Endocrine dysfunction has an adverse impact on the cardiovascular system that may be due to an endocrine abnormality that leads to electrocardiogram (EKG) changes. The EKG changes due to endocrine disorder can be reve...Endocrine dysfunction has an adverse impact on the cardiovascular system that may be due to an endocrine abnormality that leads to electrocardiogram (EKG) changes. The EKG changes due to endocrine disorder can be reversible and irreversible and treating underlying disease can reverse EKG changes in some cases. In this article, we review the electrocardiogram manifestations of various endocrine disorders.展开更多
Background There are limited data on the prevalence of electrocardiographic (ECG) abnormalities, and their value for predicting a major adverse cardiovascular event (MACE) in patients at high cardiovascular risk. This...Background There are limited data on the prevalence of electrocardiographic (ECG) abnormalities, and their value for predicting a major adverse cardiovascular event (MACE) in patients at high cardiovascular risk. This study aimed to determine the prevalence of ECG abnormalities in patients at high risk for cardiovascular events, and to identify ECG abnormalities that significantly predict MACE. Methods Patients aged ≥ 45 years with established atherosclerotic disease (EAD) were consecutively enrolled from the outpatient clinics of the six participating hospitals during April 2011 to March 2014. The following data were collected: demographic data, cardiovascular risk factors, history of cardiovascular event, physical examination, ECG and medications. ECG was analyzed using Minnesota Code criteria. MACE included cardiovascular death, non-fatal myocardial infarction, and hospitalization due to unstable angina or heart failure. Results A total of 2009 patients were included, 1048 patients (52.2%) had established EAD, and 961 patients (47.8%) had multiple risk factors (MRF). ECG abnormalities included atrial fibrillation (6.7%), premature ventricular contraction (5.4%), pathological Q-wave (Q/QS)(21.3%), T-wave inversion (20.0%), intraventricular ventricular conduction delay (IVCD)(7.3%), left ventricular hypertrophy (LVH)(12.2%), and AV block (12.5%). MACE occurred in 88 patients (4.4%). Independent predictors of MACE were chronic kidney disease, EAD, and the presence of atrial fibrillation, Q/QS, IVCD or LVH by ECG. Conclusions A high prevalence of ECG abnormalities was found. The prevalence of ECG abnormalities was high even among those with risk factors without documented cardiovascular disease.展开更多
As a result of research, high prevalence of arterial hypertension has been identified in the group of patients with coronary heart disease aged 60 and older. Most often, occurring form of arterial hypertension among g...As a result of research, high prevalence of arterial hypertension has been identified in the group of patients with coronary heart disease aged 60 and older. Most often, occurring form of arterial hypertension among geriatric patients is isolated systolic arterial hypertension (ISAH). The comparison of two ethnic groups of the population has showed higher levels of systolic and diastolic blood pressure (SBP and DBP) in the group of patients of non-indigenous nationality, rather than Yakut patients. Correlation was recorded in the group of non-indigenous patients as they age. Significant increase in the level of SBP was identified in the group of senile and long-livers than in the elderly. Detection of ECG signs of LVH showed the lowest specificity of Cornell voltage criterion comparing to Sokolow-Lyon criterion with its more often occurrence. ECG-signs of left ventricle hypertrophy are significantly more often established by Sokolow-Lyon criterion for men, Cornell voltage—for women. Correlation has been found between the presence of LVH and combination of Cornell voltage criterion with both Gubner-Ungerleider and Sokolow-Lyon criteria.展开更多
