期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Effect of Low Dose Radiation on Intracellular Calcium and Protein Kinase C in Lymphocytes 被引量:3
1
作者 LIU SHU-ZHENG SU XU +2 位作者 HAN ZHEN-BO ZHANG YING-CHUN AND QI JIN (The MPH Radiobiology Research Unit, Norman Bethune University of Medical Sciences, 6 Xinmin Street, Changchun 130021, China) 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 1994年第3期284-291,共8页
It is first reported in the present paper that whole-body irradiation (WBI) with low dose X-rays could increase intracellular calcium ions ([Ca2+]i) and stimulate protein kinase C (PKC) activity of mouse lymphocytes. ... It is first reported in the present paper that whole-body irradiation (WBI) with low dose X-rays could increase intracellular calcium ions ([Ca2+]i) and stimulate protein kinase C (PKC) activity of mouse lymphocytes. Following WBI of male Kunming micc With 75 mGy X-rays at a dose rate of 12.5 mGy/min the mobilization of [Ca2+]i with Con A in CD4+ and CD8+ Cells in the thymus and spleen was potentiated and the amplitude of [Ca2+], mobilization in thymocytes in response to anti-CD3 monoclonal antibody increased with time from 4 to 24 h following low dose radiation. The PKC activity in the homogenate of spleen was markedly stimulated 12 h after WBl with 75 mGy, reaching its peak value at 24-48 h and coming down to lower than normal on day 7. However, the PKC activity in the separated T lymphocytes reached its peak value at 12 h and that in the B lymphocytes reached its peak value on day 4, both coming down to below control on day 7. The implications of this facilitation of signal transduction in T lymphocytes in the mechanism of immunoenhancement after low dose radiation were discussed 展开更多
关键词 ZHANG CA Effect of Low dose radiation on Intracellular Calcium and Protein Kinase C in Lymphocytes
下载PDF
Effect of Cycloheximide on the Adaptive Response Induced by Low Dose Radiation 被引量:4
2
作者 CAI Lu AND LIu SHUZHENGDepartment of Radiation Biology, Institute of Radiation Medicine, Norman Bethune University of Medical Sciences, Changchun 130021, China Corresponding author 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 1992年第1期46-52,共7页
Human lymphocytes pre-exposed to 10 mGy or 50 mGy of X-rays become less sensitive to subsequent large dose irradiation, exhibited lower rate of chromosome aberration than expected. This adaptive response could be inhi... Human lymphocytes pre-exposed to 10 mGy or 50 mGy of X-rays become less sensitive to subsequent large dose irradiation, exhibited lower rate of chromosome aberration than expected. This adaptive response could be inhibited by cycloheximide, a protein synthesis inhibitor for successive 2 h period ranging from 0.5h before to 4h after the low dose exposure, indicating that the adaptive response was directly related with the protein synthesis. 展开更多
关键词 In Effect of Cycloheximide on the Adaptive Response Induced by Low dose radiation
下载PDF
Total Ionizing Dose Radiation Effects in the P-Type Polycrystalline Silicon Thin Film Transistors
3
作者 刘远 刘凯 +4 位作者 陈荣盛 刘玉荣 恩云飞 李斌 方文啸 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第1期133-136,共4页
The total ionizing dose radiation effects in the polycrystalline silicon thin film transistors are studied. Transfer characteristics, high-frequency capacitance-voltage curves and low-frequency noises (LFN) are measur... The total ionizing dose radiation effects in the polycrystalline silicon thin film transistors are studied. Transfer characteristics, high-frequency capacitance-voltage curves and low-frequency noises (LFN) are measured before and after radiation. The experimental results show that threshold voltage and hole-field-effect mobility decrease, while sub-threshold swing and low-frequency noise increase with the increase of the total dose. The contributions of radiation induced interface states and oxide trapped charges to the shift of threshold voltage are also estimated. Furthermore, spatial distributions of oxide trapped charges before and after radiation are extracted based on the LFN measurements. 展开更多
关键词 Total Ionizing dose radiation Effects in the P-Type Polycrystalline Silicon Thin Film Transistors SIO
下载PDF
Total dose radiation effects on SOI NMOS transistors with different layouts 被引量:1
4
作者 田浩 张正选 +3 位作者 贺威 俞文杰 王茹 陈明 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第8期645-648,共4页
Partially-depleted Silicon-On-Insulator Negative Channel Metal Oxide Semiconductor (SOI NMOS) transistors with different layouts are fabricated on radiation hard Separation by IMplanted OXygen (SIMOX) substrate an... Partially-depleted Silicon-On-Insulator Negative Channel Metal Oxide Semiconductor (SOI NMOS) transistors with different layouts are fabricated on radiation hard Separation by IMplanted OXygen (SIMOX) substrate and tested using 10 keV X-ray radiation sources. The radiation performance is characterized by transistor threshold voltage shift and transistor leakage currents as a function of the total dose up to 2.0×10^6 rad(Si). The results show that the total dose radiation effects on NMOS devices are very sensitive to their layout structures. 展开更多
关键词 SIMOX SOI total dose radiation effect MOS transistors
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部