期刊文献+
共找到229篇文章
< 1 2 12 >
每页显示 20 50 100
Progress of Proximity Sensors for Potential Applications in Electronic Skins
1
作者 Runnan Zou Yanhong Tong +3 位作者 Jiayi Liu Jing Sun Da Xian Qingxin Tang 《Transactions of Tianjin University》 EI CAS 2024年第1期40-62,共23页
Recently,electronic skins and fl exible wearable devices have been developed for widespread applications in medical monitoring,artifi cial intelligence,human–machine interaction,and artifi cial prosthetics.Flexible p... Recently,electronic skins and fl exible wearable devices have been developed for widespread applications in medical monitoring,artifi cial intelligence,human–machine interaction,and artifi cial prosthetics.Flexible proximity sensors can accurately perceive external objects without contact,introducing a new way to achieve an ultrasensitive perception of objects.This article reviews the progress of fl exible capacitive proximity sensors,fl exible triboelectric proximity sensors,and fl exible gate-enhanced proximity sensors,focusing on their applications in the electronic skin fi eld.Herein,their working mechanism,materials,preparation methods,and research progress are discussed in detail.Finally,we summarize the future challenges in developing fl exible proximity sensors. 展开更多
关键词 Capacitive proximity sensors Triboelectric proximity sensors Gate-enhanced proximity sensors Flexible wearable devices electronic skins
下载PDF
Thermally Conductive and UV-EMI Shielding Electronic Textiles for Unrestricted and Multifaceted Health Monitoring 被引量:1
2
作者 Yidong Peng Jiancheng Dong +8 位作者 Jiayan Long Yuxi Zhang Xinwei Tang Xi Lin Haoran Liu Tuoqi Liu Wei Fan Tianxi Liu Yunpeng Huang 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第10期149-162,共14页
Skin-attachable electronics have garnered considerable research attention in health monitoring and artificial intelligence domains,whereas susceptibility to elec-tromagnetic interference(EMI),heat accumulation issues,... Skin-attachable electronics have garnered considerable research attention in health monitoring and artificial intelligence domains,whereas susceptibility to elec-tromagnetic interference(EMI),heat accumulation issues,and ultraviolet(UV)-induced aging problems pose significant constraints on their potential applications.Here,an ultra-elas-tic,highly breathable,and thermal-comfortable epidermal sensor with exceptional UV-EMI shielding performance and remarkable thermal conductivity is developed for high-fidelity monitoring of multiple human electrophysiological signals.Via filling the elastomeric microfibers with thermally conductive boron nitride nanoparticles and bridging the insulating fiber interfaces by plating Ag nanoparticles(NPs),an interwoven thermal con-ducting fiber network(0.72 W m^(-1) K^(-1))is constructed benefiting from the seamless thermal interfaces,facilitating unimpeded heat dissipation for comfort skin wearing.More excitingly,the elastomeric fiber substrates simultaneously achieve outstanding UV protection(UPF=143.1)and EMI shielding(SET>65,X-band)capabilities owing to the high electrical conductivity and surface plasmon resonance of Ag NPs.Furthermore,an electronic textile prepared by printing liquid metal on the UV-EMI shielding and thermally conductive nonwoven textile is finally utilized as an advanced epidermal sensor,which succeeds in monitoring different electrophysiological signals under vigorous electromagnetic interference.This research paves the way for developing protective and environmentally adaptive epidermal electronics for next-generation health regulation. 展开更多
关键词 skin electronics Thermal regulating textiles Electromagnetic interference shielding Ultraviolet proof Health monitoring
下载PDF
Flexible Tactile Electronic Skin Sensor with 3D Force Detection Based on Porous CNTs/PDMS Nanocomposites 被引量:21
3
作者 Xuguang Sun Jianhai Sun +9 位作者 Tong Li Shuaikang Zheng Chunkai Wang Wenshuo Tan Jingong Zhang Chang Liu Tianjun Ma Zhimei Qi Chunxiu Liu Ning Xue 《Nano-Micro Letters》 SCIE EI CAS CSCD 2019年第4期35-48,共14页