AIMTo investigate validity of electrocardiographic(ECG)criteria for left ventricular hypertrophy(LVH)in young adults.METHODS Retrospectively,echocardiograms showing LVH and concomitant electrocardiograms were collecte...AIMTo investigate validity of electrocardiographic(ECG)criteria for left ventricular hypertrophy(LVH)in young adults.METHODS Retrospectively,echocardiograms showing LVH and concomitant electrocardiograms were collected in patients 18 to 39 years old.A control group of patients without LVH was collected.Using echocardiogram as the gold standard,electrocardiograms were analyzed using common voltage criteria.RESULTS Study included 100 subjects(52%male,mean age=28±6.8 years,96%Hispanic or African-American)with 50%LVH prevalence.Sensitivity and specificity for SokolowLyon criteria were 24%(95%CI:13.5%-38.4%)and 88%(95%CI:74.9%-95%).For Cornell criteria,sensitivity was 32%(95%CI:19.9%-46.8%)and specificity 98%(95%CI:87.9%-99.8%).For R in a VL criteria,sensitivity was 12%(95%CI:4.9%-25%)and specificity 100%(95%CI:91.1%-100%).CONCLUSION In young adults common ECG voltage criteria have low sensitivities and high specificities similar to other age groups.Low sensitivities preclude these ECG criteria from serving as effective screening tests.展开更多
The increase in health care costs is not sustainable and has heightened the need for innovative low cost effective strategies for delivering patient care. Remote monitoring holds great promise for preventing or shorte...The increase in health care costs is not sustainable and has heightened the need for innovative low cost effective strategies for delivering patient care. Remote monitoring holds great promise for preventing or shortening duration of hospitalization even while improving quality of care. We therefore conducted a proof of concept study to examine the quality of electrocardiograph (ECG) recordings obtained remotely and to test its potential utility in detecting harmful rhythms such as atrial fibrillation. We tested a novel adhesive strip ECG monitor and assessed the ECG quality in ambulatory individuals. 2630 ECG strips were analyzed and classified as: Sinus, atrial fibrillation (AF), indeterminate, or other. Four readers independently rated ECG quality: 0: Noise; 1: QRS complexes seen, but P-wave indeterminate; 2: QRS complexes seen, P-waves seen but poor quality; and 3: Clean QRS complexes and P-waves. The combined average rating was: Noise 12%; R-R, no P-wave 10%; R-R, no PR interval 18%; and R-R with PR interval 60% (if Sinus). If minimum diagnostic quality was a score of 1, 88% of strips were diagnostic. There was moderate to high agreement regarding quality (weighted Kappa statistic values; 0.58 to 0.76) and high level of agreement regarding ECG diagnosis (ICC = 0.93). A highly variable RR interval (HRV ≥ 7) predicted AF (AUC = 0.87). The monitor acquires and transmits diagnostic high quality ECG data and permits characterization of AF.展开更多
<strong>Objective:</strong> <span style="font-family:Verdana;">To determine the early electrocardiographic changes in a cohort of ambulatory cameroonian COVID-19 patients treated with hydro...<strong>Objective:</strong> <span style="font-family:Verdana;">To determine the early electrocardiographic changes in a cohort of ambulatory cameroonian COVID-19 patients treated with hydroxychlo</span><span style="font-family:Verdana;">- </span><span style="font-family:;" "=""><span style="font-family:Verdana;">roquine and Azithromycin. </span><b><span style="font-family:Verdana;">Design:</span></b><span style="font-family:Verdana;"> Prospective study. </span><b><span style="font-family:Verdana;">Setting:</span></b><span style="font-family:Verdana;"> Treatment centres of the city of Yaounde, Cameroon, from May 7</span><sup><span style="font-size:12px;font-family:Verdana;">th</span></sup><span style="font-family:Verdana;"> to 24</span><sup><span style="font-size:12px;font-family:Verdana;">th</span></sup><span style="font-family:Verdana;"> 2020. </span><b><span style="font-family:Verdana;">Participants:</span></b><span style="font-family:Verdana;"> We enrolled 51 consecutive confirmed COVID-19 on RT-PCR who having mild forms of COVID-19 and treated by hydroxychloroquine 200</span></span><span style="font-family:Verdana;"> </span><span style="font-family:;" "=""><span style="font-family:Verdana;">mg twice daily during seven #days plus Azithromycin 500 mg the first day and 250 mg the remaining 4 days as per national standard. </span><b><span style="font-family:Verdana;">Main Outcomes Measures:</span></b><span style="font-family:Verdana;"> The</span><b><span style="font-family:Verdana;"> </span></b><span style="font-family:Verdana;">primary end-point was the change in QTc interval between day 0 (D0), day 3 (D3) and day 7 (D7). Secondary endpoints were changes in all other cardiac electrical conductivity patterns and the occurrence of clinical arrhythmic events during the course of treatment. </span><b><span style="font-family:Verdana;">Results: </span></b><span style="font-family:Verdana;">The population (29 men and 22 women) was aged 39 ± 11 years (range 17 to 61 years). Mean Tisdale score was 3.35 ± 0.48. No significant change from baseline (D0) of QTc was observed at D7 (429 ± 27 ms at D0 versus 396 ± 26 ms at D7;p = 0.27). A reduction of heart rate was observed between the D0 and D7 (75 ± 13 bpm versus 70 ± 13 bpm, p = 0.02) with increased QRS duration between D0 and D7 (95 ± 10 ms versus 102 ± 17 ms, p = 0.004). No symptomatic arrhythmic events occurred during the treatment course. </span><b><span style="font-family:Verdana;">Conclusions: </span></b><span style="font-family:Verdana;">No life-threatening modification of the QT interval was observed in non-severe COVID-19 patients treated ambulatory with hydroxychloroquine and azith</span></span><span style="font-family:Verdana;">romycin. Studies are needed in critical-ill and older patients.</span>展开更多
Background Electrocardiographic (ECG) changes occurring during the course of acute brain injury (ABI) have been described frequently, but their significances remain uncertain. The present study was designed to inv...Background Electrocardiographic (ECG) changes occurring during the course of acute brain injury (ABI) have been described frequently, but their significances remain uncertain. The present study was designed to investigate the relation of ECG abnormalities to outcome in the patients with ABI. Methods We performed a retrospective, observational study on the ABI patients admitted to the Department of Neurosurgery of the Beijing Tiantan Hospital between December 2005 and December 2007. All the patients accepted 12-lead electrocardiographic examination within 24 hours after injury, then divided into three groups according to the Glasgow coma score (GCS). In-hospital mortality and one-month outcome assessed by the Glasgow outcome score (GOS) were investigated. Results Of 335 ABI patients (mean ages 32.4 years), 246 patients (73.4%) had abnormal ECGs. The most common abnormality was ST-T changes (41.5%), followed by sinus tachycardia (23.6%). ECG changes had a significant association with the severity and outcome. Logistic regression analysis showed the presence of ST-T changes (OR 2.587, 95%C/1.009 to 6.629, P=0.048) and QT dispersion prolongation (OR 4.656, 95%C/1.956 to 11.082, P=0.001) significantly associated with short outcomes. Conclusions ABI can lead to myocardial damage and ECG changes had a significant association with the severity. ST-T changes and QT dispersion prolongation were the independent prognosis factors for the negative outcome of ABI patients.展开更多
Cardiovascular diseases(CVDs)are fatal chronic diseases,where electrocardiography(ECG)monitoring could be a prominent solution for early diagnosis.In spite of available commercialized,multilead ECG devices,bulky forma...Cardiovascular diseases(CVDs)are fatal chronic diseases,where electrocardiography(ECG)monitoring could be a prominent solution for early diagnosis.In spite of available commercialized,multilead ECG devices,bulky formats,discontinuous monitoring,and no safety alarm system significantly limit their practical applications.Herein,we present a soft,and stretchable,three-lead ECG device allowing continuous monitoring and wireless transmission of ECG signals.A newly developed organohydrogel patch with a strong adhesive ability(~9.9 kPa)and higher conductivity(~6.5 kΩ)is applied for high-quality ECG signals collection.With a long operation duration(6.5 h)and wireless transmission distance(20.9 m),it could fulfill most of the daily applications.Machine learning algorithms and the graphical user interface are used for real-time ECG monitoring and cardiac abnormalities diagnosis.The vibratory flexible actuator,which is triggered by cardiac abnormalities that need immediate medical treatment,is also integrated as a warning system for the user.As a newly reported stretchable multi-lead ECG device for long-term ECG signal monitoring,there is a high potential for improving users'life quality with the high-risk population of CVDs.展开更多
文摘Endocrine dysfunction has an adverse impact on the cardiovascular system that may be due to an endocrine abnormality that leads to electrocardiogram (EKG) changes. The EKG changes due to endocrine disorder can be reversible and irreversible and treating underlying disease can reverse EKG changes in some cases. In this article, we review the electrocardiogram manifestations of various endocrine disorders.
