This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The desi...This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request.展开更多
A high performance current and voltage measurement system has been developed in power system. The system is composed of two parts: one current measurement element and one voltage measurement element. A Rogowski coil ...A high performance current and voltage measurement system has been developed in power system. The system is composed of two parts: one current measurement element and one voltage measurement element. A Rogowski coil and a capacitive voltage divider are used respectively for the line current and voltage measurements. Active electronic components are used to modulate signal, and power supply for these components is drawn from power line via an auxiliary current transformer. Measurement signal is transmitted by optical fibers, which is resistant to electromagnetic induction and noise. With careful design and the use of digital signal processing technology, the whole system can meet 0.5% accuracy for metering and provides large dynamic range coupled with good accuracy for protective relaying use.展开更多
Power electronic zigzag transformer is an attractive solution for the flexible interconnection of smart distribution networks.It is constituted by slow-response and low-precision thyristor converters and fast-response...Power electronic zigzag transformer is an attractive solution for the flexible interconnection of smart distribution networks.It is constituted by slow-response and low-precision thyristor converters and fast-response and high-accuracy voltage source converters.This paper models its primary circuit and addresses its basic operation mechanism.Then a dual-timescale control scheme is investigated to realize the coordinated regulation of both types of converter.A simulation case is established in PSCAD containing interconnected mid-voltage distribution networks.Simulations with poor-and well-matched control timescales are both carried out.And accordingly,the power flow controllability under these conditions is compared.When the shorter control timescale is no more than tenth of the longer one,the power electronic zigzag transformer will operate with satisfying performances.展开更多
为有效降低电容型电子式电压互感器EVT(electronic voltage transformer)的主电容量,以研制的110k V电容型EVT分压器为例,建立了其有限元模型并仿真研究了施加屏蔽对分压器性能的影响,优化结构参数并获得了主电容量的最优值。仿真和计...为有效降低电容型电子式电压互感器EVT(electronic voltage transformer)的主电容量,以研制的110k V电容型EVT分压器为例,建立了其有限元模型并仿真研究了施加屏蔽对分压器性能的影响,优化结构参数并获得了主电容量的最优值。仿真和计算结果表明:施加屏蔽可以有效减小杂散电容对测量准确度的影响;外屏蔽的半径和安装高度是设计时需要考虑的重要参数;通过优化结构参数,可使主电容量为500 p F的EVT分压器的测量准确度小于0.1%。展开更多
This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly f...This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly from high-voltage (HV) transmission lines to low-voltage (LV) consumers through coupling capacitors and is said to be cost-effective as compared to conventional distribution networks. However, the functionality of such substations is susceptible to various transient phenomena, including ferroresonance and overvoltage occurrences. To address these challenges, the study uses simulations to evaluate the effectiveness of conventional resistor-inductor-capacitor (RLC) filter in mitigating hazardous overvoltage resulting from transients. The proposed methodology entails using standard RLC filter to suppress transients and its associated overvoltage risks. Through a series of MATLAB/Simulink simulations, the research emphasizes the practical effectiveness of this technique. The study examines the impact of transients under varied operational scenarios, including no-load switching conditions, temporary short-circuits, and load on/off events. The primary aim of the article is to assess the viability of using an established technology to manage system instabilities upon the energization of a CCS under no-load circumstances or in case of a short-circuit fault occurring on the primary side of the CCS distribution transformer. The findings underscore the effectiveness of conventional RLC filters in suppressing transients induced by the CCS no-load switching.展开更多
针对电力电子变压器的非线性特性,传统PI控制的单相电力电子变压器整流级具有对参数变化敏感,响应速度慢,抗扰性能差的特点。提出了一种基于线性自抗扰控制(line active disturbance rejection control,LADRC)的电压环控制策略,该控制...针对电力电子变压器的非线性特性,传统PI控制的单相电力电子变压器整流级具有对参数变化敏感,响应速度慢,抗扰性能差的特点。提出了一种基于线性自抗扰控制(line active disturbance rejection control,LADRC)的电压环控制策略,该控制策略具有响应速度快、超调量小、鲁棒性强的特点。在仿真软件MATLAB/Simulink中通过搭建三级联H桥整流器模型进行仿真,并与传统PI控制器相比较,仿真结果表明所采用控制策略的优越性、有效性。展开更多
基金Project supported by the National Natural Science Foundation of China (Grant No.50447006)
文摘This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request.