Flexible tactile sensors have broad applications in human physiological monitoring,robotic operation and human-machine interaction.However,the research of wearable and flexible tactile sensors with high sensitivity,wi... Flexible tactile sensors have broad applications in human physiological monitoring,robotic operation and human-machine interaction.However,the research of wearable and flexible tactile sensors with high sensitivity,wide sensing range and ability to detect three-dimensional(3D)force is still very challenging.Herein,a flexible tactile electronic skin sensor based on carbon nanotubes(CNTs)/polydimethylsiloxane(PDMS)nanocomposites is presented for 3D contact force detection.The 3D forces were acquired from combination of four specially designed cells in a sensing element.Contributed from the double-sided rough porous structure and specific surface morphology of nanocomposites,the piezoresistive sensor possesses high sensitivity of 12.1 kPa?1 within the range of 600 Pa and 0.68 kPa?1 in the regime exceeding 1 kPa for normal pressure,as well as 59.9 N?1 in the scope of<0.05 N and>2.3 N?1 in the region of<0.6 N for tangential force with ultra-low response time of 3.1 ms.In addition,multi-functional detection in human body monitoring was employed with single sensing cell and the sensor array was integrated into a robotic arm for objects grasping control,indicating the capacities in intelligent robot applications. 展开更多
关键词 Flexible TACTILE sensors electronic skin Piezoresistive sensors CNTs/PDMS NANOCOMPOSITES 3D force detection
下载PDF
Graphene Nanostructure-Based Tactile Sensors for Electronic Skin Applications 被引量:9
4
作者 Pei Miao Jian Wang +3 位作者 Congcong Zhang Mingyuan Sun Shanshan Cheng Hong Liu 《Nano-Micro Letters》 SCIE EI CAS CSCD 2019年第4期239-275,共37页
Skin is the largest organ of the human body and can perceive and respond to complex environmental stimulations.Recently,the development of electronic skin(E-skin)for the mimicry of the human sensory system has drawn g... Skin is the largest organ of the human body and can perceive and respond to complex environmental stimulations.Recently,the development of electronic skin(E-skin)for the mimicry of the human sensory system has drawn great attention due to its potential applications in wearable human health monitoring and care systems,advanced robotics,artificial intelligence,and human-machine interfaces.Tactile sense is one of the most important senses of human skin that has attracted special attention.The ability to obtain unique functions using diverse assembly processible methods has rapidly advanced the use of graphene,the most celebrated two-dimensional material,in electronic tactile sensing devices.With a special emphasis on the works achieved since 2016,this review begins with the assembly and modification of graphene materials and then critically and comprehensively summarizes the most advanced material assembly methods,device construction technologies and signal characterization approaches in pressure and strain detection based on graphene and its derivative materials.This review emphasizes on:(1)the underlying working principles of these types of sensors and the unique roles and advantages of graphene materials;(2)state-of-the-art protocols recently developed for high-performance tactile sensing,including representative examples;and(3)perspectives and current challenges for graphene-based tactile sensors in E-skin applications.A summary of these cutting-edge developments intends to provide readers with a deep understanding of the future design of high-quality tactile sensing devices and paves a path for their future commercial applications in the field of E-skin. 展开更多
关键词 GRAPHENE DERIVATIVES TACTILE sensor electronic skin Assembly
下载PDF
New skin closure system facilitates wound healing after cardiovascular implantable electronic device surgery 被引量:4
5
作者 Elia De Maria 《World Journal of Clinical Cases》 SCIE 2015年第8期675-677,共3页
The manuscript describes the efficacy of a new skin closure system(Zip Line?) for wound closure after pacemaker/implantable cardioverter defibrillator surgery. The system is particularly useful when wound healingis di... The manuscript describes the efficacy of a new skin closure system(Zip Line?) for wound closure after pacemaker/implantable cardioverter defibrillator surgery. The system is particularly useful when wound healingis difficult with traditional methods and in patients at high risk for surgical site infections(SSIs). This skin closure option is easy and quick to apply and remove, and produces excellent cosmetic results. Although it is associated with a minimal expense upcharge, the benefits, including the potential for decrease in SSI, make it attractive and worth considering for skin closure in device patients, particularly those at increased risk of complications. 展开更多
关键词 CARDIOVASCULAR IMPLANTABLE electronic device infection Surgical WOUND skin CLOSURE SYSTEM
下载PDF
Bioinspired MXene-Based User-Interactive Electronic Skin for Digital and Visual Dual-Channel Sensing 被引量:7
6
作者 Wentao Cao Zheng Wang +5 位作者 Xiaohao Liu Zhi Zhou Yue Zhang Shisheng He Daxiang Cui Feng Chen 《Nano-Micro Letters》 SCIE EI CAS CSCD 2022年第7期228-245,共18页
