期刊文献+
共找到4,545篇文章
< 1 2 228 >
每页显示 20 50 100
Modulation Depth Based on Frequency-shift Characteristic of LiNbO3 Waveguide Electro-optic Intensity Modulator
1
作者 周会娟 孟洲 廖毅 《Journal of Measurement Science and Instrumentation》 CAS 2010年第2期125-128,共4页
The modulation depth, defined according to practical modulation results, which changes with the microwave power and its frequency, is significant for systems utilizing the frequency-shift characteristic of the LiNbO3 ... The modulation depth, defined according to practical modulation results, which changes with the microwave power and its frequency, is significant for systems utilizing the frequency-shift characteristic of the LiNbO3 waveguide Electro-Optic Intensity Modulator (EOIM). By analyzing the impedance mismatch between the microwave source and the EOIM, the effective voltage applied to the RF port of the EOIM is deprived from the microwave power and its frequency. Associating with analyses of the phase velocity mismatch between the microwave and the optical wave, the theoretical modulation depth has been obtained, which is verified by experimental results. We provide a method to choose the appropriate modulation depth to optimize the desired sideband through proper transmission bias for the system based on the frequency-shift characteristic of the EOIM. 展开更多
关键词 waveguide electro-optic intensity modulator modulation depth frequency shift distributedBriiouin optical fiber sensing
下载PDF
Measurement of Frequency Shift Characteristics Based on LiNbO_3 Waveguide Electro-Optic Intensity Modulator 被引量:1
2
作者 Zhou Meng Hui-Juan Zhou Yi Liao Qiong Yao 《Journal of Electronic Science and Technology of China》 2008年第4期449-452,共4页
High-speed and wide-band LiNbO3 waveguide electro-optic intensity modulator has drawn great attention in the field of optical fiber communication and sensor. This paper reports the research results on the measurement ... High-speed and wide-band LiNbO3 waveguide electro-optic intensity modulator has drawn great attention in the field of optical fiber communication and sensor. This paper reports the research results on the measurement of frequency shift characteristics of Mach-Zehnder electro-optic intensity modulator. Two measurement methods of frequency shift characteristics for high and low frequency modulations are studied in theory and experiment and demonstrate different results. The realization of a multi-wavelength optical source based on Mach-Zehnder electro-optic intensity modulator has been introduced. The technique to reach the maximum intensity for interesting shift frequency, particularly for heterodyne detection of Brillouin distributed optical fiber sensing, has been given. 展开更多
关键词 BRILLOUIN electro-optic intensity modulator frequency shift LiNbO3.
下载PDF
Magneto and Electro-Optic Intensity Modulator Based on Liquid Crystal and Magnetic Fluid Filled Photonic Crystal Fiber
3
作者 Yue-Lan Lu Fei-Ru Wang +4 位作者 Chi Zhang ai-Wen Yin Yu Huang Wei-min Sun Yong-Jun Liu 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第10期36-39,共4页
We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are th... We propose a novel light intensity modulator based on magnetic fluid and liquid crystal(LC) filled photonic crystal fibers(PCFs). The influences of electric and magnetic fields on the transmission intensity are theoretically and experimentally analyzed and investigated. Both the electric and magnetic fields can manipulate the molecular arrangement of LC to array a certain angle without changing the refractive index of the LC. Therefore, light loss in the PCF varies with the electric and magnetic fields whereas the peak wavelengths remain constant. The experimental results show that the transmission intensity decreases with the increase of the electric and magnetic fields. The cut-off electric field is 0.899 V/um at 20 Hz and the cut-off magnetic field is 195 m T. This simple and compacted optical modulator will have a great prospect in sensing applications. 展开更多
关键词 PCF LC Magneto and electro-optic intensity modulator Based on Liquid Crystal and Magnetic Fluid Filled Photonic Crystal Fiber
下载PDF
Analysis of electro-optical intensity modulator for bunch arrival-time monitor at SXFEL
4
作者 Jin-Guo Wang Xiao-Qing Liu +3 位作者 Lie Feng Wen-Yan Zhang Xing-Tao Wang Bo Liu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第1期1-9,共9页
