To solve the severe problem of wind power curtailment in the winter heating period caused by "power determined by heat" operation constraint of cogeneration units, this paper analyzes thermoelectric load, wind power...To solve the severe problem of wind power curtailment in the winter heating period caused by "power determined by heat" operation constraint of cogeneration units, this paper analyzes thermoelectric load, wind power output distribution and fluctuation characteristics at different time scales, and finally proposes a two level coordinated control strategy based on electric heat storage and pumped storage. The optimization target of the first level coordinated control is the lowest operation cost and the largest wind power utilization rate. Based on prediction of thermoelectric load and wind power, the operation economy of the system and wind power accommodation level are improved with the cooperation of electric heat storage and pumped storage in regulation capacity. The second level coordinated control stabilizes wind power real time fluctuations by cooperating electric heat storage and pumped storage in control speed. The example results of actual wind farms in Jiuquan, Gansu verifies the feasibility and effectiveness of the proposed coordinated control strategy.展开更多
In order to ensure the safety of fluid flow in deep-water submarine pipelines,a safe and energy-saving built-in skin effect electric heat tracing technology was adopted as the thermal management strategy.The magnetic ...In order to ensure the safety of fluid flow in deep-water submarine pipelines,a safe and energy-saving built-in skin effect electric heat tracing technology was adopted as the thermal management strategy.The magnetic field distribution of built-in skin effect heating system is analyzed based on the mechanism of built-in skin effect heating system,so as to obtain the equivalent circuit model of built-in skin effect electric heating system.Meanwhile,heating power is introduced as an intermediate variable to establish the relationship between power supply frequency and built-in skin effect heating temperature.Aiming at the skin effect electric heating system,an Active Disturbance Rejection Control(ADRC)method is proposed macroscopically based on Hammerstein model.Firstly,the parameters of Hammerstein model are identified and optimized using the auxiliary model and standard particle swarm optimization algorithm.Then,the ADRC controller of linear link is designed,and the required heating temperature is used to solve the intermediate variable heating power.Finally,inversion calculation is applied in the nonlinear link to solve the required power frequency,so as to achieve the purpose of efficient heating and verify the feasibility and effectiveness of control strategy through simulation.展开更多
Coupling between electricity systems and heating systems are becoming stronger,leading to more flexible and more complex interactions between these systems.The operation of integrated energy systems is greatly affecte...Coupling between electricity systems and heating systems are becoming stronger,leading to more flexible and more complex interactions between these systems.The operation of integrated energy systems is greatly affected,especially when security is concerned.Steady-state analysis methods have been widely studied in recent research,which is far from enough when the slow thermal dynamics of heating networks are introduced.Therefore,an integrated quasi-dynamic model of integrated electricity and heating systems is developed.The model combines a heating network dynamic thermal model and the sequential steady-state models of electricity networks,coupling components,and heating network hydraulics.Based on this model,a simulation method is proposed and quasi-dynamic interactions between electricity systems and heating systems are quantified with the highlights of transport delay.Then the quasi-dynamic interactions were applied using security control to relieve congestion in electricity systems.Results show that both the transport delay and control strategies have significant influences on the quasi-dynamic interactions.展开更多
Due to the poor heating performance and operating safety in low ambient temperature,traditional Air Source Heat Pump(ASHP)for Electric Vehicles(EVs)has many limits in cold region,which can be solved by the ASHP with r...Due to the poor heating performance and operating safety in low ambient temperature,traditional Air Source Heat Pump(ASHP)for Electric Vehicles(EVs)has many limits in cold region,which can be solved by the ASHP with refrigerant injection.During the start-up stage of EV in winter,the inlet air temperature of the in-car condenser is the same as the ambient temperature.At this situation,the performance and control strategy of the heat pump require special attention.In the present study,a series of experiments were carried out on the heating performance of the Refrigerant Injection Heat Pump(RIHP)system in start-up stage of EV,at the ambient temperature from–20℃ to–5℃.The effects of compressor speed and injected refrigerant state on the heating performance of the system were discussed in depth.According to the results,the control strategies during start-up stage have been discussed in the end of the article.The study provides a practical control strategy for the RIHP system during the start-up stage of electric vehicles,helping to efficiently operate electric vehicles in cold regions.展开更多
increasing penetration of renewable energy sources with a wide range of operating conditions causing power system uncertainties, conventional controllers are incapable of providing proper performance to keep the syste...increasing penetration of renewable energy sources with a wide range of operating conditions causing power system uncertainties, conventional controllers are incapable of providing proper performance to keep the system stable. However, controllable or dispatchable loads such as electric vehicles (EVs) and heat pumps (HPs) can be utilized for supplementary frequency control. This paper shows the ability of plug-in hybrid EVs, HPs, and batteries (BTs) to contribute in the frequency control of an isolated power system. Moreover, we propose a new online intelligent approach by using a coefficient diagram method (CDM) to enhance the system performance and robustness against uncertainties. The performance of the proposed intelligent CDM control has been compared with the proportional-integral (PI) controller and the superiority of the proposed scheme has been verified in Matiab/Simulink programs.展开更多
基金National Natural Science Foundation of China(No.61663019)
文摘To solve the severe problem of wind power curtailment in the winter heating period caused by "power determined by heat" operation constraint of cogeneration units, this paper analyzes thermoelectric load, wind power output distribution and fluctuation characteristics at different time scales, and finally proposes a two level coordinated control strategy based on electric heat storage and pumped storage. The optimization target of the first level coordinated control is the lowest operation cost and the largest wind power utilization rate. Based on prediction of thermoelectric load and wind power, the operation economy of the system and wind power accommodation level are improved with the cooperation of electric heat storage and pumped storage in regulation capacity. The second level coordinated control stabilizes wind power real time fluctuations by cooperating electric heat storage and pumped storage in control speed. The example results of actual wind farms in Jiuquan, Gansu verifies the feasibility and effectiveness of the proposed coordinated control strategy.