User-interactive electronic skin(e-skin) that could convert mechanical stimuli into distinguishable outputs displays tremendous potential for wearable devices and health care applications. However, the existing device... User-interactive electronic skin(e-skin) that could convert mechanical stimuli into distinguishable outputs displays tremendous potential for wearable devices and health care applications. However, the existing devices have the disadvantages such as complex integration procedure and lack of the intuitive signal display function. Here, we present a bioinspired user-interactive e-skin, which is simple in structure and can synchronously achieve digital electrical response and optical visualization upon external mechanical stimulus. The e-skin comprises a conductive layer with a carbon nanotubes/cellulose nanofibers/MXene nanohybrid network featuring remarkable electromechanical behaviors, and a stretchable elastomer layer, which is composed of silicone rubber and thermochromic pigments. Furthermore, the conductive nanohybrid network with outstanding Joule heating performance can generate controllable thermal energy under voltage input and then achieve the dynamic coloration of silicone-based elastomer. Especially, such an innovative fusion strategy of digital data and visual images enables the e-skin to monitor human activities with evermore intuition and accuracy. The simple design philosophy and reliable operation of the demonstrated e-skin are expected to provide an ideal platform for next-generation flexible electronics. 展开更多
关键词 MXene electronic skin Electromechanical behavior Joule heating Visualization
下载PDF
Transparent Electronic Skin Device Based on Microstructured Silver Nanowire Electrode 被引量:1
7
作者 吕汉白 平鑫宇 +2 位作者 高睿泉 许亮亮 潘力佳 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2017年第5期603-608,I0002,共7页
Transparent, flexible electronic skin holds a wide range of applications in robotics, humanmachine interfaces, artificial intelligence, prosthetics, and health monitoring. Silver nanowire are mechanically flexible and... Transparent, flexible electronic skin holds a wide range of applications in robotics, humanmachine interfaces, artificial intelligence, prosthetics, and health monitoring. Silver nanowire are mechanically flexible and robust, which exhibit great potential in transparent and electricconducting thin film. Herein, we report on a silver-nanowire spray-coating and electrodemicrostructure replicating strategy to construct a transparent, flexible, and sensitive electronic skin device. The electronic skin device shows highly sensitive piezo-capacitance response to pressure. It is found that micropatterning the surface of dielectric layer polyurethane elastomer by replicating from microstructures of natural-existing surfaces such as lotus leaf, silk, and frosted glass can greatly enhance the piezo-capacitance performance of the device. The microstructured pressure sensors based on silver nanowire exhibit good transparency, excellent flexibility, wide pressure detection range (0-150 kPa), and high sensitivity (1.28 kPa-1). 展开更多
关键词 electronic skin Pressure sensor Transparent electrode AgNWs Microstructure replica Polyurethane
下载PDF
Piezoresistive design for electronic skin: from fundamental to emerging applications 被引量:8
8
作者 Fang Zhong Wei Hu +4 位作者 Peining Zhu Han Wang Chao Ma Nan Lin Zuyong Wang 《Opto-Electronic Advances》 SCIE EI 2022年第8期75-106,共32页
There is growing recognition that the developments in piezoresistive devices from personal healthcare to artificial intelli-gence,will emerge as de novo translational success in electronic skin.Here,we review the upda... There is growing recognition that the developments in piezoresistive devices from personal healthcare to artificial intelli-gence,will emerge as de novo translational success in electronic skin.Here,we review the updates with regard to piezoresistive sensors including basic fundamentals,design and fabrication,and device performance.We also discuss the prosperous advances in piezoresistive sensor application,which offer perspectives for future electronic skin. 展开更多
关键词 electronic skin piezoresistive sensor BIOCOMPATIBILITY
下载PDF
Bioinspired All‑Fibrous Directional Moisture‑Wicking Electronic Skins for Biomechanical Energy Harvesting and All‑Range Health Sensing 被引量:5
9
作者 Chuanwei Zhi Shuo Shi +5 位作者 Shuai Zhang Yifan Si Jieqiong Yang Shuo Meng Bin Fei Jinlian Hu 《Nano-Micro Letters》 SCIE EI CAS CSCD 2023年第4期277-293,共17页