基金supported by the Heart Association of Thailand under the Royal Patronage of H.M. the King, National Research Council of Thailand
文摘Background There are limited data on the prevalence of electrocardiographic (ECG) abnormalities, and their value for predicting a major adverse cardiovascular event (MACE) in patients at high cardiovascular risk. This study aimed to determine the prevalence of ECG abnormalities in patients at high risk for cardiovascular events, and to identify ECG abnormalities that significantly predict MACE. Methods Patients aged ≥ 45 years with established atherosclerotic disease (EAD) were consecutively enrolled from the outpatient clinics of the six participating hospitals during April 2011 to March 2014. The following data were collected: demographic data, cardiovascular risk factors, history of cardiovascular event, physical examination, ECG and medications. ECG was analyzed using Minnesota Code criteria. MACE included cardiovascular death, non-fatal myocardial infarction, and hospitalization due to unstable angina or heart failure. Results A total of 2009 patients were included, 1048 patients (52.2%) had established EAD, and 961 patients (47.8%) had multiple risk factors (MRF). ECG abnormalities included atrial fibrillation (6.7%), premature ventricular contraction (5.4%), pathological Q-wave (Q/QS)(21.3%), T-wave inversion (20.0%), intraventricular ventricular conduction delay (IVCD)(7.3%), left ventricular hypertrophy (LVH)(12.2%), and AV block (12.5%). MACE occurred in 88 patients (4.4%). Independent predictors of MACE were chronic kidney disease, EAD, and the presence of atrial fibrillation, Q/QS, IVCD or LVH by ECG. Conclusions A high prevalence of ECG abnormalities was found. The prevalence of ECG abnormalities was high even among those with risk factors without documented cardiovascular disease.
文摘As a result of research, high prevalence of arterial hypertension has been identified in the group of patients with coronary heart disease aged 60 and older. Most often, occurring form of arterial hypertension among geriatric patients is isolated systolic arterial hypertension (ISAH). The comparison of two ethnic groups of the population has showed higher levels of systolic and diastolic blood pressure (SBP and DBP) in the group of patients of non-indigenous nationality, rather than Yakut patients. Correlation was recorded in the group of non-indigenous patients as they age. Significant increase in the level of SBP was identified in the group of senile and long-livers than in the elderly. Detection of ECG signs of LVH showed the lowest specificity of Cornell voltage criterion comparing to Sokolow-Lyon criterion with its more often occurrence. ECG-signs of left ventricle hypertrophy are significantly more often established by Sokolow-Lyon criterion for men, Cornell voltage—for women. Correlation has been found between the presence of LVH and combination of Cornell voltage criterion with both Gubner-Ungerleider and Sokolow-Lyon criteria.
