A Kelvin probe was used as reference in this study on electrochemical measurements of a simulatedmarine atmospheric corrosion system (electrode covered by a very thin electrolyte layer). The experimentalsetups for imp...A Kelvin probe was used as reference in this study on electrochemical measurements of a simulatedmarine atmospheric corrosion system (electrode covered by a very thin electrolyte layer). The experimentalsetups for improved measurements proved satisfactory for the conventional steady-state electrochemicalmeasurements in atmospheric studies.展开更多
Electrochemical techniques of the corrosion measurements of reinforcing steeI in concrete have been evaluated. These techniques include half-cell potential measurements, impressed voltage method, impressed current met...Electrochemical techniques of the corrosion measurements of reinforcing steeI in concrete have been evaluated. These techniques include half-cell potential measurements, impressed voltage method, impressed current method and potentiostatic polarization technique. The results of corrosion behaviour of the steel in both 5%NaCl and 5%MgSO4 show that each electrochemical technique provides some information about the condition of the steel bar or the corrosivity of the environment being evaluated, yet none provides a complete data regarding the corrosion resistance of reinforcing steel in aggressive media展开更多
A new theoretical method is proposed in the electrochemical measurement to obtain therelationship between flow parameter and the electrode current under the existence of ion migration ef-fect.In this way the measureme...A new theoretical method is proposed in the electrochemical measurement to obtain therelationship between flow parameter and the electrode current under the existence of ion migration ef-fect.In this way the measurement of local mass transfer coefficient,wall shear stress and liquid veloc-ity are presented and the experiment results are also described.展开更多
The up-to-date status of FeO, CaO, SiO2, P2O5, Ti2O3 and Cr2O3 activity measurements in metallurgical slags using electrochemical sensors is outlined. A description of theoretical concepts and practical sensors is pre...The up-to-date status of FeO, CaO, SiO2, P2O5, Ti2O3 and Cr2O3 activity measurements in metallurgical slags using electrochemical sensors is outlined. A description of theoretical concepts and practical sensors is presented including their determining features.展开更多
An electrochemical probe measurement system for detecting an electrogenerated etchant in solution is developed.Concentration distribution of electrogenerated etchant bromine as close as 8 micrometer to the surface of ...An electrochemical probe measurement system for detecting an electrogenerated etchant in solution is developed.Concentration distribution of electrogenerated etchant bromine as close as 8 micrometer to the surface of macrodisk is studied quantitatively.展开更多
The different electrocatalytic reactors could be constructed for the electrocatalytic oxidation of 2,2,3,3-tetrafluoro-1-propanol(TFP) with two typical MnO_x/Ti electrodes, i.e.the electrocatalytic membrane reactor(EC...The different electrocatalytic reactors could be constructed for the electrocatalytic oxidation of 2,2,3,3-tetrafluoro-1-propanol(TFP) with two typical MnO_x/Ti electrodes, i.e.the electrocatalytic membrane reactor(ECMR) with the Ti membrane electrode and the electrocatalytic reactor(ECR) with the traditional Ti plate electrode.For the electro-oxidation of TFP, the conversion with membrane electrode(70.1%) in the ECMR was 3.3 and 1.7 times higher than that of the membrane electrode without permeate flow(40.8%) in the ECMR and the plate electrode(21.5%) in the ECR, respectively.Obviously, the pore structure of membrane and convection-enhanced mass transfer in the ECMR dramatically improved the catalytic activity towards the electro-oxidation of TFP.The specific surface area of porous electrode was 2.22 m^2·g^(-1).The surface area of plate electrode was 2.26 cm^2(1.13 cm^2× 2).In addition, the electrochemical results showed that the mass diffusion coefficient of the MnO_x/Ti membrane electrode(1.80 × 10^(-6) cm^2·s^(-1)) could be increased to 6.87 × 10^(-6) cm^2·s^(-1) at the certain flow rate with pump, confirming the lower resistance of mass transfer due to the convection-enhanced mass transfer during the operation of the ECMR.Hence, the porous structure and convection-enhanced mass transfer would improve the electrochemical property of the membrane electrode and the catalytic performance of the ECMR,which could give guideline for the design and application of the porous electrode and electrochemical reactor.展开更多