Electronic skins can monitor minute physiological signal variations in the human skins and represent the body’s state,showing an emerging trend for alternative medical diagnostics and human-machine interfaces.In this... Electronic skins can monitor minute physiological signal variations in the human skins and represent the body’s state,showing an emerging trend for alternative medical diagnostics and human-machine interfaces.In this study,we designed a bioinspired directional moisture-wicking electronic skin(DMWES)based on the construction of heterogeneous fibrous membranes and the conductive MXene/CNTs electrospraying layer.Unidirectional moisture transfer was successfully realized by surface energy gradient and push-pull effect via the design of distinct hydrophobic-hydrophilic difference,which can spontaneously absorb sweat from the skin.The DMWES membrane showed excellent comprehensive pressure sensing performance,high sensitivity(maximum sensitivity of 548.09 kPa^(−1)),wide linear range,rapid response and recovery time.In addition,the single-electrode triboelectric nanogenerator based on the DMWES can deliver a high areal power density of 21.6μW m^(−2) and good cycling stability in high pressure energy harvesting.Moreover,the superior pressure sensing and triboelectric performance enabled the DMWES for all-range healthcare sensing,including accurate pulse monitoring,voice recognition,and gait recognition.This work will help to boost the development of the next-generation breathable electronic skins in the applications of AI,human-machine interaction,and soft robots. 展开更多
关键词 BIOINSPIRED Electrospinning electronic skin Directional moisture wicking MXene
下载PDF
Skin-inspired electronics:emerging semiconductor devices and systems 被引量:3
10
作者 Zhong Ma Desheng Kong +1 位作者 Lijia Pan Zhenan Bao 《Journal of Semiconductors》 EI CAS CSCD 2020年第4期7-20,共14页
Current electronics are driven by advanced microfabrication for fast and efficient information processing.In spite of high performance,these wafer-based devices are rigid,non-degradable,and unable to autonomous repair... Current electronics are driven by advanced microfabrication for fast and efficient information processing.In spite of high performance,these wafer-based devices are rigid,non-degradable,and unable to autonomous repair.Skin-inspired electronics have emerged as a new class of devices and systems for next-generation flexible and wearable electronics.The technology gains inspiration from the structures,properties,and sensing mechanisms of the skin,which may find a broad range of applications in cutting-edge fields such as healthcare monitoring,human-machine interface,and soft robotics/prostheses.Practical demands have fueled the development of electronic materials with skin-like properties in terms of stretchability,self-healing capability,and biodegradability.These materials provide the basis for functional sensors with innovative and biomimetic designs.Further system-level integrations and optimizations enable new forms of electronics for real-world applications.This review summarizes recent advancements in this active area and speculates on future directions. 展开更多
关键词 electronic skin flexible electronicS HUMAN-MACHINE interface health monitoring soft ROBOTS
下载PDF
Breathable Electronic Skins for Daily Physiological Signal Monitoring 被引量:4
11
作者 Yi Yang Tianrui Cui +5 位作者 Ding Li Shourui Ji Zhikang Chen Wancheng Shao Houfang Liu Tian-Ling Ren 《Nano-Micro Letters》 SCIE EI CAS CSCD 2022年第10期108-135,共28页
With the aging of society and the increase in people’s concern for personal health,long-term physiological signal monitoring in daily life is in demand.In recent years,electronic skin(e-skin)for daily health monitori... With the aging of society and the increase in people’s concern for personal health,long-term physiological signal monitoring in daily life is in demand.In recent years,electronic skin(e-skin)for daily health monitoring applications has achieved rapid development due to its advantages in high-quality physiological signals monitoring and suitability for system integrations.Among them,the breathable e-skin has developed rapidly in recent years because it adapts to the long-term and high-comfort wear requirements of monitoring physiological signals in daily life.In this review,the recent achievements of breathable e-skins for daily physiological monitoring are systematically introduced and discussed.By dividing them into breathable e-skin electrodes,breathable e-skin sensors,and breathable e-skin systems,we sort out their design ideas,manufacturing processes,performances,and applications and show their advantages in long-term physiological signal monitoring in daily life.In addition,the development directions and challenges of the breathable e-skin are discussed and prospected. 展开更多
