In this study we systematically analyzed the elution condition of tryptic peptides and the characteristics of identi?ed peptides in reverse phase liquid chromatogra- phy and electrospray tandem mass spectrometry (RPLC...In this study we systematically analyzed the elution condition of tryptic peptides and the characteristics of identi?ed peptides in reverse phase liquid chromatogra- phy and electrospray tandem mass spectrometry (RPLC-MS/MS) analysis. Fol- lowing protein digestion with trypsin, the peptide mixture was analyzed by on-line RPLC-MS/MS. Bovine serum albumin (BSA) was used to optimize acetonitrile (ACN) elution gradient for tryptic peptides, and Cytochrome C was used to retest the gradient and the sensitivity of LC-MS/MS. The characteristics of identi?ed peptides were also analyzed. In our experiments, the suitable ACN gradient is 5% to 30% for tryptic peptide elution and the sensitivity of LC-MS/MS is 50 fmol. Analysis of the tryptic peptides demonstrated that longer (more than 10 amino acids) and multi-charge state (+2, +3) peptides are likely to be identi?ed, and the hydropathicity of the peptides might not be related to whether it is more likely to be identi?ed or not. The number of identi?ed peptides for a protein might be used to estimate its loading amount under the same sample background. Moreover, in this study the identi?ed peptides present three types of redundancy, namely iden- ti?cation, charge, and sequence redundancy, which may repress low abundance protein identi?cation.展开更多
The positive and negative ESI-MS/MS spectra of N-ethoxy(phenyl) phosphoryl amino acids(EPP-AA) were investigated by electrospray ionization(ESI) ion trap mass spectrometry. The fragmentation pathways of [ M + N...The positive and negative ESI-MS/MS spectra of N-ethoxy(phenyl) phosphoryl amino acids(EPP-AA) were investigated by electrospray ionization(ESI) ion trap mass spectrometry. The fragmentation pathways of [ M + Na]^+ and [ M - H]^- ions are proposed and rationalized. The observation may have some potential applications in the interpretation of the MS/MS spectra of novel N-phosphoryl compounds. The complexity of MS/MS spectra of EPP-AA [ M + Na]^+ ions is decreased compared with that of N-dialkyloxyphosphoryl amino acid. Therefore, the new phosphonamidate method may be considered one of the superior methods that can be used in sequencing peptides and proteins extensively.展开更多
Puerarin,an isoflavone compound,is the bioactive component of traditional Chinese medicine.A novel dialkyl puerarin-7-yl phosphate was synthesized and investigated by positive ion electrospray ionization ion trap mass...Puerarin,an isoflavone compound,is the bioactive component of traditional Chinese medicine.A novel dialkyl puerarin-7-yl phosphate was synthesized and investigated by positive ion electrospray ionization ion trap mass spectrometry (ESI MS)in conjunction with tandem mass spectrometry.The fragmentation pathways of dialkyl puerarin-7-yl phosphates were investigated.展开更多
基金This work was partially supported by grants fromthe National Basic Research Program (973) of China(2004CB520804), and National Natural Science Foun-dation of China (No. 30270657, 30230150, 3037030).
文摘In this study we systematically analyzed the elution condition of tryptic peptides and the characteristics of identi?ed peptides in reverse phase liquid chromatogra- phy and electrospray tandem mass spectrometry (RPLC-MS/MS) analysis. Fol- lowing protein digestion with trypsin, the peptide mixture was analyzed by on-line RPLC-MS/MS. Bovine serum albumin (BSA) was used to optimize acetonitrile (ACN) elution gradient for tryptic peptides, and Cytochrome C was used to retest the gradient and the sensitivity of LC-MS/MS. The characteristics of identi?ed peptides were also analyzed. In our experiments, the suitable ACN gradient is 5% to 30% for tryptic peptide elution and the sensitivity of LC-MS/MS is 50 fmol. Analysis of the tryptic peptides demonstrated that longer (more than 10 amino acids) and multi-charge state (+2, +3) peptides are likely to be identi?ed, and the hydropathicity of the peptides might not be related to whether it is more likely to be identi?ed or not. The number of identi?ed peptides for a protein might be used to estimate its loading amount under the same sample background. Moreover, in this study the identi?ed peptides present three types of redundancy, namely iden- ti?cation, charge, and sequence redundancy, which may repress low abundance protein identi?cation.
基金Supported by the Education Department of Henan Province(No. 200510459015).
文摘The positive and negative ESI-MS/MS spectra of N-ethoxy(phenyl) phosphoryl amino acids(EPP-AA) were investigated by electrospray ionization(ESI) ion trap mass spectrometry. The fragmentation pathways of [ M + Na]^+ and [ M - H]^- ions are proposed and rationalized. The observation may have some potential applications in the interpretation of the MS/MS spectra of novel N-phosphoryl compounds. The complexity of MS/MS spectra of EPP-AA [ M + Na]^+ ions is decreased compared with that of N-dialkyloxyphosphoryl amino acid. Therefore, the new phosphonamidate method may be considered one of the superior methods that can be used in sequencing peptides and proteins extensively.
文摘Puerarin,an isoflavone compound,is the bioactive component of traditional Chinese medicine.A novel dialkyl puerarin-7-yl phosphate was synthesized and investigated by positive ion electrospray ionization ion trap mass spectrometry (ESI MS)in conjunction with tandem mass spectrometry.The fragmentation pathways of dialkyl puerarin-7-yl phosphates were investigated.