The collectorless flotation behaviors of sphalerite in the presence of Cu 2+ ions have been established. The effects of pH, potential and Cu 2+ concentration on the flotation have been studied using a micro flotation ...The collectorless flotation behaviors of sphalerite in the presence of Cu 2+ ions have been established. The effects of pH, potential and Cu 2+ concentration on the flotation have been studied using a micro flotation cell specially designed, where the potential can be controlled by a potentiostat. The flotation results have shown that the Cu activated sphalerite displays a good collectorless floatability in a pH range of 0~13. The higher potentials can improve the flotation recovery. The surface species formed during the Cu ion activation have been examined using a special electrochemical technique—a composite sphalerite electrode. Zinc deficient sulfide (Zn 1- x Cu x S) and Cu poly sulfide (Cu y+z S y ) species have been determined. They are responsible for the collectorless flotation of sphalerite. In additional, they can improve the conductivity of the sphalerite surface.展开更多
The effects of Hg and Ga on the electrochemical corrosion behavior of Mg-5%Hg (molar fraction) alloys were investigated by the measurement of polarization curves and galvanostatic test. The microstructure of the alloy...The effects of Hg and Ga on the electrochemical corrosion behavior of Mg-5%Hg (molar fraction) alloys were investigated by the measurement of polarization curves and galvanostatic test. The microstructure of the alloys and the corroded surface of the specimens were investigated by scanning electron microscopy, X-ray diffractometry and emission spectrum analysis. It can be concluded that the addition of 1%Ga (molar fraction) reduces corrosion current density from 26.98 mA/cm2 to 2.34 mA/cm2; while the addition of 1%Hg (molar fraction) increases corrosion current density. The addition of Ga and Hg both promotes the electrochemical activity of the alloys and the influence of Ga is more effective than Hg. Mg-5%Hg-1%Ga alloy has the best electrochemical activity, showing mean potential of -1.992 V. The activation mechanism of the magnesium alloy produced by Hg and Ga was put forward. Magnesium atoms are dissolved in liquid Hg and Ga to form amalgam and undergo severe oxidation at the amalgam/electrolyte interface.展开更多
Three-dimensional hierarchical Co3O4 microstructures decorated with Ag and Cu oxides were prepared via displacement reaction and subsequent annealing treatment.Photocatalytic properties measurements revealed that the ...Three-dimensional hierarchical Co3O4 microstructures decorated with Ag and Cu oxides were prepared via displacement reaction and subsequent annealing treatment.Photocatalytic properties measurements revealed that the photocatalystic activities of Cu O/Co3O4 composites(Co3O4 microstructures decorated with Cu O)were enhanced while those of Ag2O/Co3O4 composites(Co3O4 microstructures decorated with Ag2O)were reduced,when compared with those of pure hierarchical Co3O4 microstructures toward the degradation of methyl orange.In addition,Cu O/Co3O4 composites exhibited an excellent recyclability ability of photodegradation.The electrochemical properties test indicated that both of the composite oxide electrodes exhibited excellent pseudocapacitive performance with relatively high specific capacitance and good long-term cycling stability.With the increase of the loaded Ag2O and Cu O dosages deposited on the Co3O4 microstructures surface,the specific capacitance values of the composites were increased.Ag2O/Co3O4 composite electrodes showed higher specific capacitance values and better cycling stability than Cu O/Co3O4 composite ones.展开更多
The corrosion behavior of water borne epoxy-ester primer coatings (10% - 50% PVCs) was evaluated through electrochemical techniques such as polarization and impedance spectroscopic (EIS) measurements. Studies were car...The corrosion behavior of water borne epoxy-ester primer coatings (10% - 50% PVCs) was evaluated through electrochemical techniques such as polarization and impedance spectroscopic (EIS) measurements. Studies were carried out for a longer duration of exposure extending up to 60 days in aqueous solution of NaCl (5%). Corrosion current (icorr), Corrosion potential (Ecorr), Coating resistance (Rc), Charge transfer resistance (Rct), Coating capacitance (Cc), Double layer capacitance (Cdl), break point frequency (fb), Water uptake (∮), diffusion coefficient (Dw) etc., indicated that 10% - 30% PVC coatings performed well in comparison to higher PVCs. Changes in the electrochemical characteristics were found to occur as a function of exposure time in all cases. The corrosion stability of the coatings were found to be greatly affected by the percentage of PVCs. Studies further indicated that when lower concentration of pigments were available, they remained completely surrounded by the binder;Thus leaving no space for the entry of corrosive agents. From these studies, it was concluded that the water borne paints could replace the conventional coatings, containing organic solvents. Therefore, water soluble epoxy-ester primers have to be employed in paints for developing eco- friendly coatings.展开更多
