Metal-coated fiber Bragg grating(FBG)temperature sensors were prepared via electroless nickel(EN)plating and tin electroplating methods on the surface of normal bare FBG.The surface morphologies of the metal-coate...Metal-coated fiber Bragg grating(FBG)temperature sensors were prepared via electroless nickel(EN)plating and tin electroplating methods on the surface of normal bare FBG.The surface morphologies of the metal-coated layers were observed under a metallographic microscope.The effects of pretreatment sequence,pH value of EN plating solution and current density of electroplating on the performance of the metal-coated layers were analyzed.Meanwhile, the Bragg wavelength shift induced by temperature was monitored by an optical spectrum analyzer.Sensitivity of the metal-coated FBG(MFBG)sensor was almost two times that of normal bare FBG sensor.The measuring temperature of the MFBG sensor could be up to 280℃,which was much better than that of conventional FBG sensor.展开更多
Flame Thermal Spray (FTS) coatings frequently show some porosity and reduced adherence to substrate, which affect its properties, especially its corrosion resistance. In this work, the corrosion resistance of AISI 101...Flame Thermal Spray (FTS) coatings frequently show some porosity and reduced adherence to substrate, which affect its properties, especially its corrosion resistance. In this work, the corrosion resistance of AISI 1018 carbon steel coated by different methods is compared: electroless nickel (EN) coating, NiCrFeBSi obtained by FTS, duplex coatings of an EN deposit on a layer of NiCrFeBSi obtained by FTS and a layer of NiCrFeBSi on an EN deposit. The coatings were characterized using optical microscopy and scanning electron microscopy techniques, EDS microprobe microanalysis, roughness as well as electrochemical polarization tests to obtain the corrosion rate. The results show the enhancement in the corrosion resistance in saline medium of the duplex coatings, especially of the EN coating on FTS layer.展开更多
We present a method for metal coating optical fiber and in-fiber Bragg grating. The technology process which is based on electroless plating and electroplating method is described in detail. The fiber is firstly coate...We present a method for metal coating optical fiber and in-fiber Bragg grating. The technology process which is based on electroless plating and electroplating method is described in detail. The fiber is firstly coated with a thin copper or nickel plate with electroless plating method. Then, a thicker nickel plate is coated on the surface of the conductive layer. Under the optimum conditions, the surfaces of chemical plating and electroplating coatings are all smooth and compact. There is no visible defect found in the cross-section. Using this two-step metallization method, the in-fiber Bragg grating can be well protected and its thermal sensitivity can be enhanced. After the metallization process, the fiber sensor is successfully embedded in the 42CrMo steel by brazing method. Thus a smart metal structure is achieved. The embedding results show that the plating method for metallization protection of in-fiber Bragg grating is effective.展开更多
基金the National Natural Science Foundation of China(No.60777038).
文摘Metal-coated fiber Bragg grating(FBG)temperature sensors were prepared via electroless nickel(EN)plating and tin electroplating methods on the surface of normal bare FBG.The surface morphologies of the metal-coated layers were observed under a metallographic microscope.The effects of pretreatment sequence,pH value of EN plating solution and current density of electroplating on the performance of the metal-coated layers were analyzed.Meanwhile, the Bragg wavelength shift induced by temperature was monitored by an optical spectrum analyzer.Sensitivity of the metal-coated FBG(MFBG)sensor was almost two times that of normal bare FBG sensor.The measuring temperature of the MFBG sensor could be up to 280℃,which was much better than that of conventional FBG sensor.
文摘Flame Thermal Spray (FTS) coatings frequently show some porosity and reduced adherence to substrate, which affect its properties, especially its corrosion resistance. In this work, the corrosion resistance of AISI 1018 carbon steel coated by different methods is compared: electroless nickel (EN) coating, NiCrFeBSi obtained by FTS, duplex coatings of an EN deposit on a layer of NiCrFeBSi obtained by FTS and a layer of NiCrFeBSi on an EN deposit. The coatings were characterized using optical microscopy and scanning electron microscopy techniques, EDS microprobe microanalysis, roughness as well as electrochemical polarization tests to obtain the corrosion rate. The results show the enhancement in the corrosion resistance in saline medium of the duplex coatings, especially of the EN coating on FTS layer.
基金supported by the National "973" Foundation Pre-Program of China (No. 2005CCA04300)the National Natural Science Foundation of China(No. 60844005)+1 种基金the Natural Science foundation of Jiangxi province (No. 2008GQC0013)the StateKey Lab of Advanced Welding Production Technology,Harbin Institute of Technology
文摘We present a method for metal coating optical fiber and in-fiber Bragg grating. The technology process which is based on electroless plating and electroplating method is described in detail. The fiber is firstly coated with a thin copper or nickel plate with electroless plating method. Then, a thicker nickel plate is coated on the surface of the conductive layer. Under the optimum conditions, the surfaces of chemical plating and electroplating coatings are all smooth and compact. There is no visible defect found in the cross-section. Using this two-step metallization method, the in-fiber Bragg grating can be well protected and its thermal sensitivity can be enhanced. After the metallization process, the fiber sensor is successfully embedded in the 42CrMo steel by brazing method. Thus a smart metal structure is achieved. The embedding results show that the plating method for metallization protection of in-fiber Bragg grating is effective.