Modeling and Optimization of Solar Collector Design for the Improvement of Solar-Air Source Heat Pump Building Heating System
1
作者 Jiarui Wu Yuzhen Kang Junxiao Feng 《Energy Engineering》 EI 2023年第12期2783-2802,共20页
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr... To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance. 展开更多
关键词 Solar energy air source heat pump optimization model solar-air heat pump heating system
下载PDF
Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump
2
作者 Jingxiao Han Chuanzhao Zhang +5 位作者 LuWang ZengjunChang Qing Zhao Ying Shi JiaruiWu Xiangfei Kong 《Energy Engineering》 EI 2023年第9期1991-2011,共21页
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e... For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases. 展开更多
关键词 Electric heat storage solar energy air source heat pump multi-objective optimization method LOCH
下载PDF
Optimal capacity planning of combined renewable energy source-pumped storage and seawater desalination systems 被引量:4
3
作者 Boyu Liu Bowen Zhou +2 位作者 Dongsheng Yang Zhile Yang Mingjian Cui 《Global Energy Interconnection》 2019年第4期310-317,共8页
As water scarcity is becoming a growing threat to human development, finding effective solutions has become an urgent need. To make better use of water resources, seawater desalination and storage systems using renewa... As water scarcity is becoming a growing threat to human development, finding effective solutions has become an urgent need. To make better use of water resources, seawater desalination and storage systems using renewable energy sources(RES) are designed and implemented around the world. In this paper, an optimal capacity planning method for RES-pumped storage-seawater desalination(RES-PS-D) system is introduced. The configuration of the RES-PS-D system is clarified first, after which a cost-benefit analysis is performed using all cost and benefit components. A function for determining maximum economic benefits of the RES-PS-D system is then established, and the constraints are proposed based on various limitations. The mixed-integer linear programming algorithm is applied to solve the optimal function. A case study is introduced to validate the feasibility and effectiveness of the method. The conclusion shows that the strategy is suitable for solving the configuration optimization problem, and finally both merits and defects of the method are discussed. 展开更多
关键词 RENEWABLE energy source Seawater DESALINATION pumpED storage MAXIMUM ECONOMIC BENEFIT
下载PDF
Simulation of embedded heat exchangers of solar aided ground source heat pump system 被引量:1
4
作者 王芳 郑茂余 +1 位作者 邵俊鹏 李忠建 《Journal of Central South University》 SCIE EI CAS 2008年第S2期261-266,共6页
Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar ene... Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar energy collected in three seasons was stored in the soil by vertical U type soil exchangers. The heat abstracted by the ground-source heat pump and collected by the solar collector was employed to heating. Some of the soil heat exchangers were used to store solar energy in the soil so as to be used in next winter after this heating period; and the others were used to extract cooling energy directly in the soil by circulation pump for air conditioning in summer. After that solar energy began to be stored in the soil and ended before heating period. Three dimensional dynamic numerical simulations were built for soil and soil heat exchanger through finite element method. Simulation was done in different strata month by month. Variation and restoration of soil temperature were studied. Economy and reliability of long term SAGSHP system were revealed. It can be seen that soil temperature is about 3 ℃ higher than the original one after one year's running. It is beneficial for the system to operate for long period. 展开更多
关键词 SOLAR assisted ground source heat pump (ASGSHP) soil storage three DIMENSIONAL simulations HEATING and COOLING
下载PDF
Study on ground source heat pump system zoning and methods in the Northwest of Shandong Province 被引量:1
5
作者 YU Yi-qiang 《Journal of Groundwater Science and Engineering》 2018年第3期171-177,共7页
Based on the basic geology, hydrogeology, engineering geology, geothermal geology and ground source heat pump(GSHP) engineering of the work space, the thesis studies the local shallow geothermal energy. Three conditio... Based on the basic geology, hydrogeology, engineering geology, geothermal geology and ground source heat pump(GSHP) engineering of the work space, the thesis studies the local shallow geothermal energy. Three conditions of the attribute index for the suitability zoning of the northwest of Shandong are determined, namely, hydrodynamic condition, geological and hydrogeological condition and geological environment condition. The assessment result is that the total area of the suitable zone is 205.88 km^2, that of relative suitable zone, 1 407.76 km^2, and that of unsuitable zone, 286.8 km^2. The result conforms to the real development situation and provides experience for similar regions needed for selecting and assigning a value to suitability zoning of GSHP. 展开更多
