This paper introduces some latest developments regarding the X-ray imaging methodology and applications of the X-ray imaging and biomedical application beamline(BL13W1)at Shanghai Synchrotron Radiation Facility in the...This paper introduces some latest developments regarding the X-ray imaging methodology and applications of the X-ray imaging and biomedical application beamline(BL13W1)at Shanghai Synchrotron Radiation Facility in the past 5 years.The photon energy range of the beamline is 8–72.5 keV.Several sets of X-ray imaging detectors with different pixel sizes(0.19–24 lm)are used to realize X-ray microcomputed tomography(X-ray micro-CT)and X-ray in-line phase-contrast imaging.To satisfy the requirements of user experiments,new X-ray imaging methods and image processing techniques are developed.In vivo dynamic micro-CT experiments with living insects are performed in 0.5 s(sampling rate of 2 Hz,2 tomograms/s)with a monochromatic beam from a wiggler source and in 40 ms(sampling rate of 25 Hz,25 tomograms/s)with a white beam from a bending magnet source.A new X-ray imaging method known as move contrast X-ray imaging is proposed,with which blood flow and moving tissues in raw images can be distinguished according to their moving frequencies in the time domain.Furthermore,X-ray speckle-tracking imaging with twice exposures to eliminate the edge enhancement effect is developed.A high-precision quantification method is realized to measure complex three-dimensional blood vessels obtained via X-ray micro-CT.X-ray imaging methods such as three-dimensional X-ray diffraction microscopy,small-angle X-ray scattering CT,and X-ray fluorescence CT are developed,in which the X-ray micro-CT imaging method is combined with other contrast mechanisms such as diffraction,scattering,and fluorescence contrasts respectively.Moreover,an X-ray nano-CT experiment is performed with a 100 nm spatial resolution.Typical user experimental results from the fields of material science,biomedicine,paleontology,physics,chemistry,and environmental science obtained on the beamline are provided.展开更多
The use of speckle-tracking echocardiography(STE)is becoming an increasingly useful tool in the evaluation of myocardial disease.STE software can track the motion of the specular pattern created by the interference of...The use of speckle-tracking echocardiography(STE)is becoming an increasingly useful tool in the evaluation of myocardial disease.STE software can track the motion of the specular pattern created by the interference of ultrasound with the myofibers of the heart and provide a quantitative means to evaluate subtle changes in ventricular function that often occur before changes in ventricular ejection fraction are observed.STE is most often used to measure the change in shape(strain)of myocardial segments in the circumferential,radial,and longitudinal directions.In various diseases,including coronary artery disease,aortic stenosis,and mitral regurgitation,deficits in longitudinal strain appear to occur earlier than deficits in other measures of strain or in ejection fraction.Consideration of STE measures of left ventricular contraction has the potential to significantly affect clinical management and outcomes of ischemic and valvular heart disease given the ability to separate those with asymptomatic disease who may benefit from earlier interventions than current guidelines may suggest.展开更多
基金This work was supported by the National Key Research and Development Program of China(Nos.2017YFA0403801,2016YFA0401302,2017YFA0206004,2018YFC1200204)the National Major Scientific Instruments and Equipment Development Project of China(No.11627901).
文摘This paper introduces some latest developments regarding the X-ray imaging methodology and applications of the X-ray imaging and biomedical application beamline(BL13W1)at Shanghai Synchrotron Radiation Facility in the past 5 years.The photon energy range of the beamline is 8–72.5 keV.Several sets of X-ray imaging detectors with different pixel sizes(0.19–24 lm)are used to realize X-ray microcomputed tomography(X-ray micro-CT)and X-ray in-line phase-contrast imaging.To satisfy the requirements of user experiments,new X-ray imaging methods and image processing techniques are developed.In vivo dynamic micro-CT experiments with living insects are performed in 0.5 s(sampling rate of 2 Hz,2 tomograms/s)with a monochromatic beam from a wiggler source and in 40 ms(sampling rate of 25 Hz,25 tomograms/s)with a white beam from a bending magnet source.A new X-ray imaging method known as move contrast X-ray imaging is proposed,with which blood flow and moving tissues in raw images can be distinguished according to their moving frequencies in the time domain.Furthermore,X-ray speckle-tracking imaging with twice exposures to eliminate the edge enhancement effect is developed.A high-precision quantification method is realized to measure complex three-dimensional blood vessels obtained via X-ray micro-CT.X-ray imaging methods such as three-dimensional X-ray diffraction microscopy,small-angle X-ray scattering CT,and X-ray fluorescence CT are developed,in which the X-ray micro-CT imaging method is combined with other contrast mechanisms such as diffraction,scattering,and fluorescence contrasts respectively.Moreover,an X-ray nano-CT experiment is performed with a 100 nm spatial resolution.Typical user experimental results from the fields of material science,biomedicine,paleontology,physics,chemistry,and environmental science obtained on the beamline are provided.
文摘The use of speckle-tracking echocardiography(STE)is becoming an increasingly useful tool in the evaluation of myocardial disease.STE software can track the motion of the specular pattern created by the interference of ultrasound with the myofibers of the heart and provide a quantitative means to evaluate subtle changes in ventricular function that often occur before changes in ventricular ejection fraction are observed.STE is most often used to measure the change in shape(strain)of myocardial segments in the circumferential,radial,and longitudinal directions.In various diseases,including coronary artery disease,aortic stenosis,and mitral regurgitation,deficits in longitudinal strain appear to occur earlier than deficits in other measures of strain or in ejection fraction.Consideration of STE measures of left ventricular contraction has the potential to significantly affect clinical management and outcomes of ischemic and valvular heart disease given the ability to separate those with asymptomatic disease who may benefit from earlier interventions than current guidelines may suggest.