The modulation depth, defined according to practical modulation results, which changes with the microwave power and its frequency, is significant for systems utilizing the frequency-shift characteristic of the LiNbO3 ...The modulation depth, defined according to practical modulation results, which changes with the microwave power and its frequency, is significant for systems utilizing the frequency-shift characteristic of the LiNbO3 waveguide Electro-Optic Intensity Modulator (EOIM). By analyzing the impedance mismatch between the microwave source and the EOIM, the effective voltage applied to the RF port of the EOIM is deprived from the microwave power and its frequency. Associating with analyses of the phase velocity mismatch between the microwave and the optical wave, the theoretical modulation depth has been obtained, which is verified by experimental results. We provide a method to choose the appropriate modulation depth to optimize the desired sideband through proper transmission bias for the system based on the frequency-shift characteristic of the EOIM.展开更多
High-speed and wide-band LiNbO3 waveguide electro-optic intensity modulator has drawn great attention in the field of optical fiber communication and sensor. This paper reports the research results on the measurement ...High-speed and wide-band LiNbO3 waveguide electro-optic intensity modulator has drawn great attention in the field of optical fiber communication and sensor. This paper reports the research results on the measurement of frequency shift characteristics of Mach-Zehnder electro-optic intensity modulator. Two measurement methods of frequency shift characteristics for high and low frequency modulations are studied in theory and experiment and demonstrate different results. The realization of a multi-wavelength optical source based on Mach-Zehnder electro-optic intensity modulator has been introduced. The technique to reach the maximum intensity for interesting shift frequency, particularly for heterodyne detection of Brillouin distributed optical fiber sensing, has been given.展开更多
We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are th...We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are theoretically and experimentally analyzed and investigated. Both the electric and magnetic fields can manipulate the molecular arrangement of LC to array a certain angle without changing the refractive index of the LC. Therefore, light loss in the PCF varies with the electric and magnetic fields whereas the peak wavelengths remain constant. The experimental results show that the transmission intensity decreases with the increase of the electric and magnetic fields. The cut-off electric field is 0.899 V/um at 20 Hz and the cut-off magnetic field is 195 m T. This simple and compacted optical modulator will have a great prospect in sensing applications.展开更多
A bunch arrival-time monitor(BAM) based on an electro-optical intensity modulation scheme is currently under development at Shanghai Soft X-ray Free-Electron Laser to meet the high-resolution requirements for bunch st...A bunch arrival-time monitor(BAM) based on an electro-optical intensity modulation scheme is currently under development at Shanghai Soft X-ray Free-Electron Laser to meet the high-resolution requirements for bunch stability. The BAM uses a radio frequency signal generated by a pickup cavity to modulate the reference laser pulses in an electro-optical intensity modulator(EOM), and the bunch arrival-time information is derived from the amplitude change of the laser pulse after laser pulse modulation.EOM is a key optical component in the BAM system.Through the basic principle analysis of BAM, many parameters of the EOM are observed to affect the measurement resolution of the BAM system. Therefore, a systematic analysis of the EOM is crucial. In this paper, we present two schemes to compare and analyze an EOM and provide a reference for selecting a new version of the EOM.展开更多
This paper demonstrates the intensity modulation characters of orthogonally polarized HeNe lasers with different optical feedback level generated by the variable reflectivity of external reflector. The modulation dept...This paper demonstrates the intensity modulation characters of orthogonally polarized HeNe lasers with different optical feedback level generated by the variable reflectivity of external reflector. The modulation depths of the orthogonally polarized frequencies are increased when the optical feedback level becomes strong. It also observes that the modulation amplitudes are different for different external cavity length. Based on the vectorial extension of Lamb's semi-classical theory, it finds that the calculations are consistent with the experimental results.展开更多
Objective: Juvenile Nasopharyngeal Angiofibroma (JNA) is a benign neoplasm with a high vascularity component, greater craniofacial involvement in adolescent patients, and aggressive local behaviour. In unresectable pa...Objective: Juvenile Nasopharyngeal Angiofibroma (JNA) is a benign neoplasm with a high vascularity component, greater craniofacial involvement in adolescent patients, and aggressive local behaviour. In unresectable patients, radiotherapy is a therapeutic option for local control. Our aim in this study was to analyze the clinical benefit and local control provided by two modalities of radiotherapy: the Three-Dimensional Conformal (3DC) technique and volumetric modulated arc therapy (VMAT), applied to pediatric patients with JNA considered unresectable and non-recurrent. Methods: In retrospective study, the information was recorded from pediatric patients with a diagnosis of non-recurrent and unresectable JNA treated with radiotherapy at the Oncology Hospital of the National Medical Center SXXI of Mexico City, from March 2010 to March 2021. Radiotherapy management and its association with clinical outcomes of tumour control, and symptoms were assessed. In addition, an evaluation of acute and chronic toxicity was performed. Results: It was found that the median age was 14 years. 9 patients (37.5%) underwent 3DC and 15 (62.5%) VMAT. In terms of local control, and progression-free survival, we did not find significant difference between radiotherapy modalities (p ≤ 0.57). Acute toxicity for both modalities presented statistical differences for radio epithelitis (p = 0.03). Only Grade I and II radiation-induced acute toxicity was observed. Regarding chronic toxicity, statistical significance was observed for craniofacial hypoplasia, in relation to its absence in the VMAT group (p = 0.001). Conclusion: The VMAT presents improvements in dosimetry parameters that improve patient toxicity. In both techniques adequate tumour control was observed, however, the rarity of the disease is a limitation to establish the most appropriate therapeutic technique.展开更多
