期刊文献+
共找到28篇文章
< 1 2 >
每页显示 20 50 100
Phase Transformation and Enhancing Electron Field Emission Properties in Microcrystalline Diamond Films Induced by Cu Ion Implantation and Rapid Annealing 被引量:1
1
作者 申艳艳 张一新 +5 位作者 祁婷 乔瑜 贾钰欣 黑鸿君 贺志勇 于盛旺 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第8期123-126,共4页
Cu ion implantation and subsequent rapid annealing at 500℃ in N2 result in low surface resistivity of 1.611 ohm/sq with high mobility of 290 cm2 V-1S-1 for microcrystalline diamond (MCD) films. Its electrical field... Cu ion implantation and subsequent rapid annealing at 500℃ in N2 result in low surface resistivity of 1.611 ohm/sq with high mobility of 290 cm2 V-1S-1 for microcrystalline diamond (MCD) films. Its electrical field emission behavior can be turned on at Eo = 2.6 V/μm, attaining a current density of 19.5μA/cm2 at an applied field of 3.5 V/#m. Field emission scanning electron microscopy combined with Raman and x-ray photoelectron mi- croscopy reveal that the formation of Cu nanoparticles in MCD films can catalytically convert the less conducting disorder/a-C phases into graphitic phases and can provoke the formation of nanographite in the films, forming conduction channels for electron transportation. 展开更多
关键词 CU of MCD Phase transformation and Enhancing electron Field Emission Properties in Microcrystalline Diamond Films Induced by Cu Ion Implantation and Rapid Annealing in by
下载PDF
Phase field model for electric-thermal coupled discharge breakdown of polyimide nanocomposites under high frequency electrical stress
2
作者 韩智云 李庆民 +3 位作者 李俊科 王梦溪 任瀚文 邹亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期114-124,共11页
In contrast to conventional transformers, power electronic transformers, as an integral component of new energy power system, are often subjected to high-frequency and transient electrical stresses, leading to heighte... In contrast to conventional transformers, power electronic transformers, as an integral component of new energy power system, are often subjected to high-frequency and transient electrical stresses, leading to heightened concerns regarding insulation failures. Meanwhile, the underlying mechanism behind discharge breakdown failure and nanofiller enhancement under high-frequency electrical stress remains unclear. An electric-thermal coupled discharge breakdown phase field model was constructed to study the evolution of the breakdown path in polyimide nanocomposite insulation subjected to high-frequency stress. The investigation focused on analyzing the effect of various factors, including frequency, temperature, and nanofiller shape, on the breakdown path of Polyimide(PI) composites. Additionally, it elucidated the enhancement mechanism of nano-modified composite insulation at the mesoscopic scale. The results indicated that with increasing frequency and temperature, the discharge breakdown path demonstrates accelerated development, accompanied by a gradual dominance of Joule heat energy. This enhancement is attributed to the dispersed electric field distribution and the hindering effect of the nanosheets. The research findings offer a theoretical foundation and methodological framework to inform the optimal design and performance management of new insulating materials utilized in high-frequency power equipment. 展开更多
关键词 dielectric discharge breakdown high frequency power electronic transformer polyimide nanocomposites phase field model
下载PDF
A Discrete State Event Driven Simulation based Losses Analysis for Multi-terminal Megawatt Power Electronic Transformer 被引量:5
3
作者 Jialin Zheng Zhengming Zhao +3 位作者 Bochen Shi Zhujun Yu Jiahe Ju Zhiqiang Fan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期275-284,共10页
At present,power electronic transformers(PETs)have been widely used in power systems.With the increase of PET capacity to the megawatt level.the problem of increased losses need to be taken seriously.As an important i... At present,power electronic transformers(PETs)have been widely used in power systems.With the increase of PET capacity to the megawatt level.the problem of increased losses need to be taken seriously.As an important indicator of power electronic device designing,losses have always been the focus of attention.At present,the losses are generally measured through experiments,but it takes a lot of time and is difficult to quantitatively analyze the internal distribution of PET losses.To solve the above problems,this article first qualitatively analyzes the losses of power electronic devices and proposes a loss