The present study aimed to dynamically observe the segmental and global myocardial movements of the left ventricle during coronary artery bypass grafting by transesophageal speckle-tracking echocardiography,and to ass...The present study aimed to dynamically observe the segmental and global myocardial movements of the left ventricle during coronary artery bypass grafting by transesophageal speckle-tracking echocardiography,and to assess the effect of sevoflurane on cardiac function.Sixty-four patients scheduled for the off-pump coronary artery bypass grafting were randomly divided into a sevoflurane-based anesthesia(AS)group and a propofolbased total intravenous anesthesia(AA)group.The AS group demonstrated a higher absolute value of left ventricular global longitudinal strain than that of the AA group at both T1(after harvesting all grafts and before coronary anastomosis)and T_(2)(30 min after completing all coronary anastomoses)(P<0.05).Moreover,strain improvement in the segment with the highest preoperative strain was significantly reduced in the AS group,compared with the AA group at both T1 and T_(2)(P<0.01).The flow of the left internal mammary artery-left anterior descending artery graft was superior,and the postoperative concentration of troponin T decreased rapidly in the AS group,compared with the AA group(P<0.05).Compared with total intravenous anesthesia,sevoflurane resulted in a significantly higher global longitudinal strain,stroke volume,and cardiac output.Sevoflurane also led to an amelioration in the condition of the arterial graft.Furthermore,sevoflurane significantly reduced strain improvement in the segmental myocardium with a high preoperative strain value.The findings need to be replicated in larger studies.展开更多
Objective: To evaluate of the role of transesophageal echocardiography (TEE)in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. Methods:Sixty- two patients (10 to 55 years of age...Objective: To evaluate of the role of transesophageal echocardiography (TEE)in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. Methods:Sixty- two patients (10 to 55 years of age) were selected for percutaneous closure of ASD bytrans-esophageal echocardiography, which was also used to monitor the procedure, to select theappropriate size of the Amplatzer device, to verify its position, and to access the immediateresults of the procedure. During the follow-up, transthoracic echocardiography (TTE) or TEE was usedto evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiacchamber diameters. Results: The mean ASD diameter by TTE ([19. 1 +- 5. 8] mm) was significantlysmaller (P< 0. 001) than the stretched diameter of the ASD (25. 1 +- 6. 4) mm. There are nosignificant differences between the TEE -measured value (23. 5+_6. 2) mm and the stretched diameterof the ASD (P > 0. 05). Due to proper patient selection all procedures were successful. There wasimmediate and complete closure in 61/62 patients, only one patients had trivial residual shunt.Follow- up was performed using TTE or TEE right after operation, 1 d, 1 month, 3 months, 6 monthsand yearly thereafter. Ail, patients remain asymptomatic without any clinical or technical problems.Conclusion: With the aid of TEE, percutaneous closure of ASD can be performed successfully, safely,and effectively.展开更多
AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echo...AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echocardiography(3D TEE) was performed immediately prior to an ablation procedure(paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used(Arctic Front Balloon, Cryo Cath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1(paroxysmal AF), group B(persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up.RESULTS A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonaryvein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely(e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo followup, 68.0% of all patients were free from an arrhythmia recurrence(group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications.CONCLUSION3 D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome.展开更多
The intubation of conventional transesophageal echocardiography(TEE) probes into patients causes serious esophagus irritation, and thus the use of TEE probes in pediatric practice is limited. In this study, we aimed...The intubation of conventional transesophageal echocardiography(TEE) probes into patients causes serious esophagus irritation, and thus the use of TEE probes in pediatric practice is limited. In this study, we aimed at the development of a special probe which could be inserted through the nasopharyngeal cavity into the esophagus to obtain the same high-quality echocardiography images as those obtained by conventional TEE and improve patients' experience. During the examination, the patients felt relaxed for a longer time and cooperated with the sonographers in the process of cardiac catheterization conducted in the surgery room or the intensive care unit(ICU), resulting in improved accuracy of the diagnosis and timely administration of appropriate treatment. Two years ago, Prof. Xin-fang WANG put theories into practice by inserting the probe through the nasal cavity and pharynx into the esophagus of volunteers to successfully detect the heart and great vessels at the retrocardiac space. Later, Prof. Ming-xing XIE performed the transnasal TEE examination in 12 atrial septal defect(ASD) patients and proved the safety and reliability of this method, which could become a new way for clinical diagnosis and treatment.展开更多