The characteristics of a conventional LiNbO3 intensity modulator made up of a Mach-Zehnder(MZ) type annealed proton exchange(APE) waveguide and coplanar waveguide(CPW) modulation electrode are presented. The APE waveg...The characteristics of a conventional LiNbO3 intensity modulator made up of a Mach-Zehnder(MZ) type annealed proton exchange(APE) waveguide and coplanar waveguide(CPW) modulation electrode are presented. The APE waveguide characteristics and their relations with process parameters are analyzed. At the same time, the electrical characteristics of modulation electrode, such as modulation voltage, microwave effective index associated with modulation bandwidth, characteristics impedance, are also investigated in detail.展开更多
The novel BaTiO3/BiFeO3/TiO2 multilayer heterojunction is prepared on a fluorine-doped tinoxide(FTO) substrate by the sol–gel method. The results indicate that the Pt/Ba TiO3/BiFeO3/TiO2/FTO heterojunction exhibits s...The novel BaTiO3/BiFeO3/TiO2 multilayer heterojunction is prepared on a fluorine-doped tinoxide(FTO) substrate by the sol–gel method. The results indicate that the Pt/Ba TiO3/BiFeO3/TiO2/FTO heterojunction exhibits stable bipolar resistive switching characteristic, good retention performance, and reversal characteristic. Under different pulse voltages and light fields, four stable resistance states can also be realized. The analysis shows that the main conduction mechanism of the resistive switching characteristic of the heterojunction is space charge limited current(SCLC) effect. After the comprehensive analysis of the band diagram and the P–E ferroelectric property of the multilayer heterojunction, we can deduce that the SCLC is formed by the effect of the oxygen vacancy which is controlled by ferroelectric polarizationmodulated change of interfacial barrier. And the effective photo-generated carrier also plays a regulatory role in resistance state(RS), which is formed by the double ferroelectric layer Ba TiO3/BiFeO3 under different light fields. This research is of potential application values for developing the multi-state non-volatile resistance random access memory(RRAM) devices based on ferroelectric materials.展开更多
The effect on intensity correlation time T by input signal is studied for gain-noise model of a single-mode laser driven by colored pump noise and colored quantum noise with colored cross-correlation with a bias signa...The effect on intensity correlation time T by input signal is studied for gain-noise model of a single-mode laser driven by colored pump noise and colored quantum noise with colored cross-correlation with a bias signal modulation in this paper. By using the linear approximation method, we detect that there exists maximum (i.e., resonance) in the curve of the intensity correlation time T upon bias current io when the noise correlation coefficient λ is positive; and there exists minimum (i.e., suppression) in the T-io curve when λ is negative. And whenλ is zero, T increases monotonously with increasing io. Furthermore, the curve of T upon the signal frequency Ω is also studied. Our study shows that no matter what the value of λ is, there exists minimum (i.e., suppression) in the T-Ω curve.展开更多
Using a pump with a multi-line spectrum to broaden the Brillouin gain bandwidth is an effective way to achieve lowdistortion amplification with high gain. Here, we theoretically and experimentally investigate the gene...Using a pump with a multi-line spectrum to broaden the Brillouin gain bandwidth is an effective way to achieve lowdistortion amplification with high gain. Here, we theoretically and experimentally investigate the generation of a broadband Brillouin gain spectrum based on multi-frequency intensity modulation in an optical fiber. The arbitrary bandwidth of the Brillouin gain spectrum of stimulated Brillouin scattering(SBS) can be obtained as expected. In our experiment, a broadband Brillouin gain spectrum with a bandwidth of about 200 MHz is demonstrated. We also achieve a low-distortion amplification of a weak signal, whose maximum magnification is 65 d B for a-68-dBm input power signal.展开更多
By using the linear approximation method, the intensity correlation function is calculated for a single-mode laser modulated by a bias signal and driven by colored pump and quantum noises with colored cross-correlatio...By using the linear approximation method, the intensity correlation function is calculated for a single-mode laser modulated by a bias signal and driven by colored pump and quantum noises with colored cross-correlation. We found that, when the correlation time between the two noises is very short, the behavior of the intensity correlation function versus the time, in addition to decreasing monotonously, also exhibits several cases, such as one maximum, one minimum, and two extrema. When the correlation time between the two noises is very long, the behavior of the intensity correlation function exhibits oscillation and the envelope is similar to the case of short cross-correlation time.展开更多
We propose and analyze a novel Si-based electro-optic modulator with an improved metal-oxide-semiconductor (MOS) capacitor configuration integrated into silicon-on-insulator (SOl). Three gate-oxide layers embedded...We propose and analyze a novel Si-based electro-optic modulator with an improved metal-oxide-semiconductor (MOS) capacitor configuration integrated into silicon-on-insulator (SOl). Three gate-oxide layers embedded in the silicon waveguide constitute a triple MOS capacitor structure, which boosts the modulation efficiency compared with a single MOS capacitor. The simulation results demonstrate that the Vπ Lπ product is 2. 4V · cm. The rise time and fall time of the proposed device are calculated to be 80 and 40ps from the transient response curve, respectively,indicating a bandwidth of 8GHz. The phase shift efficiency and bandwidth can be enhanced by rib width scaling.展开更多
A Mach-Zehnder(MZ) electro-optic(EO) modulator are real iz ed,with three optical layers as polymer materials.The functional layer is the co rona poled crosslinkable polyurethane.The ridge waveguide is fabricated by us...A Mach-Zehnder(MZ) electro-optic(EO) modulator are real iz ed,with three optical layers as polymer materials.The functional layer is the co rona poled crosslinkable polyurethane.The ridge waveguide is fabricated by using the spin-coating,poling,photolithography and oxygen reactive ion etching(RIE) techniques.The mode and the modulation properties of these devices are demonstra ted in a micron control system,while the light source works at the wavelength of 1 31 or 1 55 micron.展开更多