calculation method based on pure simulation.This method uses the Discrete State Event Driven(DSED)modeling method to solve the problem of slow simulation speed of large-capacity power electronic devices and uses a loss calculation method that considers the operating conditions of the device to improve the calculation accuracy.For the PET prototype in this article,a losses model of the PET is established.The comparison of experimental and simulation results verifies the feasibility of the losses model.Then the losses composition of PET was analyzed to provide reference opinions for actual operation.It can help pre-analyze the losses distribution of PET,thereby providing a potential method for improving system efficiency. 展开更多
关键词 Power electronic transformer(PET) losses analysis efficiency losses branch model discrete-state event-driven
下载PDF
Research on power electronic transformer applied in AC/DC hybrid distribution networks 被引量:15
4
作者 Yiqun Miao Jieying Song +6 位作者 Haijun Liu Zhengang Lu Shufan Chen Chun Ding Tianzhi Cao Linhai Cai Yuzhong Gong 《Global Energy Interconnection》 2018年第3期396-403,共8页
The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/D... The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation. 展开更多
关键词 AC/DC hybrid distribution network Power electronic transformer(PET) Clamping double sub-module(CDSM) Energy router
下载PDF
Structured Microgrids (SμGs) and Flexible Electronic Large Power Transformers (FeLPTs) 被引量:4
5
作者 Don Tan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期255-263,共9页
Structured microgrids(SμGs)and Flexible electronic large power transformers(FeLPTs)are emerging as two essential technologies for renewable energy integration,flexible power transmission,and active control.SμGs prov... Structured microgrids(SμGs)and Flexible electronic large power transformers(FeLPTs)are emerging as two essential technologies for renewable energy integration,flexible power transmission,and active control.SμGs provide the integration of renewable energy and storage to balance the energy demand and supply as needed for a given system design.FeLPT’s flexibility for processing,control,and re-configurability offers the capability for flexible transmission for effective flow control and enable SμGs connectivity while still keeping multiscale system level control.Early adaptors for combined heat and power have demonstrated significant economic benefits while reducing environmental foot prints.They bring tremendous benefits to utility companies also.With storage and active control capabilities,a 300-percent increase in bulk transmission and distribution lines are possible without having to increase capacity.SμGs and FeLPTs will also enable the utility industry to be better prepared for the emerging large increase in base load demand from electric transportation and data centers.This is a win-win-win situation for the consumer,the utilities(grid operators),and the environment.SμGs and FeLPTs provide value in power substation,energy surety,reliability,resiliency,and security.It is also shown that the initial cost associated with SμG and FeLPTs deployment can be easily offset with reduced operating cost,which in turn reduces the total life-cycle cost by 33%to 67%. 展开更多
关键词 Terms-Structured microgrids flexible electronic large power transformers energy systems renewable integration grid modernization active control life-cycle cost
下载PDF
Dual-Timescale Control for Power Electronic Zigzag Transformer 被引量:1
6
作者 Chunpeng Zhang Zhengming Zhao 《CES Transactions on Electrical Machines and Systems》 2017年第3期315-321,共7页
Power electronic zigzag transformer is an attractive solution for the flexible interconnection of smart distribution networks.It is constituted by slow-response and low-precision thyristor converters and fast-response... Power electronic zigzag transformer is an attractive solution for the flexible interconnection of smart distribution networks.It is constituted by slow-response and low-precision thyristor converters and fast-response and high-accuracy voltage source converters.This paper models its primary circuit and addresses its basic operation mechanism.Then a dual-timescale control scheme is investigated to realize the coordinated regulation of both types of converter.A simulation case is established in PSCAD containing interconnected mid-voltage distribution networks.Simulations with poor-and well-matched control timescales are both carried out.And accordingly,the power flow controllability under these conditions is compared.When the shorter control timescale is no more than tenth of the longer one,the power electronic zigzag transformer will operate with satisfying performances. 展开更多