BACKGROUND Endocardial fibroelastosis(EFE)is a rare heart disease characterized by thickening of the endocardium caused by massive proliferation of collagenous and elastic tissue,usually leading to impaired cardiac fu...BACKGROUND Endocardial fibroelastosis(EFE)is a rare heart disease characterized by thickening of the endocardium caused by massive proliferation of collagenous and elastic tissue,usually leading to impaired cardiac function.Multimodality cardiovascular imaging for the evaluation of EFE with thrombi is even rarer.CASE SUMMARY We report a rare case of EFE associated with multiple cardiovascular thrombi.Three-dimensional(3D)and contrast echocardiography(CE)were used to assess ventricular thrombi.Anticoagulant therapy was administered to eliminate the thrombi.The peripheral contrast-enhanced thrombi with the highest risk were dissolved with anticoagulant therapy at the time of reexamination,which was consistent with the presumption of fresh loose thrombi.CONCLUSION This new echocardiography technique has a great advantage in the diagnosis and treatment of EFE.On the basis of conventional echocardiography,3D echocardiography is used to display the position,shape,and narrow base of the thrombus.CE does not only help to confirm the diagnosis of thrombus,but also determines its risk.展开更多
One hundred and twenty-four patients with heart disease(75 cases of rheumatic heart disease,26 cases of congenital heart disease,13 cases of aortic disease and 10 cases of other disease)were examined by Omniplane tran...One hundred and twenty-four patients with heart disease(75 cases of rheumatic heart disease,26 cases of congenital heart disease,13 cases of aortic disease and 10 cases of other disease)were examined by Omniplane transesophageal echocardiography(TEE).The result showed that Omniplane TEE transducer can be rotated from 0°to 180°in probe and had the advantages of broader scope,obtaining more information,less stimulation to esophagus and easy to manipulate.It suggests that Omniplane TEE is a efficient technique in clinical diagnosis and can be extensively used in the future.展开更多
One hundred and twenty-five patients with cardiovascular disease were examined by biplanar transesophageal echocardiography (BTEE), including 67 with rheumatic heart disease (7 monitored during operation), 22 with ao...One hundred and twenty-five patients with cardiovascular disease were examined by biplanar transesophageal echocardiography (BTEE), including 67 with rheumatic heart disease (7 monitored during operation), 22 with aortic diseases, 20 with congenital heart diseases. and 16 with other kinds of heart disease. The results showed that BTEE was not influenced by corpulent and pulmonary emphysema and was better than transthoracic echocardiography at imaging the interatrial septum, left atrium and left atrial appendage, thoracic aorta, and mitral artificial valve and at intraoperative monitoring. BTEE was also better than single-plane transesophageal echocardiography,because BTEE could be used to observe the heart and thoracic aorta in transverse and longitudinal planes, thus enlarging the transmission 'window' as well as allowing the entire lesion to be imaged.This study suggests that BTEE will have good prospects in clinical application.展开更多
The clinically applied value of myocardial perfusion and systolic function in patients with coronary artery disease after coronary artery bypass surgery using real-time myocardial contrast echocardiography (RT-MCE) ...The clinically applied value of myocardial perfusion and systolic function in patients with coronary artery disease after coronary artery bypass surgery using real-time myocardial contrast echocardiography (RT-MCE) combined with two-dimensional strain echocardiography was assessed. Twenty patients underwent intravenous RT-MCE by intravenous injections of SonoVue before and after coronary artery bypass surgery. Two-dimensional images were recorded from the left ventricular four-chamber view, two-chamber view and the apical view before, and two weeks and three months after coronary artery bypass surgery, and the peak systolic longitudinal strain was measured. The results showed that myocardial perfusion was significantly increased after coronary artery bypass surgery in about 71.6% segments. In the group that myocardial perfusion was improved, the peak systolic longitu- dinal strain three months after bypass surgery was significantly higher than that before operation [(-15.78±5.91)% vs (-10.45±8.31)%, P〈0.05]. However, the parameters did not change in the group without myocardial perfusion improvement [(-10.33±6.53)% vs (-9.41±6.09)%, P〉0.05]. It was concluded that whether or not the improvement of myocardial perfusion can mirror the recovery trend of regional systolic function, two-dimensional strain echocardiography can observe dynamic change of regional systolic function. The combination of myocardial perfusion with two-dimensional strain echocardiography can more accurately assess the curative effectiveness of coronary artery bypass surgery.展开更多
Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed...Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.展开更多
Methods: Sixteen patients with American Society of Anesthesiologists status (ASA) II-III, age ≤ 70 yr, male or female, preoperatively NYHA II-III and EF ≥ 45%, scheduled for mitral valve replacement (MVR) were studi...Methods: Sixteen patients with American Society of Anesthesiologists status (ASA) II-III, age ≤ 70 yr, male or female, preoperatively NYHA II-III and EF ≥ 45%, scheduled for mitral valve replacement (MVR) were studied. Complete intravenous general anesthesia was used for induction and anesthesia maintenance. After anesthesia induction we put the TEE probe into the esophagus. The cardiac index was determined at three periods following MVR: T1 30 minutes later following cessation of bypass, T2 60 minutes after cessation of bypass, T3 90 minutes after cessation of bypass. Statistical analysis was made with the Bland and Altman method. Results: Ninety-six measurements were compared. The cardiac index values at the level of prosthesis mitral valve (CIMV) ranged from 1.3 to 5.5 L·min-1·m-2 (mean 2.6 ± 0.9). The Values of cardiac index at aortic valve (CIAA) ranged from 2.7 to8.8 L·min-1·m-2 (mean 4.9 ± 1.7). Bias was -2.3 L·min-1·m-2 and limits of agreement -5.6 to 1.0 L·min-1·m-2. Conclusion: During mitral valve replacement, doubtful correlations were observed between values of cardiac index at the mitral valve and the ascending aorta using TEE.展开更多
