期刊文献+
共找到17篇文章
< 1 >
每页显示 20 50 100
Factors Influencing the Electron Yield of Needle-Ring Pulsed Corona Discharge Electron Source for Negative Ion Mobility Spectrometer 被引量:4
1
作者 刘欣 李胜利 李铭书 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第12期1215-1220,共6页
A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron... A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron source. Simulation with Ansoft Maxwell 12 is carried out to analyze the electric field distribution within the IMS, and to offer the basis and foundation for analyzing the measurement results. The measurement results of the quantities of electrons show that when the drift electric field strength and the ring inner diameter rise, both the number of ef- fective electrons and the effective electron rate are increased. When the discharge voltage becomes stronger, the number of effective electrons goes up while the effective electron rate goes down. In light of the simulation results, mechanisms underlying the effects of drift electric field strength, ring inner diameter, and discharge voltage on the effective electron number and effective electron rate are discussed. These will make great sense for designing negative ion mode IMS using the needle-ring pulsed corona discharge as the electron source. 展开更多
关键词 ion mobility spectrometer electron source pulsed corona discharge effectiveelectrons simulation
下载PDF
Passive magnetic shielded spin polarized electron source with optical electron polarimeter
2
作者 丁海兵 庞文宁 +1 位作者 刘义保 尚仁成 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第1期51-57,共7页
A new GaAs(100) spin polarized electron source with an optical polarimeter, which is employed in the field of polarized electron and gas atom collision, is presented in detail. The apparatus is passive-magnetic-shie... A new GaAs(100) spin polarized electron source with an optical polarimeter, which is employed in the field of polarized electron and gas atom collision, is presented in detail. The apparatus is passive-magnetic-shielded by a box and a cylinder made of nickel-iron-molybdenum soft magnetic alloy without Helmholtz coil arrangement. And a uniformly distributed residual magnetic field of less than 5 × 10^-7T is obtained near the collision area. The spin polarized electron beam is transmitted and focused onto collision point from photocathode by a set of electron optics with more than 25% transmission 95 cm distance through an 1 mm diameter aperture. Construction and operation of the apparatus, such as vacuum and magnetic shielding system, photocathode, laser optics, electron optics and polarimeter are discussed. The polarization of the spin polarized electron beam is determined to be 30.8 ±3.5% measured with a He optical polarimeter. 展开更多
关键词 spin polarized electron source optical electron polarimeter polarization
下载PDF
Focused electron beam transport through a long narrow metal tube at elevated pressures in the forevacuum range
3
作者 Ilya BAKEEV Kirill KARPOV +2 位作者 Aleksandr KLIMOV Efim OKS Aleksey ZENIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期128-134,共7页
We present here our investigations of the features of focused electron beam transport in free space at elevated pressures of a few pascals.We have explored the effect of the beam accelerating voltage,operating gas pre... We present here our investigations of the features of focused electron beam transport in free space at elevated pressures of a few pascals.We have explored the effect of the beam accelerating voltage,operating gas pressure,and magnetic focusing upon the trajectory of beam electrons in the crossover region,in particular on the beam convergence and divergence angles.It is shown that for the forevacuum pressure range of 2-5 Pa explored,a distinctive feature of the propagation of a focused electron beam with a current of up to 20 mA at an accelerating voltage of 10-20 kV is the difference in the angles of convergence(before the focus)and divergence(after the focus).Whereas at a low pressure of 2 Pa the divergence angle is smaller than the convergence angle,as the pressure increases the divergence angle increases and for pressures greater than 5 Pa the divergence angle is greater than the convergence angle.The results obtained were used in experiments on electron beam transport through a long narrow metal tube with a diameter of 5.8-9.2 mm and length of 10-30 cm.We show that for a 30 cm long tube of 7.5 mm diameter,the focused beam transmission can exceed 70%. 展开更多