Cells are the basic unit of life.Electrochemical analysis of single cells/organelles is essential for uncovering the molecular mechanisms of physiological and pathological processes that are difficult to elucidate on ...Cells are the basic unit of life.Electrochemical analysis of single cells/organelles is essential for uncovering the molecular mechanisms of physiological and pathological processes that are difficult to elucidate on a larger scale.This paper provides an overview of the commonly used fabrication methods for micro/nanoelectrodes applied in the investigations of single cells/organelles as well as the corresponding electrochemical measurements over the last four years including extracellular measurement,combination of extra and intracellular measurement,intracellular reactive oxygen species and reactive nitrogen species(ROS/RNS)measurement,and isolated organelles measurement.展开更多
Corrosion degradation is detrimental to metal structures as it shortens their lifetime and leads to huge economic losses and unexpected disasters.Therefore,the detection and monitoring of corrosion degradation is of g...Corrosion degradation is detrimental to metal structures as it shortens their lifetime and leads to huge economic losses and unexpected disasters.Therefore,the detection and monitoring of corrosion degradation is of great importance.Herein,we briefly review the state-of-the-art electrochemical methods,instrumentation(based on virtual instrumentation),and advanced sensor/probes that are used in the field for the assessment of corrosion damage.Typical corrosion monitoring results,some of which have been obtained at Tianjin University in the past 30 years,for metallic materials and organic coating/metal systems in atmospheric,marine,and soil conditions in the field are presented.Detection methods,data analysis,and theoretical and mathematical models regarding each corrosion system are discussed,and the challenges,problems and possible solutions for each case are suggested.Lastly,future developments,such as wireless,intelligent,and automatic electrochemical measurement,that will augment the present electrochemical methods of evaluating corrosion degradation are summarized.展开更多
Electrochemical methods have been widely used in the chemical and pharmaceutical industries, which require accurate concentration measurements, chemical reaction detections and analyses. The electrochemical potentiost...Electrochemical methods have been widely used in the chemical and pharmaceutical industries, which require accurate concentration measurements, chemical reaction detections and analyses. The electrochemical potentiostat, the core element in electrochemical instruments, have been discussed as a hot topic addressing the difficulty of applying high-precision constant voltage and picoampere current measurements. Meanwhile, reliable potentiostats are in demand for complicated industrial environments with noises as well as requirements of remotemonitors. This paper describes a potentiostat for industrial glucose measurement that is not only accurate but also fault tolerant to guarantee high reliability in industrial environments. The instrument uses standard industrial communication protocols, proflbus, and a 4-20 mA current loop, for remote control and monitoring. Experimental results show that this design has 0.01% accuracy with 1 mV resolution for voltage applications and 0.01% accuracy with 1 pA resolution for current measurements. The design is also shown to be highly reliable in noisy environments.展开更多
文摘A Kelvin probe was used as reference in this study on electrochemical measurements of a simulatedmarine atmospheric corrosion system (electrode covered by a very thin electrolyte layer). The experimentalsetups for improved measurements proved satisfactory for the conventional steady-state electrochemicalmeasurements in atmospheric studies.
文摘Electrochemical techniques of the corrosion measurements of reinforcing steeI in concrete have been evaluated. These techniques include half-cell potential measurements, impressed voltage method, impressed current method and potentiostatic polarization technique. The results of corrosion behaviour of the steel in both 5%NaCl and 5%MgSO4 show that each electrochemical technique provides some information about the condition of the steel bar or the corrosivity of the environment being evaluated, yet none provides a complete data regarding the corrosion resistance of reinforcing steel in aggressive media
基金Supported by the National Natural Science Foundation of China.
文摘A new theoretical method is proposed in the electrochemical measurement to obtain therelationship between flow parameter and the electrode current under the existence of ion migration ef-fect.In this way the measurement of local mass transfer coefficient,wall shear stress and liquid veloc-ity are presented and the experiment results are also described.
文摘The up-to-date status of FeO, CaO, SiO2, P2O5, Ti2O3 and Cr2O3 activity measurements in metallurgical slags using electrochemical sensors is outlined. A description of theoretical concepts and practical sensors is presented including their determining features.