In order to evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization with intravenous real-time myocardial contrast echocardiography (RT-MCE), intravenous RT-MCE was pe...In order to evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization with intravenous real-time myocardial contrast echocardiography (RT-MCE), intravenous RT-MCE was performed on 20 patients with myocardial infarction before coronary revascularization. Follow-up echocardiography was performed 3 months after coronary revascularization. Segmental wall motion was assessed using 18-segment LV model and classified as normal, hypokinesis, akinesis and dyskinesis. Myocardial perfusion was assessed by visual interpretation and divided into 3 conditions: homogeneous opacification=l; partial or reduced opaciflcation or subendocardial contrast defect=2; constrast defect=3. Myocardial perfusion score index (MPSI) was calculated by dividing the total sum of contrast score by the total number of segments with abnormal wall motion. Twenty patients were classified into 2 groups according to the MPSI: MPSI≤I.5 as good myocardial perfusion, MPSI〉1.5 as poor myocardial perfusion. To assess the left ventricular remodeling, the following comparisons were carried out: (1) Comparisons of left ventricular ejection fraction (LVEF), left ventricular end-systolic volume (LVESV) and left ventricular end-diastolic volume (LVEDV) before and 3 months after revascularization in two groups;(2) Comparisons of LVEF, LVESV and LVEDV pre-revascularization between two groups and comparisons of these 3 months post-revascularization between two groups; (3) Comparisons of the differences in LVEF, LVESV and LVEDV between 3 months post-and pre-revascularization (ALVEF, ALVESV and ALVEDV) between two groups; (4) The linear regression analysis between ALVEF, ALVESV, ALVEDV and MPSI. The results showed that the LVEF obtained 3 months after revascularization in patients with MPSI〉1.5 was obviously lower than that in those with MPSI〈1.5. The LVEDV obtained 3 months post-revascularization in patients with MPSI〉1.5 was obviously larger than that in those with MPSI≤1.5 (P=0.002 and 0.04). The differences in ALVEF and ALVEDV between patients with MPSI〉I.5 and those with MPSI≤1.5 were significant (P=0.002 and 0.001, respectively). Linear regression analysis revealed that MPSI had a negative correlation with ALVEF and a positive correlation with ALVESV, ALVEDV (P=0.004, 0.008, and 0.016, respectively). It was concluded that RT-MCE could accurately evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization.展开更多
Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical e...Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical excision is usually recommended for left-sided tumors and is associated with excellent long-term outcomes. The use of a robot-assisted, minimally invasive surgical approach for management of mitral valve disease is growing, and has been associated with shorter hospital stays and improved early quality of life. Three-dimensional (3D) transesophageal echocardiography (TEE) offers several advantages in the assessment of mitral valve disease and cardiac tumors, including the ability to precisely locate the site of attachment of the mass and the spatial relationships to surrounding structures. These factors are particularly important when planning a surgical approach. We report two cases of mitral valve PFEs which were successfully removed using a robot-assisted, minimally invasive surgical approach with 3D TEE imaging. This approach to treatment of PFEs is an attractive alternative to the traditional approach involving median sternotomy.展开更多
Transesophapeal echocardiography (TEE) can be used as a diagnostic tool during cardiac surgery to direct the surgical procedure and diagnose unanticipated problems. TEE has also been one of the most important means ...Transesophapeal echocardiography (TEE) can be used as a diagnostic tool during cardiac surgery to direct the surgical procedure and diagnose unanticipated problems. TEE has also been one of the most important means of monitoring myocardial ischemia dur- ing coronary artery bypas grafting procedures. The cardiac anesthesiologist can apply intraoperative TEE in evaluating coronary artery anatomy and aorta atherosclerosis, assessing diastolic left ventricular function and preload,measuring intracardiac pressure and cardiac output,detecting ischaemic mitral regurgitation,intracardiac air and pericardial effusion.展开更多
BACKGROUND In recent years,it has been recognized that transesophageal echocardiography(TEE)is of great value in resuscitation of cardiac arrest.However,its safety has rarely been reported.CASE SUMMARY We present a 59...BACKGROUND In recent years,it has been recognized that transesophageal echocardiography(TEE)is of great value in resuscitation of cardiac arrest.However,its safety has rarely been reported.CASE SUMMARY We present a 59-year-old male patient scheduled to undergo cardiac surgery for rheumatic heart disease.Upper gastrointestinal bleeding from a Mallory-Weiss tear appeared following cardiopulmonary resuscitation,TEE,and percutaneous cardiopulmonary bypass resuscitation when he suffered from aesthesia-related cardiac arrest.Gastrointestinal injury was diagnosed promptly and treated effectively.However,the exact etiology of gastrointestinal injury was unclear;the interaction of closed-chest cardiac massage and the application of TEE may be involved as a most possible mechanism of injury.CONCLUSION Serious complications should be considered when TEE is used in patients with special pathophysiological conditions.展开更多
One hundred and twenty-four patients with heart disease were examined by omniplane TEE in order to systematically research every views of omniplane TEE, and further explore anatomy and image feature of each view. The ...One hundred and twenty-four patients with heart disease were examined by omniplane TEE in order to systematically research every views of omniplane TEE, and further explore anatomy and image feature of each view. The result showed that omniplane TEE transducer can be rotated in probe from 0°to 180°.obtain many views at various angles behind the heart and fully demonstrate the structure and pathology of the heart and great vessels. It was useful for clinical diagnosis because of getting more information about the heart and great vessels. As omniplane TEE probe was little rotated in esophagus, it lessened esophagus stimulation. Meanwhile, it was suitable for three-dimensional reconstruction of left ventriculum.展开更多