关键词 focused electron beam plasma electron source forevacuum pressure range long metal tube
下载PDF
Mechanical Analysis and Measurements of a Multicomponent NbTi/Cu Superconducting Magnets Structure for the Fully Superconducting Electron Cyclotron Resonance Ion Source 被引量:1
4
作者 关明智 胡强 +6 位作者 高配峰 王省哲 杨通军 吴巍 辛灿杰 吴北民 马力祯 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第5期135-139,共5页
A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconductin... A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconducting solenoids (Nb-Ti/Cu) and six superconducting sextupoles (Nb-Ti/Cu). Different from the conventional supercon- ducting ECR magnetic structure, the SEC17AL Ⅱ includes three superconducting solenoid coils' that are located inside the superconducting sextupoles. The SECRAL Ⅱ can significantly reduce the interaction forces between the sextupole and the solenoids, and the magnets can also be more compact in size. For this multi-component SECRAL Ⅱ generating its self field of -8 T and being often exposed to the high self field, the mechanical analysis has become the main issue to keep their stress at 〈200 MPa on coils. The analytical and experimental results in mechanics are presented in the SECRAL Ⅱ structure. To improve the accuracy and efficiency of analysis, according to the composite rule of micromechanics, the equivalent uniform windings are used to simulate the epoxy-impregnated Nb-Ti/Cu coils. In addition, using low temperature strain gauges and a wireless fast strain acquisition system, a fundamental experiment on the based on our analysis, the stresses and deformations optimized. strains developments of a sextupole is reported. Finally, for its assembly of each SECRAL Ⅱ coil will be further 展开更多
关键词 of on IS as NBTI Mechanical Analysis and Measurements of a Multicomponent NbTi/Cu Superconducting Magnets Structure for the Fully Superconducting electron Cyclotron Resonance Ion source in for Cu
下载PDF
Study of electron-extraction characteristics of an inductively coupled radio-frequency plasma neutralizer 被引量:2
5
作者 贺建武 马隆飞 +3 位作者 薛森文 章楚 段俐 康琦 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第2期122-127,共6页
Inductively coupled radio-frequency(RF) plasma neutralizer(RPN) is an insert-free device that can be employed as an electron source in electric propulsion applications.Electron-extraction characteristics of the RP... Inductively coupled radio-frequency(RF) plasma neutralizer(RPN) is an insert-free device that can be employed as an electron source in electric propulsion applications.Electron-extraction characteristics of the RPN are related to the bulk plasma parameters and the device's geometry.Therefore,the effects of different electron-extraction apertures and operational parameters upon the electron-extraction characteristics are investigated according to the global nonambipolar flow and sheath model.Moreover,these models can also be used to explain why the electron-extraction characteristics of the RPN strongly depend upon the formation of the anode spot.During the experimental study,two types of anode spots are observed.Each of them has unique characteristics of electron extraction.Moreover,the hysteresis of an anode spot is observed by changing the xenon volume-flow rates or the bias voltages.In addition,the rapid ignited method,gas-utilization factor,electron-extraction cost and other factors that need to be considered in the design of the RPN are also discussed. 展开更多
关键词 electron source plasma cathode RF neutralizer RF plasma anode spot
下载PDF
The research progress of an E//B neutral particle analyzer
6
作者 马龙 屈玉凡 +12 位作者 罗圆 谢德豪 汪彦熹 王硕 曲国峰 任培培 罗小兵 刘星泉 韩纪锋 Roy WADA 林炜平 臧临阁 朱敬军 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期10-16,共7页