关键词 Power electronic transformer thyristor converter voltage source converter dual-timescale control flexible interconnection
下载PDF
Optical fiber-based power and data delivery system for high voltage electronic current transformer
7
作者 邱红辉 段雄英 邹积岩 《Journal of Shanghai University(English Edition)》 CAS 2008年第3期268-273,共6页
This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The desi... This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request. 展开更多
关键词 high voltage electronic current transformer (ECT) optical power supply delivery system photovoltaic powerconverters supervisory functions
下载PDF
Unbalanced Load Simulation of Electronic Power Transformer in Distribution System
8
作者 Wang Dan Mao Chengxiong +3 位作者 Lu Jiming Fan Shu Cao Jiewei Wang Ben(Translated) 《Electricity》 2006年第1期38-43,共6页
A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads... A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads. The simple and appropriate control scheme was developed through analyzing the system requirements of the primary side and the load requirements of the secondary side. In the input section, a dual-loop control in synchronous rotating d-q coordinates was introduced, and in the output section, a dual-loop control based on instantaneous output voltage was used. Load characteristics of EPT were investigated by using Matlab/Simulink software. Simulation results showed that, with the proposed control scheme, the EPT has good performances and the sinusoidal input current and constant output voltage can be realized under both balanced and unbalanced loads. 展开更多
关键词 electronic power transformer distribution system unbalanced load
下载PDF
ELECTRON MICROSCOPIC OBSERVATION OF SIMIAN SARCOMA VIRUS TRANSFORMED NIH 3T3 CELLS IN VITRO
9
作者 田竟生 苏树芸 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 1989年第2期16-18,共3页
For electronic microscopic observation, we found SSV-transformed NIH 3T3 cells were different from non-transformed cells. In SSV-transformed NIH 3T3 cells nuclei cytoplasma ratio was increased and in cytoplasma the ri... For electronic microscopic observation, we found SSV-transformed NIH 3T3 cells were different from non-transformed cells. In SSV-transformed NIH 3T3 cells nuclei cytoplasma ratio was increased and in cytoplasma the ribosomes (polyribosomes were attached to the swollen rough endoplasmic reticulum. It was likely that ribosomes were lined together functionally and structionally to produce specific protein (PDGF-like protein). 展开更多
关键词 NIH electron MICROSCOPIC OBSERVATION OF SIMIAN SARCOMA VIRUS TRANSFORMED NIH 3T3 CELLS IN VITRO RER
下载PDF
Towards a (More) Electronic Transmission and Distribution (eT&D)
10
作者 Don Tan Damir Novosel 《CES Transactions on Electrical Machines and Systems》 2017年第1期15-25,共11页
The challenges and the path towards a(more)electronic transmission and distribution(eT&D)is presented in this paper.The challenges are first identified together with key stakeholders in the drive for grid moderniz... The challenges and the path towards a(more)electronic transmission and distribution(eT&D)is presented in this paper.The challenges are first identified together with key stakeholders in the drive for grid modernization.A fundamental question is then asked about the investment priority.Six basic characteristics are reviewed,leading to the composition of structured microgrids as the basic functional cell of a modern grid.One example of fractal radial structure and one fractal meshed structure are presented.The likely evolution path is then proposed together with basic technology sets.Specific foundation technologies are discussed in detail,including adiabatic power conversion,3MC technology,medium voltage conversion,distribution-level electronic power transformer and FACTs hardware integration,and back-to-back converters as a universal interconnect element.The rapidly emerging on-wire sensing technology is also discussed.It is pointed out that the distribution-level large electronic power transformer will provide a key component to enable hybrid ac/dc grid flow control and ancillary support for a flexible electronic transmission and distribution(eT&D)systems. 展开更多
关键词 All things grid connected electric power systems electronic transmission&distribution(eT&D) energy solutions flexible electronic transmission systems(FETS) grid modernization large electronic power transformers 3MC converters renewable energy.