关键词 electronic skin Breathable Physiological signal monitoring Wearable systems
下载PDF
Dual-Fields Rotational Total Skin Electron Therapy: Investigation and Implementation
12
作者 M. Ming Xu Iris Rusu Richard P. Garza 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2024年第1期1-15,共15页
Purpose: To present a protocol of a dual-field rotational (DFR) total skin electron therapy (TSET) and to provide an assessment of clinical implementation, dosimetry properties, and skin dose evaluation. Methods and M... Purpose: To present a protocol of a dual-field rotational (DFR) total skin electron therapy (TSET) and to provide an assessment of clinical implementation, dosimetry properties, and skin dose evaluation. Methods and Materials: The DFR-TSET combined the Stanford 6-field and McGill rotational methods. Dual 6 MeV electron beams in high dose total skin electron mode were used for DFR-TSET on a commercial linac. Beam profiles and dosimetric properties were measured using solid phantoms. The dose rate at expanded source-to-surface distance (SSD) was a combination of static rate and rotational rate. In vivo dosimetry of patient skin was performed on patients’ skin using film, metal oxide semiconductor field-effect transistors (MOSFET), and optically stimulated luminescent dosimeters (OSLD). Results: Dual field rotational total skin electron therapy exhibited good (≤±10%) uniformity in the beam profiles in the vertical direction at an extended SSD of 332 cm with a gantry angulation of ±20˚ deviated from the horizontal direction. In-vivo measurements confirmed acceptable uniformity of the patients’ total body surfaces and revealed anatomically self-blocked or shielded areas where underdosing occurred. Conclusions: The clinical implementation of DFR-TSET effectively utilizes the special mode on a linac. This technique provides short beam-on times, uniform dose distribution, large treatment field, and reduced dose of x-ray contamination to the patients. In-vivo measurements indicate satisfactory delivery and dose uniformity of the prescribed dose. Electron boost fields are recommended at normal SSDs to address underdosed areas. 展开更多
关键词 Total skin electron Therapy Stanford 6 Field McGill Rotation Therapy In-Vivo Dosimetry
下载PDF
Healthcare electronic skin devices
13
作者 Quan Yuan Zhong Ma +1 位作者 Sheng Li Lijia Pan 《Journal of Semiconductors》 EI CAS CSCD 2019年第3期7-8,共2页
Electronic skin(e-skin),a kind of flexible sensor arrays and system that mimic the properties and sensing functions of human skin,represents a new paradigm of sensing and control(Fig.1).The noun of'skin electronic... Electronic skin(e-skin),a kind of flexible sensor arrays and system that mimic the properties and sensing functions of human skin,represents a new paradigm of sensing and control(Fig.1).The noun of'skin electronics'made its debut in the Sensitive Skin Workshop organized jointly by the National Science Foundation and Defense Advanced Research Projects Agency of USA in October 1999 in Arlington. 展开更多
关键词 In FLEXIBLE Healthcare electronic skin DEVICES
下载PDF
Biocompatible Multifunctional E-Skins with Excellent Self-Healing Ability Enabled by Clean and Scalable Fabrication 被引量:3
14
作者 Xiuzhu Lin Fan Li +4 位作者 Yu Bing Teng Fei Sen Liu Hongran Zhao Tong Zhang 《Nano-Micro Letters》 SCIE EI CAS CSCD 2021年第12期221-234,共14页
Electronic skins(e-skins) with an excellent sensing performance have been widely developed over the last few decades.However,wearability,biocompatibility,environmental friendliness and scalability have become new limi... Electronic skins(e-skins) with an excellent sensing performance have been widely developed over the last few decades.However,wearability,biocompatibility,environmental friendliness and scalability have become new limitations. Self-healing ability can improve the long-term robustness and reliability of e-skins. However,self-healing ability and integration are hardly balanced in classical structures of self-healable devices. Here,cellulose nanofiber/poly(vinyl alcohol)(CNF/PVA),a biocompatible moisture-inspired self-healable composite,was applied both as the binder in functional layers and the substrate. Various functional layers comprising particular carbon materials and CNF/PVA were patterned on the substrate. A planar structure was beneficial for integration,and the active self-healing ability of the functional layers endowed self-healed e-skins