A bunch arrival-time monitor(BAM) based on an electro-optical intensity modulation scheme is currently under development at Shanghai Soft X-ray Free-Electron Laser to meet the high-resolution requirements for bunch st... A bunch arrival-time monitor(BAM) based on an electro-optical intensity modulation scheme is currently under development at Shanghai Soft X-ray Free-Electron Laser to meet the high-resolution requirements for bunch stability. The BAM uses a radio frequency signal generated by a pickup cavity to modulate the reference laser pulses in an electro-optical intensity modulator(EOM), and the bunch arrival-time information is derived from the amplitude change of the laser pulse after laser pulse modulation.EOM is a key optical component in the BAM system.Through the basic principle analysis of BAM, many parameters of the EOM are observed to affect the measurement resolution of the BAM system. Therefore, a systematic analysis of the EOM is crucial. In this paper, we present two schemes to compare and analyze an EOM and provide a reference for selecting a new version of the EOM. 展开更多
关键词 BUNCH arrival-time MONITOR (BAM) Soft X-ray Free-Electron Laser (SXFEL) High resolution electro-opticAL intensity modulator (EOM)
下载PDF
Intensity modulation characters of orthogonally polarized HeNe lasers with different optical feedback level 被引量:2
5
作者 崔柳 张书练 万新军 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第2期644-648,共5页
This paper demonstrates the intensity modulation characters of orthogonally polarized HeNe lasers with different optical feedback level generated by the variable reflectivity of external reflector. The modulation dept... This paper demonstrates the intensity modulation characters of orthogonally polarized HeNe lasers with different optical feedback level generated by the variable reflectivity of external reflector. The modulation depths of the orthogonally polarized frequencies are increased when the optical feedback level becomes strong. It also observes that the modulation amplitudes are different for different external cavity length. Based on the vectorial extension of Lamb's semi-classical theory, it finds that the calculations are consistent with the experimental results. 展开更多
关键词 intensity modulation optical feedback frequency split
下载PDF
Three-Dimensional Conformal and Intensity Modulated Dynamic Radiotherapy in Juvenile Nasopharyngeal Angiofibroma
6
作者 María Fátima Chilaca Rosas David Rafael Salazar Calderon +6 位作者 Manuel Tadeo Contreras Aguilar Carlos Eduardo Barrios Merino Melissa García Lezama Benjamín Conde Castro Shelley Astrid Martínez Torres Katia Hernández Salgado Rafael Medrano Guzmán 《International Journal of Otolaryngology and Head & Neck Surgery》 2023年第4期269-278,共10页
Objective: Juvenile Nasopharyngeal Angiofibroma (JNA) is a benign neoplasm with a high vascularity component, greater craniofacial involvement in adolescent patients, and aggressive local behaviour. In unresectable pa... Objective: Juvenile Nasopharyngeal Angiofibroma (JNA) is a benign neoplasm with a high vascularity component, greater craniofacial involvement in adolescent patients, and aggressive local behaviour. In unresectable patients, radiotherapy is a therapeutic option for local control. Our aim in this study was to analyze the clinical benefit and local control provided by two modalities of radiotherapy: the Three-Dimensional Conformal (3DC) technique and volumetric modulated arc therapy (VMAT), applied to pediatric patients with JNA considered unresectable and non-recurrent. Methods: In retrospective study, the information was recorded from pediatric patients with a diagnosis of non-recurrent and unresectable JNA treated with radiotherapy at the Oncology Hospital of the National Medical Center SXXI of Mexico City, from March 2010 to March 2021. Radiotherapy management and its association with clinical outcomes of tumour control, and symptoms were assessed. In addition, an evaluation of acute and chronic toxicity was performed. Results: It was found that the median age was 14 years. 9 patients (37.5%) underwent 3DC and 15 (62.5%) VMAT. In terms of local control, and progression-free survival, we did not find significant difference between radiotherapy modalities (p ≤ 0.57). Acute toxicity for both modalities presented statistical differences for radio epithelitis (p = 0.03). Only Grade I and II radiation-induced acute toxicity was observed. Regarding chronic toxicity, statistical significance was observed for craniofacial hypoplasia, in relation to its absence in the VMAT group (p = 0.001). Conclusion: The VMAT presents improvements in dosimetry parameters that improve patient toxicity. In both techniques adequate tumour control was observed, however, the rarity of the disease is a limitation to establish the most appropriate therapeutic technique. 展开更多
