期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Application of chaotic modulation to AC motors for electro magnetic interference suppression
1
作者 崔巍 王建宽 江建中 《Journal of Shanghai University(English Edition)》 CAS 2007年第5期502-505,共4页
Instead of avoiding occurrence of chaos in motor drives, chaos is positively utilized in this paper. A new chaotic pulse width modulation (PWM) scheme is proposed and implemented for AC motors, which functions to si... Instead of avoiding occurrence of chaos in motor drives, chaos is positively utilized in this paper. A new chaotic pulse width modulation (PWM) scheme is proposed and implemented for AC motors, which functions to significantly suppress harmonic peaks and hence acoustic noise. The key is to employ the Chua's circuit for generating a desired chaotic sequence. By using a practical induction motor, computer simulation and experimental results verify that the chaotic PWM has advantages of harmonic peak suppression and simple hardware implementation over the conventional PWM and random PWM. 展开更多
关键词 electro magnetic interference (EMI) Chua's circuit chaotic pulse width modulation (PWM).
下载PDF
Modeling and Analysis of Pulse Skip Modulation 被引量:2
2
作者 罗萍 张波 《Journal of Electronic Science and Technology of China》 2006年第1期1-7,共7页
The state space average model and the large signal models of Pulse Skip Modulation (PSM) mode are given in this paper. Farther more, based on these models and simulations of PSM converter circuits, the analysis of t... The state space average model and the large signal models of Pulse Skip Modulation (PSM) mode are given in this paper. Farther more, based on these models and simulations of PSM converter circuits, the analysis of the characteristics of PSM converter is described in this paper, of which include efficiency, frequency spectrum analysis, output voltage ripple, response speed and interference rejection capability. Compared with PWM control mode, PSM converter has high efficiency, especially with fight loads, quick response, good interference rejection and good EMC characteristic. Improved PSM slightly, it could be a kind of good independent regulating mode during the whole operating process for a DC-DC converter. Finally, some experimental results are also presented in this paper. 展开更多
关键词 Pulse Skip Modulation (PSM) state space averaged model large signalmodel efficiency electro Magnetic Interference (EMI) output voltage ripple improved PSM
下载PDF
Influencing Factors of Preparation of Al-Mg-Sc Master Alloy
3
作者 张军 张宗华 张桂芳 《Journal of Rare Earths》 SCIE EI CAS CSCD 2007年第S2期215-217,共3页
Through the experiment, the reduced temperature, the containing scandium quantity of the fused salt, the agitated intensity and the restoring time that influence the rate of receives of scandium, and determined the te... Through the experiment, the reduced temperature, the containing scandium quantity of the fused salt, the agitated intensity and the restoring time that influence the rate of receives of scandium, and determined the technological conditions which uses the method of hot Al-Mg restoring anhydrous the chloride of scandium to prepare the Al-Mg-Sc master alloy. The best experimental technological conditions are that the master alloy can contains 8.0% of scandium while the restoring temperature is at 900 ℃, the restoring time is 20 min and the agitated time is a half minute. When the method of the fused salt covered with bell, agitated and pressed the argon is used in the expansion tests, the agitated number is 4 times and the average receives rate of Sc is 90.0%. 展开更多
关键词 RECRYSTALLIZATION AL3SC Al-Sc alloy electro magnetics rare earths
下载PDF
Recrystallization and Morphology of Microstructure in Al-Sc Alloys
4
作者 张军 张宗华 《Journal of Rare Earths》 SCIE EI CAS CSCD 2007年第S2期211-214,共4页
Minor addition of Sc to aluminum results in the rapid precipitation of homogeneously distributed Al3Sc dispersoids. The presence of Al3Sc dispersoids is more effective recrystallization inhibitors. Our work establishe... Minor addition of Sc to aluminum results in the rapid precipitation of homogeneously distributed Al3Sc dispersoids. The presence of Al3Sc dispersoids is more effective recrystallization inhibitors. Our work established the precipitation of homogeneously distributed Al3Sc dispersoids, which are coherent with the matrix, have the L12 structure. It was also established that the addition of Sc was effective in improving the recrystallization resistance. 展开更多
关键词 RECRYSTALLIZATION AL3SC Al-Sc alloy electro magnetics
下载PDF
Evaluation of cable tension sensors of FAST reflector from the perspective of EMI
5
作者 朱明 Wang Qiming +2 位作者 Dennis Egan Wu Mingchang Sun Xiao 《High Technology Letters》 EI CAS 2016年第2期135-141,共7页