Background For many years in ischemic heart disease, ventricles rather than atria received attention so not much is known about left atrial function in left ventricular ischemia. Objective Our study aimed to evaluate ...Background For many years in ischemic heart disease, ventricles rather than atria received attention so not much is known about left atrial function in left ventricular ischemia. Objective Our study aimed to evaluate left atrial appendage (LAA) function by means of biplane transesophageal echocardiography in patients ten days after acute coronary syndromes (ACS). Methods The study was performed on 16 adult patients (65.9±9.9 years old) in whom transesophageal echocardiography was done 10 days after ACS. The following left atrial appendage (LAA) planimetric parameters were analyzed: LAA transversal dimension, LAA longitudinal dimension,LAA maximal area, and LAA minimal area. LAA ejection fraction was calculated and analyzed. The following LAA Doppler parameters were analyzed: the peak LAA emptying and the peak LAA filling velocities. The control group consisted of 14 patients (43±14.6 years old) without cardiovascular diseases. Results Both LAA longitudinal dimension and LAA transversal dimension were significantly higher in patients with ACS than in control patients. The same was observed for LAA maximal area. Also LAA ejection fraction was higher in patients with ACS . LAA minimal area did not differ in the patients in either group. LAA peak emptying flow (LAAE) and LAA peak filling flow (LAAF) were significantly higher in patients of the study group than of the control group. Conclusion Our study shows that two weeks after acute coronary syndrome LAA as a reservoir as well as a pump works at a higher level than it does in the control group. (J Geriatr Cardiol 2005; 2(4):198-201)展开更多
The myocardial viability after myocardial infarction was evaluated by intravenous myocardial contrast echocardiography. Intravenous real-time myocardial contrast echocardiography was performed on 18 patients with myoc...The myocardial viability after myocardial infarction was evaluated by intravenous myocardial contrast echocardiography. Intravenous real-time myocardial contrast echocardiography was performed on 18 patients with myocardial infarction before coronary revascularization. Follow-up echocardiography was performed 3 months after coronary revascularization. Segmental wall motion was assessed using 18-segment LV model and classified as normal, hypokinesis, akinesis and dyskinesis. Viable myocardium was defined by evident improvement of segmental wall motion 3 months after coronary revascularization. Myocardial perfusion was assessed by visual interpretation and divided into 3 conditions: homogeneous opacification; partial or reduced opaciflcation or subendocardial contrast defect; contrast defect. The former two conditions were used as the standard to define the viable myocardium. The results showed that 109 abnormal wall motion segments were detected among 18 patients with myocardial infarction, including 47 segments of hypokinesis, 56 segments of akinesis and 6 segments of dyskinesis. The wall motion of 2 segments with hypokinesis before coronary revascularization which showed homogeneous opacification, 14 of 24 segments with hypokinese and 20 of 24 segments with akinese before coronary revascularization which showed partial or reduced opaciflcation or subendocardial contrast defect was improved 3 months after coronary revascularization. In our study, the sensitivity and specificity of evaluation of myocardial viability after myocardial infarction by intravenous real-time myocardial contrast echocardiography were 94.7% and 78.9%, respectively. It was concluded that intravenous real-time myocardial contrast echocardiography could accurately evaluate myocardial viability after myocardial infarction.展开更多
To evaluate the feasibility of real-time myocardial contrast echocardiography (RTMCE) by quantitative analysis of myocardial perfusion in rabbits, transthoracic RTMCE was performed in 10 healthy rabbits by using con...To evaluate the feasibility of real-time myocardial contrast echocardiography (RTMCE) by quantitative analysis of myocardial perfusion in rabbits, transthoracic RTMCE was performed in 10 healthy rabbits by using continuous infusion of SonoVue into the auricular vein. The short axis view at the papillary muscle level was obtained. The duration of the time that the contrast took to appear in right heart, left heart and myocardium was recorded. The regional myocardial signal intensity (SI) versus re-filling time plots were fitted to an exponential function: y(t) =A(1–e–β(t–t0)) + C, where y is SI at any given time, A is the SI plateau that reflects myocardial blood volume, and β is the slope of the refilling curve that reflects myocardial microbubble velocity. The A, β and A×β values at different infusion rate of SonoVue were analyzed and the A, β and A×β values in each segment in the short axis view at the papillary muscle level were compared. All the animal experiments were successful and high-quality im-ages were obtained. The best intravenous infusion rate for SonoVue was 30 mL/h. The contrast appeared in right heart, left heart and myocardium at 7.5±2.2 s, 9.1±2.4 s and 12.2±1.6 s respectively. After 16.6±2.3s, myocardial opacification reached a steady state. The mean A, β and A×β value in the short axis view at the papillary muscle level were 9.8±3.0 dB, 1.4±0.5 s-1 and 13.5±3.6 dB×s-1 respectively. A, β and A×β values showed no significant differences among 6 segments. It was suggested that RTMCE was feasible for quantitative analysis of myocardial perfusion in rabbits. It provides a non-invasive method to evaluate the myocardial perfusion in rabbit disease models.展开更多
