natural Science Foundation of China(No.52002020)is acknowledged.
文摘Stemming from the unique in-plane honeycomb lattice structure and the sp^(2)hybridized carbon atoms bonded by exceptionally strong carbon–carbon bonds,graphene exhibits remarkable anisotropic electrical,mechanical,and thermal properties.To maximize the utilization of graphene’s in-plane properties,pre-constructed and aligned structures,such as oriented aerogels,films,and fibers,have been designed.The unique combination of aligned structure,high surface area,excellent electrical conductivity,mechanical stability,thermal conductivity,and porous nature of highly aligned graphene aerogels allows for tailored and enhanced performance in specific directions,enabling advancements in diverse fields.This review provides a comprehensive overview of recent advances in highly aligned graphene aerogels and their composites.It highlights the fabrication methods of aligned graphene aerogels and the optimization of alignment which can be estimated both qualitatively and quantitatively.The oriented scaffolds endow graphene aerogels and their composites with anisotropic properties,showing enhanced electrical,mechanical,and thermal properties along the alignment at the sacrifice of the perpendicular direction.This review showcases remarkable properties and applications of aligned graphene aerogels and their composites,such as their suitability for electronics,environmental applications,thermal management,and energy storage.Challenges and potential opportunities are proposed to offer new insights into prospects of this material.
基金supported in part by NSF of Shaanxi Province under Grant 2021JM-143the Fundamental Research Funds for the Central Universities under Grant JB211502+5 种基金the Project of Key Laboratory of Science&Technology on Communication Network under Grant 6142104200412the National Natural Science Foundation of China under Grant 62072351the Academy of Finland under Grant 308087,Grant 335262 and Grant 345072the Shaanxi Innovation Team Project under Grant 2018TD-007the 111 Project under Grant B16037,JSPS KAKENHI Grant Number JP20K14742the Project of Cyber Security Establishment with Inter University Cooperation.
文摘In wireless communication networks,mobile users in overlapping areas may experience severe interference,therefore,designing effective Interference Management(IM)methods is crucial to improving network performance.However,when managing multiple disturbances from the same source,it may not be feasible to use existing IM methods such as Interference Alignment(IA)and Interference Steering(IS)exclusively.It is because with IA,the aligned interference becomes indistinguishable at its desired Receiver(Rx)under the cost constraint of Degrees-of-Freedom(DoF),while with IS,more transmit power will be consumed in the direct and repeated application of IS to each interference.To remedy these deficiencies,Interference Alignment Steering(IAS)is proposed by incorporating IA and IS and exploiting their advantages in IM.With IAS,the interfering Transmitter(Tx)first aligns one interference incurred by the transmission of one data stream to a one-dimensional subspace orthogonal to the desired transmission at the interfered Rx,and then the remaining interferences are treated as a whole and steered to the same subspace as the aligned interference.Moreover,two improved versions of IAS,i.e.,IAS with Full Adjustment at the Interfering Tx(IAS-FAIT)and Interference Steering and Alignment(ISA),are presented.The former considers the influence of IA on the interfering user-pair's performance.The orthogonality between the desired signals at the interfered Rx can be maintained by adjusting the spatial characteristics of all interferences and the aligned interference components,thus ensuring the Spectral Efficiency(SE)of the interfering communication pairs.Under ISA,the power cost for IS at the interfered Tx is minimized,hence improving SE performance of the interfered communication-pairs.Since the proposed methods are realized at the interfering and interfered Txs cooperatively,the expenses of IM are shared by both communication-pairs.Our in-depth simulation results show that joint use of IA and IS can effectively manage multiple disturbances from the same source and improve the system's SE.
基金supported by Beijing Insititute of Technology Research Fund Program for Young Scholars(2020X04104)。
文摘In this paper,an improved spatio-temporal alignment measurement method is presented to address the inertial matching measurement of hull deformation under the coexistence of time delay and large misalignment angle.Large misalignment angle and time delay often occur simultaneously and bring great challenges to the accurate measurement of hull deformation in space and time.The proposed method utilizes coarse alignment with large misalignment angle and time delay estimation of inertial measurement unit modeling to establish a brand-new spatiotemporal aligned hull deformation measurement model.In addition,two-step loop control is designed to ensure the accurate description of dynamic deformation angle and static deformation angle by the time-space alignment method of hull deformation.The experiments illustrate that the proposed method can effectively measure the hull deformation angle when time delay and large misalignment angle coexist.