下载PDF
Relativistic Reduction of the Electron-Nucleus Force in Bohr’s Hydrogen Atom and the Time of Electron Transition between the Neighbouring Quantum Energy Levels
11
作者 Stanisław Olszewski 《Journal of Modern Physics》 2020年第6期944-951,共8页
The aim of the paper is to get an insight into the time interval of electron emission done between two neighbouring energy levels of the hydrogen atom. To this purpose, in the first step, the formulae of the special r... The aim of the paper is to get an insight into the time interval of electron emission done between two neighbouring energy levels of the hydrogen atom. To this purpose, in the first step, the formulae of the special relativity are applied to demonstrate the conditions which can annihilate the electrostatic force acting between the nucleus and electron in the atom. This result is obtained when a suitable electron speed entering the Lorentz transformation is combined with the strength of the magnetic field acting normally to the electron orbit in the atom. In the next step, the Maxwell equation characterizing the electromotive force is applied to calculate the time interval connected with the change of the magnetic field necessary to produce the force. It is shown that the time interval obtained from the Maxwell equation, multiplied by the energy change of two neighbouring energy levels considered in the atom, does satisfy the Joule-Lenz formula associated with the quantum electron energy emission rate between the levels. 展开更多
关键词 Hydrogen Atom The Bohr Model Lorentz transformation Done with the Aid of the electron Orbital Speed Maxwell Equation Applied to Calculate the Time Interval of electron Transitions between Two Quantum Energy Levels Comparison with the Joule-Lenz Law for Energy Emission
下载PDF
Low-Frequency Stability Analysis of Power Electronic Traction Transformer Based Train-Network System
12
作者 Yi Hong Yang Li +1 位作者 Zhikang Shuai Hanyu Yang 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第4期1608-1617,共10页
Power electronic traction transformers(PETTs)will be increasingly applied to locomotives in the future for their small volume and light weight.However,similar to conventional trains,PETTs behave as constant power load... Power electronic traction transformers(PETTs)will be increasingly applied to locomotives in the future for their small volume and light weight.However,similar to conventional trains,PETTs behave as constant power loads and may cause low-frequency oscillation(LFO)to the train-network system.To solve this issue,a mathematical model of the PETT is firstly proposed and verified based on the extended describing function(EDF)method in this paper.In the proposed model,the LLC converter is simplified to an equivalent circuit consisting of a capacitor and a resistor in parallel.It is further demonstrated that the model can apply to various LLC converters with different topologies and controls.Particularly,when the parameter differences between cells are not obvious,the PETT can be simplified to a single-phase rectifier(i.e.,conventional train)by equivalent transformation.Based on the model of PETT,the system low-frequency stability and influential factors are analyzed by using the generalized Nyquist criterion.Lastly,the correctness and accuracy of theoretical analyses are validated by off-line and hardware-in-the-loop simulation results. 展开更多
关键词 Extended describing function method impedance model low-frequency oscillation power electronic traction transformer train-network system
原文传递
Power flow calculation for a distribution system with multi-port PETs:an improved AC-DC decoupling iterative method 被引量:5
13
作者 Hang Yin Qiang Li +3 位作者 Youbo Liu Xianglong Liu Yue Xiang Junyong Liu 《Global Energy Interconnection》 2020年第4期313-323,共11页
Recently,power electronic transformers(PETs)have received widespread attention owing to their flexible networking,diverse operating modes,and abundant control objects.In this study,we established a steady-state model ... Recently,power electronic transformers(PETs)have received widespread attention owing to their flexible networking,diverse operating modes,and abundant control objects.In this study,we established a steady-state model of PETs and applied it to the power flow calculation of AC-DC hybrid systems with PETs,considering the topology,power balance,loss,and control characteristics of multi-port PETs.To address new problems caused by the introduction of the PET port and control equations to the power flow calculation,this study proposes an iterative method of AC-DC mixed power flow decoupling based on step optimization,which can achieve AC-DC decoupling and effectively improve convergence.The results show that the proposed algorithm improves the iterative method and overcomes the overcorrection and initial value sensitivity problems of conventional iterative algorithms. 展开更多
关键词 Power electronic transformers AC-DC distribution systems AC-DC mixed power flow algorithm
下载PDF
Influence of Repetitive Impulse Waveforms on Surface Discharge Characteristics and Insulation Life for Polyimide Film
14
作者 Zhiyun Han Qingmin Li +3 位作者 Yujin Guo Tao Liu Guojing Dong Hanwen Ren 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第2期746-755,共10页