Although many studies have investigated intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC),sample sizes in the reported studies are usually small and different in outcomes in different T a...Although many studies have investigated intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC),sample sizes in the reported studies are usually small and different in outcomes in different T and N subgroups are seldom analyzed.Herein,we evaluated the outcomes of NPC patients treated with IMRT and further explored treatment strategy to improve such outcome.We collected clinical data of 865 NPC patients treated with IMRT alone or in combination with chemotherapy,and classified all cases into the following prognostic categories according to different TNM stages:early stage group (T1-2N0-1M0),advanced local disease group (T3-4N0-1M0),advanced nodal disease group (T1-2N2-3M0),and advanced locoregional disease group (T3-4N2-3M0).The 5-year overall survival (OS),local relapse-free survival (LRFS),and distant metastases-free survival (DMFS) were 83.0%,90.4%,and 84.0%,respectively.The early disease group had the lowest treatment failure rate,with a 5-year OS of 95.6%.The advanced local disease group and advanced nodal disease group had similar failure pattern and treatment outcomes as well as similar hazard ratios for death (4.230 and 4.625,respectively).The advanced locoregional disease group had the highest incidence of relapse and death,with a 5-year DMFS and OS of 62.3% and 62.2%,respectively,and a hazard ratio for death of 10.402.Comparing with IMRT alone,IMRT in combination with chemotherapy provided no significant benefit to locoregionally advanced NPC.Our results suggest that the decision of treatment strategy for NPC patients should consider combinations of T and N stages,and that IMRT alone for early stage NPC patients can produce satisfactory results.However,for advanced local,nodal,and locoregional disease groups,a combination of chemotherapy and radiotherapy is recommended.展开更多
Aims: The EORTC-NCI study investigating the addition of temozolomide trial to standard radiation therapy has demonstrated improved duration of survival in patients with Glioblastoma multiforme (GBM). With longer survi...Aims: The EORTC-NCI study investigating the addition of temozolomide trial to standard radiation therapy has demonstrated improved duration of survival in patients with Glioblastoma multiforme (GBM). With longer survival duration, there is the potential for latent RT morbidity, not previously seen in historical patients. This study evaluates the potential dosimetric advantages of utilising IMRT over 3D-conformal RT in such patients. Methods: 10 consecutive patients with GBM formally screened for a clinical study over a two-month period were planned and treated with IMRT utilising daily on-board imaging (OBI). The EORTC protocol dosimetric criteria and constraints were used in target delineation and planning. For each patient, a 3DCRT plan was also produced. Endpoints for dosimetric evaluation analysed related to tumour dose: mean PTV60 dose (mPTV60Dose), Conformity Index (CI);and normal tissue dose: mean normal brain dose (mBrainDose) and V40 Brain (Brainv40). IGRT endpoints were the median isocentre shifts required in 3 axes measured in one direction. The variation between the IMRT and 3DCRT dosimetric endpoints was examined using Wilcoxon analysis. Results: The 10 patients had tumours located in temporal (3), parietal (3), occipital (2) and callosal (2) regions. The median PTV and normal brain volumes were 308.1 cm3 and 1077.5 cm3 respectively. The IMRT dosimetry was significantly improved in all endpoints specifically CI (p = 0.002), mPTV60Dose (p = 0.004), mBrainDose (p = 0.002) and Brainv40 (p = 0.019). OBI directed isocentre measurements in the patient group were available for 230 treatments. The median shifts (and 95% C.I.s) were 0.1 cm vertical (0.1 - 0.2), 0.1 cm longitudinal (0.1 - 0.2) and 0.2 cm lateral (0.2 - 0.2). At a minimum follow-up of 2 years’ post diagnosis, the median survival of the group is 18.0 months (95% CI: 13.4 - 22.6 months). Conclusion: IMRT for GBM produces significant dosimetric advantages in relation to planning target volume and normal tissue dose compared with 3D conformal plans. The data also confirm the accuracy of IMRT technique for CNS with IGRT delivery utilising OBI demonstrating minimal deviation from planned to treated isocentre.展开更多
AIM:To evaluate impact of radiation therapy dose escalation through intensity modulated radiation therapy with simultaneous integrated boost(IMRT-SIB).METHODS:We retrospectively reviewed the patients who underwent fou...AIM:To evaluate impact of radiation therapy dose escalation through intensity modulated radiation therapy with simultaneous integrated boost(IMRT-SIB).METHODS:We retrospectively reviewed the patients who underwent four-dimensional-based IMRT-SIBbased neoadjuvant chemoradiation protocol.During the concurrent chemoradiation therapy,radiation therapy was through IMRT-SIB delivered in 28 consecutive daily fractions with total radiation doses of 56 Gy to tumor and 5040 Gy dose-painted to clinical tumor volume,with a regimen at the discretion of the treating medical oncologist.This was followed by surgical tumor resection.We analyzed pathological completion response(p CR) rates its relationship with overall survival and event-freesurvival.RESULTS:Seventeen patients underwent dose escalation with the IMRT-SIB protocol between 2007 and 2014 and their records were available for analysis.Among the IMRT-SIB-treated patients,the toxicity appeared mild,the most common side effects were grade 1-3 esophagitis(46%) and pneumonitis(11.7%).There were no cardiac events.The Ro resection rate was 94%(n = 16),the p CR rate was 47%(n = 8),and the postoperative morbidity was zero.There was one mediastinal failure found,one patient had local failure at the anastomosis site,and the majority of failures were distant in the lung or bone.The 3-year diseasefree survival and overall survival rates were 41%(n = 7) and 53%(n = 9),respectively.CONCLUSION:The dose escalation through IMRT-SIB in the chemoradiation regimen seems responsible for down-staging the distal esophageal with well-tolerated complications.展开更多
AIM: To study the leakage-penumbra(LP) effect with a proposed correction method for the step-and-shoot intensity modulated radiation therapy(IMRT).METHODS: Leakage-penumbra dose profiles from 10 randomly selected pros...AIM: To study the leakage-penumbra(LP) effect with a proposed correction method for the step-and-shoot intensity modulated radiation therapy(IMRT).METHODS: Leakage-penumbra dose profiles from 10 randomly selected prostate IMRT plans were studied. The IMRT plans were delivered by a Varian 21 EX linear accelerator equipped with a 120-leaf multileaf collimator(MLC). For each treatment plan created by the Pinnacle3 treatment planning system,a 3-dimensional LP dose distribution generated by 5 coplanar photon beams,starting from 0o with equal separation of 72 o,was investigated. For each photon beam used in the stepand-shoot IMRT plans,the first beam segment was set to have the largest area in the MLC leaf-sequencing,and was equal to the planning target volume(PTV). The overshoot effect(OSE) and the segment positional errors were measured using a solid water phantom with Kodak(TL and X-OMAT V) radiographic films. Film dosimetric analysis and calibration were carried out using a film scanner(Vidar VXR-16). The LP dose profiles were determined by eliminating the OSE and segment positional errors with specific individual irradiations. RESULTS: A non-uniformly distributed leaf LP dose ranging from 3% to 5% of the beam dose was measured in clinical IMRT beams. An overdose at the gap between neighboring segments,represented as dose peaks of up to 10% of the total BP,was measured. The LP effect increased the dose to the PTV and surrounding critical tissues. In addition,the effectdepends on the number of beams and segments for each beam. Segment positional error was less than the maximum tolerance of 1 mm under a dose rate of 600 monitor units per minute in the treatment plans. The OSE varying with the dose rate was observed in all photon beams,and the effect increased from 1 to 1.3 Gy per treatment of the rectal intersection. As the dosimetric impacts from the LP effect and OSE may increase the rectal post-radiation effects,a correction of LP was proposed and demonstrated for the central beam profile for one of the planned beams. CONCLUSION: We concluded that the measured dosimetric impact of the LP dose inaccuracy from photon beam segment in step-and-shoot IMRT can be corrected.展开更多