基金supported by the National Natural Science Foundation of China(No.11975227)。
文摘Beams typically do not travel through the magnet centers because of errors in storage rings.The beam deviating from the quadrupole centers is affected by additional dipole fields due to magnetic field feed-down.Beam-based alignment(BBA)is often performed to determine a golden orbit where the beam circulates around the quadrupole center axes.For storage rings with many quadrupoles,the conventional BBA procedure is time-consuming,particularly in the commissioning phase,because of the necessary iterative process.In addition,the conventional BBA method can be affected by strong coupling and the nonlinearity of the storage ring optics.In this study,a novel method based on a neural network was proposed to determine the golden orbit in a much shorter time with reasonable accuracy.This golden orbit can be used directly for operation or adopted as a starting point for conventional BBA.The method was demonstrated in the HLS-II storage ring for the first time through simulations and online experiments.The results of the experiments showed that the golden orbit obtained using this new method was consistent with that obtained using the conventional BBA.The development of this new method and the corresponding experiments are reported in this paper.
基金funded by the Fujian Province Science and Technology Plan,China(Grant Number 2019H0017).
文摘Accurate forecasting of time series is crucial across various domains.Many prediction tasks rely on effectively segmenting,matching,and time series data alignment.For instance,regardless of time series with the same granularity,segmenting them into different granularity events can effectively mitigate the impact of varying time scales on prediction accuracy.However,these events of varying granularity frequently intersect with each other,which may possess unequal durations.Even minor differences can result in significant errors when matching time series with future trends.Besides,directly using matched events but unaligned events as state vectors in machine learning-based prediction models can lead to insufficient prediction accuracy.Therefore,this paper proposes a short-term forecasting method for time series based on a multi-granularity event,MGE-SP(multi-granularity event-based short-termprediction).First,amethodological framework for MGE-SP established guides the implementation steps.The framework consists of three key steps,including multi-granularity event matching based on the LTF(latest time first)strategy,multi-granularity event alignment using a piecewise aggregate approximation based on the compression ratio,and a short-term prediction model based on XGBoost.The data from a nationwide online car-hailing service in China ensures the method’s reliability.The average RMSE(root mean square error)and MAE(mean absolute error)of the proposed method are 3.204 and 2.360,lower than the respective values of 4.056 and 3.101 obtained using theARIMA(autoregressive integratedmoving average)method,as well as the values of 4.278 and 2.994 obtained using k-means-SVR(support vector regression)method.The other experiment is conducted on stock data froma public data set.The proposed method achieved an average RMSE and MAE of 0.836 and 0.696,lower than the respective values of 1.019 and 0.844 obtained using the ARIMA method,as well as the values of 1.350 and 1.172 obtained using the k-means-SVR method.
基金supported by the National Natural Science Foundation of China(52106089).
文摘Thermal management of nanoscale quantum dots(QDs)in light-emitting devices is a long-lasting challenge.The existing heat transfer reinforcement solutions for QDs-polymer composite mainly rely on thermal-conductive fillers.However,this strategy failed to deliver the QDs’heat generation across a long distance,and the accumulated heat still causes considerable temperature rise of QDs-polymer composite,which eventually menaces the performance and reliability of lightemitting devices.Inspired by the radially aligned fruit fibers in oranges,we proposed to eliminate this heat dissipation challenge by establishing long-range ordered heat transfer pathways within the QDs-polymer composite.Ultrahigh molecular weight polyethylene fibers(UPEF)were radially aligned throughout the polymer matrix,thus facilitating massive efficient heat dissipation of the QDs.Under a UPEF filling fraction of 24.46 vol%,the in-plane thermal conductivity of QDs-radially aligned UPEF composite(QDs-RAPE)could reach 10.45 W m^(−1) K^(−1),which is the highest value of QDs-polymer composite reported so far.As a proof of concept,the QDs’working temperature can be reduced by 342.5℃ when illuminated by a highly concentrated laser diode(LD)under driving current of 1000 mA,thus improving their optical performance.This work may pave a new way for next generation high-power QDs lighting applications.