关键词 intensity-modulated Radiotherapy Nasopharyngeal Angiofibroma PEDIATRIC RADIOTHERAPY TOXICITY
下载PDF
Mach-Zehnder Type Annealed Proton Exchange Waveguide and Coplanar Waveguide Modulation Electrode LiNbO_3 Intensity Modulator 被引量:2
7
作者 HE Jian ZHU Xue-jun 《Semiconductor Photonics and Technology》 CAS 2007年第1期69-75,共7页
The characteristics of a conventional LiNbO3 intensity modulator made up of a Mach-Zehnder(MZ) type annealed proton exchange(APE) waveguide and coplanar waveguide(CPW) modulation electrode are presented. The APE waveg... The characteristics of a conventional LiNbO3 intensity modulator made up of a Mach-Zehnder(MZ) type annealed proton exchange(APE) waveguide and coplanar waveguide(CPW) modulation electrode are presented. The APE waveguide characteristics and their relations with process parameters are analyzed. At the same time, the electrical characteristics of modulation electrode, such as modulation voltage, microwave effective index associated with modulation bandwidth, characteristics impedance, are also investigated in detail. 展开更多
关键词 intensity modulator APE waveguide CPW
下载PDF
Electro-optical dual modulation on resistive switching behavior in BaTiO3/BiFeO3/TiO2 heterojunction 被引量:1
8
作者 Jia-Jia Zhao Jin-Shuai Zhang +4 位作者 Feng Zhang Wei Wang Hai-Rong He Wang-Yang Cai Jin Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第12期292-297,共6页
The novel BaTiO3/BiFeO3/TiO2 multilayer heterojunction is prepared on a fluorine-doped tinoxide(FTO) substrate by the sol–gel method. The results indicate that the Pt/Ba TiO3/BiFeO3/TiO2/FTO heterojunction exhibits s... The novel BaTiO3/BiFeO3/TiO2 multilayer heterojunction is prepared on a fluorine-doped tinoxide(FTO) substrate by the sol–gel method. The results indicate that the Pt/Ba TiO3/BiFeO3/TiO2/FTO heterojunction exhibits stable bipolar resistive switching characteristic, good retention performance, and reversal characteristic. Under different pulse voltages and light fields, four stable resistance states can also be realized. The analysis shows that the main conduction mechanism of the resistive switching characteristic of the heterojunction is space charge limited current(SCLC) effect. After the comprehensive analysis of the band diagram and the P–E ferroelectric property of the multilayer heterojunction, we can deduce that the SCLC is formed by the effect of the oxygen vacancy which is controlled by ferroelectric polarizationmodulated change of interfacial barrier. And the effective photo-generated carrier also plays a regulatory role in resistance state(RS), which is formed by the double ferroelectric layer Ba TiO3/BiFeO3 under different light fields. This research is of potential application values for developing the multi-state non-volatile resistance random access memory(RRAM) devices based on ferroelectric materials. 展开更多
关键词 ferroelectric multilayer heterojunction resistive switching characteristic electro-optical dual modulation multi-state resistance
下载PDF
Effect on Intensity Correlation Time by Input Signal in a Single-Mode Laser with Bias Signal Modulation 被引量:1
9
作者 CHEN Li-Mei CAO Li +1 位作者 WU Da-Jin GE Guo-Qin 《Communications in Theoretical Physics》 SCIE CAS CSCD 2005年第4X期638-642,共5页
The effect on intensity correlation time T by input signal is studied for gain-noise model of a single-mode laser driven by colored pump noise and colored quantum noise with colored cross-correlation with a bias signa... The effect on intensity correlation time T by input signal is studied for gain-noise model of a single-mode laser driven by colored pump noise and colored quantum noise with colored cross-correlation with a bias signal modulation in this paper. By using the linear approximation method, we detect that there exists maximum (i.e., resonance) in the curve of the intensity correlation time T upon bias current io when the noise correlation coefficient λ is positive; and there exists minimum (i.e., suppression) in the T-io curve when λ is negative. And whenλ is zero, T increases monotonously with increasing io. Furthermore, the curve of T upon the signal frequency Ω is also studied. Our study shows that no matter what the value of λ is, there exists minimum (i.e., suppression) in the T-Ω curve. 展开更多