High performance electro-optic modulator,as the key device of integrated ultra-wideband optical systems,have be-come the focus of research.Meanwhile,the organic-based hybrid electro-optic modulators,which make full us...High performance electro-optic modulator,as the key device of integrated ultra-wideband optical systems,have be-come the focus of research.Meanwhile,the organic-based hybrid electro-optic modulators,which make full use of the advant-ages of organic electro-optic(OEO)materials(e.g.high electro-optic coefficient,fast response speed,high bandwidth,easy pro-cessing/integration and low cost)have attracted considerable attention.In this paper,we introduce a series of high-perform-ance OEO materials that exhibit good properties in electro-optic activity and thermal stability.In addition,the recent progress of organic-based hybrid electro-optic devices is reviewed,including photonic crystal-organic hybrid(PCOH),silicon-organic hy-brid(SOH)and plasmonic-organic hybrid(POH)modulators.A high-performance integrated optical platform based on OEO ma-terials is a promising solution for growing high speeds and low power consumption in compact sizes.展开更多
Background:Salvage treatment for locally recurrent nasopharyngeal carcinoma(NPC) is complicated and relatively limited.Radiotherapy,combined with effective concomitant chemotherapy,may improve clinical treatment outco...Background:Salvage treatment for locally recurrent nasopharyngeal carcinoma(NPC) is complicated and relatively limited.Radiotherapy,combined with effective concomitant chemotherapy,may improve clinical treatment outcomes.We conducted a phase Ⅱ randomized controlled trial to evaluate the efficacy of intensity-modulated radiotherapy with concomitant weekly cisplatin on locally recurrent NPC.Methods:Between April 2002 and January 2008,69 patients diagnosed with non-metastatic locally recurrent NPC were randomly assigned to either concomitant chemoradiotherapy group(n = 34) or radiotherapy alone group(n = 35).All patients received intensity-modulated radiotherapy.The radiotherapy dose for both groups was 60 Gy in 27 fractions for 37 days(range 23-53 days).The concomitant chemotherapy schedule was cisplatin 30 mg/m^2 by intravenous infusion weekly during radiotherapy.Results:The median follow-up period of all patients was 35 months(range 2-112 months).Between concomitant chemoradiotherapy and radiotherapy groups,there was only significant difference in the 3-year and 5-year overall survival(OS) rates(68.7%vs.42.2%,P = 0.016 and 41.8%vs.27.5%,P = 0.049,respectively).Subgroup analysis showed that concomitant chemoradiotherapy significantly improved the 5-year OS rate especially for patients in stage rT3-4(33.0%vs.13.2%,P = 0.009),stages Ⅲ-Ⅳ(34.3%vs.13.2%,P = 0.006),recurrence interval >30 months(49.0%vs.20.6%,P = 0.017),and tumor volume >26 cm^3(37.6%vs.0%,P = 0.006).Conclusion:Compared with radiotherapy alone,concomitant chemoradiotherapy can improve OS of the patients with locally recurrent NPC,especially those with advanced T category(rT3-4) and stage(lll-IV) diseases,recurrence intervals >30 months,and tumor volume >26 cm^3.展开更多
Background: The prognostic values of staging parameters require continual re?assessment amid changes in diag?nostic and therapeutic methods. This study aimed to identify the prognostic factors and failure patterns of ...Background: The prognostic values of staging parameters require continual re?assessment amid changes in diag?nostic and therapeutic methods. This study aimed to identify the prognostic factors and failure patterns of non?meta?static nasopharyngeal carcinoma(NPC) in the intensity?modulated radiotherapy(IMRT) era.Methods: We reviewed the data from 749 patients with newly diagnosed, biopsy?proven, non?metastatic NPC in our cancer center(South China, an NPC endemic area) between January 2003 and December 2007. All patients under?went magnetic resonance imaging(MRI) before receiving IMRT. The actuarial survival rates were estimated using the Kaplan–Meier method, and survival curves were compared using the log?rank test. Multivariate analyses with the Cox proportional hazards model were used to test for the independent prognostic factors by backward eliminating insigniicant explanatory variables.Results: The 5?year occurrence rates of local failure, regional failure, locoregional failure, and distant failure were 5.4, 3.0, 7.4, and 17.4%, respectively. The 5?year survival rates were as follows: local relapse?free survival, 94.6%; nodal relapse?free survival, 97.0%; distant metastasis?free survival, 82.6%; disease?free survival, 75.1%; and overall survival, 82.0%. Multivariate Cox regression analysis revealed that orbit involvement was the only signiicant prognostic fac?tor for local failure(P = 0.011). Parapharyngeal tumor extension, retropharyngeal lymph node involvement, and the laterality, longest diameter, and Ho's location of the cervical lymph nodes were signiicant prognostic factors for both distant failure and disease failure(all P < 0.05). Intracranial extension had signiicant prognostic value for distant failure(P = 0.040).Conclusions: The key failure pattern for NPC was distant metastasis in the IMRT era. With changes in diagnostic and therapeutic technologies as well as treatment modalities, the signiicant prognostic parameters for local control have also been altered substantially.展开更多
基金supported by Program for New Century Excellent Talents in University(No.NCET-06-0925)
文摘The modulation depth, defined according to practical modulation results, which changes with the microwave power and its frequency, is significant for systems utilizing the frequency-shift characteristic of the LiNbO3 waveguide Electro-Optic Intensity Modulator (EOIM). By analyzing the impedance mismatch between the microwave source and the EOIM, the effective voltage applied to the RF port of the EOIM is deprived from the microwave power and its frequency. Associating with analyses of the phase velocity mismatch between the microwave and the optical wave, the theoretical modulation depth has been obtained, which is verified by experimental results. We provide a method to choose the appropriate modulation depth to optimize the desired sideband through proper transmission bias for the system based on the frequency-shift characteristic of the EOIM.
