An electrical resistivity survey was carried out on the household and industrial waste disposal site (landfill) of Akouédo (Central Abidjan) with a view to searching for a possible layer of clay in the stratifica...An electrical resistivity survey was carried out on the household and industrial waste disposal site (landfill) of Akouédo (Central Abidjan) with a view to searching for a possible layer of clay in the stratification which could constitute a protective screen of the aquifer of the Continental Terminal of Abidjan against the migration of leachate. Electrical surveys (SE) carried out according to the Schlumberger configuration showed that the stratigraphy of the area is composed of three to four geoelectric layers depending on the SE positions. The correlation with the lithology of two piezometric boreholes carried out indicates that the lithology of the study area is dominated by clayey sand, sand, sandy clay and clay. The average thickness of accumulated waste varies between 30 and 40 m. The virtual absence of a continuous layer of clay under the waste exposes the Continental Terminal aquifer to contamination by leachate from waste accumulated over several decades in the Akouedo area.展开更多
GaN-based vertical P-i-N diode with mesa edge terminal structure due to electric field crowding effect, the breakdown voltage of the device is significantly reduced. This work investigates three terminal structures, i...GaN-based vertical P-i-N diode with mesa edge terminal structure due to electric field crowding effect, the breakdown voltage of the device is significantly reduced. This work investigates three terminal structures, including deeply etched, bevel, and stepped-mesas terminal structures, to suppress electric field crowding effects at the device and junction edges. Deeply-etched mesa terminal yields a breakdown voltage of 1205 V, i.e., 89% of the ideal voltage. The bevel-mesa terminal achieves about 89% of the ideal breakdown voltage, while the step-mesa terminal is less effective in mitigating electric field crowding, at about 32% of the ideal voltage. This work can provide an important reference for the design of high-power, high-voltage GaN-based P-i-N power devices, finding a terminal protection structure suitable for GaNPiN diodes to further enhance the breakdown performance of the device and to unleash the full potential of GaN semiconductor materials.展开更多
EVT (electric vehicle terminal) has played an important role in EV (electric vehicle) operation. Based on research status of vehicle terminal, EVT brought about in the future should have the following functions: (1) f...EVT (electric vehicle terminal) has played an important role in EV (electric vehicle) operation. Based on research status of vehicle terminal, EVT brought about in the future should have the following functions: (1) fundamental functions, including real-time monitoring of batteries, guidance in station, position guidance of charging/battery-swap infrastructures, communication with OMS (operation and management system), and so on;(2) advanced functions, including but not limited to multi-media entertainment, subscribing and payment for charging/battery-swap, identification, and safety control during driving. Complete design of new-generation EVT in software structure and hardware architecture is proposed;a new idea of the application of EVT in EV industry is put forward.展开更多
This paper deals with an integration of directly measured electrical parameters with data acquired by data communication from protections and terminals into an advanced monitoring system. Based on the periodic test, t...This paper deals with an integration of directly measured electrical parameters with data acquired by data communication from protections and terminals into an advanced monitoring system. Based on the periodic test, the authors of this paper present the possibility of an extended evaluation and more accurate analysis of transient and failure events. For periodical testing, as implemented during the commissioning of power plants in the Czech Republic, a monitoring system of electrical equipment has been used, to record the courses of important electrical parameters and thus, proving the proper functioning of complex technological systems in various operation modes. Data from monitoring system were used to prove the successful results of the test or as a base data for further analysis of failures. The monitoring system has proved itself as a very useful device also when recording unexpected failure events, the cause of which was very quickly and accurately detected by the follow-up analysis. Initially, only the voltage and current data from measuring transformers, analogue transducers and contact relays were used as input data for the monitoring system. After the implementation of new digital protection technology and controlling terminals with inner data recorder, the data from digital devices could be also utilized for the monitoring system.展开更多