关键词 intensity correlation time bias signal modulation linear approximation method
下载PDF
High-gain and low-distortion Brillouin amplification based on pump multi-frequency intensity modulation
10
作者 Li-Wen Sheng De-Xin Ba Zhi-Wei Lv 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第2期277-282,共6页
Using a pump with a multi-line spectrum to broaden the Brillouin gain bandwidth is an effective way to achieve lowdistortion amplification with high gain. Here, we theoretically and experimentally investigate the gene... Using a pump with a multi-line spectrum to broaden the Brillouin gain bandwidth is an effective way to achieve lowdistortion amplification with high gain. Here, we theoretically and experimentally investigate the generation of a broadband Brillouin gain spectrum based on multi-frequency intensity modulation in an optical fiber. The arbitrary bandwidth of the Brillouin gain spectrum of stimulated Brillouin scattering(SBS) can be obtained as expected. In our experiment, a broadband Brillouin gain spectrum with a bandwidth of about 200 MHz is demonstrated. We also achieve a low-distortion amplification of a weak signal, whose maximum magnification is 65 d B for a-68-dBm input power signal. 展开更多
关键词 BRILLOUIN gain spectrum bandwidth intensity modulation LOW DISTORTION AMPLIFICATION
下载PDF
Intensity Correlation Function of a Single-Mode Laser Driven by Colored Cross-Correlation Noises in Modulation of a Bias Signal
11
作者 HANLi-Bo CAOLi +1 位作者 YANGHong-Quan WUDa-Jin 《Communications in Theoretical Physics》 SCIE CAS CSCD 2005年第4期666-670,共5页
By using the linear approximation method, the intensity correlation function is calculated for a single-mode laser modulated by a bias signal and driven by colored pump and quantum noises with colored cross-correlatio... By using the linear approximation method, the intensity correlation function is calculated for a single-mode laser modulated by a bias signal and driven by colored pump and quantum noises with colored cross-correlation. We found that, when the correlation time between the two noises is very short, the behavior of the intensity correlation function versus the time, in addition to decreasing monotonously, also exhibits several cases, such as one maximum, one minimum, and two extrema. When the correlation time between the two noises is very long, the behavior of the intensity correlation function exhibits oscillation and the envelope is similar to the case of short cross-correlation time. 展开更多
关键词 linear approximation method intensity correlation function bias signal modulation oscillation
下载PDF
A High-Performance Silicon Electro-Optic Phase Modulator with a Triple MOS Capacitor 被引量:2
12
作者 黄北举 陈弘达 +2 位作者 刘金彬 顾明 刘海军 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2006年第12期2089-2093,共5页
We propose and analyze a novel Si-based electro-optic modulator with an improved metal-oxide-semiconductor (MOS) capacitor configuration integrated into silicon-on-insulator (SOl). Three gate-oxide layers embedded... We propose and analyze a novel Si-based electro-optic modulator with an improved metal-oxide-semiconductor (MOS) capacitor configuration integrated into silicon-on-insulator (SOl). Three gate-oxide layers embedded in the silicon waveguide constitute a triple MOS capacitor structure, which boosts the modulation efficiency compared with a single MOS capacitor. The simulation results demonstrate that the Vπ Lπ product is 2. 4V · cm. The rise time and fall time of the proposed device are calculated to be 80 and 40ps from the transient response curve, respectively,indicating a bandwidth of 8GHz. The phase shift efficiency and bandwidth can be enhanced by rib width scaling. 展开更多
关键词 carrier accumulation plasma dispersion effect electro-optic phase modulator METAL-OXIDE-SEMICONDUCTOR optoelectronic integrated circuit
下载PDF
Mach-Zehnder Electro-Optic Polymer Modulator with C orona Poled Core Layer 被引量:3
13
作者 杨晓红 杜云 +1 位作者 石志文 吴荣汉 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2001年第8期971-974,共4页