An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of ... An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of fast ions in the HL-2A/3 tokamak.The E//B NPA contains three main units,i.e.the stripping unit,the analyzing unit and the detection unit.A gas stripping chamber was adopted as the stripping unit.The results of the simulations and beam tests for the stripping chamber are presented.Parallel electric and magnetic fields provided by a NdFeB permanent magnet and two parallel electric plates were designed and constructed for the analyzing unit.The calibration of the magnetic and electric fields was performed using a 50 kV electron cyclotron resonance ion source(ECRIS)platform.The detection unit consists of 32lutetium-yttrium oxyorthosilicate(LYSO)detector modules arranged in two rows.The response functions ofα,hydrogen ions(H^(+),H_(2)^(+)and H_(3)^(+))andγfor a detector module were measured with^(241)Am,^(137)Cs and^(152)Eu sources together with the 50 kV ECRIS platform.The overall results indicate that the designed E//B NPA device is capable of measuring the intensity of neutral hydrogen and deuteron atoms with energy higher than 20 keV. 展开更多
关键词 E//B neutral particle analyzer gas stripping lutetium-yttrium oxyorthosilicate electron cyclotron resonance ion source platform
下载PDF
Practical 2.45-GHz microwave-driven Cs-free Hˉ ion source developed at Peking University 被引量:2
7
作者 张滔 彭士香 +8 位作者 武文斌 任海涛 张景丰 温佳美 马腾昊 蒋耀湘 孙江 郭之虞 陈佳洱 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第10期477-483,共7页
A practical 2.45-GHz microwave-driven Cs-free H^- source was improved based on the experimental H^- source at Peking University(PKU). Several structural improvements were implemented to meet the practical requiremen... A practical 2.45-GHz microwave-driven Cs-free H^- source was improved based on the experimental H^- source at Peking University(PKU). Several structural improvements were implemented to meet the practical requirements of Xi'an Proton Application Facility(XiPaf). Firstly, the plasma chamber size was optimized to enhance the plasma intensity and stability. Secondly, the filter magnetic field and electron deflecting magnetic field were enhanced to reduce co-extracted electrons. Thirdly, a new two-electrode extraction system with farther electrode gap and enhanced water cooling ability to diminish spark and sputter during beam extraction was applied. At last, the direct H^- current measuring method was adopted by the arrangement of a new pair of bending magnets before Faraday cup(FC) to remove residual electrons. With these improvements, electron cyclotron resonance(ECR) magnetic field optimization experiments and operation parameter variation experiments were carried out on the H^- ion source and a maximum 8.5-mA pure H^- beam was extracted at 50 kV with the time structure of 100 Hz/0.3 ms. The root-mean-square(RMS) emittance of the beam is 0.25 Π·mm·mrad. This improved H^- source and extraction system were maintenance-free for more than 200 hours in operation. 展开更多
关键词 electron cyclotron resonance (ECR) ion source hydrogen plasma negative ion beam plasma application
下载PDF
Development of plasma sources for Dipole Research EXperiment(DREX)
8
作者 肖青梅 王志斌 +6 位作者 鄂鹏 王晓钢 肖池阶 任洋 吉瀚涛 毛傲华 李立毅 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第5期15-20,共6页
Dipole Research EXperiment(DREX) is a new terrella device as part of the Space Plasma Environment Research Facility(SPERF) for laboratory studies of space physics relevant to the inner magnetospheric plasmas. Adeq... Dipole Research EXperiment(DREX) is a new terrella device as part of the Space Plasma Environment Research Facility(SPERF) for laboratory studies of space physics relevant to the inner magnetospheric plasmas. Adequate plasma sources are very important for DREX to achieve its scientific goals. According to different research requirements, there are two density regimes for DREX. The low density regime will be achieved by an electron cyclotron resonance(ECR) system for the ‘whistler/chorus' wave investigation, while the high density regime will be achieved by biased cold cathode discharge for the desired ‘Alfvén' wave study. The parameters of ‘whistler/chorus' waves and ‘Alfvén' waves are determined by the scaling law between space and laboratory plasmas in the current device. In this paper, the initial design of these two plasma sources for DREX is described. Focus is placed on the chosen frequency and operation mode of the ECR system which will produce relatively low density ‘artificial radiation belt' plasmas and the seed electrons, followed by the design of biased cold cathode discharge to generate plasma with high density. 展开更多
关键词 Dipole Research EXperiment(DREX) plasma sources electron cyclotron resonance(ECR) bias cold cathode discharge wave particle interaction