关键词 Ground source heat pump NORTHWEST of SHANDONG Province Engineering GEOLOGY SUITABILITY ZONING
下载PDF
Research on single hole heat transfer power of ground source heat pump system 被引量:1
6
作者 ZHAO Fang-hua 《Journal of Groundwater Science and Engineering》 2018年第1期65-70,共6页
In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfe... In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfer power per meter in summer is 97.1% of the test data,and the average value accounts for 81.8%.The per meter heat power data through on-site thermal response test can provide references for designing engineering project and optimizing ground source heat pump system as these data do not vary greatly from the actual monitoring data. 展开更多
关键词 GROUND source HEAT pump Monitoring HEAT TRANSFER POWER Thermal response test
下载PDF
Variation characteristics of aquifer parameters induced by groundwater source heat pump operation under variable flow 被引量:5
7
作者 王松庆 张旭 《Journal of Central South University》 SCIE EI CAS 2011年第4期1272-1277,共6页
The variation characteristics of aquifer parameters,induced by groundwater source heat pump(GWSHP) operation under variable flow,were theoretically analyzed through a case study,in which the characteristics of buildin... The variation characteristics of aquifer parameters,induced by groundwater source heat pump(GWSHP) operation under variable flow,were theoretically analyzed through a case study,in which the characteristics of building air conditioning load were considered.The results,compared with the constant flow operation,indicate that the influence on the variations of porosity,hydraulic conductivity and confined water head is decreased by 48%,51% and 71%,respectively,under variable flow operation.The security of variable flow operation is superior to that of constant flow.It is also concluded that the climate region and function of the buildings are primary factors which affect the suitability of variable flow operation in GWSHP. 展开更多
关键词 地下水源热泵 变流量运行 含水层参数 特征 空调负荷 承压水头 恒定流量 建筑物
下载PDF
Monitoring actual performance of ground source heat pump system using GPRS-based data transmission: A case analysis in Tangshan 被引量:2
8
作者 杜红普 孔祥飞 +1 位作者 李敏 齐承英 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第4期1554-1562,共9页
The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is... The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability. 展开更多
关键词 地源热泵系统 数据监测 案例分析 数据传输 GPRS 使用性能 唐山 节能运行
下载PDF
Operating performance of novel reverse-cycle defrosting method based on thermal energy storage for air source heat pump 被引量:7
9
作者 董建锴 姜益强 +1 位作者 姚杨 张雪丹 《Journal of Central South University》 SCIE EI CAS 2011年第6期2163-2169,共7页
To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) metho... To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting. 展开更多
关键词 逆循环除霜 除霜方法 空气源热泵 热能储存 经营业绩 对比实验 持续时间 能源消耗
下载PDF
Heat balance of solar-soil source heat pump compound system 被引量:2
10
作者 陈金华 包修碧 +1 位作者 彭运林 贾宇 《Journal of Central South University》 SCIE EI CAS 2012年第3期809-815,共7页
Based on the state-of-the-art studies of solar-soil source heat pump compound system,operation patterns of solar-soil compound system were analyzed,particularly the advantages of parallel operation pattern.It is found... Based on the state-of-the-art studies of solar-soil source heat pump compound system,operation patterns of solar-soil compound system were analyzed,particularly the advantages of parallel operation pattern.It is found that parallel operation pattern is better for solar-soil compound system.Furthermore,the heat balance issue of solar-soil compound system was emphatically analyzed from four aspects,which were annual analysis of heating and cooling load,the heat exchange of ground heat exchanger,capacity determination of solar-assisted heat source and heat balance calculation of solar-soil compound system.Moreover,annual rate of heat balance in a solar-soil source heat pump compound system was calculated with a case study.It is shown that the annual heat unbalance ratio is 19%,which is less than 20%.As a result,the practical solar-soil compound system can basically maintain the heat balance of soil. 展开更多
关键词 土壤源热泵 热平衡计算 复合系统 太阳能 辅助加热 埋管换热器 平衡问题 冷却负荷
下载PDF
Experimental Investigation on System with Combination of Ground-Source Heat Pump and Solar Collector 被引量:4
11
作者 胡涛 朱家玲 张伟 《Transactions of Tianjin University》 EI CAS 2013年第3期157-167,共11页
This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calcu... This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calculation and experiment.The results show that the average absolute error is less than 0.6 ℃ and the relative error is less than 5% under the pulse load when the analytical solution to the 2-D solid cylindrical source model is used for the SAGSHPS.The coefficient of performance (COP) of the SAGSHPS is 2.95-4.70.The average fluid temperature in the borehole heat exchanger can increase by 3 ℃ with the assistance of solar collector,which will improve the COP of the heat pump by approximately 10% from the experimental data.The energy contributions to the total heating load of soil,electricity and solar are 56.30%,36.87% and 6.83%,respectively. 展开更多