A Mach-Zehnder(MZ) electro-optic(EO) modulator are real iz ed,with three optical layers as polymer materials.The functional layer is the co rona poled crosslinkable polyurethane.The ridge waveguide is fabricated by us... A Mach-Zehnder(MZ) electro-optic(EO) modulator are real iz ed,with three optical layers as polymer materials.The functional layer is the co rona poled crosslinkable polyurethane.The ridge waveguide is fabricated by using the spin-coating,poling,photolithography and oxygen reactive ion etching(RIE) techniques.The mode and the modulation properties of these devices are demonstra ted in a micron control system,while the light source works at the wavelength of 1 31 or 1 55 micron. 展开更多
关键词 poled polymer M Z waveguide electro-optic modulator
下载PDF
Treatment outcomes for different subgroups of nasopharyngeal carcinoma patients treated with intensity-modulated radiation therapy 被引量:40
14
作者 Sheng-Fa Su 1,2,3,Fei Han 1,2,Chong Zhao 1,2,Ying Huang 1,2,Chun-Yan Chen 1,2,Wei-Wei Xiao 1,2,Jia-Xin Li 1,2 and Tai-Xiang Lu 1,2 1 State Key Laboratory of Oncology in South China,Guangzhou,Guangdong 510060,P.R.China 2 Department of Radiation Oncology,Sun Yat-sen University Cancer Center,Guangzhou,Guangdong 510060,P.R.China 3 Department of Oncology,Guiyang Medical College Hospital,Tumor Hospital of Guizhou,Guiyang,Guizhou 550003,P.R.China. 《Chinese Journal of Cancer》 SCIE CAS CSCD 北大核心 2011年第8期565-573,共9页
Although many studies have investigated intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC),sample sizes in the reported studies are usually small and different in outcomes in different T a... Although many studies have investigated intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC),sample sizes in the reported studies are usually small and different in outcomes in different T and N subgroups are seldom analyzed.Herein,we evaluated the outcomes of NPC patients treated with IMRT and further explored treatment strategy to improve such outcome.We collected clinical data of 865 NPC patients treated with IMRT alone or in combination with chemotherapy,and classified all cases into the following prognostic categories according to different TNM stages:early stage group (T1-2N0-1M0),advanced local disease group (T3-4N0-1M0),advanced nodal disease group (T1-2N2-3M0),and advanced locoregional disease group (T3-4N2-3M0).The 5-year overall survival (OS),local relapse-free survival (LRFS),and distant metastases-free survival (DMFS) were 83.0%,90.4%,and 84.0%,respectively.The early disease group had the lowest treatment failure rate,with a 5-year OS of 95.6%.The advanced local disease group and advanced nodal disease group had similar failure pattern and treatment outcomes as well as similar hazard ratios for death (4.230 and 4.625,respectively).The advanced locoregional disease group had the highest incidence of relapse and death,with a 5-year DMFS and OS of 62.3% and 62.2%,respectively,and a hazard ratio for death of 10.402.Comparing with IMRT alone,IMRT in combination with chemotherapy provided no significant benefit to locoregionally advanced NPC.Our results suggest that the decision of treatment strategy for NPC patients should consider combinations of T and N stages,and that IMRT alone for early stage NPC patients can produce satisfactory results.However,for advanced local,nodal,and locoregional disease groups,a combination of chemotherapy and radiotherapy is recommended. 展开更多
关键词 放射治疗 强度调制 鼻咽癌 患者 调控 样本大小 临床资料 结合治疗
下载PDF
Dosimetric Improvements Utilising Intensity Modulated Radiation Therapy for Patients with Glioblastoma Multiforme 被引量:2
15
作者 Michael Back Shaun Clifford +1 位作者 Helen Wheeler Thomas Eade 《Journal of Cancer Therapy》 2013年第11期18-24,共7页
Aims: The EORTC-NCI study investigating the addition of temozolomide trial to standard radiation therapy has demonstrated improved duration of survival in patients with Glioblastoma multiforme (GBM). With longer survi... Aims: The EORTC-NCI study investigating the addition of temozolomide trial to standard radiation therapy has demonstrated improved duration of survival in patients with Glioblastoma multiforme (GBM). With longer survival duration, there is the potential for latent RT morbidity, not previously seen in historical patients. This study evaluates the potential dosimetric advantages of utilising IMRT over 3D-conformal RT in such patients. Methods: 10 consecutive patients with GBM formally screened for a clinical study over a two-month period were planned and treated with IMRT utilising daily on-board imaging (OBI). The EORTC protocol dosimetric criteria and constraints were used in target delineation and planning. For each patient, a 3DCRT plan was also produced. Endpoints