基金This work was supported by the Laoshan National Laboratory Science and Technology Innovation Project(No.LSKJ202203407)the National Natural Science Foundation of China(Grant Nos.42174145,41821002,42274146)+1 种基金Guangdong Provincial Key Laboratory of Geophysical High-resolution Imaging Technology(2022B1212010002)Shenzhen Stable Support Plan Program for Higher Education Institutions(20220815110144003).
文摘P-and SV-wave dispersion and attenuation have been extensively investigated in saturated poroelastic media with aligned fractures.However,there are few existing models that incorporate the multiple wave attenuation mechanisms from the microscopic scale to the macroscopic scale.Hence,in this work,we developed a unified model to incorporate the wave attenuation mechanisms at different scales,which includes the microscopic squirt flow between the microcracks and pores,the mesoscopic wave-induced fluid flow between fractures and background(FB-WIFF),and the macroscopic Biot's global flow and elastic scattering(ES)from the fractures.Using Tang's modified Biot's theory and the mixed-boundary conditions,we derived the exact frequency-dependent solutions of the scattering problem for a single penny-shaped fracture with oblique incident P-and SV-waves.We then developed theoretical models for a set of aligned fractures and randomly oriented fractures using the Foldy approximation.The results indicated that microcrack squirt flow considerably influences the dispersion and attenuation of P-and SV-wave velocities.The coupling effects of microcrack squirt flow with the FB-WIFF and ES of fractures cause much higher velocity dispersion and attenuation for P waves than for SV waves.Randomly oriented fractures substantially reduce the attenuation caused by the FB-WIFF and ES,particularly for the ES attenuation of SV waves.Through a comparison with existing models in the limiting cases and previous experimental measurements,we validated our model.
文摘In this paper, we investigate a 1D pressureless Euler-alignment system with a non-local alignment term, describing a kind of self-organizing problem for flocking. As a result, by the transport equation theory and Lagrange coordinate transformation, the local well-posedness of the solutions for the 1D pressureless Euler-alignment in Besov spaces with 1≤p∞ is established. Next, the ill-posedness of the solutions for this model in Besov spaces with 1≤p and is also deduced. Finally, the precise blow-up criteria of the solutions for this system is presented in Besov spaces with 1≤p .
基金funded by the Orthodontic National Key Clinical Specialty Construction Program of Chinathe West China Hospital of Stomatology Sichuan Universitysupported by grants from the National Natural Science Foundation of China (Grant No. 31470904 and 81470722)
文摘The aim of this study was to evaluate and compare the colour stabilities of three types of orthodontic clear aligners exposed to staining agents in vitro. Sixty clear orthodontic aligners produced by three manufacturers (Invisalign, Angelalign, and Smartee) were immersed in three staining solutions (coffee, black tea, and red wine) and one control solution (distilled water). After 12-h and 7-day immersions, the aligners were washed in an ultrasonic cleaner and measured with a colourimeter. The colour changes (△E*) were calculated on the basis of the Commission Internationale de I'Eclairage L*a*b* colour system (CIE L*a*b*), and the results were then converted into National Bureau of Standards (NBS) units. Fourier transformation infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM) were conducted to observe the molecular and morphologic alterations to the aligner surfaces, respectively. The three types of aligners exhibited slight colour changes after 12 h of staining, with the exception of the Invisalign aligners stained with coffee. The Invisalign aligners exhibited significantly higher AE* values (ranging from 0.30 to 27.81) than those of the Angelalign and Smartee aligners (AE* values ranging from 0.33 to 1.89 and 0.32 to 1.61, respectively, P〈O.05). IFT-IR analysis confirmed that the polymer-based structure of aligners did not exhibit significant chemical differences before and after the immersions. The SEM results revealed different surface alterations to the three types of aligner materials after the 7-day staining. The three types of aesthetic orthodontic appliances exhibited colour stability after the 12-h immersion, with the exception of the Invisalign aligners stained by coffee. The Invisalign aligners were more prone than the Angelalign and Smartee aligners to pigmentation. Aligner materials may be improved by considering aesthetic colour stability properties.