关键词 ground-source HEAT pump solar energy heating performance BOREHOLE HEAT EXCHANGER
下载PDF
The Application of the Ground Source and Air-to-Water Heat Pumps in Cold Climate Areas 被引量:3
12
作者 Kaspar Tennokese Teet-Andrus Koiv +1 位作者 Alo Mikola Villu Vares 《Smart Grid and Renewable Energy》 2013年第7期473-481,共9页
This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulati... This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulation and analysis were carried out for a typical detached house, with 200 m2 of living area, the heat demand of 9 kW and the average heat demand for DHW production of 1 kW. In heating period the average Coefficient of Performance (COP) of the A&WHP is considerably lower than COP of the GSHP. 展开更多
关键词 Ground source Heat pump Air-Water Heat pump Heat Requirement COP
下载PDF
Performance analysis on solar-water compound source heat pump for radiant floor heating system
13
作者 曲世林 马飞 仇安兵 《Journal of Central South University》 SCIE EI CAS 2009年第S1期249-254,共6页
A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water t... A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system. 展开更多
关键词 heat pump SOLAR COMPOUND source COEFFICIENT of performance
下载PDF
Operation Performance of Air Source Heat Pump System for Space Heating in Tianjin 被引量:2
14
作者 赵军 陈雁 +1 位作者 曲航 李新国 《Transactions of Tianjin University》 EI CAS 2007年第2期137-141,共5页
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ... An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃. 展开更多
关键词 天津 气源热泵系统 供暖 运行性能 除霜
下载PDF
Study on corrosion behavior of heat exchanger in water source heat pump
15
作者 刘作华 龙洋 +2 位作者 李百战 丁勇 周小霞 《化工进展》 EI CAS CSCD 北大核心 2010年第S1期695-698,共4页
Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.T... Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.The river water collected in six different places of the Yangtze River and Jialing River in Chongqing were analyzed.Various parameters(pH,coexisted ions,and hardness value)were investigated.It showed that the Yangtze River and Jialing River water was suitable for developing water source heat pump technology.Further more,aimed at the temperature and pH of the raw water's variation range in a year,the corrosion behavior of copper material was studied by controlling the water environmental condition.Corrosion rate of copper is accelerated at high temperature and lower pH value. 展开更多
关键词 WATER source HEAT pump WATER quality RIVER WATER corrosion
下载PDF
Parallel Operation Characteristics Analysis of Sewage Source Heat Pump Units in Winter 被引量:2
16
作者 庄兆意 张承虎 +1 位作者 王海燕 孙德兴 《Transactions of Tianjin University》 EI CAS 2010年第6期461-466,共6页
Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running... Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multiple units but different parallel operation models, and the operation characteristics of units were analyzed as well. Results show that the single screw water-source heat pump can maintain high COP only at 60%—100% load ratio, COP decreases sharply with the decrease of load ratio, and the units with parallel operation are controlled by the load ratio of a single unit according to the reduction of total load which can keep the average COP at high level within a wide load range. 展开更多
关键词 污水来源 热泵单位 性能(警察) 的系数 部分负担 平行操作
下载PDF
Using Grey Relational Analysis to Evaluate Different Influencing Factors on Aquifer Parameters Variations with Groundwater Source Heat Pump Operation
17
作者 王松庆 张旭 贺士晶 《Journal of Donghua University(English Edition)》 EI CAS 2014年第3期244-248,共5页
The influence of particle migration induced by groundwater source heat pump( GWSHP) operation on aquifer parameters was theoretically analyzed. Then the sensitivity analysis of different influencing factors,which infl... The influence of particle migration induced by groundwater source heat pump( GWSHP) operation on aquifer parameters was theoretically analyzed. Then the sensitivity analysis of different influencing factors,which influenced aquifer parameters with GWSHP operation,was evaluated by using grey relational analysis method through a case study. The present study indicated that the erosion parameter, hydraulic conductivity and initial concentration were critical influencing factors which affected the aquifer parameters and the suitability of GWSHP. It also indicated that the discharge of single well should be controlled and the diameter of single well should be selected appropriately in order to decrease particle migration. 展开更多
关键词 GREY RELATIONAL analysis AQUIFER parameters GROUNDWATER source heat pump(GWSHP)
下载PDF
Experiments Using Capillary Mat as Ground Heat Exchanger for Ground Source Heat Pump Heating Application
18