This paper reports the use of three-dimensional (3-D) transesophageal echocardiography(TEE) in the diagnosis of atrial septal defect. The results displayed that the interatrial septum had integrity in normal persons. ...This paper reports the use of three-dimensional (3-D) transesophageal echocardiography(TEE) in the diagnosis of atrial septal defect. The results displayed that the interatrial septum had integrity in normal persons. The size,shape and position of atrial septal defects could be showed clearly and the type of the defects could be identified. The reconstructed imaging of interatrial septum on 3-D TEE was clear and stereoscopic. The technique is helpful in defining spatial location and extent of atrial septal defects.展开更多
Background In an effort to avoid x-ray and contrast agents for patients of atrial fibrillation(AF)with chronic kidney disease,we developed a method for transcatheter closure of left atrial appendage(LAA)under the guid...Background In an effort to avoid x-ray and contrast agents for patients of atrial fibrillation(AF)with chronic kidney disease,we developed a method for transcatheter closure of left atrial appendage(LAA)under the guidance of transesophageal echocardiography(TEE)without fluoroscopy.展开更多
基金supported by Jiangsu Province Hospital(the First Affiliated Hospital of Nanjing Medical University)Clinical Capacity Enhancement and was awarded to the first author,Chanjuan Gong(Grant No.JSPH-MC-2022-4).
文摘The present study aimed to dynamically observe the segmental and global myocardial movements of the left ventricle during coronary artery bypass grafting by transesophageal speckle-tracking echocardiography,and to assess the effect of sevoflurane on cardiac function.Sixty-four patients scheduled for the off-pump coronary artery bypass grafting were randomly divided into a sevoflurane-based anesthesia(AS)group and a propofolbased total intravenous anesthesia(AA)group.The AS group demonstrated a higher absolute value of left ventricular global longitudinal strain than that of the AA group at both T1(after harvesting all grafts and before coronary anastomosis)and T_(2)(30 min after completing all coronary anastomoses)(P<0.05).Moreover,strain improvement in the segment with the highest preoperative strain was significantly reduced in the AS group,compared with the AA group at both T1 and T_(2)(P<0.01).The flow of the left internal mammary artery-left anterior descending artery graft was superior,and the postoperative concentration of troponin T decreased rapidly in the AS group,compared with the AA group(P<0.05).Compared with total intravenous anesthesia,sevoflurane resulted in a significantly higher global longitudinal strain,stroke volume,and cardiac output.Sevoflurane also led to an amelioration in the condition of the arterial graft.Furthermore,sevoflurane significantly reduced strain improvement in the segmental myocardium with a high preoperative strain value.The findings need to be replicated in larger studies.
文摘Objective: To evaluate of the role of transesophageal echocardiography (TEE)in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. Methods:Sixty- two patients (10 to 55 years of age) were selected for percutaneous closure of ASD bytrans-esophageal echocardiography, which was also used to monitor the procedure, to select theappropriate size of the Amplatzer device, to verify its position, and to access the immediateresults of the procedure. During the follow-up, transthoracic echocardiography (TTE) or TEE was usedto evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiacchamber diameters. Results: The mean ASD diameter by TTE ([19. 1 +- 5. 8] mm) was significantlysmaller (P< 0. 001) than the stretched diameter of the ASD (25. 1 +- 6. 4) mm. There are nosignificant differences between the TEE -measured value (23. 5+_6. 2) mm and the stretched diameterof the ASD (P > 0. 05). Due to proper patient selection all procedures were successful. There wasimmediate and complete closure in 61/62 patients, only one patients had trivial residual shunt.Follow- up was performed using TTE or TEE right after operation, 1 d, 1 month, 3 months, 6 monthsand yearly thereafter. Ail, patients remain asymptomatic without any clinical or technical problems.Conclusion: With the aid of TEE, percutaneous closure of ASD can be performed successfully, safely,and effectively.
文摘AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echocardiography(3D TEE) was performed immediately prior to an ablation procedure(paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used(Arctic Front Balloon, Cryo Cath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1(paroxysmal AF), group B(persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up.RESULTS A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonaryvein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely(e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo followup, 68.0% of all patients were free from an arrhythmia recurrence(group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications.CONCLUSION3 D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome.
基金supported by the Natural Science Foundation of Hubei Province(No.2016CFB229)
文摘The intubation of conventional transesophageal echocardiography(TEE) probes into patients causes serious esophagus irritation, and thus the use of TEE probes in pediatric practice is limited. In this study, we aimed at the development of a special probe which could be inserted through the nasopharyngeal cavity into the esophagus to obtain the same high-quality echocardiography images as those obtained by conventional TEE and improve patients' experience. During the examination, the patients felt relaxed for a longer time and cooperated with the sonographers in the process of cardiac catheterization conducted in the surgery room or the intensive care unit(ICU), resulting in improved accuracy of the diagnosis and timely administration of appropriate treatment. Two years ago, Prof. Xin-fang WANG put theories into practice by inserting the probe through the nasal cavity and pharynx into the esophagus of volunteers to successfully detect the heart and great vessels at the retrocardiac space. Later, Prof. Ming-xing XIE performed the transnasal TEE examination in 12 atrial septal defect(ASD) patients and proved the safety and reliability of this method, which could become a new way for clinical diagnosis and treatment.
