Different temperatures of water bath was used to extract the intracellular microcystin-LR(MC-LR) of Microcystis aeruginosa. Researching the extraction efficiency under the suitable temperature, so that it could find o...Different temperatures of water bath was used to extract the intracellular microcystin-LR(MC-LR) of Microcystis aeruginosa. Researching the extraction efficiency under the suitable temperature, so that it could find out the best temperature and time for extracting MC-LR from Microcystis aeruginosa cells. Five equal Microcystis aeruginosa was used to find out the best temperature, extracting at 60℃, 70℃, 80℃, 90℃ and 100℃ for 15 minutes, respectively. Results showed that the content of MC-LR extracted with the water under 100℃ was the highest. But meanwhile, the type and the content of impurities was the highest, too. In addition, another six equal Microcystis aeruginosa was extract with the water under 100℃ for 5min, 10 min, 15 min, 20 min, 25 min and 30 min respectively. It was proved that 20 minutes was enough for extracting MC-LR from Microcystis aeruginosa, no long time was needed.展开更多
Natural gas is transported from producing regions to consumption regions by using transmission pipelines at high pressures. At consumption regions, the pressure of natural gas is reduced in city gate stations(CGSs). B...Natural gas is transported from producing regions to consumption regions by using transmission pipelines at high pressures. At consumption regions, the pressure of natural gas is reduced in city gate stations(CGSs). Before the pressure reduction process, the temperature of natural gas is increased usually by using a water bath heater,which burns natural gas as fuel, to protect against freezing of natural gas. These types of heat exchangers have a low efficiency and consume a lot of fuel to generate the required heat. In the current study, the twisted configuration of the heating coil is proposed and investigated to enhance the heat transfer through a water bath heater with a nominal capacity of 1000 m^3·h^-1. Firstly, the implementation procedure is validated with data collected from the CGS of Qaleh-Jiq(located in Golestan province of Iran). A very good agreement is achieved between the obtained results and the real data. Then, three different twist ratios are considered to examine the twisting effects. The proposed technique is evaluated in the terms of velocity, temperature, and pressure variations, and the results are compared with the conventional case, i.e. straight configuration. It is found that both the heat transfer rate and the pressure drop augment as the twist ratio is raised. Finally, it is concluded that the twisted tubes can reduce the length of the gas coil by about 12.5% for the model with low twist ratio, 18.75% for the model with medium twist ratio, and 25% for the model with high twist ratio as compared to the straight configuration.展开更多
In order to effectively and quickly clean the surface of semiconductor silicon wafers, the fluid flow is one of the significant issues. For a batch-type silicon wafer wet cleaning bath, a slim water injection nozzle c...In order to effectively and quickly clean the surface of semiconductor silicon wafers, the fluid flow is one of the significant issues. For a batch-type silicon wafer wet cleaning bath, a slim water injection nozzle consisting of a dual tube was studied, based on theoretical calculations and experiments. A thin inner tube was placed at the optimum position in the water injection nozzle. Such a simple design could make the water injection direction normal and the water velocity profile symmetrical along the nozzle. The water flow in the wet cleaning bath was observed using a blue-colored ink tracer. When the nozzle developed in this study was placed at the bottom of the bath, a fast and symmetrical upward water stream was formed between and around the wafers.展开更多
文摘Different temperatures of water bath was used to extract the intracellular microcystin-LR(MC-LR) of Microcystis aeruginosa. Researching the extraction efficiency under the suitable temperature, so that it could find out the best temperature and time for extracting MC-LR from Microcystis aeruginosa cells. Five equal Microcystis aeruginosa was used to find out the best temperature, extracting at 60℃, 70℃, 80℃, 90℃ and 100℃ for 15 minutes, respectively. Results showed that the content of MC-LR extracted with the water under 100℃ was the highest. But meanwhile, the type and the content of impurities was the highest, too. In addition, another six equal Microcystis aeruginosa was extract with the water under 100℃ for 5min, 10 min, 15 min, 20 min, 25 min and 30 min respectively. It was proved that 20 minutes was enough for extracting MC-LR from Microcystis aeruginosa, no long time was needed.
基金Islamic Azad University(IAU)Shahrood Branch,Shahrood,IranGolestan Province Gas Company,Gorgan,Iran for their sponsorships.
文摘Natural gas is transported from producing regions to consumption regions by using transmission pipelines at high pressures. At consumption regions, the pressure of natural gas is reduced in city gate stations(CGSs). Before the pressure reduction process, the temperature of natural gas is increased usually by using a water bath heater,which burns natural gas as fuel, to protect against freezing of natural gas. These types of heat exchangers have a low efficiency and consume a lot of fuel to generate the required heat. In the current study, the twisted configuration of the heating coil is proposed and investigated to enhance the heat transfer through a water bath heater with a nominal capacity of 1000 m^3·h^-1. Firstly, the implementation procedure is validated with data collected from the CGS of Qaleh-Jiq(located in Golestan province of Iran). A very good agreement is achieved between the obtained results and the real data. Then, three different twist ratios are considered to examine the twisting effects. The proposed technique is evaluated in the terms of velocity, temperature, and pressure variations, and the results are compared with the conventional case, i.e. straight configuration. It is found that both the heat transfer rate and the pressure drop augment as the twist ratio is raised. Finally, it is concluded that the twisted tubes can reduce the length of the gas coil by about 12.5% for the model with low twist ratio, 18.75% for the model with medium twist ratio, and 25% for the model with high twist ratio as compared to the straight configuration.
文摘In order to effectively and quickly clean the surface of semiconductor silicon wafers, the fluid flow is one of the significant issues. For a batch-type silicon wafer wet cleaning bath, a slim water injection nozzle consisting of a dual tube was studied, based on theoretical calculations and experiments. A thin inner tube was placed at the optimum position in the water injection nozzle. Such a simple design could make the water injection direction normal and the water velocity profile symmetrical along the nozzle. The water flow in the wet cleaning bath was observed using a blue-colored ink tracer. When the nozzle developed in this study was placed at the bottom of the bath, a fast and symmetrical upward water stream was formed between and around the wafers.