The active reflector of FAST ( five-hundred-meter aperture spherical radio telescope) is suppor- ted by a ring beam and a cable-net structure, in which nodes are actively controlled to form series of real-time parab... The active reflector of FAST ( five-hundred-meter aperture spherical radio telescope) is suppor- ted by a ring beam and a cable-net structure, in which nodes are actively controlled to form series of real-time paraboloids. To ensure the security and stability of the supporting structure, tension must be monitored for some typical cables. Considering the stringent requirements in accuracy and long- term stability, magnetic flux sensor, vibrating wire strain gauge and fiber bragg grating strain gauge are screened for the cable tension monitoring of the supporting cable-net. Specifically, receivers of radio telescopes have strict restriction on electro magnetic interference (EMI) or radio frequency in- terference (RFI). These three types of sensors are evaluated from the view of EMIfRFI. Firstly, these fundamentals are theoretically analyzed. Secondly, typical sensor signals are collected in the time and analyzed in the frequency domain, which shows the characteristic in the frequency domain. Finally, typical sensors are tested in an anechoic chamber to get the EMI levels. Theoretical analysis shows that Fiber Bragg Grating strain gauge itself will not lead to EMI/RFI. According to GJB151 A, frequency domain analysis and test results show that for the vibrating wire strain gauge and magnetic flux sensor themselves, testable EMIfRF1 levels are typically below the background noise of the ane- choic chamber. FAST finally choses these three sensors as the monitoring sensors of its cable ten- sion. The proposed study is also a reference to the monitoring equipment selection of other radio tele- scopes and large structures. 展开更多
关键词 five-hundred-meter aperture spherical radio telescope (FAST) cable tension mo-nitoring magnetic flux vibrating wire fiber Bragg electro magnetic interference (EMI)
下载PDF
RESEARCH ON INPUT IMPEDANCE OF DIPOLE ANTENNA IN GTEM CELL
6
作者 Xing Shuguang Lv Xiaode Ding Chibiao 《Journal of Electronics(China)》 2014年第6期603-608,共6页
The formula of input impedance of dipole antenna in Gigahertz Transverse ElectroM agnetic(GTEM) cell based on the dyadic Green's function is first obtained in this paper. The validation of the formula is verified ... The formula of input impedance of dipole antenna in Gigahertz Transverse ElectroM agnetic(GTEM) cell based on the dyadic Green's function is first obtained in this paper. The validation of the formula is verified by the results of theoretical derivation and simulation with well agreements. In comparison with the formula of input impedance in free space, the relationship between the change of input impedance with the length of antenna and the position of antenna in GTEM cell is obtained. In addition, some meaningful conclusions are presented, which not only can be referred by the further research of ElectroM agnetic Interference(EMI) measurements in GTEM cell, but also provide the theoretical basis for testing compensation and error analysis. 展开更多
关键词 electro Magnetic Interference(EMI) measurement Gigahertz Transverse electroM agnetic(GTEM) cell Dipole antenna Input impedance Dyadic Green’s function
下载PDF
Study on TRV of circuit breaker in two substation operational ways and its countermeasure
7
作者 李国亮 夏文华 李微微 《Journal of Measurement Science and Instrumentation》 CAS 2012年第4期393-396,共4页
To verify a vacuum breaker's feasibility,when a transformer substation chooses a vacuum circuit breaker,it takes two different actual operational ways to cut off a transformer.This paper,using the power system com... To verify a vacuum breaker's feasibility,when a transformer substation chooses a vacuum circuit breaker,it takes two different actual operational ways to cut off a transformer.This paper,using the power system computer aided design/electro magnetic transient in DC system(PSCAD/EMTDC)software,simulates the substation system and studies transient recovery voltage(TRV)caused by the two different ways which can cut off a with load transformer or a no-load transformer.Simulation and calculation results show that TRV indexes of the first way are much higher than that of the second one,and their TRV indexes are both in a permissible range.The breaker is proved to be available.Besides,this paper proves that paralleling resistance has a good effect when the indexes exceed the standard.The resistance value depends on specific circumstances. 展开更多
关键词 transient recovery voltage(TRV) power system computer aided design/electro magnetic transient in DC system (PSCAD/EMTDC) TRANSFORMER vacuum circuit breaker
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部