基金Supported by National Natural Science Foundation of China,No.81571686.
文摘BACKGROUND Endocardial fibroelastosis(EFE)is a rare heart disease characterized by thickening of the endocardium caused by massive proliferation of collagenous and elastic tissue,usually leading to impaired cardiac function.Multimodality cardiovascular imaging for the evaluation of EFE with thrombi is even rarer.CASE SUMMARY We report a rare case of EFE associated with multiple cardiovascular thrombi.Three-dimensional(3D)and contrast echocardiography(CE)were used to assess ventricular thrombi.Anticoagulant therapy was administered to eliminate the thrombi.The peripheral contrast-enhanced thrombi with the highest risk were dissolved with anticoagulant therapy at the time of reexamination,which was consistent with the presumption of fresh loose thrombi.CONCLUSION This new echocardiography technique has a great advantage in the diagnosis and treatment of EFE.On the basis of conventional echocardiography,3D echocardiography is used to display the position,shape,and narrow base of the thrombus.CE does not only help to confirm the diagnosis of thrombus,but also determines its risk.
文摘One hundred and twenty-four patients with heart disease(75 cases of rheumatic heart disease,26 cases of congenital heart disease,13 cases of aortic disease and 10 cases of other disease)were examined by Omniplane transesophageal echocardiography(TEE).The result showed that Omniplane TEE transducer can be rotated from 0°to 180°in probe and had the advantages of broader scope,obtaining more information,less stimulation to esophagus and easy to manipulate.It suggests that Omniplane TEE is a efficient technique in clinical diagnosis and can be extensively used in the future.
文摘One hundred and twenty-five patients with cardiovascular disease were examined by biplanar transesophageal echocardiography (BTEE), including 67 with rheumatic heart disease (7 monitored during operation), 22 with aortic diseases, 20 with congenital heart diseases. and 16 with other kinds of heart disease. The results showed that BTEE was not influenced by corpulent and pulmonary emphysema and was better than transthoracic echocardiography at imaging the interatrial septum, left atrium and left atrial appendage, thoracic aorta, and mitral artificial valve and at intraoperative monitoring. BTEE was also better than single-plane transesophageal echocardiography,because BTEE could be used to observe the heart and thoracic aorta in transverse and longitudinal planes, thus enlarging the transmission 'window' as well as allowing the entire lesion to be imaged.This study suggests that BTEE will have good prospects in clinical application.
文摘The clinically applied value of myocardial perfusion and systolic function in patients with coronary artery disease after coronary artery bypass surgery using real-time myocardial contrast echocardiography (RT-MCE) combined with two-dimensional strain echocardiography was assessed. Twenty patients underwent intravenous RT-MCE by intravenous injections of SonoVue before and after coronary artery bypass surgery. Two-dimensional images were recorded from the left ventricular four-chamber view, two-chamber view and the apical view before, and two weeks and three months after coronary artery bypass surgery, and the peak systolic longitudinal strain was measured. The results showed that myocardial perfusion was significantly increased after coronary artery bypass surgery in about 71.6% segments. In the group that myocardial perfusion was improved, the peak systolic longitu- dinal strain three months after bypass surgery was significantly higher than that before operation [(-15.78±5.91)% vs (-10.45±8.31)%, P〈0.05]. However, the parameters did not change in the group without myocardial perfusion improvement [(-10.33±6.53)% vs (-9.41±6.09)%, P〉0.05]. It was concluded that whether or not the improvement of myocardial perfusion can mirror the recovery trend of regional systolic function, two-dimensional strain echocardiography can observe dynamic change of regional systolic function. The combination of myocardial perfusion with two-dimensional strain echocardiography can more accurately assess the curative effectiveness of coronary artery bypass surgery.
文摘Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.
文摘Methods: Sixteen patients with American Society of Anesthesiologists status (ASA) II-III, age ≤ 70 yr, male or female, preoperatively NYHA II-III and EF ≥ 45%, scheduled for mitral valve replacement (MVR) were studied. Complete intravenous general anesthesia was used for induction and anesthesia maintenance. After anesthesia induction we put the TEE probe into the esophagus. The cardiac index was determined at three periods following MVR: T1 30 minutes later following cessation of bypass, T2 60 minutes after cessation of bypass, T3 90 minutes after cessation of bypass. Statistical analysis was made with the Bland and Altman method. Results: Ninety-six measurements were compared. The cardiac index values at the level of prosthesis mitral valve (CIMV) ranged from 1.3 to 5.5 L·min-1·m-2 (mean 2.6 ± 0.9). The Values of cardiac index at aortic valve (CIAA) ranged from 2.7 to8.8 L·min-1·m-2 (mean 4.9 ± 1.7). Bias was -2.3 L·min-1·m-2 and limits of agreement -5.6 to 1.0 L·min-1·m-2. Conclusion: During mitral valve replacement, doubtful correlations were observed between values of cardiac index at the mitral valve and the ascending aorta using TEE.