文摘Observation of unexpectedly large global spin alignment of φ vector mesons in non-central heavy-ion collisions by STAR experiment may reveal the non-perturbative nature of quark interaction in hot matter through fluctuating strong force field with short correlation length.
文摘Objective The aim of the study was to evaluate the coverage of the prostate when prostatic implanted fiducial markers are used to verify setup of the patients in comparison to the pelvic bones while using conebeam computed tomography(CBCT). Methods Seventeen patients with prostate cancer were included. For each patient, daily online CBCT was done. CT planning was matched with CBCT with the help of fiducial markers(3–5 markers) and another matching with done the help of pelvic bony landmarks. Registration of clinical target volume(CTV) 1 including prostate plus seminal vesicles and CTV2 including prostate only was done and were used to confirm the target volume during the process of matching. Delineation of the rectum on every CBCT was done. Two automatic margin representing planning target volume(PTV) were created. PTV1 was generated by adding 1 cm in all directions(PTV1a) and 0.7 cm in the posterior direction(PTV1b). PTV2 was generated by adding 0.5 cm in all directions(PTV2a) and 0.3 cm in the posterior direction(PTV2b). PTV1a was prescribed to receive 46 Gy in conventional fractionation with a boost dose of 30 Gy to PTV1b. The same dose was prescribed to PTV2a and PTV2b. Calculation of the percentage of intersection between CTV1and CTV2 created on CBCT with the original CTV scan was done. A comparison between the two CTVs(CTV1and CTV2) mean dose and the original delineated CTV was done. Then a comparison to the mean dose of the original CTV of PTV1a, PTV2a(CTV1a and CTV2a), and for PTV1b and PTV2b(CTV1b and CTV2b). Calculation of the mean rectal dose and also V60, V70 and V74 was done on the delineated rectum on every CBCT, and then a comparison to the planned original rectal dose. Results The created CTV1and CTV2 intersection percentage with the original CTV1and CTV2 significantly increased by 85%(range, 65%–95%, P < 0.05), when fiducial markers were used. The main difference of the received mean dose was significantly less in comparison to pelvic bone alignment(0.03% to 2% vs 0.03% to 11.6% for PTV1a, P < 0.006;0.01% to 1.8% vs 0.03% to 10.2% for PTV2a, P < 0.014;0.08 to 2.11 vs 0.04 to 11.29 for PTV1b, P < 0.015 and 0.01 to 1.79 vs 0.01 to 9.69 for PTV2b, P < 0.004). With the use of less PTV margins, significant decrease of the rectal mean dose, V60, V70 and V74 by P < 0.004, P < 0.004, P < 0.0005 and P < 0.009, respectively. Reduction of the CTV1a and CTV1b mean dose by 1.13% and 0.28% in comparison to the initial CTV1a and CTV2a.Conclusion A significant improvement of prostatic cancer patients alignment when fiducial markers are used, with more homogenous dose distribution, and with significant decrease in PTV margins. The delivered rectal dose is significantly less allowing prostate dose escalation.
基金This work was financially supported by the National Key Research and Development Program of China(No.2018YFA0703003)the National Natural Science Foundation of China(No.52125501)+1 种基金the Key Research Project of Shaanxi Province(Nos.2021LLRH-08,2020GXLH-Y-021,and 2021GXLH-Z-028)the Youth InnovationTeam of Shaanxi Universities and the Fundamental Research Funds for the Central Universities.