for dosimetric evaluation analysed related to tumour dose: mean PTV60 dose (mPTV60Dose), Conformity Index (CI);and normal tissue dose: mean normal brain dose (mBrainDose) and V40 Brain (Brainv40). IGRT endpoints were the median isocentre shifts required in 3 axes measured in one direction. The variation between the IMRT and 3DCRT dosimetric endpoints was examined using Wilcoxon analysis. Results: The 10 patients had tumours located in temporal (3), parietal (3), occipital (2) and callosal (2) regions. The median PTV and normal brain volumes were 308.1 cm3 and 1077.5 cm3 respectively. The IMRT dosimetry was significantly improved in all endpoints specifically CI (p = 0.002), mPTV60Dose (p = 0.004), mBrainDose (p = 0.002) and Brainv40 (p = 0.019). OBI directed isocentre measurements in the patient group were available for 230 treatments. The median shifts (and 95% C.I.s) were 0.1 cm vertical (0.1 - 0.2), 0.1 cm longitudinal (0.1 - 0.2) and 0.2 cm lateral (0.2 - 0.2). At a minimum follow-up of 2 years’ post diagnosis, the median survival of the group is 18.0 months (95% CI: 13.4 - 22.6 months). Conclusion: IMRT for GBM produces significant dosimetric advantages in relation to planning target volume and normal tissue dose compared with 3D conformal plans. The data also confirm the accuracy of IMRT technique for CNS with IGRT delivery utilising OBI demonstrating minimal deviation from planned to treated isocentre. 展开更多
关键词 intensity modulATED Radiation THERAPY GLIOBLASTOMA DOSIMETRY
下载PDF
Intensity modulated radiation therapy with simultaneous integrated boost based dose escalation on neoadjuvant chemoradiation therapy for locally advanced distal esophageal adenocarcinoma 被引量:1
16
作者 Ming Zeng Fernando N Aguila +4 位作者 Taral Patel Mark Knapp XueQiang Zhu XiLin Chen Phillip D Price 《World Journal of Gastrointestinal Oncology》 SCIE CAS 2016年第5期474-480,共7页
AIM:To evaluate impact of radiation therapy dose escalation through intensity modulated radiation therapy with simultaneous integrated boost(IMRT-SIB).METHODS:We retrospectively reviewed the patients who underwent fou... AIM:To evaluate impact of radiation therapy dose escalation through intensity modulated radiation therapy with simultaneous integrated boost(IMRT-SIB).METHODS:We retrospectively reviewed the patients who underwent four-dimensional-based IMRT-SIBbased neoadjuvant chemoradiation protocol.During the concurrent chemoradiation therapy,radiation therapy was through IMRT-SIB delivered in 28 consecutive daily fractions with total radiation doses of 56 Gy to tumor and 5040 Gy dose-painted to clinical tumor volume,with a regimen at the discretion of the treating medical oncologist.This was followed by surgical tumor resection.We analyzed pathological completion response(p CR) rates its relationship with overall survival and event-freesurvival.RESULTS:Seventeen patients underwent dose escalation with the IMRT-SIB protocol between 2007 and 2014 and their records were available for analysis.Among the IMRT-SIB-treated patients,the toxicity appeared mild,the most common side effects were grade 1-3 esophagitis(46%) and pneumonitis(11.7%).There were no cardiac events.The Ro resection rate was 94%(n = 16),the p CR rate was 47%(n = 8),and the postoperative morbidity was zero.There was one mediastinal failure found,one patient had local failure at the anastomosis site,and the majority of failures were distant in the lung or bone.The 3-year diseasefree survival and overall survival rates were 41%(n = 7) and 53%(n = 9),respectively.CONCLUSION:The dose escalation through IMRT-SIB in the chemoradiation regimen seems responsible for down-staging the distal esophageal with well-tolerated complications. 展开更多
关键词 intensity modulated radiation therapy ESOPHAGEAL ADENOCARCINOMA Simultaneous integrated boost NEOADJUVANT CHEMORADIATION Dose ESCALATION Resection rate
下载PDF
Leakage-Penumbra effect in intensity modulated radiation therapy step-and-shoot dose delivery 被引量:1
17
作者 Grigor N Grigorov James CL Chow 《World Journal of Radiology》 CAS 2016年第1期73-81,共9页