文摘In order to ensure the safety of fluid flow in deep-water submarine pipelines,a safe and energy-saving built-in skin effect electric heat tracing technology was adopted as the thermal management strategy.The magnetic field distribution of built-in skin effect heating system is analyzed based on the mechanism of built-in skin effect heating system,so as to obtain the equivalent circuit model of built-in skin effect electric heating system.Meanwhile,heating power is introduced as an intermediate variable to establish the relationship between power supply frequency and built-in skin effect heating temperature.Aiming at the skin effect electric heating system,an Active Disturbance Rejection Control(ADRC)method is proposed macroscopically based on Hammerstein model.Firstly,the parameters of Hammerstein model are identified and optimized using the auxiliary model and standard particle swarm optimization algorithm.Then,the ADRC controller of linear link is designed,and the required heating temperature is used to solve the intermediate variable heating power.Finally,inversion calculation is applied in the nonlinear link to solve the required power frequency,so as to achieve the purpose of efficient heating and verify the feasibility and effectiveness of control strategy through simulation.
基金This work was supported in part by the National Natural Science Foundation of China(NSFC)(51537006)European Union’s Horizon 2020 research and innovation programme(774309,MAGNATUDE),WEFO FLEXIS project.
文摘Coupling between electricity systems and heating systems are becoming stronger,leading to more flexible and more complex interactions between these systems.The operation of integrated energy systems is greatly affected,especially when security is concerned.Steady-state analysis methods have been widely studied in recent research,which is far from enough when the slow thermal dynamics of heating networks are introduced.Therefore,an integrated quasi-dynamic model of integrated electricity and heating systems is developed.The model combines a heating network dynamic thermal model and the sequential steady-state models of electricity networks,coupling components,and heating network hydraulics.Based on this model,a simulation method is proposed and quasi-dynamic interactions between electricity systems and heating systems are quantified with the highlights of transport delay.Then the quasi-dynamic interactions were applied using security control to relieve congestion in electricity systems.Results show that both the transport delay and control strategies have significant influences on the quasi-dynamic interactions.
基金support by the National Natural Science Foundation of China(No.51576203)。
文摘Due to the poor heating performance and operating safety in low ambient temperature,traditional Air Source Heat Pump(ASHP)for Electric Vehicles(EVs)has many limits in cold region,which can be solved by the ASHP with refrigerant injection.During the start-up stage of EV in winter,the inlet air temperature of the in-car condenser is the same as the ambient temperature.At this situation,the performance and control strategy of the heat pump require special attention.In the present study,a series of experiments were carried out on the heating performance of the Refrigerant Injection Heat Pump(RIHP)system in start-up stage of EV,at the ambient temperature from–20℃ to–5℃.The effects of compressor speed and injected refrigerant state on the heating performance of the system were discussed in depth.According to the results,the control strategies during start-up stage have been discussed in the end of the article.The study provides a practical control strategy for the RIHP system during the start-up stage of electric vehicles,helping to efficiently operate electric vehicles in cold regions.
文摘increasing penetration of renewable energy sources with a wide range of operating conditions causing power system uncertainties, conventional controllers are incapable of providing proper performance to keep the system stable. However, controllable or dispatchable loads such as electric vehicles (EVs) and heat pumps (HPs) can be utilized for supplementary frequency control. This paper shows the ability of plug-in hybrid EVs, HPs, and batteries (BTs) to contribute in the frequency control of an isolated power system. Moreover, we propose a new online intelligent approach by using a coefficient diagram method (CDM) to enhance the system performance and robustness against uncertainties. The performance of the proposed intelligent CDM control has been compared with the proportional-integral (PI) controller and the superiority of the proposed scheme has been verified in Matiab/Simulink programs.