基金supported by Program for New Century Excellent Talents in University under Grand No. NCET-06-0925.
文摘High-speed and wide-band LiNbO3 waveguide electro-optic intensity modulator has drawn great attention in the field of optical fiber communication and sensor. This paper reports the research results on the measurement of frequency shift characteristics of Mach-Zehnder electro-optic intensity modulator. Two measurement methods of frequency shift characteristics for high and low frequency modulations are studied in theory and experiment and demonstrate different results. The realization of a multi-wavelength optical source based on Mach-Zehnder electro-optic intensity modulator has been introduced. The technique to reach the maximum intensity for interesting shift frequency, particularly for heterodyne detection of Brillouin distributed optical fiber sensing, has been given.
基金Supported by the Joint Research Fund in Astronomy under Cooperative Agreement between the National Natural Science Foundation of China and Chinese Academy of Sciences under Grant No U1531102the Fundamental Research Funds for the Central Universities under Grant No HEUCF181116the National Natural Science Foundation of China under Grant Nos61107059,61077047 and 11264001
文摘We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are theoretically and experimentally analyzed and investigated. Both the electric and magnetic fields can manipulate the molecular arrangement of LC to array a certain angle without changing the refractive index of the LC. Therefore, light loss in the PCF varies with the electric and magnetic fields whereas the peak wavelengths remain constant. The experimental results show that the transmission intensity decreases with the increase of the electric and magnetic fields. The cut-off electric field is 0.899 V/um at 20 Hz and the cut-off magnetic field is 195 m T. This simple and compacted optical modulator will have a great prospect in sensing applications.
基金supported by the National Key R&D Plan(No.2016YFA0401900)
文摘A bunch arrival-time monitor(BAM) based on an electro-optical intensity modulation scheme is currently under development at Shanghai Soft X-ray Free-Electron Laser to meet the high-resolution requirements for bunch stability. The BAM uses a radio frequency signal generated by a pickup cavity to modulate the reference laser pulses in an electro-optical intensity modulator(EOM), and the bunch arrival-time information is derived from the amplitude change of the laser pulse after laser pulse modulation.EOM is a key optical component in the BAM system.Through the basic principle analysis of BAM, many parameters of the EOM are observed to affect the measurement resolution of the BAM system. Therefore, a systematic analysis of the EOM is crucial. In this paper, we present two schemes to compare and analyze an EOM and provide a reference for selecting a new version of the EOM.
基金Project supported by the State Key Program of National Natural Science of China (Grant No 60438010)
文摘This paper demonstrates the intensity modulation characters of orthogonally polarized HeNe lasers with different optical feedback level generated by the variable reflectivity of external reflector. The modulation depths of the orthogonally polarized frequencies are increased when the optical feedback level becomes strong. It also observes that the modulation amplitudes are different for different external cavity length. Based on the vectorial extension of Lamb's semi-classical theory, it finds that the calculations are consistent with the experimental results.
文摘Objective: Juvenile Nasopharyngeal Angiofibroma (JNA) is a benign neoplasm with a high vascularity component, greater craniofacial involvement in adolescent patients, and aggressive local behaviour. In unresectable patients, radiotherapy is a therapeutic option for local control. Our aim in this study was to analyze the clinical benefit and local control provided by two modalities of radiotherapy: the Three-Dimensional Conformal (3DC) technique and volumetric modulated arc therapy (VMAT), applied to pediatric patients with JNA considered unresectable and non-recurrent. Methods: In retrospective study, the information was recorded from pediatric patients with a diagnosis of non-recurrent and unresectable JNA treated with radiotherapy at the Oncology Hospital of the National Medical Center SXXI of Mexico City, from March 2010 to March 2021. Radiotherapy management and its association with clinical outcomes of tumour control, and symptoms were assessed. In addition, an evaluation of acute and chronic toxicity was performed. Results: It was found that the median age was 14 years. 9 patients (37.5%) underwent 3DC and 15 (62.5%) VMAT. In terms of local control, and progression-free survival, we did not find significant difference between radiotherapy modalities (p ≤ 0.57). Acute toxicity for both modalities presented statistical differences for radio epithelitis (p = 0.03). Only Grade I and II radiation-induced acute toxicity was observed. Regarding chronic toxicity, statistical significance was observed for craniofacial hypoplasia, in relation to its absence in the VMAT group (p = 0.001). Conclusion: The VMAT presents improvements in dosimetry parameters that improve patient toxicity. In both techniques adequate tumour control was observed, however, the rarity of the disease is a limitation to establish the most appropriate therapeutic technique.