文摘AIMTo investigate validity of electrocardiographic(ECG)criteria for left ventricular hypertrophy(LVH)in young adults.METHODS Retrospectively,echocardiograms showing LVH and concomitant electrocardiograms were collected in patients 18 to 39 years old.A control group of patients without LVH was collected.Using echocardiogram as the gold standard,electrocardiograms were analyzed using common voltage criteria.RESULTS Study included 100 subjects(52%male,mean age=28±6.8 years,96%Hispanic or African-American)with 50%LVH prevalence.Sensitivity and specificity for SokolowLyon criteria were 24%(95%CI:13.5%-38.4%)and 88%(95%CI:74.9%-95%).For Cornell criteria,sensitivity was 32%(95%CI:19.9%-46.8%)and specificity 98%(95%CI:87.9%-99.8%).For R in a VL criteria,sensitivity was 12%(95%CI:4.9%-25%)and specificity 100%(95%CI:91.1%-100%).CONCLUSION In young adults common ECG voltage criteria have low sensitivities and high specificities similar to other age groups.Low sensitivities preclude these ECG criteria from serving as effective screening tests.
文摘The increase in health care costs is not sustainable and has heightened the need for innovative low cost effective strategies for delivering patient care. Remote monitoring holds great promise for preventing or shortening duration of hospitalization even while improving quality of care. We therefore conducted a proof of concept study to examine the quality of electrocardiograph (ECG) recordings obtained remotely and to test its potential utility in detecting harmful rhythms such as atrial fibrillation. We tested a novel adhesive strip ECG monitor and assessed the ECG quality in ambulatory individuals. 2630 ECG strips were analyzed and classified as: Sinus, atrial fibrillation (AF), indeterminate, or other. Four readers independently rated ECG quality: 0: Noise; 1: QRS complexes seen, but P-wave indeterminate; 2: QRS complexes seen, P-waves seen but poor quality; and 3: Clean QRS complexes and P-waves. The combined average rating was: Noise 12%; R-R, no P-wave 10%; R-R, no PR interval 18%; and R-R with PR interval 60% (if Sinus). If minimum diagnostic quality was a score of 1, 88% of strips were diagnostic. There was moderate to high agreement regarding quality (weighted Kappa statistic values; 0.58 to 0.76) and high level of agreement regarding ECG diagnosis (ICC = 0.93). A highly variable RR interval (HRV ≥ 7) predicted AF (AUC = 0.87). The monitor acquires and transmits diagnostic high quality ECG data and permits characterization of AF.
文摘<strong>Objective:</strong> <span style="font-family:Verdana;">To determine the early electrocardiographic changes in a cohort of ambulatory cameroonian COVID-19 patients treated with hydroxychlo</span><span style="font-family:Verdana;">- </span><span style="font-family:;" "=""><span style="font-family:Verdana;">roquine and Azithromycin. </span><b><span style="font-family:Verdana;">Design:</span></b><span style="font-family:Verdana;"> Prospective study. </span><b><span style="font-family:Verdana;">Setting:</span></b><span style="font-family:Verdana;"> Treatment centres of the city of Yaounde, Cameroon, from May 7</span><sup><span style="font-size:12px;font-family:Verdana;">th</span></sup><span style="font-family:Verdana;"> to 24</span><sup><span style="font-size:12px;font-family:Verdana;">th</span></sup><span style="font-family:Verdana;"> 2020. </span><b><span style="font-family:Verdana;">Participants:</span></b><span style="font-family:Verdana;"> We enrolled 51 consecutive confirmed COVID-19 on RT-PCR who having mild forms of COVID-19 and treated by hydroxychloroquine 200</span></span><span style="font-family:Verdana;"> </span><span style="font-family:;" "=""><span style="font-family:Verdana;">mg twice daily during seven #days plus Azithromycin 500 mg the first day and 250 mg the remaining 4 days as per national standard. </span><b><span style="font-family:Verdana;">Main Outcomes Measures:</span></b><span style="font-family:Verdana;"> The</span><b><span style="font-family:Verdana;"> </span></b><span style="font-family:Verdana;">primary end-point was the change in QTc interval between day 0 (D0), day 3 (D3) and day 7 (D7). Secondary endpoints were changes in all