AIM: To study the leakage-penumbra(LP) effect with a proposed correction method for the step-and-shoot intensity modulated radiation therapy(IMRT).METHODS: Leakage-penumbra dose profiles from 10 randomly selected pros... AIM: To study the leakage-penumbra(LP) effect with a proposed correction method for the step-and-shoot intensity modulated radiation therapy(IMRT).METHODS: Leakage-penumbra dose profiles from 10 randomly selected prostate IMRT plans were studied. The IMRT plans were delivered by a Varian 21 EX linear accelerator equipped with a 120-leaf multileaf collimator(MLC). For each treatment plan created by the Pinnacle3 treatment planning system,a 3-dimensional LP dose distribution generated by 5 coplanar photon beams,starting from 0o with equal separation of 72 o,was investigated. For each photon beam used in the stepand-shoot IMRT plans,the first beam segment was set to have the largest area in the MLC leaf-sequencing,and was equal to the planning target volume(PTV). The overshoot effect(OSE) and the segment positional errors were measured using a solid water phantom with Kodak(TL and X-OMAT V) radiographic films. Film dosimetric analysis and calibration were carried out using a film scanner(Vidar VXR-16). The LP dose profiles were determined by eliminating the OSE and segment positional errors with specific individual irradiations. RESULTS: A non-uniformly distributed leaf LP dose ranging from 3% to 5% of the beam dose was measured in clinical IMRT beams. An overdose at the gap between neighboring segments,represented as dose peaks of up to 10% of the total BP,was measured. The LP effect increased the dose to the PTV and surrounding critical tissues. In addition,the effectdepends on the number of beams and segments for each beam. Segment positional error was less than the maximum tolerance of 1 mm under a dose rate of 600 monitor units per minute in the treatment plans. The OSE varying with the dose rate was observed in all photon beams,and the effect increased from 1 to 1.3 Gy per treatment of the rectal intersection. As the dosimetric impacts from the LP effect and OSE may increase the rectal post-radiation effects,a correction of LP was proposed and demonstrated for the central beam profile for one of the planned beams. CONCLUSION: We concluded that the measured dosimetric impact of the LP dose inaccuracy from photon beam segment in step-and-shoot IMRT can be corrected. 展开更多
关键词 Multileaf COLLIMATOR LEAKAGE OVERSHOOT EFFECT Beam PENUMBRA PROSTATE intensity modulated radiation therapy planning
下载PDF
Organic electro-optic polymer materials and organic-based hybrid electro-optic modulators 被引量:1
18
作者 Yan Wang Tongtong Liu +3 位作者 Jiangyi Liu Chuanbo Li Zhuo Chen Shuhui Bo 《Journal of Semiconductors》 EI CAS CSCD 2022年第10期28-38,共11页
High performance electro-optic modulator,as the key device of integrated ultra-wideband optical systems,have be-come the focus of research.Meanwhile,the organic-based hybrid electro-optic modulators,which make full us... High performance electro-optic modulator,as the key device of integrated ultra-wideband optical systems,have be-come the focus of research.Meanwhile,the organic-based hybrid electro-optic modulators,which make full use of the advant-ages of organic electro-optic(OEO)materials(e.g.high electro-optic coefficient,fast response speed,high bandwidth,easy pro-cessing/integration and low cost)have attracted considerable attention.In this paper,we introduce a series of high-perform-ance OEO materials that exhibit good properties in electro-optic activity and thermal stability.In addition,the recent progress of organic-based hybrid electro-optic devices is reviewed,including photonic crystal-organic hybrid(PCOH),silicon-organic hy-brid(SOH)and plasmonic-organic hybrid(POH)modulators.A high-performance integrated optical platform based on OEO ma-terials is a promising solution for growing high speeds and low power consumption in compact sizes. 展开更多
关键词 organic electro-optic materials modulATOR organic-based hybrid modulator heterogeneous integration
下载PDF
Long-term outcomes of a phase Ⅱ randomized controlled trial comparing intensity-modulated radiotherapy with or without weekly cisplatin for the treatment of locally recurrent nasopharyngeal carcinoma 被引量:20
19
作者 Ying Guan Shuai Liu +6 位作者 Han-Yu Wang Ying Guo Wei-Wei Xiao Chun-Yan Chen Chong Zhao Tai-Xiang Lu Fei Han 《Chinese Journal of Cancer》 SCIE CAS CSCD 2016年第4期181-189,共9页
