Coal washing plants are usually fed from various sources. Coals include different combinations which should be considered for increasing the plant proficiency. Thus different methods have been used to enrich various c...Coal washing plants are usually fed from various sources. Coals include different combinations which should be considered for increasing the plant proficiency. Thus different methods have been used to enrich various coal types. In this study, Alborz-Sharghi coal washing plant was investigated which is fed from five coalmines. The optimum recovery was achieved for all coal types individually through experimental design. The controllable operation parameters in the experiments were collector dosage,frother dosage, solid percent content and particle size. The other parameters such as impeller speed,pH, conditioning time and flotation time were kept constant for all experiments. The optimum combination of coals was also specified. The results show that the optimum recovery for coal blends is 91.2%which shows much improvement relative to the plant conditions.展开更多
Objectives To explore the optimized program-control mode of a dual-chamber pacemaker combined withβ-blocker to treat congenital long QT syndrome(LQTS). Methods 12 LQTS patients in our hospital that still have symptom...Objectives To explore the optimized program-control mode of a dual-chamber pacemaker combined withβ-blocker to treat congenital long QT syndrome(LQTS). Methods 12 LQTS patients in our hospital that still have symptoms despite use of regular drug therapies or that can not endure the therapies were implanted with DDD cardiac pacemaker.The QT/QTc intervals of those patients were measured at different pacing rates respectively.Their cardiac pacemakers were all programmed to selectively turn on and turn off some related functions at the pacing rate of 80 beats/min.The dosage ofβ-blockers was adjusted according to the patients’ PR intervals and blood pressures.The MACE and the cardiac function of the patients were recorded after operation.Results The measured QT / QTc interval decreased with the pacing rate increasing.The pacing rate of 80 beats/min can make QT/QTc interval basically normal. The MACE of the patients were statistically declined(P = 0.003) and no negative effect on cardiac function was found during the follow-up.Conclusions The optimized program-control mode of a dual-chamber pacemaker combined withβ-blocker to treat congenital LQTS are:to pace at the rate of 80 beats/min and program to turn off lag,sleep,automatic preventing PMT and automatic threshold-capture feature and turn on the PVC,rate adaptation and atrioventricular node priority function.展开更多
Undergraduate student’s satisfaction is fundamental to creating and implementing successful higher education.The present study sought to identify the factors and analyses impact on satisfaction and service quality.Th...Undergraduate student’s satisfaction is fundamental to creating and implementing successful higher education.The present study sought to identify the factors and analyses impact on satisfaction and service quality.The research was carried out in Chinese higher education institution,with a sample of 1660 students.Based on the higher education satisfaction questionnaire,the“optimal path”model of problem improvement was constructed by applying the“structural equation model”,satisfaction and importance matrix diagram,improvement effect size and other tools.Eight major areas of three-dimensional improvement of“satisfaction,importance,and improvement effect”were formed.Identify the issues that students have urgent demands,high importance,and strong improvement effects.Scientifically analyze the main attention focus of each subgroup of students.Concentrate superior resources and strengths,formulate targeted measures and make key breakthroughs based on“light”,“heavy”,“slow”,“urgent”and“classified”.Provide suggestions for improving student’s satisfaction and promoting the development of high-quality connotative and characteristic development in higher education.展开更多
In summary,the interval uncertainty is introduced to the acoustic metamaterial with Helmholtz resonators.And then,new descriptions(the conservative approximation,the unsafe approximation and the approximation precisio...In summary,the interval uncertainty is introduced to the acoustic metamaterial with Helmholtz resonators.And then,new descriptions(the conservative approximation,the unsafe approximation and the approximation precision)on uncertainties of physical properties of this interval acoustic metamaterial are defined.Lastly,an optimization model for this interval acoustic metamaterial is proposed.The organization of this paper is listed as follows.The acoustic transmission line method(ATLM)for an acoustic metamaterial with Helmholtz resonators is described in Section 2.In Section3,uncertain analysis of the interval acoustic metamaterial is presented.In Section 4,optimization model of the interval acoustic metamaterial is proposed.The discussion on optimization results is shown in Section 5.In section 6,some conclusions are given.展开更多
The multi-objective differential evolution(MODE)algorithm is an effective method to solve multi-objective optimization problems.However,in the absence of any information of evolution progress,the optimization strategy...The multi-objective differential evolution(MODE)algorithm is an effective method to solve multi-objective optimization problems.However,in the absence of any information of evolution progress,the optimization strategy of the MODE algorithm still appears as an open problem.In this paper,a dynamic multi-objective differential evolution algorithm,based on the information of evolution progress(DMODE-IEP),is developed to improve the optimization performance.The main contributions of DMODE-IEP are as follows.First,the information of evolution progress,using the fitness values,is proposed to describe the evolution progress of MODE.Second,the dynamic adjustment mechanisms of evolution parameter values,mutation strategies and selection parameter value based on the information of evolution progress,are designed to balance the global exploration ability and the local exploitation ability.Third,the convergence of DMODE-IEP is proved using the probability theory.Finally,the testing results on the standard multi-objective optimization problem and the wastewater treatment process verify that the optimization effect of DMODE-IEP algorithm is superior to the other compared state-of-the-art multi-objective optimization algorithms,including the quality of the solutions,and the optimization speed of the algorithm.展开更多
文摘Coal washing plants are usually fed from various sources. Coals include different combinations which should be considered for increasing the plant proficiency. Thus different methods have been used to enrich various coal types. In this study, Alborz-Sharghi coal washing plant was investigated which is fed from five coalmines. The optimum recovery was achieved for all coal types individually through experimental design. The controllable operation parameters in the experiments were collector dosage,frother dosage, solid percent content and particle size. The other parameters such as impeller speed,pH, conditioning time and flotation time were kept constant for all experiments. The optimum combination of coals was also specified. The results show that the optimum recovery for coal blends is 91.2%which shows much improvement relative to the plant conditions.
