This research investigates the behavior of a 2×2 pile group under two-directional lateral loads in addition to the vertical load.Through three-dimensional numerical modeling based on Flac 3D software,the study ex...This research investigates the behavior of a 2×2 pile group under two-directional lateral loads in addition to the vertical load.Through three-dimensional numerical modeling based on Flac 3D software,the study examines the total bearing capacity and efficiency coefficient of the pile group,considering factors such as the angle of lateral load,relative pile spacing,and relative stiffness of the pile-soil system.The findings highlight the significance of these factors in understanding and predicting the response of pile groups to changing lateral load directions.The results reveal that increasing the angle of the lateral load from 0°to 45°enhances both the maximum total lateral load and the efficiency coefficient of the pile group.When the relative stiffness of the pile-soil system significantly increases,soil stiffening occurs and reducing the relative spacing of the piles from 7 to 3 times the diameter of the piles diminishes the influence of the pile group.Consequently,the response of the pile group to lateral loads becomes more linear,with only a slight alteration in the maximum total lateral load and the efficiency coefficient when the lateral load is angled from 0°to 45°.Conversely,increasing the relative distance between the piles,specifically from 3 to 7 times the diameter of the piles,amplifies the influence of the pile group.Both the maximum total lateral load and the efficiency coefficient of the pile group exhibit an observed increase.These provide insights for designing pile groups and optimizing their performance under lateral loading conditions.展开更多
Reducing the cost of offshore platform construction is an urgent issue for marginal oilfield development.The offshore oil well structure includes a riser and a surface casing.The riser,surface casing and oil well ceme...Reducing the cost of offshore platform construction is an urgent issue for marginal oilfield development.The offshore oil well structure includes a riser and a surface casing.The riser,surface casing and oil well cement can be considered special variable cross-section piles.Replacing or partially replacing the steel pipe pile foundation with a variable cross-section pile to provide the required bearing capacity for an offshore oil platform can reduce the cost of foundation construction and improve the economic efficiency of production.In this paper,the finite element analysis method is used to investigate the variable cross-section bearing mode of composite piles composed of a riser and a surface casing in saturated clay under a vertical load.The calculation formula of the bearing capacity at the variable section is derived based on the theory of spherical cavity expansion,the influencing factors of the bearing capacity coefficient N_(c) are revealed,and the calculation method of N_(c) is proposed.By comparing the calculation results with the results of the centrifuge test,the accuracy and applicability of the calculation method are verified.The results show that the riser composite pile has a rigid core in the soil under the variable cross-section,which increases the bearing capacity at the variable cross-section.展开更多
Different techniques have been proposed to increase the bearing capacity of open-ended piles.Welding helices to the shaft and tapering the pile shaft could be used simultaneously to enhance the static and dynamic beha...Different techniques have been proposed to increase the bearing capacity of open-ended piles.Welding helices to the shaft and tapering the pile shaft could be used simultaneously to enhance the static and dynamic behaviors of these piles.This paper subjects the bearing capacity,stiffness,frictional behavior,and material efficiency of the tapered helical piles to scrutiny.Tapered helical piles are introduced herein as an alternative option to improve the material efficiency of hollow piles.Based on the Taguchi method,a series of experiments was designed and conducted.The axial responses of tapered helical piles are also investigated using finite element analyses.The results derived from loadedisplacement curves and strain gages are used to characterize the axial compression responses of tapered helical piles.The effects of tapered angle,helices diameter and helices distance are examined using dimensionless parameters,and the degree of contribution of these factors is calculated on each of the enumerated variables individually.Experimental results show that the shaft friction resistance of tapered helical piles increases continuously with the pile head settlement.Furthermore,the effect of tapered wall on the shaft friction resistance is more tangible at low stress levels.The results showed that the relative material efficiency factor of the optimum pile could be 2.5 times that of unoptimized pile with a similar quantity of material.展开更多