文摘Bioprinting has been widely investigated for tissue engineering and regenerative medicine applications.However,it is still difficult to reconstruct the complex native cell arrangement due to the limited printing resolution of conventional bioprinting techniques such as extrusion-and inkjet-based printing.Recently,an electrohydrodynamic(EHD)bioprinting strategy was reported for the precise deposition of well-organized cell-laden constructs with microscale filament size,whereas few studies have been devoted to developing bioinks that can be applied for EHD bioprinting and simultaneously support cell spreading.This study describes functionalized alginate-based bioinks for microscale EHD bioprinting using peptide grafting and fibrin incorporation,which leads to high cell viability(>90%)and cell spreading.The printed filaments can be further refined to as small as 30μm by incorporating polyoxyethylene and remained stable over one week when exposed to an aqueous environment.By utilizing the presented alginate-based bioinks,layer-specific cell alignment along the printing struts could be observed inside the EHD-printed microscale filaments,which allows fabricating living constructs with cell-scale filament resolution for guided cellular orientation.
基金supported by the National Key Research and Development Program(No.2021YFA1601000)National Natural Science Foundation of China(No.12175294)Natural Science Foundation of Shanghai,China(No.21ZR1471500).
文摘A deep learning-based automated Kirkpatrick-Baez mirror alignment method is proposed for synchrotron radiation.We trained a convolutional neural network(CNN)on simulated and experimental imaging data of a focusing system.Instead of learning directly from bypass images,we use a scatterer for X-ray modulation and speckle generation for image feature enhancement.The smallest normalized root-mean-square error on the validation set was 4%.Compared with conventional alignment methods based on motor scanning and analyzer setups,the present method simplified the optical layout and estimated alignment errors using a single-exposure experiment.Single-shot misalignment error estimation only took 0.13 s,significantly outperforming conventional methods.We also demonstrated the effects of the beam quality and pretraining using experimental data.The proposed method exhibited strong robustness,can handle high-precision focusing systems with complex or dynamic wavefront errors,and provides an important basis for intelligent control of future synchrotron radiation beamlines.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 12174446 and 61671458)。
文摘Low-noise high-stability current sources have essential applications such as neutron electric dipole moment measurement and high-stability magnetometers. Previous studies mainly focused on frequency noise above 0.1 Hz while less on the low-frequency noise/drift. We use double resonance alignment magnetometers(DRAMs) to measure and suppress the low-frequency noise of a homemade current source(CS) board. The CS board noise level is suppressed by about 10 times in the range of 0.001-0.1 Hz and is reduced to 100 n A/√Hz at 0.001 Hz. The relative stability of CS board can reach2.2 × 10^(-8). In addition, the DRAM shows a better resolution and accuracy than a commercial 7.5-digit multimeter when measuring our homemade CS board. Further, by combining the DRAM with a double resonance orientation magnetometer,we may realize a low-noise CS in the 0.001-1000 Hz range.
基金This work was supported in part by the National Research Foundation of Korea(NRF)grant funded by the Korea government(MSIT)(No.2018R1C1B5084424)in part by the Basic Science Research Program through the National Research Foundation of Korea(NRF)funded by the Ministry of Education(No.2019R1A6A1A03032119).
文摘Advancements in next-generation sequencer(NGS)platforms have improved NGS sequence data production and reduced the cost involved,which has resulted in the production of a large amount of genome data.The downstream analysis of multiple associated sequences has become a bottleneck for the growing genomic data due to storage and space utilization issues in the domain of bioinformatics.The traditional string-matching algorithms are efficient for small sized data sequences and cannot process large amounts of data for downstream analysis.This study proposes a novel bit-parallelism algorithm called BitmapAligner to overcome the issues faced due to a large number of sequences and to improve the speed and quality of multiple sequence alignment(MSA).The input files(sequences)tested over BitmapAligner can be easily managed and organized using the Hadoop distributed file system.The proposed aligner converts the test file(the whole genome sequence)into binaries of an equal length of the sequence,line by line,before the sequence alignment processing.The Hadoop distributed file system splits the larger files into blocks,based on a defined block size,which is 128 MB by default.BitmapAligner can accurately process the sequence alignment using the bitmask approach on large-scale sequences after sorting the data.The experimental results indicate that BitmapAligner operates in real time,with a large number of sequences.Moreover,BitmapAligner achieves the exact start and end positions of the pattern sequence to test the MSA application in the whole genome query sequence.The MSA’s accuracy is verified by the bitmask indexing property of the bit-parallelism extended shifts(BXS)algorithm.The dynamic and exact approach of the BXS algorithm is implemented through the MapReduce function of Apache Hadoop.Conversely,the traditional seeds-and-extend approach faces the risk of errors while identifying the pattern sequences’positions.Moreover,the proposed model resolves the largescale data challenges that are covered through MapReduce in the Hadoop framework.Hive,Yarn,HBase,Cassandra,and many other pertinent flavors are to be used in the future for data structuring and annotations on the top layer of Hadoop since Hadoop is primarily used for data organization and handles text documents.