文摘An electrochemical probe measurement system for detecting an electrogenerated etchant in solution is developed.Concentration distribution of electrogenerated etchant bromine as close as 8 micrometer to the surface of macrodisk is studied quantitatively.
基金Supported by the National Natural Science Foundation of China(21676200,21576208)the Program for Innovative Research Team in University of Ministry of Education of China(IRT-17R80)+2 种基金the Science and Technology Plans of Tianjin(17JCYBJC19800)111 Project(B12015)College Students' Innovation and Entrepreneurship Project(201510058083)
文摘The different electrocatalytic reactors could be constructed for the electrocatalytic oxidation of 2,2,3,3-tetrafluoro-1-propanol(TFP) with two typical MnO_x/Ti electrodes, i.e.the electrocatalytic membrane reactor(ECMR) with the Ti membrane electrode and the electrocatalytic reactor(ECR) with the traditional Ti plate electrode.For the electro-oxidation of TFP, the conversion with membrane electrode(70.1%) in the ECMR was 3.3 and 1.7 times higher than that of the membrane electrode without permeate flow(40.8%) in the ECMR and the plate electrode(21.5%) in the ECR, respectively.Obviously, the pore structure of membrane and convection-enhanced mass transfer in the ECMR dramatically improved the catalytic activity towards the electro-oxidation of TFP.The specific surface area of porous electrode was 2.22 m^2·g^(-1).The surface area of plate electrode was 2.26 cm^2(1.13 cm^2× 2).In addition, the electrochemical results showed that the mass diffusion coefficient of the MnO_x/Ti membrane electrode(1.80 × 10^(-6) cm^2·s^(-1)) could be increased to 6.87 × 10^(-6) cm^2·s^(-1) at the certain flow rate with pump, confirming the lower resistance of mass transfer due to the convection-enhanced mass transfer during the operation of the ECMR.Hence, the porous structure and convection-enhanced mass transfer would improve the electrochemical property of the membrane electrode and the catalytic performance of the ECMR,which could give guideline for the design and application of the porous electrode and electrochemical reactor.
文摘The collectorless flotation behaviors of sphalerite in the presence of Cu 2+ ions have been established. The effects of pH, potential and Cu 2+ concentration on the flotation have been studied using a micro flotation cell specially designed, where the potential can be controlled by a potentiostat. The flotation results have shown that the Cu activated sphalerite displays a good collectorless floatability in a pH range of 0~13. The higher potentials can improve the flotation recovery. The surface species formed during the Cu ion activation have been examined using a special electrochemical technique—a composite sphalerite electrode. Zinc deficient sulfide (Zn 1- x Cu x S) and Cu poly sulfide (Cu y+z S y ) species have been determined. They are responsible for the collectorless flotation of sphalerite. In additional, they can improve the conductivity of the sphalerite surface.
基金Project(MKPT-02-181) supported by the National Defense Science and Technology Industry Committee of China
文摘The effects of Hg and Ga on the electrochemical corrosion behavior of Mg-5%Hg (molar fraction) alloys were investigated by the measurement of polarization curves and galvanostatic test. The microstructure of the alloys and the corroded surface of the specimens were investigated by scanning electron microscopy, X-ray diffractometry and emission spectrum analysis. It can be concluded that the addition of 1%Ga (molar fraction) reduces corrosion current density from 26.98 mA/cm2 to 2.34 mA/cm2; while the addition of 1%Hg (molar fraction) increases corrosion current density. The addition of Ga and Hg both promotes the electrochemical activity of the alloys and the influence of Ga is more effective than Hg. Mg-5%Hg-1%Ga alloy has the best electrochemical activity, showing mean potential of -1.992 V. The activation mechanism of the magnesium alloy produced by Hg and Ga was put forward. Magnesium atoms are dissolved in liquid Hg and Ga to form amalgam and undergo severe oxidation at the amalgam/electrolyte interface.