with a higher toughness. Water served as both the only solvent throughout the fabrication process and the trigger of the self-healing process,which avoids the pollution and bioincompatibility caused by the application of noxious additives. Our e-skins could achieve real-time monitoring of whole-body physiological signals and environmental temperature and humidity. Cross-interference between di erent external stimuli was suppressed through reasonable material selection and structural design. Combined with conventional electronics,data could be transmitted to a nearby smartphone for post-processing. This work provides a previously unexplored strategy for multifunctional e-skins with an excellent practicality. 展开更多
关键词 Self-healing electronics Strain sensors Environmental friendly method Multifunctional e-skins SCALABILITY
下载PDF
Transparent,Ultra-Stretching,Tough,Adhesive Carboxyethyl Chitin/Polyacrylamide Hydrogel Toward High-Performance Soft Electronics 被引量:4
15
作者 Jipeng Zhang Yang Hu +2 位作者 Lina Zhang Jinping Zhou Ang Lu 《Nano-Micro Letters》 SCIE EI CAS CSCD 2023年第1期161-182,共22页
To date,hydrogels have gained increasing attentions as a flexible conductive material in fabricating soft electronics.However,it remains a big challenge to integrate multiple functions into one gel that can be used wi... To date,hydrogels have gained increasing attentions as a flexible conductive material in fabricating soft electronics.However,it remains a big challenge to integrate multiple functions into one gel that can be used widely under various conditions.Herein,a kind of multifunc-tional hydrogel with a combination of desirable characteristics,including remarkable transparency,high conductivity,ultra-stretchability,tough-ness,good fatigue resistance,and strong adhesive ability is presented,which was facilely fabricated through multiple noncovalent crosslinking strategy.The resultant versatile sensors are able to detect both weak and large deformations,which owns a low detection limit of 0.1%strain,high stretchability up to 1586%,ultrahigh sensitivity with a gauge factor up to 18.54,as well as wide pressure sensing range(0-600 kPa).Meanwhile,the fabrication of conductive hydrogel-based sensors is demonstrated for various soft electronic devices,including a flexible human-machine interactive system,the soft tactile switch,an integrated electronic skin for unprecedented nonplanar visualized pressure sensing,and the stretchable triboelectric nanogenerators with excellent biomechanical energy harvesting ability.This work opens up a simple route for multifunctional hydrogel and promises the practical application of soft and self-powered wearable electronics in various complex scenes. 展开更多
关键词 Conductive hydrogels Multifunctional sensors Human-machine interaction electronic skin Stretchable triboelectric nanogenerators
下载PDF
Measurement of Electron Return Effect and Skin Dose Reduction by a Bolus in an Anthropomorphic Physical Phantom under a Magnetic Resonance Guided Linear Accelerator (MR-LINAC) System 被引量:1
16
作者 Eun Young Han Zhifei Wen +2 位作者 Hannah J. Lee Arnold dela Cruz Paulino Choonsik Lee 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第3期339-346,共8页
Background: Magnetic resonance image-guided radiation therapy (MR-IGRT) promises more precise and effective radiation treatments compared to conventional IGRT by using real-time on-board MR imaging. Under the influenc... Background: Magnetic resonance image-guided radiation therapy (MR-IGRT) promises more precise and effective radiation treatments compared to conventional IGRT by using real-time on-board MR imaging. Under the influence of a magnetic field, however, secondary electrons exiting a surface can be forced in a circular path and re-enter the medium, resulting in dose increase at a beam-exit surface, called the electron return effect (ERE). The purpose of the study is to compare the exit skin dose computed by Monte Carlo dose calculation with measurements using an adult anthropomorphic phantom and to measure the effect of skin dose reduction by adding 1 cm-thick bolus. Method: The plan was compared with measurements using an adult anthropomorphic phantom combined with radiochromic films and thermoluminescent dosimeters. We also measured the skin dose reduction by adding 1 cm-thick bolus on the frontal surface of the phantom. Results: We found that 1 cm-thick bolus reduced the skin dose by up to 20% both in measurements and calculations. The plan was found to overestimate the measured skin dose by about 10% and there was no significant difference in the bolus effect between the breast skin and the skin (without breast attachment) doses. Conclusion: In conclusion, we confirmed the ERE effect on the anthropomorphic phantom under the magnetic field and the exit skin dose reduction by adding a bolus. Skin dose measurements using anthropomorphic phantom may be helpful to evaluate more realistic skin dose and the bolus effect in the magnetic field. 展开更多