文摘Objectives To explore the optimized program-control mode of a dual-chamber pacemaker combined withβ-blocker to treat congenital long QT syndrome(LQTS). Methods 12 LQTS patients in our hospital that still have symptoms despite use of regular drug therapies or that can not endure the therapies were implanted with DDD cardiac pacemaker.The QT/QTc intervals of those patients were measured at different pacing rates respectively.Their cardiac pacemakers were all programmed to selectively turn on and turn off some related functions at the pacing rate of 80 beats/min.The dosage ofβ-blockers was adjusted according to the patients’ PR intervals and blood pressures.The MACE and the cardiac function of the patients were recorded after operation.Results The measured QT / QTc interval decreased with the pacing rate increasing.The pacing rate of 80 beats/min can make QT/QTc interval basically normal. The MACE of the patients were statistically declined(P = 0.003) and no negative effect on cardiac function was found during the follow-up.Conclusions The optimized program-control mode of a dual-chamber pacemaker combined withβ-blocker to treat congenital LQTS are:to pace at the rate of 80 beats/min and program to turn off lag,sleep,automatic preventing PMT and automatic threshold-capture feature and turn on the PVC,rate adaptation and atrioventricular node priority function.
基金supported by the Chongqing Education Science Planning funds,and the project is 2021-GX-114.
文摘Undergraduate student’s satisfaction is fundamental to creating and implementing successful higher education.The present study sought to identify the factors and analyses impact on satisfaction and service quality.The research was carried out in Chinese higher education institution,with a sample of 1660 students.Based on the higher education satisfaction questionnaire,the“optimal path”model of problem improvement was constructed by applying the“structural equation model”,satisfaction and importance matrix diagram,improvement effect size and other tools.Eight major areas of three-dimensional improvement of“satisfaction,importance,and improvement effect”were formed.Identify the issues that students have urgent demands,high importance,and strong improvement effects.Scientifically analyze the main attention focus of each subgroup of students.Concentrate superior resources and strengths,formulate targeted measures and make key breakthroughs based on“light”,“heavy”,“slow”,“urgent”and“classified”.Provide suggestions for improving student’s satisfaction and promoting the development of high-quality connotative and characteristic development in higher education.
基金supported by National Natural Science Foundation of China(Grant Nos.11402083&11572121)Independent Research Project of State Key Laboratory of Advanced Design and Manufacturing for Vehicle Body in Hunan University(Grant No.51375002)Fundamental Research Funds for the Central Universities,Collaborative Innovation Center of Intelligent New Energy Vehicle,and the Hunan Collaborative Innovation Center of Green Automobile
文摘In summary,the interval uncertainty is introduced to the acoustic metamaterial with Helmholtz resonators.And then,new descriptions(the conservative approximation,the unsafe approximation and the approximation precision)on uncertainties of physical properties of this interval acoustic metamaterial are defined.Lastly,an optimization model for this interval acoustic metamaterial is proposed.The organization of this paper is listed as follows.The acoustic transmission line method(ATLM)for an acoustic metamaterial with Helmholtz resonators is described in Section 2.In Section3,uncertain analysis of the interval acoustic metamaterial is presented.In Section 4,optimization model of the interval acoustic metamaterial is proposed.The discussion on optimization results is shown in Section 5.In section 6,some conclusions are given.
基金This work was supported by the National Natural Science Foundation of China(Grant Nos.61903010 and 61890930-5)Beijing Outstanding Young Scientist Program(Grant No.BJJWZYJH01201910005020)Beijing Natural Science Foundation(Grant No.KZ202110005009).
文摘The multi-objective differential evolution(MODE)algorithm is an effective method to solve multi-objective optimization problems.However,in the absence of any information of evolution progress,the optimization strategy of the MODE algorithm still appears as an open problem.In this paper,a dynamic multi-objective differential evolution algorithm,based on the information of evolution progress(DMODE-IEP),is developed to improve the optimization performance.The main contributions of DMODE-IEP are as follows.First,the information of evolution progress,using the fitness values,is proposed to describe the evolution progress of MODE.Second,the dynamic adjustment mechanisms of evolution parameter values,mutation strategies and selection parameter value based on the information of evolution progress,are designed to balance the global exploration ability and the local exploitation ability.Third,the convergence of DMODE-IEP is proved using the probability theory.Finally,the testing results on the standard multi-objective optimization problem and the wastewater treatment process verify that the optimization effect of DMODE-IEP algorithm is superior to the other compared state-of-the-art multi-objective optimization algorithms,including the quality of the solutions,and the optimization speed of the algorithm.