文摘In order to evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization with intravenous real-time myocardial contrast echocardiography (RT-MCE), intravenous RT-MCE was performed on 20 patients with myocardial infarction before coronary revascularization. Follow-up echocardiography was performed 3 months after coronary revascularization. Segmental wall motion was assessed using 18-segment LV model and classified as normal, hypokinesis, akinesis and dyskinesis. Myocardial perfusion was assessed by visual interpretation and divided into 3 conditions: homogeneous opacification=l; partial or reduced opaciflcation or subendocardial contrast defect=2; constrast defect=3. Myocardial perfusion score index (MPSI) was calculated by dividing the total sum of contrast score by the total number of segments with abnormal wall motion. Twenty patients were classified into 2 groups according to the MPSI: MPSI≤I.5 as good myocardial perfusion, MPSI〉1.5 as poor myocardial perfusion. To assess the left ventricular remodeling, the following comparisons were carried out: (1) Comparisons of left ventricular ejection fraction (LVEF), left ventricular end-systolic volume (LVESV) and left ventricular end-diastolic volume (LVEDV) before and 3 months after revascularization in two groups;(2) Comparisons of LVEF, LVESV and LVEDV pre-revascularization between two groups and comparisons of these 3 months post-revascularization between two groups; (3) Comparisons of the differences in LVEF, LVESV and LVEDV between 3 months post-and pre-revascularization (ALVEF, ALVESV and ALVEDV) between two groups; (4) The linear regression analysis between ALVEF, ALVESV, ALVEDV and MPSI. The results showed that the LVEF obtained 3 months after revascularization in patients with MPSI〉1.5 was obviously lower than that in those with MPSI〈1.5. The LVEDV obtained 3 months post-revascularization in patients with MPSI〉1.5 was obviously larger than that in those with MPSI≤1.5 (P=0.002 and 0.04). The differences in ALVEF and ALVEDV between patients with MPSI〉I.5 and those with MPSI≤1.5 were significant (P=0.002 and 0.001, respectively). Linear regression analysis revealed that MPSI had a negative correlation with ALVEF and a positive correlation with ALVESV, ALVEDV (P=0.004, 0.008, and 0.016, respectively). It was concluded that RT-MCE could accurately evaluate the left ventricular remodeling in patients with myocardial infarction after revascularization.
文摘Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical excision is usually recommended for left-sided tumors and is associated with excellent long-term outcomes. The use of a robot-assisted, minimally invasive surgical approach for management of mitral valve disease is growing, and has been associated with shorter hospital stays and improved early quality of life. Three-dimensional (3D) transesophageal echocardiography (TEE) offers several advantages in the assessment of mitral valve disease and cardiac tumors, including the ability to precisely locate the site of attachment of the mass and the spatial relationships to surrounding structures. These factors are particularly important when planning a surgical approach. We report two cases of mitral valve PFEs which were successfully removed using a robot-assisted, minimally invasive surgical approach with 3D TEE imaging. This approach to treatment of PFEs is an attractive alternative to the traditional approach involving median sternotomy.
文摘Transesophapeal echocardiography (TEE) can be used as a diagnostic tool during cardiac surgery to direct the surgical procedure and diagnose unanticipated problems. TEE has also been one of the most important means of monitoring myocardial ischemia dur- ing coronary artery bypas grafting procedures. The cardiac anesthesiologist can apply intraoperative TEE in evaluating coronary artery anatomy and aorta atherosclerosis, assessing diastolic left ventricular function and preload,measuring intracardiac pressure and cardiac output,detecting ischaemic mitral regurgitation,intracardiac air and pericardial effusion.
文摘BACKGROUND In recent years,it has been recognized that transesophageal echocardiography(TEE)is of great value in resuscitation of cardiac arrest.However,its safety has rarely been reported.CASE SUMMARY We present a 59-year-old male patient scheduled to undergo cardiac surgery for rheumatic heart disease.Upper gastrointestinal bleeding from a Mallory-Weiss tear appeared following cardiopulmonary resuscitation,TEE,and percutaneous cardiopulmonary bypass resuscitation when he suffered from aesthesia-related cardiac arrest.Gastrointestinal injury was diagnosed promptly and treated effectively.However,the exact etiology of gastrointestinal injury was unclear;the interaction of closed-chest cardiac massage and the application of TEE may be involved as a most possible mechanism of injury.CONCLUSION Serious complications should be considered when TEE is used in patients with special pathophysiological conditions.
文摘One hundred and twenty-four patients with heart disease were examined by omniplane TEE in order to systematically research every views of omniplane TEE, and further explore anatomy and image feature of each view. The result showed that omniplane TEE transducer can be rotated in probe from 0°to 180°.obtain many views at various angles behind the heart and fully demonstrate the structure and pathology of the heart and great vessels. It was useful for clinical diagnosis because of getting more information about the heart and great vessels. As omniplane TEE probe was little rotated in esophagus, it lessened esophagus stimulation. Meanwhile, it was suitable for three-dimensional reconstruction of left ventriculum.