下载PDF
Structure and Mechanical Properties of CrN Thick Films Deposited by High-Rate Medium-Frequency Magnetron Sputtering 被引量:1
9
作者 刘传胜 王红军 +4 位作者 周霖 张瑞 田灿鑫 黎明 付德君 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第4期442-446,共5页
A home-made electron source assisted medium-frequency (MF) magnetron sputter- ing system was used to deposit thick CrN films on silicon and tungsten carbide substrates at various nitrogen flow rates with a fixed tot... A home-made electron source assisted medium-frequency (MF) magnetron sputter- ing system was used to deposit thick CrN films on silicon and tungsten carbide substrates at various nitrogen flow rates with a fixed total pressure (0.3 Pa) and MF power (11.2 kW). Result from scanning electron microscopy showed that the deposited CrN films have clear columnar struc- ture, and X-ray diffraction revealed a preferred orientation of CrN (200) for samples prepared at a rate of N2/(N2+Ar) below 60%, whereas those prepared at higher N2/(N2+Ar) rate are dom- inated by Cr2N. Deposition rates up to 12.5 μm/h were achieved and the hardness of the CrN coatings were in a range of 11 GPa to 18 GPa. 展开更多
关键词 CRN electron source medium frequency magnetron sputtering STRUCTURE HARDNESS
下载PDF
Three dimensional photovoltaic fibers for wearable energy harvesting and conversion 被引量:2
10
作者 Ming Peng Bin Dong Dechun Zou 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2018年第3期611-621,共11页
As the development of smart electronics, self-powered sources have been attracting increasing attention.This review summarizes research progress of photovoltaic fibers and their integrated power sources with multi-sta... As the development of smart electronics, self-powered sources have been attracting increasing attention.This review summarizes research progress of photovoltaic fibers and their integrated power sources with multi-stage energy conversion. Recent development of three dimensional photovoltaic fibers is glanced with special attention to structure design and materials of typical photovoltaic types(inorganic, organic,dye/quantum dot sensitized and perovskite solar cells). The application of carbon materials in fiber energy is focused as it is a hot topic recently. The hybrid energy systems based on fiber solar cells and fiber supercapacitors, fiber batteries and fiber nanogenerators are summarized together with hybrid energy textiles. This review provides a macroscopic view of novel energy fibers and will attract research interest in flexible/wearable fiber electronics and energy textiles. 展开更多
关键词 Photovoltaic fibers Smart electronics Self-powered sources Energy textiles Three dimension
下载PDF
Research on modeling of heat source for electron beam welding fusion-solidification zone 被引量:3
11
作者 Wang Yajun Fu Pengfei +2 位作者 Guan Yongjun Lu Zhijun Wei Yintao 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2013年第1期217-223,共7页
In this paper, the common heat source model of point and linear heat source in the numerical simulation of electron beam welding (EBW) were summarized and introduced. The combined point-linear heat source model was ... In this paper, the common heat source model of point and linear heat source in the numerical simulation of electron beam welding (EBW) were summarized and introduced. The combined point-linear heat source model was brought forward and to simulate the welding temperature fields of EBW and predicting the weld shape. The model parameters were put forward and regulated in the combined model, which included the ratio of point heat source to linear heat source Qpr and the distribution of linear heat source Lr. Based on the combined model, the welding temperature fields of EBW were investigated. The results show that the predicted weld shapes are conformable to those of the actual, the temperature fields are reasonable and correct by simulating with combined point-linear heat source model and the typical weld shapes are gained. 展开更多
关键词 electron beam welding (EBW) Fusion-solidification zone Heat source model Temperature fields Weld shape
原文传递
Study of temporal evolution of emission spectrum in a steeply rising submillimeter burst
12
作者 Jian-Ping Li Ai-Hua Zhou Xin-Dong Wang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2016年第1期67-72,共6页