The chronic effects of carboxyl-terminal polypeptide of Cardiotrophin-1(CT-1-CP) on ventricular electrical remodeling were investigated. CT-1-CP, which contains 16 amino acids in sequence of the C-terminal of Cardio...The chronic effects of carboxyl-terminal polypeptide of Cardiotrophin-1(CT-1-CP) on ventricular electrical remodeling were investigated. CT-1-CP, which contains 16 amino acids in sequence of the C-terminal of Cardiotrophin-1, was selected and synthesized, and then administered to Kunming mice(aged 5 weeks) by intraperitoneal injection(500 ng·g^-1·day^-1)(4 groups, n=10 and female: male=1:1 in each group) for 1, 2, 3 and 4 weeks, respectively. The control group(n=10, female:male=1:1) was injected by physiological saline for 4 weeks. The epicardial monophasic action potential(MAP) was recorded by using a contact-type MAP electrode placed vertically on the left ventricular(LV) epicardium surface, and the electrocardiogram(ECG) signal in lead Ⅱ was monitored synchronously. ECG intervals(RR, PR, QRS and QT) and the amplitude of MAP(Am), the maximum upstroke velocity(Vmax), as well as action potential durations(APDs) at different repolarization levels(APD30, APD50, APD70, and APD90) of MAP were determined and analyzed in detail. There were no significant differences in RR and P intervals between CT-1-CP-treated groups and control group, but the PR segment and the QRS complex were greater in the former than in the latter(F=2.681 and 5.462 respectively, P〈0.05). Though QT interval and the corrected QT interval(QTc) were shorter in CT-1-CP-treated groups than in control group, the QT dispersion(QTd) of them was greater in the latter than in the former(F=3.090, P〈0.05) and increased with the time. The ECG monitoring synchronously with the MAP showed that the compression of MAP electrode on the left ventricular epicardium induced performance similar to myocardium ischemia. As compared with those before chest-opening, the PR segment and QT intervals remained basically unchanged in control group, but prolonged significantly in all CT-1-CP-treated groups and the prolongation of QT intervals increased gradually along with the time of exposure to CT-1-CP. The QRS complex had no significant change in control group, one-week and three-week CT-1-CP-treated groups, but prolonged significantly in two-week and four-week CT-1-CP-treated groups. Interestingly, the QTd after chest-opening was significantly greater than that before chest-opening in control group(t=5.242, P〈0.01), but decreased along with the time in CT-1-CP-treated groups. The mean MAP amplitude, Vmax and APD were greater in CT-1-CP-treated groups than those in control group, and became more obvious along with the time. The APD in four CT-1-CP-treat groups was prolonged mainly in middle to final repolarization phase. The difference among these groups became significant in middle phase(APD50)(F=6.076, P〈0.01) and increased furthermore in late and final phases(APD70: F=10.054; APD90: F=18.691, P〈0.01) along with the time of injection of CT-1-CP. The chronic action of CT-1-CP might induce the adapting alteration in cardiac conductivity and ventricular repolarization. The amplitude and the Vmax of the anterior LV epicardial MAP increased obviously, and the APD prolonged mainly in late and final phase of repolarization.展开更多
A regional study connecting geolelectrical surveys with geology and hydrogeology was carried out in the western part of the Iullemmeden basin, precisely in the Dosso region in Niger. One hundred and four (104) vertica...A regional study connecting geolelectrical surveys with geology and hydrogeology was carried out in the western part of the Iullemmeden basin, precisely in the Dosso region in Niger. One hundred and four (104) vertical electrical sounds have been realized, among them nineteen representative were thus be used as parametric surveys. The local resistivity values of the geological formations of Quaternary range from 100 Ω⋅m to 1000 Ω⋅m (sands and lateritic sandstones). The Oligo-Miocene formation of the Continental terminal (Ct) shows resistivity values ranging from 1 to 5 Ω⋅m (brackish groundwaters) to 1500 Ω⋅m (clay sandstones) while the Upper Cretaceous formation of the Continental “hamadien” (Ch) indicates values ranging from 20 Ω⋅m (sandy clay) to 5000 Ω⋅m (clayey sandstones). The geological formations of Paleocene have values from 2 Ω⋅m (marls) to 60 Ω⋅m (calcareous marl), while the Precambrian basement exhibits values of granite around 300 Ω⋅m to 60,000 Ω⋅m. The update of the structural settings reveals many faults in the study area which explain both the shape of the basin and the geometry of the aquifers. Tectonics is also consistent with the hydraulic characteristics of aquifers. In addition, brackish groundwaters were identified as perched aquifer groundwaters in different depths in Dosso region. They probably come from the marine brines during the regression of the Paleocene Sea.展开更多