关键词 MR-Linac electron RETURN EFFECT skin Dose
下载PDF
Low Dose Total Skin Electron Beam Radiation in Cutaneous T-Cell Lymphoma: Review 被引量:1
17
作者 Misty Gamble Elizabeth Tocci Jennifer A. DeSimone 《Journal of Cancer Therapy》 2014年第14期1372-1379,共8页
The treatment of advanced stage MF is especially challenging as single agent overall response rates are in the 35% range and chronic recurrence is the rule. The treatment of CTCL across all stages of disease is aimed ... The treatment of advanced stage MF is especially challenging as single agent overall response rates are in the 35% range and chronic recurrence is the rule. The treatment of CTCL across all stages of disease is aimed at the goal of achieving and sustaining remission. Increasingly, low dose total skin electron beam therapy (TSEBT) is being utilized as a skin directed component in combination therapy for advanced stage CTCL. Researchers are seeking to better define the utility of low dose TSEBT as a method of debulking skin disease while simultaneously treating other disease compartments and in combination with sustained maintenance therapies of both the skin directed and systemic varieties. Data exists showing the efficacy of low dose TSEBT in early and advanced disease. There is also data documenting prolonged treatment responses with TSEBT plus adjuvant skin directed therapies such as PUVA and topical nitrogen mustard. Emerging data examining the role of low dose TSEBT in the prestem cell transplant preparation is also promising. This brief review summarizes the utility of low dose TSEBT in multiagent treatment regimens in CTCL. 展开更多
关键词 Cutaneous T-CELL Lymphoma MYCOSIS Fungoides TOTAL skin electron Beam Therapy HEMATOPOIETIC Stem Cell Transplantation
下载PDF
Ultraconformable Integrated Wireless Charging Micro-Supercapacitor Skin 被引量:2
18
作者 Chang Gao Qing You +5 位作者 Jiancheng Huang Jingye Sun Xuan Yao Mingqiang Zhu Yang Zhao Tao Deng 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第7期46-58,共13页
Conformable and wire-less charging energy storage devices play important roles in enabling the fast development of wearable,non-contact soft electronics.However,current wire-less charging power sources are still restr... Conformable and wire-less charging energy storage devices play important roles in enabling the fast development of wearable,non-contact soft electronics.However,current wire-less charging power sources are still restricted by limited flexural angles and fragile connection of components,resulting in the failure expression of performance and constraining their fur-ther applications in health monitoring wearables and moveable artificial limbs.Herein,we present an ultracompatible skin-like integrated wireless charging micro-supercapacitor,which building blocks(including electrolyte,electrode and substrate)are all evaporated by liquid precursor.Owing to the infiltration and permeation of the liquid,each part of the integrated device attached firmly with each other,forming a compact and all-in-one configuration.In addition,benefitting from the controllable volume of electrode solution precursor,the electrode thickness is easily regulated varying from 11.7 to 112.5μm.This prepared thin IWC-MSC skin can fit well with curving human body,and could be wireless charged to store electricity into high capacitive micro-supercapacitors(11.39 F cm-3)of the integrated device.We believe this work will shed light on the construction of skin-attachable electronics and irregular sensing microrobots. 展开更多
关键词 Micro-supercapacitor electronic skin Supercapacitor skin Wireless charging energy storage device
下载PDF
Commissioning and Optimization of a Total Skin Electron Therapy Technique Using a High Dose Rate Electron Facility
19
作者 Y. A. M. Yousif Casper A. Willemse 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第3期197-207,共11页