The temporal evolution of a spectrum during a steeply rising submillimeter(THz) burst that occurred on 2003 November 2 was investigated in detail for the first time.Observations show that the flux density of the THz... The temporal evolution of a spectrum during a steeply rising submillimeter(THz) burst that occurred on 2003 November 2 was investigated in detail for the first time.Observations show that the flux density of the THz spectrum increased steeply with frequency above 200 GHz.Their average rising rates reached a value of 235 sfu GHz^(-1)(corresponding to spectral index α of 4.8) during the burst.The flux densities reached about 4 000 and 70 000 sfu at 212 and 405 GHz at the maximum phase,respectively.The emissions at 405 GHz maintained such a continuous high level that they largely exceeded the peak values of the microwave(MW) spectra during the main phase.Our studies suggest that only energetic electrons with a low-energy cutoff of~ 1 MeV and number density of ~ 10~6-10~8 cm^(-3) can produce such a strong and steeply rising THz component via gyrosynchrotron radiation based on numerical simulations of burst spectra in the case of a nonuniform magnetic field.The electron number density N,derived from our numerical fits to the THz temporal evolution spectra,increased substantially from 8 ×10~6 to 4 × 10~8 cm^(-3),i.e.,the N value increased 50 times during the rise phase.During the decay phase it decreased to 7 ×10~7 cm^(-3),i.e.,it decreased by about five times from the maximum phase.The total electron number decreased an order of magnitude from the maximum phase to the decay phase.Nevertheless,the variation in amplitude of N is only about one time in the MW emission source during this burst,and the total electron number did not decrease but increased by about 20%during the decay phase.Interestingly,we find that the THz source radius decreased by about 24%while the MW source radius,on the contrary,increased by 28%during the decay phase. 展开更多
关键词 Sun: submillimeter burst -- Sun: energetic electrons -- Sun: radio source size
下载PDF
Understanding hydrogen plasma processes based on the diagnostic results of 2.45 GHz ECRIS at Peking University
13
作者 武文斌 任海涛 +7 位作者 彭士香 徐源 温佳美 孙江 张艾霖 张滔 张景丰 陈佳洱 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第9期310-317,共8页
Optical emission spectroscopy(OES), as a simple in situ method without disturbing the plasma, has been performed for the plasma diagnosis of a 2.45 GHz permanent magnet electron cyclotron resonance(PMECR) ion sour... Optical emission spectroscopy(OES), as a simple in situ method without disturbing the plasma, has been performed for the plasma diagnosis of a 2.45 GHz permanent magnet electron cyclotron resonance(PMECR) ion source at Peking University(PKU). A spectrum measurement platform has been set up with the quartz-chamber electron cyclotron resonance(ECR) ion source [Patent Number: ZL 201110026605.4] and experiments were carried out recently. The electron temperature and electron density inside the ECR plasma chamber have been measured with the method of line intensity ratio of noble gas. Hydrogen plasma processes inside the discharge chamber are discussed based on the diagnostic results. What is more, the superiority of the method of line intensity ratio of noble gas is indicated with a comparison to line intensity ratio of hydrogen. Details will be presented in this paper. 展开更多
关键词 electron cyclotron resonance(ECR) ion source hydrogen plasma plasma diagnosis optical emission spectroscopy
下载PDF
Radiography of a K_α X-ray source generated through ultrahigh picosecond laser–nanostructure target interaction 被引量:3
14
作者 王剑 赵宗清 +9 位作者 何卫华 朱斌 董克攻 吴玉迟 张天奎 高牛 周凯南 谢娜 周维民 谷渝秋 《Chinese Optics Letters》 SCIE EI CAS CSCD 2015年第3期18-21,共4页
Laser-driven ultrafast X-ray sources are widely used for diagnostic radiography. However, there is a large divergence of fast electrons when they are generated by an intense short-pulse laser interacting with a foil t... Laser-driven ultrafast X-ray sources are widely used for diagnostic radiography. However, there is a large divergence of fast electrons when they are generated by an intense short-pulse laser interacting with a foil target. We design a nanowire array target to achieve a more compact point X-ray source. Fast electrons are confined and guided by the nanowire array structure in order to generate a Kα source with a small spot size. In our work, the smallest measured source size is comparable to the laser spot size, while the conversion efficiency can reach 2.4 ×10^-4. 展开更多
