As an important product of Moderate Resolution Imaging Spectroradiometer(MODIS), MOD17A2 provides dramatic improvements in our ability to accurately and continuously monitor global terrestrial primary production, whic...As an important product of Moderate Resolution Imaging Spectroradiometer(MODIS), MOD17A2 provides dramatic improvements in our ability to accurately and continuously monitor global terrestrial primary production, which is also significant in effort to advance scientific research and eco-environmental management. Over the past decades, forests have moderated climate change by sequestrating about one-quarter of the carbon emitted by human activities through fossil fuels burning and land use/land cover change. Thus, the carbon uptake by forests reduces the rate at which carbon accumulates in the atmosphere. However, the sensitivity of near real-time MODIS gross primary productivity(GPP) product is directly constrained by uncertainties in the modeling process, especially in complicated forest ecosystems. Although there have been plenty of studies to verify MODIS GPP with ground-based measurements using the eddy covariance(EC) technique, few have comprehensively validated the performance of MODIS estimates(Collection 5) across diverse forest types. Therefore, the present study examined the degree of correspondence between MODIS-derived GPP and EC-measured GPP at seasonal and interannual time scales for the main forest ecosystems, including evergreen broadleaf forest(EBF), evergreen needleleaf forest(ENF), deciduous broadleaf forest(DBF), and mixed forest(MF) relying on 16 flux towers with a total of 68 site-year datasets. Overall, site-specific evaluation of multi-year mean annual GPP estimates indicates that the current MOD17A2 product works highly effectively for MF and DBF, moderately effectively for ENF, and ineffectively for EBF. Except for tropical forest, MODIS estimates could capture the broad trends of GPP at 8-day time scale for all other sites surveyed. On the annual time scale, the best performance was observed in MF, followed by ENF, DBF, and EBF. Trend analyses also revealed the poor performance of MODIS GPP product in EBF and DBF. Thus, improvements in the sensitivity of MOD17A2 to forest productivity require continued efforts.展开更多
For flux measurement, the eddy covariance technique supplies a possibility to directly measure the exchange between vegetation and atmosphere; and there are two kinds of eddy covariance systems, open-path and close-pa...For flux measurement, the eddy covariance technique supplies a possibility to directly measure the exchange between vegetation and atmosphere; and there are two kinds of eddy covariance systems, open-path and close-path systems. For the system error, it may result in difference of flux measurements by two systems. Therefore, it is necessary to compare the measured results from them. ChinaFLUX covers of eight sites applied the micrometeorological method, in which Changbai Mountains (CBS) and Qianyanzhou (QYZ) carried out open-path eddy covariance (OPEC) and close-path eddy covariance (CPEC) measurements synchronously. In this paper the data sets of CBS and QYZ were employed. The delay time of close-path analyzer to the open-path analyzer was calculated; the spectra and cospectra of time-series data of OPEC and CPEC were analyzed; the open-path flux measurement was used as a standard comparison, the close-path flux measurement results were evaluated. The results show that, at two sites the delay time of CO2 density for close-path analyzer was about 7.0-8.0 s, H2O density about 8.0-9.0 s; the spectrum from the open-path, close-path and 3D sonic anemometer was consistent with the expected -2/3 slope (log-log plot), and the cospectra showed the expected slope of -4/3 in the internal subrange; the CO? flux measured by the close-path sensor was about 84% of that of open-path measurement at QYZ, about 80% at CBS, and the latent heat flux was balanced for two systems at QYZ, 86% at CBS. From the flux difference between open-path and close-path analyzers, it could be inferred that the attenuation of turbulent fluctuations in flow through tube of CPEC affected H2O flux more significantly than CO2 flux. The gap between two systems was bigger at CBS than at QYZ; the diurnal variation in CO2 flux of two measurement systems was very consistent.展开更多
基金Under the auspices of National Natural Science Foundation of China(No.41401221,41271500,41201496)Opening Fund of Key Laboratory of Poyang Lake Wetland and Watershed Research(Jiangxi Normal University),Ministry of Education,China(No.PK2014002)
文摘As an important product of Moderate Resolution Imaging Spectroradiometer(MODIS), MOD17A2 provides dramatic improvements in our ability to accurately and continuously monitor global terrestrial primary production, which is also significant in effort to advance scientific research and eco-environmental management. Over the past decades, forests have moderated climate change by sequestrating about one-quarter of the carbon emitted by human activities through fossil fuels burning and land use/land cover change. Thus, the carbon uptake by forests reduces the rate at which carbon accumulates in the atmosphere. However, the sensitivity of near real-time MODIS gross primary productivity(GPP) product is directly constrained by uncertainties in the modeling process, especially in complicated forest ecosystems. Although there have been plenty of studies to verify MODIS GPP with ground-based measurements using the eddy covariance(EC) technique, few have comprehensively validated the performance of MODIS estimates(Collection 5) across diverse forest types. Therefore, the present study examined the degree of correspondence between MODIS-derived GPP and EC-measured GPP at seasonal and interannual time scales for the main forest ecosystems, including evergreen broadleaf forest(EBF), evergreen needleleaf forest(ENF), deciduous broadleaf forest(DBF), and mixed forest(MF) relying on 16 flux towers with a total of 68 site-year datasets. Overall, site-specific evaluation of multi-year mean annual GPP estimates indicates that the current MOD17A2 product works highly effectively for MF and DBF, moderately effectively for ENF, and ineffectively for EBF. Except for tropical forest, MODIS estimates could capture the broad trends of GPP at 8-day time scale for all other sites surveyed. On the annual time scale, the best performance was observed in MF, followed by ENF, DBF, and EBF. Trend analyses also revealed the poor performance of MODIS GPP product in EBF and DBF. Thus, improvements in the sensitivity of MOD17A2 to forest productivity require continued efforts.
文摘For flux measurement, the eddy covariance technique supplies a possibility to directly measure the exchange between vegetation and atmosphere; and there are two kinds of eddy covariance systems, open-path and close-path systems. For the system error, it may result in difference of flux measurements by two systems. Therefore, it is necessary to compare the measured results from them. ChinaFLUX covers of eight sites applied the micrometeorological method, in which Changbai Mountains (CBS) and Qianyanzhou (QYZ) carried out open-path eddy covariance (OPEC) and close-path eddy covariance (CPEC) measurements synchronously. In this paper the data sets of CBS and QYZ were employed. The delay time of close-path analyzer to the open-path analyzer was calculated; the spectra and cospectra of time-series data of OPEC and CPEC were analyzed; the open-path flux measurement was used as a standard comparison, the close-path flux measurement results were evaluated. The results show that, at two sites the delay time of CO2 density for close-path analyzer was about 7.0-8.0 s, H2O density about 8.0-9.0 s; the spectrum from the open-path, close-path and 3D sonic anemometer was consistent with the expected -2/3 slope (log-log plot), and the cospectra showed the expected slope of -4/3 in the internal subrange; the CO? flux measured by the close-path sensor was about 84% of that of open-path measurement at QYZ, about 80% at CBS, and the latent heat flux was balanced for two systems at QYZ, 86% at CBS. From the flux difference between open-path and close-path analyzers, it could be inferred that the attenuation of turbulent fluctuations in flow through tube of CPEC affected H2O flux more significantly than CO2 flux. The gap between two systems was bigger at CBS than at QYZ; the diurnal variation in CO2 flux of two measurement systems was very consistent.