云南红河特大桥建水侧采用浅埋重力式锚碇基础,锚碇后趾区和前趾区分别坐落在中风化板岩和强风化板岩上。该工程在前趾区域采用非等长刚性桩复合地基方案解决土岩组合地基、偏心受荷等因素引起的不均匀沉降和水平变位问题。为保证方案...云南红河特大桥建水侧采用浅埋重力式锚碇基础,锚碇后趾区和前趾区分别坐落在中风化板岩和强风化板岩上。该工程在前趾区域采用非等长刚性桩复合地基方案解决土岩组合地基、偏心受荷等因素引起的不均匀沉降和水平变位问题。为保证方案可靠性,项目在中风化和强风化板岩区域分别进行了3组直剪试验、3组载荷试验,针对刚性桩开展了2组单桩载荷试验。试验得到了中风化、强风化板岩的地基承载力分别不小于1200 kPa、800 k Pa,与基础的摩阻系数分别为0.60、0.55;单桩承载力特征值不小于3500 kN。展开更多
文摘This research investigates the behavior of a 2×2 pile group under two-directional lateral loads in addition to the vertical load.Through three-dimensional numerical modeling based on Flac 3D software,the study examines the total bearing capacity and efficiency coefficient of the pile group,considering factors such as the angle of lateral load,relative pile spacing,and relative stiffness of the pile-soil system.The findings highlight the significance of these factors in understanding and predicting the response of pile groups to changing lateral load directions.The results reveal that increasing the angle of the lateral load from 0°to 45°enhances both the maximum total lateral load and the efficiency coefficient of the pile group.When the relative stiffness of the pile-soil system significantly increases,soil stiffening occurs and reducing the relative spacing of the piles from 7 to 3 times the diameter of the piles diminishes the influence of the pile group.Consequently,the response of the pile group to lateral loads becomes more linear,with only a slight alteration in the maximum total lateral load and the efficiency coefficient when the lateral load is angled from 0°to 45°.Conversely,increasing the relative distance between the piles,specifically from 3 to 7 times the diameter of the piles,amplifies the influence of the pile group.Both the maximum total lateral load and the efficiency coefficient of the pile group exhibit an observed increase.These provide insights for designing pile groups and optimizing their performance under lateral loading conditions.
基金This research was financially supported by the National Science Fund for Distinguished Young Scholars(Grant No.51825904)the National Science and Technology Major Project from the Ministry of Science and Technology(MOST)of China(Grant No.2016ZX05058004-005).
文摘Reducing the cost of offshore platform construction is an urgent issue for marginal oilfield development.The offshore oil well structure includes a riser and a surface casing.The riser,surface casing and oil well cement can be considered special variable cross-section piles.Replacing or partially replacing the steel pipe pile foundation with a variable cross-section pile to provide the required bearing capacity for an offshore oil platform can reduce the cost of foundation construction and improve the economic efficiency of production.In this paper,the finite element analysis method is used to investigate the variable cross-section bearing mode of composite piles composed of a riser and a surface casing in saturated clay under a vertical load.The calculation formula of the bearing capacity at the variable section is derived based on the theory of spherical cavity expansion,the influencing factors of the bearing capacity coefficient N_(c) are revealed,and the calculation method of N_(c) is proposed.By comparing the calculation results with the results of the centrifuge test,the accuracy and applicability of the calculation method are verified.The results show that the riser composite pile has a rigid core in the soil under the variable cross-section,which increases the bearing capacity at the variable cross-section.
文摘Different techniques have been proposed to increase the bearing capacity of open-ended piles.Welding helices to the shaft and tapering the pile shaft could be used simultaneously to enhance the static and dynamic behaviors of these piles.This paper subjects the bearing capacity,stiffness,frictional behavior,and material efficiency of the tapered helical piles to scrutiny.Tapered helical piles are introduced herein as an alternative option to improve the material efficiency of hollow piles.Based on the Taguchi method,a series of experiments was designed and conducted.The axial responses of tapered helical piles are also investigated using finite element analyses.The results derived from loadedisplacement curves and strain gages are used to characterize the axial compression responses of tapered helical piles.The effects of tapered angle,helices diameter and helices distance are examined using dimensionless parameters,and the degree of contribution of these factors is calculated on each of the enumerated variables individually.Experimental results show that the shaft friction resistance of tapered helical piles increases continuously with the pile head settlement.Furthermore,the effect of tapered wall on the shaft friction resistance is more tangible at low stress levels.The results showed that the relative material efficiency factor of the optimum pile could be 2.5 times that of unoptimized pile with a similar quantity of material.
文摘云南红河特大桥建水侧采用浅埋重力式锚碇基础,锚碇后趾区和前趾区分别坐落在中风化板岩和强风化板岩上。该工程在前趾区域采用非等长刚性桩复合地基方案解决土岩组合地基、偏心受荷等因素引起的不均匀沉降和水平变位问题。为保证方案可靠性,项目在中风化和强风化板岩区域分别进行了3组直剪试验、3组载荷试验,针对刚性桩开展了2组单桩载荷试验。试验得到了中风化、强风化板岩的地基承载力分别不小于1200 kPa、800 k Pa,与基础的摩阻系数分别为0.60、0.55;单桩承载力特征值不小于3500 kN。