Background:Salvage treatment for locally recurrent nasopharyngeal carcinoma(NPC) is complicated and relatively limited.Radiotherapy,combined with effective concomitant chemotherapy,may improve clinical treatment outco... Background:Salvage treatment for locally recurrent nasopharyngeal carcinoma(NPC) is complicated and relatively limited.Radiotherapy,combined with effective concomitant chemotherapy,may improve clinical treatment outcomes.We conducted a phase Ⅱ randomized controlled trial to evaluate the efficacy of intensity-modulated radiotherapy with concomitant weekly cisplatin on locally recurrent NPC.Methods:Between April 2002 and January 2008,69 patients diagnosed with non-metastatic locally recurrent NPC were randomly assigned to either concomitant chemoradiotherapy group(n = 34) or radiotherapy alone group(n = 35).All patients received intensity-modulated radiotherapy.The radiotherapy dose for both groups was 60 Gy in 27 fractions for 37 days(range 23-53 days).The concomitant chemotherapy schedule was cisplatin 30 mg/m^2 by intravenous infusion weekly during radiotherapy.Results:The median follow-up period of all patients was 35 months(range 2-112 months).Between concomitant chemoradiotherapy and radiotherapy groups,there was only significant difference in the 3-year and 5-year overall survival(OS) rates(68.7%vs.42.2%,P = 0.016 and 41.8%vs.27.5%,P = 0.049,respectively).Subgroup analysis showed that concomitant chemoradiotherapy significantly improved the 5-year OS rate especially for patients in stage rT3-4(33.0%vs.13.2%,P = 0.009),stages Ⅲ-Ⅳ(34.3%vs.13.2%,P = 0.006),recurrence interval >30 months(49.0%vs.20.6%,P = 0.017),and tumor volume >26 cm^3(37.6%vs.0%,P = 0.006).Conclusion:Compared with radiotherapy alone,concomitant chemoradiotherapy can improve OS of the patients with locally recurrent NPC,especially those with advanced T category(rT3-4) and stage(lll-IV) diseases,recurrence intervals >30 months,and tumor volume >26 cm^3. 展开更多
关键词 Recurrence NASOPHARYNGEAL carcinoma intensity-modulATED radiation therapy CONCOMITANT CHEMORADIOTHERAPY CISPLATIN
下载PDF
Prognostic factors and failure patterns in non-metastatic nasopharyngeal carcinoma after intensity-modulated radiotherapy 被引量:43
20
作者 Yan-Ping Mao Ling-Long Tang +7 位作者 Lei Chen Ying Sun Zhen-Yu Qi Guan-Qun Zhou Li-Zhi Liu Li Li Ai-Hua Lin Jun Ma 《Chinese Journal of Cancer》 SCIE CAS CSCD 2016年第12期673-682,共10页
Background: The prognostic values of staging parameters require continual re?assessment amid changes in diag?nostic and therapeutic methods. This study aimed to identify the prognostic factors and failure patterns of ... Background: The prognostic values of staging parameters require continual re?assessment amid changes in diag?nostic and therapeutic methods. This study aimed to identify the prognostic factors and failure patterns of non?meta?static nasopharyngeal carcinoma(NPC) in the intensity?modulated radiotherapy(IMRT) era.Methods: We reviewed the data from 749 patients with newly diagnosed, biopsy?proven, non?metastatic NPC in our cancer center(South China, an NPC endemic area) between January 2003 and December 2007. All patients under?went magnetic resonance imaging(MRI) before receiving IMRT. The actuarial survival rates were estimated using the Kaplan–Meier method, and survival curves were compared using the log?rank test. Multivariate analyses with the Cox proportional hazards model were used to test for the independent prognostic factors by backward eliminating insigniicant explanatory variables.Results: The 5?year occurrence rates of local failure, regional failure, locoregional failure, and distant failure were 5.4, 3.0, 7.4, and 17.4%, respectively. The 5?year survival rates were as follows: local relapse?free survival, 94.6%; nodal relapse?free survival, 97.0%; distant metastasis?free survival, 82.6%; disease?free survival, 75.1%; and overall survival, 82.0%. Multivariate Cox regression analysis revealed that orbit involvement was the only signiicant prognostic fac?tor for local failure(P = 0.011). Parapharyngeal tumor extension, retropharyngeal lymph node involvement, and the laterality, longest diameter, and Ho's location of the cervical lymph nodes were signiicant prognostic factors for both distant failure and disease failure(all P < 0.05). Intracranial extension had signiicant prognostic value for distant failure(P = 0.040).Conclusions: The key failure pattern for NPC was distant metastasis in the IMRT era. With changes in diagnostic and therapeutic technologies as well as treatment modalities, the signiicant prognostic parameters for local control have also been altered substantially. 展开更多
关键词 Nasopharyngeal carcinoma intensity-modulated radiotherapy PROGNOSIS Failure pattern Tumor staging
下载PDF
上一页 1 2 228 下一页 到第
使用帮助 返回顶部