other cardiac electrical conductivity patterns and the occurrence of clinical arrhythmic events during the course of treatment. </span><b><span style="font-family:Verdana;">Results: </span></b><span style="font-family:Verdana;">The population (29 men and 22 women) was aged 39 ± 11 years (range 17 to 61 years). Mean Tisdale score was 3.35 ± 0.48. No significant change from baseline (D0) of QTc was observed at D7 (429 ± 27 ms at D0 versus 396 ± 26 ms at D7;p = 0.27). A reduction of heart rate was observed between the D0 and D7 (75 ± 13 bpm versus 70 ± 13 bpm, p = 0.02) with increased QRS duration between D0 and D7 (95 ± 10 ms versus 102 ± 17 ms, p = 0.004). No symptomatic arrhythmic events occurred during the treatment course. </span><b><span style="font-family:Verdana;">Conclusions: </span></b><span style="font-family:Verdana;">No life-threatening modification of the QT interval was observed in non-severe COVID-19 patients treated ambulatory with hydroxychloroquine and azith</span></span><span style="font-family:Verdana;">romycin. Studies are needed in critical-ill and older patients.</span>
基金This study was supported by the National Natural Science Foundation of China (No. C03030201)
文摘Background Electrocardiographic (ECG) changes occurring during the course of acute brain injury (ABI) have been described frequently, but their significances remain uncertain. The present study was designed to investigate the relation of ECG abnormalities to outcome in the patients with ABI. Methods We performed a retrospective, observational study on the ABI patients admitted to the Department of Neurosurgery of the Beijing Tiantan Hospital between December 2005 and December 2007. All the patients accepted 12-lead electrocardiographic examination within 24 hours after injury, then divided into three groups according to the Glasgow coma score (GCS). In-hospital mortality and one-month outcome assessed by the Glasgow outcome score (GOS) were investigated. Results Of 335 ABI patients (mean ages 32.4 years), 246 patients (73.4%) had abnormal ECGs. The most common abnormality was ST-T changes (41.5%), followed by sinus tachycardia (23.6%). ECG changes had a significant association with the severity and outcome. Logistic regression analysis showed the presence of ST-T changes (OR 2.587, 95%C/1.009 to 6.629, P=0.048) and QT dispersion prolongation (OR 4.656, 95%C/1.956 to 11.082, P=0.001) significantly associated with short outcomes. Conclusions ABI can lead to myocardial damage and ECG changes had a significant association with the severity. ST-T changes and QT dispersion prolongation were the independent prognosis factors for the negative outcome of ABI patients.
基金supported by Hong Kong Center for Cerebra-Cardiovascular Health Engineering,City University of Hong Kong(Grants No.9667221,9680322)Research Grants Council of the Hong Kong Special Administrative Region(Nos.21210820,11213721)National Natural Science Foundation of China(No.62122002).
文摘Cardiovascular diseases(CVDs)are fatal chronic diseases,where electrocardiography(ECG)monitoring could be a prominent solution for early diagnosis.In spite of available commercialized,multilead ECG devices,bulky formats,discontinuous monitoring,and no safety alarm system significantly limit their practical applications.Herein,we present a soft,and stretchable,three-lead ECG device allowing continuous monitoring and wireless transmission of ECG signals.A newly developed organohydrogel patch with a strong adhesive ability(~9.9 kPa)and higher conductivity(~6.5 kΩ)is applied for high-quality ECG signals collection.With a long operation duration(6.5 h)and wireless transmission distance(20.9 m),it could fulfill most of the daily applications.Machine learning algorithms and the graphical user interface are used for real-time ECG monitoring and cardiac abnormalities diagnosis.The vibratory flexible actuator,which is triggered by cardiac abnormalities that need immediate medical treatment,is also integrated as a warning system for the user.As a newly reported stretchable multi-lead ECG device for long-term ECG signal monitoring,there is a high potential for improving users'life quality with the high-risk population of CVDs.