Total skin electron therapy (TSET) is used for the treatment of Mycosis Fungoides. Several tech-niques have been developed, in order to achieve homogeneous dose distribution over the complete body surface. To implemen... Total skin electron therapy (TSET) is used for the treatment of Mycosis Fungoides. Several tech-niques have been developed, in order to achieve homogeneous dose distribution over the complete body surface. To implement a TSET technique, one has to optimize a variety of parameters. Monte Carlo simulation of TSET can facilitate this optimization. The aim of this study was to commission and optimize a TSET technique using the 4 and 6 MeV electron and the high dose rate facility on the Elekta Precise accelerator. The EGS4nrc/BEAMnrc Monte Carlo code was used. The beam data were calculated and measured at two different scoring planes for a single beam. The Model was validated by comparing the simulation with measurements. Two different vertical angles were used to obtain a uniform dose. The angle was optimized for best dose uniformity. The Rando phantom is placed on a rotating platform and rotates 60 degrees apart to facilitate the six patient position orientations. The doses delivered in a phantom by complete treatment were measured with Kodak EDR2 films and TLDs. The dose distribution varied among various scanning directions by 2 - 3 mm and 3 - 4 mm for 4 and 6 MeV respectively. The composite percentage depth dose of all six dual fields for the 4 and 6 MeV yielded an R80 of ~4 mm and ~6 mm, respectively. Dose uniformity was ±6% for 4 MeV and ±5% for 6 MeV. The bremsstrahlung contamination was 0.9% - 1.3%. Good agreements were found with published literature and inline with international protocols. 展开更多
关键词 TOTAL skin electron THERAPY MYCOSIS Fungoides High DOSE Rate electron Monte Carlo Simulation
下载PDF
Radiation dose enhancement in skin therapy with nanoparticle addition: A Monte Carlo study on kilovoltage photon and megavoltage electron beams
20
作者 Xiao J Zheng James C L Chow 《World Journal of Radiology》 CAS 2017年第2期63-71,共9页
AIMTo investigated the dose enhancement due to the incorporation of nanoparticles in skin therapy using the kilovoltage (kV) photon and megavoltage (MV) electron beams. Monte Carlo simulations were used to predict the... AIMTo investigated the dose enhancement due to the incorporation of nanoparticles in skin therapy using the kilovoltage (kV) photon and megavoltage (MV) electron beams. Monte Carlo simulations were used to predict the dose enhancement when different types and concentrations of nanoparticles were added to skin target layers of varying thickness.METHODSClinical kV photon beams (105 and 220 kVp) and MV electron beams (4 and 6 MeV), produced by a Gulmay D3225 orthovoltage unit and a Varian 21 EX linear accelerator, were simulated using the EGSnrc Monte Carlo code. Doses at skin target layers with thicknesses ranging from 0.5 to 5 mm for the photon beams and 0.5 to 10 mm for the electron beams were determined. The skin target layer was added with the Au, Pt, I, Ag and Fe<sub>2</sub>O<sub>3</sub> nanoparticles with concentrations ranging from 3 to 40 mg/mL. The dose enhancement ratio (DER), defined as the dose at the target layer with nanoparticle addition divided by the dose at the layer without nanoparticle addition, was calculated for each nanoparticle type, nanoparticle concentration and target layer thickness.RESULTSIt was found that among all nanoparticles, Au had the highest DER (5.2-6.3) when irradiated with kV photon beams. Dependence of the DER on the target layer thickness was not significant for the 220 kVp photon beam but it was for 105 kVp beam for Au nanoparticle concentrations higher than 18 mg/mL. For other nanoparticles, the DER was dependent on the atomic number of the nanoparticle and energy spectrum of the photon beams. All nanoparticles showed an increase of DER with nanoparticle concentration during the photon beam irradiations regardless of thickness. For electron beams, the Au nanoparticles were found to have the highest DER (1.01-1.08) when the beam energy was equal to 4 MeV, but this was drastically lower than the DER values found using photon beams. The DER was also found affected by the depth of maximum dose of the electron beam and target thickness. For other nanoparticles with lower atomic number, DERs in the range of 0.99-1.02 were found using the 4 and 6 MeV electron beams.CONCLUSIONIn nanoparticle-enhanced skin therapy, Au nanoparticle addition can achieve the highest dose enhancement with 105 kVp photon beams. Electron beams, while popular for skin therapy, did not produce as high dose enhancements as kV photon beams. Additionally, the DER is dependent on nanoparticle type, nanoparticle concentration, skin target thickness and energies of the photon and electron beams. 展开更多
关键词 skin therapy Monte Carlo simulation NANOPARTICLE Dose enhancement Photon and electron beams
下载PDF
上一页 1 2 12 下一页 到第
使用帮助 返回顶部