基金supported by the Guangdong Major Project of Basic and Applied Basic Research(No.2020B0301030009)the National Natural Science Foundation of China(Nos.62005180,61935013)+2 种基金the Zhejiang Lab Open Research Project(No.K2022MG0AB01)RGC of Hong Kong S.A.R.(No.26202019)the State Key Laboratory of Advanced Displays and Optoelectronics Technologies(HKUST)(No.ITC-PSKL12EG02)。
文摘The anisotropic absorption and emission from semiconductor CdSe/CdS quantum rods(QRs)provide extra benefits among other photoluminescence nanocrystals.Using photo-induced alignment technique,the QRs can be oriented in liquid crystal polymer matrix at a large scale.In this article,a 2D Dammann grating pattern,within“SKL”characters domains aligned QRs in composite film,was fabricated by multi-step photo exposure using several photo masks,and a continuous geometric lens profile pattern aligned QRs was realized by the single step polarization converting holographic irradiation method.Both polarized optical microscope and fluorescence microscope are employed to determine the liquid crystal director profiles and QRs anisotropic excitation properties.We have been able to orient the QRs in fine binary and continuous patterns that confirms the strong quantum rod aligning ability of the proposed method.Thus,the proposed approach paves a way for photoinduced flexible QRs alignments to provide a highly specific and difficult-to-replicate security application at a large scale.
基金the grants from Hangzhou Global Scientific and Technological Innovation Center of Zhejiang University(KC2021ZY0B0003).
文摘The contamination of Atlantic salmon with severe acute respiratory syndrome coronavirus 2(SARS-CoV-2)has impeded the development of the cold-chain food industry and posed possible risks to the population.Electron beam(E-beam)irradiation under 2,4,7,and 10 kGy can effectively inactivate SARS-CoV-2 in cold-chain seafood.However,there are few statistics about the quality changes of salmon exposed to these irradiation dosages.This work demonstrated that E-beam irradiation at dosages capable of killing SARS-CoV-2 induced lipid oxidation,decreased vitamin A content,and increased some amino acids and ash content.In addition,irradiation altered the textural features of salmon,such as its hardness,resilience,cohesiveness,and chewiness.The irradiation considerably affected the L*,a*,and b*values of salmon,with the L*value increasing and a*,b*values decreasing.There was no significant difference in the sensory evaluation of control and irradiated salmon.It was shown that irradiation with 2−7 kGy E-beam did not significantly degrade quality.The inactivation of SARS-CoV-2 in salmon is advised at a dose of 2 kGy.
文摘Mechanically aligned total knee arthroplasty (TKA) for valgus knee is considered a “challenging surgery.” Recently, the kinematic alignment (KA) method has gained attention. This study aimed to present objective clinical data, such as intraoperative balance assessment and radiographic evaluation of postoperative lower extremity alignment after TKA using the KA method for valgus deformity. Twenty-one TKA knees (mean age, 74 years;2 males, 19 females) with KA for severe valgus deformity (hip-knee-ankle-angle ≥ 10°) performed at our department in the past 3 years were included in this study. Intraoperative gap and balance measurements and postoperative radiographic evaluation were performed. A total arc of range of motion was achieved up to 98% of preoperative values at 3 weeks postoperatively. Intraoperative gap and balance were stable throughout the entire range of motion. In addition, there were no statistically significant differences in either balance or gap values at each flexion angle. KA TKA is a “simple surgery” rather than a “challenging surgery” because additional soft tissue procedures are not required, operative time is short, intraoperative and postoperative balance is very stable, and a good alignment is achieved. This procedure may relieve surgeons of the stress of TKA for valgus deformities.