文摘An electrical resistivity survey was carried out on the household and industrial waste disposal site (landfill) of Akouédo (Central Abidjan) with a view to searching for a possible layer of clay in the stratification which could constitute a protective screen of the aquifer of the Continental Terminal of Abidjan against the migration of leachate. Electrical surveys (SE) carried out according to the Schlumberger configuration showed that the stratigraphy of the area is composed of three to four geoelectric layers depending on the SE positions. The correlation with the lithology of two piezometric boreholes carried out indicates that the lithology of the study area is dominated by clayey sand, sand, sandy clay and clay. The average thickness of accumulated waste varies between 30 and 40 m. The virtual absence of a continuous layer of clay under the waste exposes the Continental Terminal aquifer to contamination by leachate from waste accumulated over several decades in the Akouedo area.
文摘GaN-based vertical P-i-N diode with mesa edge terminal structure due to electric field crowding effect, the breakdown voltage of the device is significantly reduced. This work investigates three terminal structures, including deeply etched, bevel, and stepped-mesas terminal structures, to suppress electric field crowding effects at the device and junction edges. Deeply-etched mesa terminal yields a breakdown voltage of 1205 V, i.e., 89% of the ideal voltage. The bevel-mesa terminal achieves about 89% of the ideal breakdown voltage, while the step-mesa terminal is less effective in mitigating electric field crowding, at about 32% of the ideal voltage. This work can provide an important reference for the design of high-power, high-voltage GaN-based P-i-N power devices, finding a terminal protection structure suitable for GaNPiN diodes to further enhance the breakdown performance of the device and to unleash the full potential of GaN semiconductor materials.
文摘EVT (electric vehicle terminal) has played an important role in EV (electric vehicle) operation. Based on research status of vehicle terminal, EVT brought about in the future should have the following functions: (1) fundamental functions, including real-time monitoring of batteries, guidance in station, position guidance of charging/battery-swap infrastructures, communication with OMS (operation and management system), and so on;(2) advanced functions, including but not limited to multi-media entertainment, subscribing and payment for charging/battery-swap, identification, and safety control during driving. Complete design of new-generation EVT in software structure and hardware architecture is proposed;a new idea of the application of EVT in EV industry is put forward.
文摘This paper deals with an integration of directly measured electrical parameters with data acquired by data communication from protections and terminals into an advanced monitoring system. Based on the periodic test, the authors of this paper present the possibility of an extended evaluation and more accurate analysis of transient and failure events. For periodical testing, as implemented during the commissioning of power plants in the Czech Republic, a monitoring system of electrical equipment has been used, to record the courses of important electrical parameters and thus, proving the proper functioning of complex technological systems in various operation modes. Data from monitoring system were used to prove the successful results of the test or as a base data for further analysis of failures. The monitoring system has proved itself as a very useful device also when recording unexpected failure events, the cause of which was very quickly and accurately detected by the follow-up analysis. Initially, only the voltage and current data from measuring transformers, analogue transducers and contact relays were used as input data for the monitoring system. After the implementation of new digital protection technology and controlling terminals with inner data recorder, the data from digital devices could be also utilized for the monitoring system.