基金Funded by the National Natural Science Foundation of China(Nos.11374013 and 51672001)the Key Fund of Anhui Province(16030901039)+1 种基金the Outstanding Young Talent Fund of Anhui Province(J05201424)the Internation Cooperation Fund of Anhui Province(1704e1002209)
文摘Three-dimensional hierarchical Co3O4 microstructures decorated with Ag and Cu oxides were prepared via displacement reaction and subsequent annealing treatment.Photocatalytic properties measurements revealed that the photocatalystic activities of Cu O/Co3O4 composites(Co3O4 microstructures decorated with Cu O)were enhanced while those of Ag2O/Co3O4 composites(Co3O4 microstructures decorated with Ag2O)were reduced,when compared with those of pure hierarchical Co3O4 microstructures toward the degradation of methyl orange.In addition,Cu O/Co3O4 composites exhibited an excellent recyclability ability of photodegradation.The electrochemical properties test indicated that both of the composite oxide electrodes exhibited excellent pseudocapacitive performance with relatively high specific capacitance and good long-term cycling stability.With the increase of the loaded Ag2O and Cu O dosages deposited on the Co3O4 microstructures surface,the specific capacitance values of the composites were increased.Ag2O/Co3O4 composite electrodes showed higher specific capacitance values and better cycling stability than Cu O/Co3O4 composite ones.
文摘The corrosion behavior of water borne epoxy-ester primer coatings (10% - 50% PVCs) was evaluated through electrochemical techniques such as polarization and impedance spectroscopic (EIS) measurements. Studies were carried out for a longer duration of exposure extending up to 60 days in aqueous solution of NaCl (5%). Corrosion current (icorr), Corrosion potential (Ecorr), Coating resistance (Rc), Charge transfer resistance (Rct), Coating capacitance (Cc), Double layer capacitance (Cdl), break point frequency (fb), Water uptake (∮), diffusion coefficient (Dw) etc., indicated that 10% - 30% PVC coatings performed well in comparison to higher PVCs. Changes in the electrochemical characteristics were found to occur as a function of exposure time in all cases. The corrosion stability of the coatings were found to be greatly affected by the percentage of PVCs. Studies further indicated that when lower concentration of pigments were available, they remained completely surrounded by the binder;Thus leaving no space for the entry of corrosive agents. From these studies, it was concluded that the water borne paints could replace the conventional coatings, containing organic solvents. Therefore, water soluble epoxy-ester primers have to be employed in paints for developing eco- friendly coatings.
基金funding from Fundamental Research Funds for the Central Universities(No.20720220014)the National Natural Science Foundation of China(No.22204134).
文摘Cells are the basic unit of life.Electrochemical analysis of single cells/organelles is essential for uncovering the molecular mechanisms of physiological and pathological processes that are difficult to elucidate on a larger scale.This paper provides an overview of the commonly used fabrication methods for micro/nanoelectrodes applied in the investigations of single cells/organelles as well as the corresponding electrochemical measurements over the last four years including extracellular measurement,combination of extra and intracellular measurement,intracellular reactive oxygen species and reactive nitrogen species(ROS/RNS)measurement,and isolated organelles measurement.
基金the National Natural Science Foundation of China(Nos.52031007,52171077)partial support of his contribution to the work by the University of California at Berkeley。
文摘Corrosion degradation is detrimental to metal structures as it shortens their lifetime and leads to huge economic losses and unexpected disasters.Therefore,the detection and monitoring of corrosion degradation is of great importance.Herein,we briefly review the state-of-the-art electrochemical methods,instrumentation(based on virtual instrumentation),and advanced sensor/probes that are used in the field for the assessment of corrosion damage.Typical corrosion monitoring results,some of which have been obtained at Tianjin University in the past 30 years,for metallic materials and organic coating/metal systems in atmospheric,marine,and soil conditions in the field are presented.Detection methods,data analysis,and theoretical and mathematical models regarding each corrosion system are discussed,and the challenges,problems and possible solutions for each case are suggested.Lastly,future developments,such as wireless,intelligent,and automatic electrochemical measurement,that will augment the present electrochemical methods of evaluating corrosion degradation are summarized.
文摘Electrochemical methods have been widely used in the chemical and pharmaceutical industries, which require accurate concentration measurements, chemical reaction detections and analyses. The electrochemical potentiostat, the core element in electrochemical instruments, have been discussed as a hot topic addressing the difficulty of applying high-precision constant voltage and picoampere current measurements. Meanwhile, reliable potentiostats are in demand for complicated industrial environments with noises as well as requirements of remotemonitors. This paper describes a potentiostat for industrial glucose measurement that is not only accurate but also fault tolerant to guarantee high reliability in industrial environments. The instrument uses standard industrial communication protocols, proflbus, and a 4-20 mA current loop, for remote control and monitoring. Experimental results show that this design has 0.01% accuracy with 1 mV resolution for voltage applications and 0.01% accuracy with 1 pA resolution for current measurements. The design is also shown to be highly reliable in noisy environments.