文摘The characteristics of a conventional LiNbO3 intensity modulator made up of a Mach-Zehnder(MZ) type annealed proton exchange(APE) waveguide and coplanar waveguide(CPW) modulation electrode are presented. The APE waveguide characteristics and their relations with process parameters are analyzed. At the same time, the electrical characteristics of modulation electrode, such as modulation voltage, microwave effective index associated with modulation bandwidth, characteristics impedance, are also investigated in detail.
基金Project supported by the Scientific Research Program of Hunan Provincial Education Department,China(Grant No.18C0232)the International Cooperative Extension Program of Changsha University of Science and Technology,China(Grant No.2019IC35)
文摘The novel BaTiO3/BiFeO3/TiO2 multilayer heterojunction is prepared on a fluorine-doped tinoxide(FTO) substrate by the sol–gel method. The results indicate that the Pt/Ba TiO3/BiFeO3/TiO2/FTO heterojunction exhibits stable bipolar resistive switching characteristic, good retention performance, and reversal characteristic. Under different pulse voltages and light fields, four stable resistance states can also be realized. The analysis shows that the main conduction mechanism of the resistive switching characteristic of the heterojunction is space charge limited current(SCLC) effect. After the comprehensive analysis of the band diagram and the P–E ferroelectric property of the multilayer heterojunction, we can deduce that the SCLC is formed by the effect of the oxygen vacancy which is controlled by ferroelectric polarizationmodulated change of interfacial barrier. And the effective photo-generated carrier also plays a regulatory role in resistance state(RS), which is formed by the double ferroelectric layer Ba TiO3/BiFeO3 under different light fields. This research is of potential application values for developing the multi-state non-volatile resistance random access memory(RRAM) devices based on ferroelectric materials.
文摘The effect on intensity correlation time T by input signal is studied for gain-noise model of a single-mode laser driven by colored pump noise and colored quantum noise with colored cross-correlation with a bias signal modulation in this paper. By using the linear approximation method, we detect that there exists maximum (i.e., resonance) in the curve of the intensity correlation time T upon bias current io when the noise correlation coefficient λ is positive; and there exists minimum (i.e., suppression) in the T-io curve when λ is negative. And whenλ is zero, T increases monotonously with increasing io. Furthermore, the curve of T upon the signal frequency Ω is also studied. Our study shows that no matter what the value of λ is, there exists minimum (i.e., suppression) in the T-Ω curve.
基金Project supported by the National Natural Science Foundation of China(Grant No.61605034)
文摘Using a pump with a multi-line spectrum to broaden the Brillouin gain bandwidth is an effective way to achieve lowdistortion amplification with high gain. Here, we theoretically and experimentally investigate the generation of a broadband Brillouin gain spectrum based on multi-frequency intensity modulation in an optical fiber. The arbitrary bandwidth of the Brillouin gain spectrum of stimulated Brillouin scattering(SBS) can be obtained as expected. In our experiment, a broadband Brillouin gain spectrum with a bandwidth of about 200 MHz is demonstrated. We also achieve a low-distortion amplification of a weak signal, whose maximum magnification is 65 d B for a-68-dBm input power signal.
文摘By using the linear approximation method, the intensity correlation function is calculated for a single-mode laser modulated by a bias signal and driven by colored pump and quantum noises with colored cross-correlation. We found that, when the correlation time between the two noises is very short, the behavior of the intensity correlation function versus the time, in addition to decreasing monotonously, also exhibits several cases, such as one maximum, one minimum, and two extrema. When the correlation time between the two noises is very long, the behavior of the intensity correlation function exhibits oscillation and the envelope is similar to the case of short cross-correlation time.
文摘We propose and analyze a novel Si-based electro-optic modulator with an improved metal-oxide-semiconductor (MOS) capacitor configuration integrated into silicon-on-insulator (SOl). Three gate-oxide layers embedded in the silicon waveguide constitute a triple MOS capacitor structure, which boosts the modulation efficiency compared with a single MOS capacitor. The simulation results demonstrate that the Vπ Lπ product is 2. 4V · cm. The rise time and fall time of the proposed device are calculated to be 80 and 40ps from the transient response curve, respectively,indicating a bandwidth of 8GHz. The phase shift efficiency and bandwidth can be enhanced by rib width scaling.
文摘A Mach-Zehnder(MZ) electro-optic(EO) modulator are real iz ed,with three optical layers as polymer materials.The functional layer is the co rona poled crosslinkable polyurethane.The ridge waveguide is fabricated by using the spin-coating,poling,photolithography and oxygen reactive ion etching(RIE) techniques.The mode and the modulation properties of these devices are demonstra ted in a micron control system,while the light source works at the wavelength of 1 31 or 1 55 micron.
