At present, the main work of electron optical system CAD is solving equations and calculating mumerical values. However, the design perhaps needs more inference and expertise than numerical calculations because the st...At present, the main work of electron optical system CAD is solving equations and calculating mumerical values. However, the design perhaps needs more inference and expertise than numerical calculations because the structure of electron lens system is complicated. In this paper, a primary expert system is applied to design the electron lens system intelligently. This expert system is combined with SEU-3D program which is used to simulate the electron optical system to optimize the electron lens systems. In spite of this, the expert system which is established in this paper can also be used to diagnose the electron lens system. Although the knowledge base is small and rules are not abundant, this paper has used this system to obtain some very useful results. The initial success with this system suggests that further work need to be done whether more rules and knowledge will be added to extend the ability of expert system.展开更多
Cases report Case 1: A 50-year-old man was injuried by iron filings on his left eye. He was admitted to our hospital on Feb. 3, 1987. On examination, his visual acuity was 20/15 OD and 20/500 OS. Left eye: The cornea ...Cases report Case 1: A 50-year-old man was injuried by iron filings on his left eye. He was admitted to our hospital on Feb. 3, 1987. On examination, his visual acuity was 20/15 OD and 20/500 OS. Left eye: The cornea was clear, the anterior chamber depth was 3 CT, tyndall(-). Iris pattern is clear, pupil was 3.5×3.5mm. Dilated pupil examination: There were scattered brown-yellow ironrust under anterior capsule and the lens cortex had become totally opaque. Nuclear, posterior capsule and fundus can't be ...展开更多
文摘At present, the main work of electron optical system CAD is solving equations and calculating mumerical values. However, the design perhaps needs more inference and expertise than numerical calculations because the structure of electron lens system is complicated. In this paper, a primary expert system is applied to design the electron lens system intelligently. This expert system is combined with SEU-3D program which is used to simulate the electron optical system to optimize the electron lens systems. In spite of this, the expert system which is established in this paper can also be used to diagnose the electron lens system. Although the knowledge base is small and rules are not abundant, this paper has used this system to obtain some very useful results. The initial success with this system suggests that further work need to be done whether more rules and knowledge will be added to extend the ability of expert system.
文摘Cases report Case 1: A 50-year-old man was injuried by iron filings on his left eye. He was admitted to our hospital on Feb. 3, 1987. On examination, his visual acuity was 20/15 OD and 20/500 OS. Left eye: The cornea was clear, the anterior chamber depth was 3 CT, tyndall(-). Iris pattern is clear, pupil was 3.5×3.5mm. Dilated pupil examination: There were scattered brown-yellow ironrust under anterior capsule and the lens cortex had become totally opaque. Nuclear, posterior capsule and fundus can't be ...