文摘Background For many years in ischemic heart disease, ventricles rather than atria received attention so not much is known about left atrial function in left ventricular ischemia. Objective Our study aimed to evaluate left atrial appendage (LAA) function by means of biplane transesophageal echocardiography in patients ten days after acute coronary syndromes (ACS). Methods The study was performed on 16 adult patients (65.9±9.9 years old) in whom transesophageal echocardiography was done 10 days after ACS. The following left atrial appendage (LAA) planimetric parameters were analyzed: LAA transversal dimension, LAA longitudinal dimension,LAA maximal area, and LAA minimal area. LAA ejection fraction was calculated and analyzed. The following LAA Doppler parameters were analyzed: the peak LAA emptying and the peak LAA filling velocities. The control group consisted of 14 patients (43±14.6 years old) without cardiovascular diseases. Results Both LAA longitudinal dimension and LAA transversal dimension were significantly higher in patients with ACS than in control patients. The same was observed for LAA maximal area. Also LAA ejection fraction was higher in patients with ACS . LAA minimal area did not differ in the patients in either group. LAA peak emptying flow (LAAE) and LAA peak filling flow (LAAF) were significantly higher in patients of the study group than of the control group. Conclusion Our study shows that two weeks after acute coronary syndrome LAA as a reservoir as well as a pump works at a higher level than it does in the control group. (J Geriatr Cardiol 2005; 2(4):198-201)
文摘The myocardial viability after myocardial infarction was evaluated by intravenous myocardial contrast echocardiography. Intravenous real-time myocardial contrast echocardiography was performed on 18 patients with myocardial infarction before coronary revascularization. Follow-up echocardiography was performed 3 months after coronary revascularization. Segmental wall motion was assessed using 18-segment LV model and classified as normal, hypokinesis, akinesis and dyskinesis. Viable myocardium was defined by evident improvement of segmental wall motion 3 months after coronary revascularization. Myocardial perfusion was assessed by visual interpretation and divided into 3 conditions: homogeneous opacification; partial or reduced opaciflcation or subendocardial contrast defect; contrast defect. The former two conditions were used as the standard to define the viable myocardium. The results showed that 109 abnormal wall motion segments were detected among 18 patients with myocardial infarction, including 47 segments of hypokinesis, 56 segments of akinesis and 6 segments of dyskinesis. The wall motion of 2 segments with hypokinesis before coronary revascularization which showed homogeneous opacification, 14 of 24 segments with hypokinese and 20 of 24 segments with akinese before coronary revascularization which showed partial or reduced opaciflcation or subendocardial contrast defect was improved 3 months after coronary revascularization. In our study, the sensitivity and specificity of evaluation of myocardial viability after myocardial infarction by intravenous real-time myocardial contrast echocardiography were 94.7% and 78.9%, respectively. It was concluded that intravenous real-time myocardial contrast echocardiography could accurately evaluate myocardial viability after myocardial infarction.
文摘To evaluate the feasibility of real-time myocardial contrast echocardiography (RTMCE) by quantitative analysis of myocardial perfusion in rabbits, transthoracic RTMCE was performed in 10 healthy rabbits by using continuous infusion of SonoVue into the auricular vein. The short axis view at the papillary muscle level was obtained. The duration of the time that the contrast took to appear in right heart, left heart and myocardium was recorded. The regional myocardial signal intensity (SI) versus re-filling time plots were fitted to an exponential function: y(t) =A(1–e–β(t–t0)) + C, where y is SI at any given time, A is the SI plateau that reflects myocardial blood volume, and β is the slope of the refilling curve that reflects myocardial microbubble velocity. The A, β and A×β values at different infusion rate of SonoVue were analyzed and the A, β and A×β values in each segment in the short axis view at the papillary muscle level were compared. All the animal experiments were successful and high-quality im-ages were obtained. The best intravenous infusion rate for SonoVue was 30 mL/h. The contrast appeared in right heart, left heart and myocardium at 7.5±2.2 s, 9.1±2.4 s and 12.2±1.6 s respectively. After 16.6±2.3s, myocardial opacification reached a steady state. The mean A, β and A×β value in the short axis view at the papillary muscle level were 9.8±3.0 dB, 1.4±0.5 s-1 and 13.5±3.6 dB×s-1 respectively. A, β and A×β values showed no significant differences among 6 segments. It was suggested that RTMCE was feasible for quantitative analysis of myocardial perfusion in rabbits. It provides a non-invasive method to evaluate the myocardial perfusion in rabbit disease models.
文摘This paper reports the use of three-dimensional (3-D) transesophageal echocardiography(TEE) in the diagnosis of atrial septal defect. The results displayed that the interatrial septum had integrity in normal persons. The size,shape and position of atrial septal defects could be showed clearly and the type of the defects could be identified. The reconstructed imaging of interatrial septum on 3-D TEE was clear and stereoscopic. The technique is helpful in defining spatial location and extent of atrial septal defects.
文摘Background In an effort to avoid x-ray and contrast agents for patients of atrial fibrillation(AF)with chronic kidney disease,we developed a method for transcatheter closure of left atrial appendage(LAA)under the guidance of transesophageal echocardiography(TEE)without fluoroscopy.