文摘The chronic effects of carboxyl-terminal polypeptide of Cardiotrophin-1(CT-1-CP) on ventricular electrical remodeling were investigated. CT-1-CP, which contains 16 amino acids in sequence of the C-terminal of Cardiotrophin-1, was selected and synthesized, and then administered to Kunming mice(aged 5 weeks) by intraperitoneal injection(500 ng·g^-1·day^-1)(4 groups, n=10 and female: male=1:1 in each group) for 1, 2, 3 and 4 weeks, respectively. The control group(n=10, female:male=1:1) was injected by physiological saline for 4 weeks. The epicardial monophasic action potential(MAP) was recorded by using a contact-type MAP electrode placed vertically on the left ventricular(LV) epicardium surface, and the electrocardiogram(ECG) signal in lead Ⅱ was monitored synchronously. ECG intervals(RR, PR, QRS and QT) and the amplitude of MAP(Am), the maximum upstroke velocity(Vmax), as well as action potential durations(APDs) at different repolarization levels(APD30, APD50, APD70, and APD90) of MAP were determined and analyzed in detail. There were no significant differences in RR and P intervals between CT-1-CP-treated groups and control group, but the PR segment and the QRS complex were greater in the former than in the latter(F=2.681 and 5.462 respectively, P〈0.05). Though QT interval and the corrected QT interval(QTc) were shorter in CT-1-CP-treated groups than in control group, the QT dispersion(QTd) of them was greater in the latter than in the former(F=3.090, P〈0.05) and increased with the time. The ECG monitoring synchronously with the MAP showed that the compression of MAP electrode on the left ventricular epicardium induced performance similar to myocardium ischemia. As compared with those before chest-opening, the PR segment and QT intervals remained basically unchanged in control group, but prolonged significantly in all CT-1-CP-treated groups and the prolongation of QT intervals increased gradually along with the time of exposure to CT-1-CP. The QRS complex had no significant change in control group, one-week and three-week CT-1-CP-treated groups, but prolonged significantly in two-week and four-week CT-1-CP-treated groups. Interestingly, the QTd after chest-opening was significantly greater than that before chest-opening in control group(t=5.242, P〈0.01), but decreased along with the time in CT-1-CP-treated groups. The mean MAP amplitude, Vmax and APD were greater in CT-1-CP-treated groups than those in control group, and became more obvious along with the time. The APD in four CT-1-CP-treat groups was prolonged mainly in middle to final repolarization phase. The difference among these groups became significant in middle phase(APD50)(F=6.076, P〈0.01) and increased furthermore in late and final phases(APD70: F=10.054; APD90: F=18.691, P〈0.01) along with the time of injection of CT-1-CP. The chronic action of CT-1-CP might induce the adapting alteration in cardiac conductivity and ventricular repolarization. The amplitude and the Vmax of the anterior LV epicardial MAP increased obviously, and the APD prolonged mainly in late and final phase of repolarization.
文摘A regional study connecting geolelectrical surveys with geology and hydrogeology was carried out in the western part of the Iullemmeden basin, precisely in the Dosso region in Niger. One hundred and four (104) vertical electrical sounds have been realized, among them nineteen representative were thus be used as parametric surveys. The local resistivity values of the geological formations of Quaternary range from 100 Ω⋅m to 1000 Ω⋅m (sands and lateritic sandstones). The Oligo-Miocene formation of the Continental terminal (Ct) shows resistivity values ranging from 1 to 5 Ω⋅m (brackish groundwaters) to 1500 Ω⋅m (clay sandstones) while the Upper Cretaceous formation of the Continental “hamadien” (Ch) indicates values ranging from 20 Ω⋅m (sandy clay) to 5000 Ω⋅m (clayey sandstones). The geological formations of Paleocene have values from 2 Ω⋅m (marls) to 60 Ω⋅m (calcareous marl), while the Precambrian basement exhibits values of granite around 300 Ω⋅m to 60,000 Ω⋅m. The update of the structural settings reveals many faults in the study area which explain both the shape of the basin and the geometry of the aquifers. Tectonics is also consistent with the hydraulic characteristics of aquifers. In addition, brackish groundwaters were identified as perched aquifer groundwaters in different depths in Dosso region. They probably come from the marine brines during the regression of the Paleocene Sea.