This paper presents an efficient hybrid control approach through combining the idea of proportional- integral-derivative (PID) controller and linear quadratic regulator (LQR) control algorithm. The proposed LQR-PI...This paper presents an efficient hybrid control approach through combining the idea of proportional- integral-derivative (PID) controller and linear quadratic regulator (LQR) control algorithm. The proposed LQR-PID controller, while having the advantage of the classical PID controller, is easy to implement in seismic-excited structures. Using an optimization procedure based on a cuckoo search (CS) algorithm, the LQR-PID controller is designed for a seismic- excited structure equipped with an active tuned mass damper (ATMD). Considering four earthquakes, the performance of the proposed LQR-PID controller is evaluated. Then, the results are compared with those given by a LQR controller. The simulation results indicate that the LQR-PID performs better than the LQR controller in reduction of seismic responses of the structure in the terms of displacement and acceleration of stories of the structure.展开更多
In the seismic safety evaluation (SSE) for key projects, the probability-consistent spectrum (PCS), usually obtained from probabilistic seismic hazard analysis (PSHA), is not consistent with the design response spectr...In the seismic safety evaluation (SSE) for key projects, the probability-consistent spectrum (PCS), usually obtained from probabilistic seismic hazard analysis (PSHA), is not consistent with the design response spectrum given by Code for Seismic Design of Buildings (GB50011-2001). Sometimes, there may be a remarkable difference be-tween them. If the PCS is lower than the corresponding code design response spectrum (CDS), the seismic fortifi-cation criterion for the key projects would be lower than that for the general industry and civil buildings. In the paper, the relation between PCS and CDS is discussed by using the ideal simple potential seismic source. The re-sults show that in the most areas influenced mainly by the potential sources of the epicentral earthquakes and the regional earthquakes, PCS is generally lower than CDS in the long periods. We point out that the long-period re-sponse spectra of the code should be further studied and combined with the probability method of seismic zoning as much as possible. Because of the uncertainties in SSE, it should be prudent to use the long-period response spectra given by SSE for key projects when they are lower than CDS.展开更多
文摘This paper presents an efficient hybrid control approach through combining the idea of proportional- integral-derivative (PID) controller and linear quadratic regulator (LQR) control algorithm. The proposed LQR-PID controller, while having the advantage of the classical PID controller, is easy to implement in seismic-excited structures. Using an optimization procedure based on a cuckoo search (CS) algorithm, the LQR-PID controller is designed for a seismic- excited structure equipped with an active tuned mass damper (ATMD). Considering four earthquakes, the performance of the proposed LQR-PID controller is evaluated. Then, the results are compared with those given by a LQR controller. The simulation results indicate that the LQR-PID performs better than the LQR controller in reduction of seismic responses of the structure in the terms of displacement and acceleration of stories of the structure.
基金Shanghai Science & Technology Development Foundation (022512065) and Shanghai Construction Technology Development Foundation (A0206101).
文摘In the seismic safety evaluation (SSE) for key projects, the probability-consistent spectrum (PCS), usually obtained from probabilistic seismic hazard analysis (PSHA), is not consistent with the design response spectrum given by Code for Seismic Design of Buildings (GB50011-2001). Sometimes, there may be a remarkable difference be-tween them. If the PCS is lower than the corresponding code design response spectrum (CDS), the seismic fortifi-cation criterion for the key projects would be lower than that for the general industry and civil buildings. In the paper, the relation between PCS and CDS is discussed by using the ideal simple potential seismic source. The re-sults show that in the most areas influenced mainly by the potential sources of the epicentral earthquakes and the regional earthquakes, PCS is generally lower than CDS in the long periods. We point out that the long-period re-sponse spectra of the code should be further studied and combined with the probability method of seismic zoning as much as possible. Because of the uncertainties in SSE, it should be prudent to use the long-period response spectra given by SSE for key projects when they are lower than CDS.