文摘Although many studies have investigated intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC),sample sizes in the reported studies are usually small and different in outcomes in different T and N subgroups are seldom analyzed.Herein,we evaluated the outcomes of NPC patients treated with IMRT and further explored treatment strategy to improve such outcome.We collected clinical data of 865 NPC patients treated with IMRT alone or in combination with chemotherapy,and classified all cases into the following prognostic categories according to different TNM stages:early stage group (T1-2N0-1M0),advanced local disease group (T3-4N0-1M0),advanced nodal disease group (T1-2N2-3M0),and advanced locoregional disease group (T3-4N2-3M0).The 5-year overall survival (OS),local relapse-free survival (LRFS),and distant metastases-free survival (DMFS) were 83.0%,90.4%,and 84.0%,respectively.The early disease group had the lowest treatment failure rate,with a 5-year OS of 95.6%.The advanced local disease group and advanced nodal disease group had similar failure pattern and treatment outcomes as well as similar hazard ratios for death (4.230 and 4.625,respectively).The advanced locoregional disease group had the highest incidence of relapse and death,with a 5-year DMFS and OS of 62.3% and 62.2%,respectively,and a hazard ratio for death of 10.402.Comparing with IMRT alone,IMRT in combination with chemotherapy provided no significant benefit to locoregionally advanced NPC.Our results suggest that the decision of treatment strategy for NPC patients should consider combinations of T and N stages,and that IMRT alone for early stage NPC patients can produce satisfactory results.However,for advanced local,nodal,and locoregional disease groups,a combination of chemotherapy and radiotherapy is recommended.
文摘Aims: The EORTC-NCI study investigating the addition of temozolomide trial to standard radiation therapy has demonstrated improved duration of survival in patients with Glioblastoma multiforme (GBM). With longer survival duration, there is the potential for latent RT morbidity, not previously seen in historical patients. This study evaluates the potential dosimetric advantages of utilising IMRT over 3D-conformal RT in such patients. Methods: 10 consecutive patients with GBM formally screened for a clinical study over a two-month period were planned and treated with IMRT utilising daily on-board imaging (OBI). The EORTC protocol dosimetric criteria and constraints were used in target delineation and planning. For each patient, a 3DCRT plan was also produced. Endpoints for dosimetric evaluation analysed related to tumour dose: mean PTV60 dose (mPTV60Dose), Conformity Index (CI);and normal tissue dose: mean normal brain dose (mBrainDose) and V40 Brain (Brainv40). IGRT endpoints were the median isocentre shifts required in 3 axes measured in one direction. The variation between the IMRT and 3DCRT dosimetric endpoints was examined using Wilcoxon analysis. Results: The 10 patients had tumours located in temporal (3), parietal (3), occipital (2) and callosal (2) regions. The median PTV and normal brain volumes were 308.1 cm3 and 1077.5 cm3 respectively. The IMRT dosimetry was significantly improved in all endpoints specifically CI (p = 0.002), mPTV60Dose (p = 0.004), mBrainDose (p = 0.002) and Brainv40 (p = 0.019). OBI directed isocentre measurements in the patient group were available for 230 treatments. The median shifts (and 95% C.I.s) were 0.1 cm vertical (0.1 - 0.2), 0.1 cm longitudinal (0.1 - 0.2) and 0.2 cm lateral (0.2 - 0.2). At a minimum follow-up of 2 years’ post diagnosis, the median survival of the group is 18.0 months (95% CI: 13.4 - 22.6 months). Conclusion: IMRT for GBM produces significant dosimetric advantages in relation to planning target volume and normal tissue dose compared with 3D conformal plans. The data also confirm the accuracy of IMRT technique for CNS with IGRT delivery utilising OBI demonstrating minimal deviation from planned to treated isocentre.
文摘AIM:To evaluate impact of radiation therapy dose escalation through intensity modulated radiation therapy with simultaneous integrated boost(IMRT-SIB).METHODS:We retrospectively reviewed the patients who underwent four-dimensional-based IMRT-SIBbased neoadjuvant chemoradiation protocol.During the concurrent chemoradiation therapy,radiation therapy was through IMRT-SIB delivered in 28 consecutive daily fractions with total radiation doses of 56 Gy to tumor and 5040 Gy dose-painted to clinical tumor volume,with a regimen at the discretion of the treating medical oncologist.This was followed by surgical tumor resection.We analyzed pathological completion response(p CR) rates its relationship with overall survival and event-freesurvival.RESULTS:Seventeen patients underwent dose escalation with the IMRT-SIB protocol between 2007 and 2014 and their records were available for analysis.Among the IMRT-SIB-treated patients,the toxicity appeared mild,the most common side effects were grade 1-3 esophagitis(46%) and pneumonitis(11.7%).There were no cardiac events.The Ro resection rate was 94%(n = 16),the p CR rate was 47%(n = 8),and the postoperative morbidity was zero.There was one mediastinal failure found,one patient had local failure at the anastomosis site,and the majority of failures were distant in the lung or bone.The 3-year diseasefree survival and overall survival rates were 41%(n = 7) and 53%(n = 9),respectively.CONCLUSION:The dose escalation through IMRT-SIB in the chemoradiation regimen seems responsible for down-staging the distal esophageal with well-tolerated complications.
基金supported by the Medical Physics Department of GRRCC,Kitchener,Ontario
文摘AIM: To study the leakage-penumbra(LP) effect with a proposed correction method for the step-and-shoot intensity modulated radiation therapy(IMRT).METHODS: Leakage-penumbra dose profiles from 10 randomly selected prostate IMRT plans were studied. The IMRT plans were delivered by a Varian 21 EX linear accelerator equipped with a 120-leaf multileaf collimator(MLC). For each treatment plan created by the Pinnacle3 treatment planning system,a 3-dimensional LP dose distribution generated by 5 coplanar photon beams,starting from 0o with equal separation of 72 o,was investigated. For each photon beam used in the stepand-shoot IMRT plans,the first beam segment was set to have the largest area in the MLC leaf-sequencing,and was equal to the planning target volume(PTV). The overshoot effect(OSE) and the segment positional errors were measured using a solid water phantom with Kodak(TL and X-OMAT V) radiographic films. Film dosimetric analysis and calibration were carried out using a film scanner(Vidar VXR-16). The LP dose profiles were determined by eliminating the OSE and segment positional errors with specific individual irradiations. RESULTS: A non-uniformly distributed leaf LP dose ranging from 3% to 5% of the beam dose was measured in clinical IMRT beams. An overdose at the gap between neighboring segments,represented as dose peaks of up to 10% of the total BP,was measured. The LP effect increased the dose to the PTV and surrounding critical tissues. In addition,the effectdepends on the number of beams and segments for each beam. Segment positional error was less than the maximum tolerance of 1 mm under a dose rate of 600 monitor units per minute in the treatment plans. The OSE varying with the dose rate was observed in all photon beams,and the effect increased from 1 to 1.3 Gy per treatment of the rectal intersection. As the dosimetric impacts from the LP effect and OSE may increase the rectal post-radiation effects,a correction of LP was proposed and demonstrated for the central beam profile for one of the planned beams. CONCLUSION: We concluded that the measured dosimetric impact of the LP dose inaccuracy from photon beam segment in step-and-shoot IMRT can be corrected.
