A simple and sensitive flow injection method is presented for the determination of histidine based on its enhancement of electrogenerated chemiluminescence (ECL) of luminol. After optimization of the experimental para...A simple and sensitive flow injection method is presented for the determination of histidine based on its enhancement of electrogenerated chemiluminescence (ECL) of luminol. After optimization of the experimental parameters, the working range for histidine was in 1.0 x 10-6 to 1.0 x 10 -3 mol/L with a detection limit (S/N = 3) of 0.56 mmol/L. The relative standard deviation was 1.6% for 11 measurements of 5 x 10 5 mol/L histidine solution. The proposed method has been successfully applied to the determination of histidine in real pharmaceutical preparation.展开更多
A novel electrogenerated chemiluminescence(ECL)sensor for the determination of metoclopramide was developed by employing ruthenium complex as an ECL signal producer and an ordered mesoporous carbon(OMC)material as mod...A novel electrogenerated chemiluminescence(ECL)sensor for the determination of metoclopramide was developed by employing ruthenium complex as an ECL signal producer and an ordered mesoporous carbon(OMC)material as modified material.The ECL sensor was fabricated by adsorption ruthenium complex into a mixture of OMC and Nafion,which showed good electrochemical and ECL behaviors.It was found that the ECL intensity of the sensor fabricated was greatly enhanced in the presence of metoclopramide.Based on this finding,a highly sensitive and reproducible ECL method was developed for the determination of metoclopramide.The result showed that the ECL intensity was linear with the concentration of metoclopramide in the range from 1.0×10-10 to 5.0×10-7M and the detection limit was 3×10-11M.The ECL sensor exhibited a long-term stability and a fine reproducibility with relative standard deviation of 1.0 % for 1.0×10-10M metoclopramide in 18 continuous determinations.The developed method has been applied to the determination of metoclopramide in tablet samples with satisfactory results.展开更多
Electrogenerated chemiluminescence(electrochemiluminescence, ECL) generates species at electrode surfaces, which undergoes electron-transfer reactions and forms excited states to emit light. It has become a very power...Electrogenerated chemiluminescence(electrochemiluminescence, ECL) generates species at electrode surfaces, which undergoes electron-transfer reactions and forms excited states to emit light. It has become a very powerful analytical technique and has been widely used in such as clinical testing, biowarfare agent detection, and pharmaceutical analysis. This review focuses on the current trends of molecular recognition-based biosensing methods for pharmaceutical analysis since 2010. It introduces a background of ECL and presents the recent ECL developments in ECL immunoassay(ECLIA), immunosensors, enzyme-based biosensors, aptamer-based biosensors, and molecularly imprinted polymers(MIP)-based sensors. At last, the future perspective for these analytical methods is briefly discussed.展开更多
A new flow injection electrogenerated chemiluminescence(ECL)method for the determination of pefloxacin was developed.The method is based on the sensitiving effect of pefloxacin on the weak ECL signal of electrochemi...A new flow injection electrogenerated chemiluminescence(ECL)method for the determination of pefloxacin was developed.The method is based on the sensitiving effect of pefloxacin on the weak ECL signal of electrochemical oxidation of luminol on the platinum flake electrode in the medium of 0.05mol/L Na2CO3-NaHCO3.This ECL response is in the range of 1.0×10-8~1.4×10-5g/ml pefloxacin with a detection limit of 8.0×10-9g/ml.The relative standard deviation is 2.5%.This method was used to determine pefloxacin in samples with satisfactory results.展开更多
文摘A simple and sensitive flow injection method is presented for the determination of histidine based on its enhancement of electrogenerated chemiluminescence (ECL) of luminol. After optimization of the experimental parameters, the working range for histidine was in 1.0 x 10-6 to 1.0 x 10 -3 mol/L with a detection limit (S/N = 3) of 0.56 mmol/L. The relative standard deviation was 1.6% for 11 measurements of 5 x 10 5 mol/L histidine solution. The proposed method has been successfully applied to the determination of histidine in real pharmaceutical preparation.
基金supported by the National Natural Science Foundation of China(No.20805028)
文摘A novel electrogenerated chemiluminescence(ECL)sensor for the determination of metoclopramide was developed by employing ruthenium complex as an ECL signal producer and an ordered mesoporous carbon(OMC)material as modified material.The ECL sensor was fabricated by adsorption ruthenium complex into a mixture of OMC and Nafion,which showed good electrochemical and ECL behaviors.It was found that the ECL intensity of the sensor fabricated was greatly enhanced in the presence of metoclopramide.Based on this finding,a highly sensitive and reproducible ECL method was developed for the determination of metoclopramide.The result showed that the ECL intensity was linear with the concentration of metoclopramide in the range from 1.0×10-10 to 5.0×10-7M and the detection limit was 3×10-11M.The ECL sensor exhibited a long-term stability and a fine reproducibility with relative standard deviation of 1.0 % for 1.0×10-10M metoclopramide in 18 continuous determinations.The developed method has been applied to the determination of metoclopramide in tablet samples with satisfactory results.
文摘Electrogenerated chemiluminescence(electrochemiluminescence, ECL) generates species at electrode surfaces, which undergoes electron-transfer reactions and forms excited states to emit light. It has become a very powerful analytical technique and has been widely used in such as clinical testing, biowarfare agent detection, and pharmaceutical analysis. This review focuses on the current trends of molecular recognition-based biosensing methods for pharmaceutical analysis since 2010. It introduces a background of ECL and presents the recent ECL developments in ECL immunoassay(ECLIA), immunosensors, enzyme-based biosensors, aptamer-based biosensors, and molecularly imprinted polymers(MIP)-based sensors. At last, the future perspective for these analytical methods is briefly discussed.
文摘A new flow injection electrogenerated chemiluminescence(ECL)method for the determination of pefloxacin was developed.The method is based on the sensitiving effect of pefloxacin on the weak ECL signal of electrochemical oxidation of luminol on the platinum flake electrode in the medium of 0.05mol/L Na2CO3-NaHCO3.This ECL response is in the range of 1.0×10-8~1.4×10-5g/ml pefloxacin with a detection limit of 8.0×10-9g/ml.The relative standard deviation is 2.5%.This method was used to determine pefloxacin in samples with satisfactory results.