Chlorofluorocarbons(CFCs) or hydrochlorofluorocarbons(HCFCs) are as main refrigerants used in traditional refrigeration systems driven by electricity from burning fossil fuels, which is regarded as one of the major re...Chlorofluorocarbons(CFCs) or hydrochlorofluorocarbons(HCFCs) are as main refrigerants used in traditional refrigeration systems driven by electricity from burning fossil fuels, which is regarded as one of the major reasons for ozone depletion (man-made refrigerants emission) and global warming (CO 2 emission). So people pay more and more attention to natural refrigerants and energy saving technologies. An innovative system combining CO 2 transcritical cycle with ejector cycle is proposed in this paper. The CO 2 compression sub-cycle is powered by electricity with the characteristics of relatively high temperature in the gas cooler (defined as an intercooler by the proposed system). In order to recover the waste heat, an ejector sub-cycle operating with the natural refrigerants (NH 3, H 2O) is employed. The two sub-cycles are connected by an intercooler. This combined cycle joins the advantages of the two cycles together and eliminates the disadvantages. The influences of the evaporation temperature in CO 2 compression sub-cycle, the evaporation temperature in the ejector sub-cycle, the temperature in the intercooler and the condensation temperature in the proposed system performance are discussed theoretically in this study. In addition, some unique features of the system are presented.展开更多
Ejector can utilize high pressure energy from liquid mechanism,it can be used in heat pump system coupled with economized vapor injection(EVI)scroll compressor.When running under low temperature conditions,the perform...Ejector can utilize high pressure energy from liquid mechanism,it can be used in heat pump system coupled with economized vapor injection(EVI)scroll compressor.When running under low temperature conditions,the performance of the EVI system with ejector can be improved further.In this paper,the design method of the heat pump system with ejector is presented,and the process for designing the heat pump with ejector(EVIe)was summarized.One prototype heat pump was designed under the condition of the evaporation temperature of -20oC,and an experimental setup was established to test the prototype.The measured results demonstrated that the heating EER(energy efficiency ratio)of the EVIe could reach about 4%higher than that of the system without the ejector when the heating capacity remained nearly constant.The design method is helpful to development of a heat pump system coupled with scroll compressor and ejector.展开更多
In this paper,an ejector enhanced high-temperature heat pump with dual-pressure condensation and evaporation is proposed to improve the system performance.Theoretical analyses of the system operation characteristics a...In this paper,an ejector enhanced high-temperature heat pump with dual-pressure condensation and evaporation is proposed to improve the system performance.Theoretical analyses of the system operation characteristics are conducted using energetic and exergetic methods.The performance comparisons among the basic cycle,parallel compression cycle,and ejector enhanced cycle are conducted with six different refrigerants,including R245fa,R600a,R1234ze(Z),R1336mzz(Z),R1224yd(Z),and R1233zd(E).The results demonstrate that environmentally-friendly refrigerant R1234ze(Z)would be a promising alternative refrigerant.Compared with the basic cycle and parallel compression cycle at selected operation conditions,29.5%and 12.6%improvements in COP,and 16.7%and 11.1%higher system exergy efficiency are achieved in the ejector enhanced cycle on average.The volumetric heating capacity of the ejector enhanced cycle is increased by 15.7%–21.7%.The ejector enhanced cycle outperforms the other two cycles in high-temperature heat pump applications at the large temperature lift and temperature rise in the heat sink.The assessment offers an option to improve the energy utilization efficiency of the high-temperature heat pumps.展开更多
文摘Chlorofluorocarbons(CFCs) or hydrochlorofluorocarbons(HCFCs) are as main refrigerants used in traditional refrigeration systems driven by electricity from burning fossil fuels, which is regarded as one of the major reasons for ozone depletion (man-made refrigerants emission) and global warming (CO 2 emission). So people pay more and more attention to natural refrigerants and energy saving technologies. An innovative system combining CO 2 transcritical cycle with ejector cycle is proposed in this paper. The CO 2 compression sub-cycle is powered by electricity with the characteristics of relatively high temperature in the gas cooler (defined as an intercooler by the proposed system). In order to recover the waste heat, an ejector sub-cycle operating with the natural refrigerants (NH 3, H 2O) is employed. The two sub-cycles are connected by an intercooler. This combined cycle joins the advantages of the two cycles together and eliminates the disadvantages. The influences of the evaporation temperature in CO 2 compression sub-cycle, the evaporation temperature in the ejector sub-cycle, the temperature in the intercooler and the condensation temperature in the proposed system performance are discussed theoretically in this study. In addition, some unique features of the system are presented.
基金supported by the National Natural Science Foundation of China(Grant No.50776001)
文摘Ejector can utilize high pressure energy from liquid mechanism,it can be used in heat pump system coupled with economized vapor injection(EVI)scroll compressor.When running under low temperature conditions,the performance of the EVI system with ejector can be improved further.In this paper,the design method of the heat pump system with ejector is presented,and the process for designing the heat pump with ejector(EVIe)was summarized.One prototype heat pump was designed under the condition of the evaporation temperature of -20oC,and an experimental setup was established to test the prototype.The measured results demonstrated that the heating EER(energy efficiency ratio)of the EVIe could reach about 4%higher than that of the system without the ejector when the heating capacity remained nearly constant.The design method is helpful to development of a heat pump system coupled with scroll compressor and ejector.
基金financially supported by the National Natural Science Foundation of China(NSFC)under grant No.51806160the China Postdoctoral Science Foundation(CPSF)under grant No.2018M640982。
文摘In this paper,an ejector enhanced high-temperature heat pump with dual-pressure condensation and evaporation is proposed to improve the system performance.Theoretical analyses of the system operation characteristics are conducted using energetic and exergetic methods.The performance comparisons among the basic cycle,parallel compression cycle,and ejector enhanced cycle are conducted with six different refrigerants,including R245fa,R600a,R1234ze(Z),R1336mzz(Z),R1224yd(Z),and R1233zd(E).The results demonstrate that environmentally-friendly refrigerant R1234ze(Z)would be a promising alternative refrigerant.Compared with the basic cycle and parallel compression cycle at selected operation conditions,29.5%and 12.6%improvements in COP,and 16.7%and 11.1%higher system exergy efficiency are achieved in the ejector enhanced cycle on average.The volumetric heating capacity of the ejector enhanced cycle is increased by 15.7%–21.7%.The ejector enhanced cycle outperforms the other two cycles in high-temperature heat pump applications at the large temperature lift and temperature rise in the heat sink.The assessment offers an option to improve the energy utilization efficiency of the high-temperature heat pumps.