Accelerated insulation aging problems under high frequency repetitive impulses in power electronic transformers are drawing more and more attention in modern power systems. Partial discharge (PD) characteristics inclu... Accelerated insulation aging problems under high frequency repetitive impulses in power electronic transformers are drawing more and more attention in modern power systems. Partial discharge (PD) characteristics including discharge inception voltage, phase distribution and statistical characteristics on polyimide (PI) surface under different impulse waveforms and the insulation life of PI films are studied in this paper. We carry out experiments based on PD and insulation lifetime test systems, using five different types of repetitive impulses, including three bipolar waves and two unipolar waves. The experimental results show that there is little variation in discharge inception voltage under different waveforms, but great variation in phase distribution and statistical characteristics of PD. In addition, insulation life is approximately the same under different waveforms with the same polarity, and the aging rate under bipolar waveforms is larger than that under unipolar waveforms. We explain the differences between the bipolar and unipolar waveforms on insulation life, which can be concluded that the surface charge under unipolar waveform accumulates more significnatly compared with bipolar waveform and decreases the electric filed strength in discharging the air gap and inhibits surface discharge from occurring. 展开更多
关键词 Insulation life polyimide film power electronic transformer repetitive impulse surface discharge characteristics
原文传递
A novel low voltage ride through strategy for cascaded power electronic transformer 被引量:12
15
作者 Jiexiang Han Xiangping Kong +2 位作者 Peng Li Zhe Zhang Xianggen Yin 《Protection and Control of Modern Power Systems》 2019年第1期239-250,共12页
In view of the operating characteristics for voltage sags of AC side of the power electronic transformer(PET),a low-voltage ride through(LVRT)strategy adapted to bidirectional power exchange of PET is proposed for the... In view of the operating characteristics for voltage sags of AC side of the power electronic transformer(PET),a low-voltage ride through(LVRT)strategy adapted to bidirectional power exchange of PET is proposed for the purposes of maintaining the system stability,assisting the system voltage recovery and protecting PET safety.During the asymmetric voltage sag,the negative sequence current of PET is eliminated to ensure the symmetry of the injected current.According to the degree of positive sequence voltage sag,the reactive current injection is provided to assist in voltage recovery.According to the PET active power condition before the voltage sag,the level and direction of which are maintained as far as possible without exceeding the limit,for which the disturbance to the AC and DC grids is reduced.Finally,the effectiveness of the proposed LVRT strategy is verified by simulation model. 展开更多
关键词 Power electronic transformer Low-voltage ride through Control strategy Current instruction value
原文传递
A Critical Topology Review of Power Electronic Transformers:In View of Efficiency 被引量:5
16
作者 Guidong Zhang Jie Chen +1 位作者 Bo Zhang Yun Zhang 《Chinese Journal of Electrical Engineering》 CSCD 2018年第2期90-95,共6页
Design of power electronic transformers is a hot research topic and its efficiency improvement is a critical problem all over the world.It is also the largest barrier hindering the application of power electronic tran... Design of power electronic transformers is a hot research topic and its efficiency improvement is a critical problem all over the world.It is also the largest barrier hindering the application of power electronic transformers in industry.In this paper,the state of power electronic transformers is fully presented in terms of efficiency improvements.It is followed by the efficiency modeling of several typical topologies,and their detailed analysis and comparisons.Then,the corresponding industrial application scope of these topologies is presented,providing theoretical guidance for their industrial applications. 展开更多
关键词 Power electronic transformer TOPOLOGY EFFICIENCY MODELING
原文传递
A Three-phase Integrated Power Electronic Transformer with the Capability of DC Fault Clearance 被引量:2
17
作者 Yunfei Xu Guangfu Tang +2 位作者 Weiguo Li Guoliang Zhao Zhanfeng Deng 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第4期785-796,共12页
This paper presents a three-phase integrated power electronic transformer(PET)topology with the capability of DC fault clearance based on the investigation of PET topology.The proposed PET has three ports of high-volt... This paper presents a three-phase integrated power electronic transformer(PET)topology with the capability of DC fault clearance based on the investigation of PET topology.The proposed PET has three ports of high-voltage AC,high-voltage DC and low-voltage DC,which can achieve the flexible access of distributed energy resources・The power unit of the PET adopts a three-phase integrated topology,and the single-phase fluctuating power in the DC-link capacitor is reduced by a 4-port DC/DC converter,thereby reducing the capacitance of the DC-link capacitor;Meanwhile,the power unit uses the clamp double sub-module(CDSM)to allow for self-clearing of the short-circuit fault on the high-voltage DC side.Finally,this paper verifies the proposed PET through an EMT simulation and experimental prototype. 展开更多