关键词 Diagnostic radiography electron sources NANOWIRES X ray apparatus
原文传递
Application of polycapillary x ray lens to eliminate both the effect of x ray source size and scatter of the sample in laboratory tomography 被引量:2
15
作者 孙学鹏 刘志国 +6 位作者 孙天希 易龙涛 孙蔚渊 李坊佐 姜博文 马永忠 丁训良 《Chinese Optics Letters》 SCIE EI CAS CSCD 2015年第9期92-96,共5页
A tomography device based on a conventional laboratory x ray source, polycapillary parallel x ray lens (PPXRL), and polycapillary collimating x ray lens (PCXRL) is designed. The PPXRL can collect the divergent x r... A tomography device based on a conventional laboratory x ray source, polycapillary parallel x ray lens (PPXRL), and polycapillary collimating x ray lens (PCXRL) is designed. The PPXRL can collect the divergent x ray beam from the source and focus it into a quasi-parallel x ray beam with a divergence of 4.7 rarad. In the center of quasi-parallel x ray beam, there is a plateau region with an average gain in power density of 13.8 and a diameter of 630μm. The contrast of the image can be improved from 28.9% to 56.0% after adding the PCXRL between the sample and the detector. 展开更多
关键词 electron sources Optical instrument lenses TOMOGRAPHY X ray optics
原文传递
Multipacting saturation in parallel plate and micro-pulse electron gun
16
作者 廖浪 张猛 赵明华 《Chinese Physics C》 SCIE CAS CSCD 2015年第2期70-76,共7页
A novel parallel plate model is proposed that divides the electron cloud into three parts at saturation, and it is studied in detail using both an analytical approach and particle-in-cell (PIC) code simulations. As ... A novel parallel plate model is proposed that divides the electron cloud into three parts at saturation, and it is studied in detail using both an analytical approach and particle-in-cell (PIC) code simulations. As one part of the electron cloud, ribbons modes are suggested by tracking the trajectory of individual particles, and the aim of this mode form is to simplify the progress of the multipacting effect in the parallel plate so as to be eliminated by optimizing RF parameters. The micro-pulse electron gun (MPG) has demonstrated the potential to address the need for high peak and average current electron beams, hence studying the multipacting in MPG is essential. On the basis of studying multipacting in the parallel plate, it is clear that increasing the cavity voltage is of interest in yielding high quality beams in the gun. 展开更多
关键词 multipacting parallel plate micro-pulse electron gun electron source
原文传递
Relativistic electron acceleration by surface plasma waves excited with high intensity laser pulses
17
作者 X.M.Zhu R.Prasad +4 位作者 M.Swantusch B.Aur A.A.Andreev O.Willi M.Cerchez 《High Power Laser Science and Engineering》 SCIE CAS CSCD 2020年第2期40-49,共10页
The process of high energy electron acceleration along the surface of grating targets(GTs)that were irradiated by a relativistic,high-contrast laser pulse at an intensity I=2.5×10^20 W/cm^2 was studied.Our experi... The process of high energy electron acceleration along the surface of grating targets(GTs)that were irradiated by a relativistic,high-contrast laser pulse at an intensity I=2.5×10^20 W/cm^2 was studied.Our experimental results demonstrate that for a GT with a periodicity twice the laser wavelength,the surface electron flux is more intense for a laser incidence angle that is larger compared to the resonance angle predicted by the linear model.An electron beam with a peak charge of∼2.7 nC/sr,for electrons with energies>1.5 MeV,was measured.Numerical simulations carried out with parameters similar to the experimental conditions also show an enhanced electron flux at higher incidence angles depending on the preplasma scale length.A theoretical model that includes ponderomotive effects with more realistic initial preplasma conditions suggests that the laser-driven intensity and preformed plasma scale length are important for the acceleration process.The predictions closely match the experimental and computational results. 展开更多
关键词 laser-driven electron sources relativistic plasmas structured targets surface electrons
原文传递
上一页 1 下一页 到第