基金the National Natural Science Foundation of China(No.62175267)the Beijing Municipal Natural Science Foundation(No.4192061)+1 种基金the Fundamental Research Funds for the Central Universities(2020MDJC13)the Beijing Talents Foundation(2018000021223ZK45)for the financial support.
文摘High performance electro-optic modulator,as the key device of integrated ultra-wideband optical systems,have be-come the focus of research.Meanwhile,the organic-based hybrid electro-optic modulators,which make full use of the advant-ages of organic electro-optic(OEO)materials(e.g.high electro-optic coefficient,fast response speed,high bandwidth,easy pro-cessing/integration and low cost)have attracted considerable attention.In this paper,we introduce a series of high-perform-ance OEO materials that exhibit good properties in electro-optic activity and thermal stability.In addition,the recent progress of organic-based hybrid electro-optic devices is reviewed,including photonic crystal-organic hybrid(PCOH),silicon-organic hy-brid(SOH)and plasmonic-organic hybrid(POH)modulators.A high-performance integrated optical platform based on OEO ma-terials is a promising solution for growing high speeds and low power consumption in compact sizes.
文摘Background:Salvage treatment for locally recurrent nasopharyngeal carcinoma(NPC) is complicated and relatively limited.Radiotherapy,combined with effective concomitant chemotherapy,may improve clinical treatment outcomes.We conducted a phase Ⅱ randomized controlled trial to evaluate the efficacy of intensity-modulated radiotherapy with concomitant weekly cisplatin on locally recurrent NPC.Methods:Between April 2002 and January 2008,69 patients diagnosed with non-metastatic locally recurrent NPC were randomly assigned to either concomitant chemoradiotherapy group(n = 34) or radiotherapy alone group(n = 35).All patients received intensity-modulated radiotherapy.The radiotherapy dose for both groups was 60 Gy in 27 fractions for 37 days(range 23-53 days).The concomitant chemotherapy schedule was cisplatin 30 mg/m^2 by intravenous infusion weekly during radiotherapy.Results:The median follow-up period of all patients was 35 months(range 2-112 months).Between concomitant chemoradiotherapy and radiotherapy groups,there was only significant difference in the 3-year and 5-year overall survival(OS) rates(68.7%vs.42.2%,P = 0.016 and 41.8%vs.27.5%,P = 0.049,respectively).Subgroup analysis showed that concomitant chemoradiotherapy significantly improved the 5-year OS rate especially for patients in stage rT3-4(33.0%vs.13.2%,P = 0.009),stages Ⅲ-Ⅳ(34.3%vs.13.2%,P = 0.006),recurrence interval >30 months(49.0%vs.20.6%,P = 0.017),and tumor volume >26 cm^3(37.6%vs.0%,P = 0.006).Conclusion:Compared with radiotherapy alone,concomitant chemoradiotherapy can improve OS of the patients with locally recurrent NPC,especially those with advanced T category(rT3-4) and stage(lll-IV) diseases,recurrence intervals >30 months,and tumor volume >26 cm^3.
基金supported by grants from the Key Laboratory Construction Project of Guangzhou City,China (121800085)the Health & Medical Collaborative Innovation Project of Guangzhou City,China (201400000001)+2 种基金the National Science & Technology Pillar Program during the Twelfth Five-year Plan Period (2014BAI09B10)the National Natural Science Foundation of China (81201746)the Planned Science and Technology Project of Guangdong Province,China (2013B020400004)
文摘Background: The prognostic values of staging parameters require continual re?assessment amid changes in diag?nostic and therapeutic methods. This study aimed to identify the prognostic factors and failure patterns of non?meta?static nasopharyngeal carcinoma(NPC) in the intensity?modulated radiotherapy(IMRT) era.Methods: We reviewed the data from 749 patients with newly diagnosed, biopsy?proven, non?metastatic NPC in our cancer center(South China, an NPC endemic area) between January 2003 and December 2007. All patients under?went magnetic resonance imaging(MRI) before receiving IMRT. The actuarial survival rates were estimated using the Kaplan–Meier method, and survival curves were compared using the log?rank test. Multivariate analyses with the Cox proportional hazards model were used to test for the independent prognostic factors by backward eliminating insigniicant explanatory variables.Results: The 5?year occurrence rates of local failure, regional failure, locoregional failure, and distant failure were 5.4, 3.0, 7.4, and 17.4%, respectively. The 5?year survival rates were as follows: local relapse?free survival, 94.6%; nodal relapse?free survival, 97.0%; distant metastasis?free survival, 82.6%; disease?free survival, 75.1%; and overall survival, 82.0%. Multivariate Cox regression analysis revealed that orbit involvement was the only signiicant prognostic fac?tor for local failure(P = 0.011). Parapharyngeal tumor extension, retropharyngeal lymph node involvement, and the laterality, longest diameter, and Ho's location of the cervical lymph nodes were signiicant prognostic factors for both distant failure and disease failure(all P < 0.05). Intracranial extension had signiicant prognostic value for distant failure(P = 0.040).Conclusions: The key failure pattern for NPC was distant metastasis in the IMRT era. With changes in diagnostic and therapeutic technologies as well as treatment modalities, the signiicant prognostic parameters for local control have also been altered substantially.