关键词 DC fault clearing experimental verification power electronic transformer three phase integration
原文传递
Opposite Relationship between Orientation Selection and Texture Memory in the Deformed Electrical Steel Sheets during α→γ→α Transformation 被引量:2
18
作者 Louwen Zhang Ping Yang Weimin Mao 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2017年第12期1522-1530,共9页
The undesired {111} texture component for the magnetic properties mainly exists in the sheets of electrical steels by the conventional process, whereas the sheets with the non-{111} texture can be obtained by α→γ→... The undesired {111} texture component for the magnetic properties mainly exists in the sheets of electrical steels by the conventional process, whereas the sheets with the non-{111} texture can be obtained by α→γ→α transformation. In this paper, we mainly investigate the opposite relationship between orientation selection and texture memory in the deformed ultra-low carbon steel sheet during →→ transformation annealing. A 0.5 mm thick hot-rolled sheet is directly subjected to transformation. The result shows that the specific transformation textures are not possible to generate in the sheets without deformation. Besides, transformation annealing is conducted on the recrystallized sheets in hydrogen and vacuum, respectively. The near {100} and {110} grains have the growth advantage at the atmosphere/metal interface, and the initial ferrite textures are retained in vacuum. Cold-rolled sheets with different thicknesses are annealed for transformation in vacuum, hydrogen and nitrogen, respectively.The near {100} and {110} textures are still the preferential orientations at the atmosphere/metal interface. When the surface grains have sufficiently large growth advantage, the {111} grains developed by texture memory effect will be annexed. Otherwise, the {111} grains at the center layer of the sheets are hard to be replaced, and they are retained after α→γ→α transformation cycle. The results of deformed sheets annealed with different heating rates in hydrogen show that the growth of initial recrystallization grains has a great effect on variant selection. 展开更多
关键词 Orientation selection Texture memory Electrical steels α→γ→α transformation electron back-scatter diffraction
原文传递
Stress-Induced Martensitic Transformation of Zr_(50)Cu_(25)Ni_(10)Co_(15) Nanocrystals Embedded in an Amorphous Matrix
19
作者 W.H.Gao X.Y.Yi +3 位作者 X.L.Meng G.Song W.Cai L.C.Zhao 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2017年第3期276-280,共5页
The stress induced martensitic phase transformation of spherical ZrCu nanocrystals embedded in an amorphous matrix was studied in this paper. Microstructural observations revealed that the martensitic transformation o... The stress induced martensitic phase transformation of spherical ZrCu nanocrystals embedded in an amorphous matrix was studied in this paper. Microstructural observations revealed that the martensitic transformation of the nanocrystal was hindered by the surrounding amorphous coating. The existence of two-step transformation from the austenite phase(B2) to the base structure martensite(B19') and finally to the most stable superstructure martensite(Cm) was also demonstrated. The Cm martensite with(021) type I twinning symmetrically accommodation was surrounded by the B19' martensite with dislocation morphologies. 展开更多
关键词 Nanocrystals ZrCu Martensitic phase transformation Shape memory Transmission electron microscopy
原文传递
An approach for parameter estimation of combined CPPM and LFM radar signal 被引量:3
20
作者 Zhang Wei Xiong Ying +2 位作者 Wang Pei Wang Jun Tang Bin 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2013年第4期986-992,共7页
In this paper, the problem of parameter estimation of the combined radar signal adopting chaotic pulse position modulation (CPPM) and linear frequency modulation (LFM), which can be widely used in electronic count... In this paper, the problem of parameter estimation of the combined radar signal adopting chaotic pulse position modulation (CPPM) and linear frequency modulation (LFM), which can be widely used in electronic countermeasures, is addressed. An approach is proposed to estimate the initial frequency and chirp rate of the combined signal by exploiting the second-order cyclostationarity of the intra-pulse signal. In addition, under the condition of the equal pulse width, the pulse repetition interval (PRI) of the combined signal is predicted using the low-order Volterra adaptive filter. Simulations demonstrate that the proposed cyclic autocorrelation Hough transform (CHT) algorithm is theoretically tolerant to additive white Gaussian noise. When the value of signal noise to ratio (SNR) is less than 4 dB, it can still estimate the intra-pulse parameters well. When SNR = 3 dB, a good prediction of the PRI sequence can be achieved by the Volterra adaptive filter algorithm, even only 100 training samples. 展开更多
关键词 Chaotic pulse position modulation Combined radar signal Cyclic autocorrelation electronic countermeasures Hough transform Linear frequency modulation Volterra adaptive filter
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部