作者 Arif Widiatmojo Shrestha Gaurav +5 位作者 Takeshi Ishihara Akira Tomigashi Kasumi Yasukawa Youhei Uchida Shohei Kaneko Mayumi Yoshioka 《Energy and Power Engineering》 2019年第11期363-378,共16页
The cooling and heating of spaces are among the largest sources for household’s energy demand. Ground Source Heat Pump (GSHP) is a promising technology to reduce the energy for cooling and heating purposes. However, ... The cooling and heating of spaces are among the largest sources for household’s energy demand. Ground Source Heat Pump (GSHP) is a promising technology to reduce the energy for cooling and heating purposes. However, the major obstacle hindering the utilization of this technology is the high initial cost, especially for the installation of ground coupled heat exchanger. The horizontal closed-loop system offers lower installation cost, as it requires no vertical borehole construction. Instead, the heat exchangers can be installed in shallow trenches that may be excavated, by small excavator or even by human labor. This paper presents the comparison of two different heat exchangers, namely, the capillary mat and the widely used slinky pipe. Both heat exchangers are connected to a heat pump, where continuous heating tests were carried out for 165 hours (~7 days) for each configuration. The purpose of this research is to show the performance of capillary mat in comparison to slinky pipe. Despite during the entire test for capillary mat required 6% higher electricity consumption, compared to slinky heat exchanger, the results still suggest the potential use of capillary mat as alternative to slinky heat exchanger. Additionally, the results also highlight the high hydraulic resistance of installed capillary mat heat exchangers may become the major disadvantage of the capillary mat. 展开更多
关键词 HORIZONTAL HEAT EXCHANGER Ground source HEAT pump CAPILLARY MAT
下载PDF
Comprehensive Benefit Analysis of Direct Expansion Ground Source Heat Pump System
19
作者 Yuefen Gao Yingxin Peng Juanjuan Liu 《Energy and Power Engineering》 2013年第2期76-81,共6页
Direct Expansion Ground Source Heat Pump (DXGSHP) system directly extracts heat or cold energy from ground by consuming electricity to provide for space conditioning. Compared with the currently widely-used secondary ... Direct Expansion Ground Source Heat Pump (DXGSHP) system directly extracts heat or cold energy from ground by consuming electricity to provide for space conditioning. Compared with the currently widely-used secondary loop Ground Couple Heat Pump (GCHP) system, it has higher energy efficiency, lower operating costs, and less environmental impact. A case study is carried out in this paper. The subject is a residential building located in Beijing, China. It is assumed that the building adopts the DXGSHP system and the GCHP system respectively. Annual loads and energy consumption are simulated and computed. Then the initial cost, operating cost and CO2 emission are calculated. The economic benefit is analyzed with the Payback Time method and the Dynamic Annual Cost Value method. The environmental benefit is discussed mainly by comparing the CO2 emission savings. The results show that the DXGSHP system has higher initial costs, but lower operating costs, and less greenhouse gas emissions. The DXGSHP system has better comprehensive benefits than the GCHP system. 展开更多
关键词 Direct EXPANSION GROUND source Heat pump ECONOMIC BENEFIT ENVIRONMENTAL BENEFIT
下载PDF
Analysis of Thermodynamic Characteristic Changes in Direct Expansion Ground Source Heat Pump Using Hydrofluoroolefins (HFOs) Substituting for HFC-134a
20
作者 Yuefen Gao Honglei Zhao +1 位作者 Yingxin Peng Tony Roskilly 《Energy and Power Engineering》 2013年第2期11-17,共7页
HFO-1234yf and HFO-1234ze[E] have low global warming potential and zero ozone depletion potential. If they are used in the direct expansion ground source heat pump system substituting for HFC-134a, the system will be ... HFO-1234yf and HFO-1234ze[E] have low global warming potential and zero ozone depletion potential. If they are used in the direct expansion ground source heat pump system substituting for HFC-134a, the system will be beneficial to mitigating climate change. This study aims to find out the thermodynamic characteristics of the direct expansion ground source heat pump system using HFO-1234yf or HFO-1234ze[E] by theoretical calculation. The results indicate that HFO-1234yf system in an actual cycle has the highest COP. HFO-1234yf and HFO-1234ze[E] have such smaller capacity per unit of swept volume that they need larger compression capacity if providing the same heating or cooling loads. For a given unit when HFC-134a is replaced with HFO-1234yf or HFO-1234ze[E], the capacity will decrease. More refrigerant charge is required in the HFO-1234yf or HFO-1234ze[E] system. The results also present that more refrigerant charge is required in the cooling mode than in the heating mode. 展开更多
关键词 Direct EXPANSION Ground source Heat pump (DXGSHP) THERMODYNAMIC Performance HFO-1234YF HFO-1234ze[E] HFC-134A