文摘A high performance current and voltage measurement system has been developed in power system. The system is composed of two parts: one current measurement element and one voltage measurement element. A Rogowski coil and a capacitive voltage divider are used respectively for the line current and voltage measurements. Active electronic components are used to modulate signal, and power supply for these components is drawn from power line via an auxiliary current transformer. Measurement signal is transmitted by optical fibers, which is resistant to electromagnetic induction and noise. With careful design and the use of digital signal processing technology, the whole system can meet 0.5% accuracy for metering and provides large dynamic range coupled with good accuracy for protective relaying use.
基金This work was supported by the National Natural Science Foundation of China(51490680,51490683).
文摘Power electronic zigzag transformer is an attractive solution for the flexible interconnection of smart distribution networks.It is constituted by slow-response and low-precision thyristor converters and fast-response and high-accuracy voltage source converters.This paper models its primary circuit and addresses its basic operation mechanism.Then a dual-timescale control scheme is investigated to realize the coordinated regulation of both types of converter.A simulation case is established in PSCAD containing interconnected mid-voltage distribution networks.Simulations with poor-and well-matched control timescales are both carried out.And accordingly,the power flow controllability under these conditions is compared.When the shorter control timescale is no more than tenth of the longer one,the power electronic zigzag transformer will operate with satisfying performances.
文摘为有效降低电容型电子式电压互感器EVT(electronic voltage transformer)的主电容量,以研制的110k V电容型EVT分压器为例,建立了其有限元模型并仿真研究了施加屏蔽对分压器性能的影响,优化结构参数并获得了主电容量的最优值。仿真和计算结果表明:施加屏蔽可以有效减小杂散电容对测量准确度的影响;外屏蔽的半径和安装高度是设计时需要考虑的重要参数;通过优化结构参数,可使主电容量为500 p F的EVT分压器的测量准确度小于0.1%。
文摘This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly from high-voltage (HV) transmission lines to low-voltage (LV) consumers through coupling capacitors and is said to be cost-effective as compared to conventional distribution networks. However, the functionality of such substations is susceptible to various transient phenomena, including ferroresonance and overvoltage occurrences. To address these challenges, the study uses simulations to evaluate the effectiveness of conventional resistor-inductor-capacitor (RLC) filter in mitigating hazardous overvoltage resulting from transients. The proposed methodology entails using standard RLC filter to suppress transients and its associated overvoltage risks. Through a series of MATLAB/Simulink simulations, the research emphasizes the practical effectiveness of this technique. The study examines the impact of transients under varied operational scenarios, including no-load switching conditions, temporary short-circuits, and load on/off events. The primary aim of the article is to assess the viability of using an established technology to manage system instabilities upon the energization of a CCS under no-load circumstances or in case of a short-circuit fault occurring on the primary side of the CCS distribution transformer. The findings underscore the effectiveness of conventional RLC filters in suppressing transients induced by the CCS no-load switching.
文摘针对电力电子变压器的非线性特性,传统PI控制的单相电力电子变压器整流级具有对参数变化敏感,响应速度慢,抗扰性能差的特点。提出了一种基于线性自抗扰控制(line active disturbance rejection control,LADRC)的电压环控制策略,该控制策略具有响应速度快、超调量小、鲁棒性强的特点。在仿真软件MATLAB/Simulink中通过搭建三级联H桥整流器模型进行仿真,并与传统PI控制器相比较,仿真结果表明所采用控制策略的优越性、有效性。