As the basic of a deeper investigation on the turbulent transport, the fluctuation property in the boundary of the newly-reconstructed Joint Texas Experimental Tokamak (J- TEXT) is studied experimentally using the r...As the basic of a deeper investigation on the turbulent transport, the fluctuation property in the boundary of the newly-reconstructed Joint Texas Experimental Tokamak (J- TEXT) is studied experimentally using the reciprocating Langmuir four-tip probe, which has been built and operated as the primary diagnostic tool in the boundary of J-TEXT tokamak. In this paper, spatial profiles of the plasma-edge parameters are obtained, such as electron temperature, plasma density, plasma potential, poloidal electric field and their fluctuations. The results indicate the existence of a Er ×BT shear layer at the vicinity of last closed flux surface (LCFS), with the fluctuations suppressed in varying degrees. The turbulence-induced particle and energy fluxes can be calculated by the local plasma parameters above. Convection dominates the cross-field turbulent transport in boundary plasma. Electrostatic fluctuations properties are also studied in detail with the help of numerical analysis. Statistical analysis on density fluctuation shows that, the intermittency can affect the turbulence in the scrape-off layer (SOL).展开更多
A novel electromagnetic probe array(EMPA) diagnostic, which consists of a magnetic probe array and an electrostatic probe array, has recently been developed on EAST. The EMPA is fixed near the first wall at horizontal...A novel electromagnetic probe array(EMPA) diagnostic, which consists of a magnetic probe array and an electrostatic probe array, has recently been developed on EAST. The EMPA is fixed near the first wall at horizontal port P. The magnetic probe array of the EMPA consists of 24 identical magnetic probes, each of them capable of measuring toroidal, poloidal and radial magnetic fluctuations simultaneously, providing additional toroidal magnetic fluctuation measurements compared with the regular magnetic probes on EAST. With a higher sampling rate and self-resonant frequency, the EMPA magnetic probes can provide higher frequency magnetic fluctuation measurements. The magnetic probe array of the EMPA is composed of two parallel layers of magnetic probes with a radial distance of 63 mm, and each layer of magnetic probes is arranged in four poloidal rows and three toroidal columns. The compact arrangement of the EMPA magnetic probe array largely improves the toroidal mode number measurement ability from-8≤ n≤ 8 to-112≤ n≤ 112, and also improves the high poloidal wave number measurement ability of magnetic fluctuations compared with the regular high frequency magnetic probes on EAST. The electrostatic probe array of the EMPA consists of two sets of four-tip probes and a single-tip probe array with three poloidal rows and four toroidal columns. It complements the electrostatic parameter measurements behind the main limiter and near the first wall in EAST. The engineering details of the EMPA diagnostic, including the mechanical system, the electrical system, the acquisition and control system, and the effective area calibration, are presented. The preliminary applications of the EMPA in L-mode and H-mode discharges on EAST have demonstrated that the EMPA works well for providing information on the magnetic and electrostatic fluctuations and can contribute to deeper physical analysis in future EAST experiments.展开更多
The effect of background fluctuation on velocity diagnostics is discussed and studied. The kinetic theory of Mach probe(MP) and the theory of BGK mode are combined to evaluate how the measurement of MP is affected by ...The effect of background fluctuation on velocity diagnostics is discussed and studied. The kinetic theory of Mach probe(MP) and the theory of BGK mode are combined to evaluate how the measurement of MP is affected by electrostatics fluctuation. It is found that the quantity of speed by the MP model is closer to the effective velocity in the picture of momentum flux rather than the real mean velocity, while, with high fluctuation, the fitting parameter of MP's exponential formula should be corrected.展开更多
Vigorous particle collisions and mechanical processes occurring during high-velocity pneumatic con- veying often lead to particle degradation. The resulting particle size reduction and particle number increase will im...Vigorous particle collisions and mechanical processes occurring during high-velocity pneumatic con- veying often lead to particle degradation. The resulting particle size reduction and particle number increase will impact on the flow characteristics, and subsequently affect the electrostatic type of flow measurements. This study investigates this phenomenon using both experimental and numerical meth- ods. Particle degradation was induced experimentally by recursively conveying the fillite material within a pneumatic pipeline. The associated particle size reduction was monitored. Three electrostatic sensors were embedded along the pipeline to monitor the flow. The results indicated a decreasing trend in the electrostatic sensor outputs with decreasing particle size, which suggested the attenuation of the flow velocity fluctuation. This trend was more apparent at higher conveying velocities, which suggested that more severe particle degradation occurred under these conditions. Coupled computational fluid dynamics and discrete element methods (CFD-DEM) analysis was used to qualitatively validate these experimental results. The numerical results suggested that smaller particles exhibited lower flow velocity fluctua- tions, which was consistent with the observed experimental results. These findings provide important information for the accurate aoolication of electrostatic measurement devices in oneumatic conveyors.展开更多
基金supported by Open Research Program from Key Laboratory of Geospace Environment, Chinese Academy of Sciences
文摘As the basic of a deeper investigation on the turbulent transport, the fluctuation property in the boundary of the newly-reconstructed Joint Texas Experimental Tokamak (J- TEXT) is studied experimentally using the reciprocating Langmuir four-tip probe, which has been built and operated as the primary diagnostic tool in the boundary of J-TEXT tokamak. In this paper, spatial profiles of the plasma-edge parameters are obtained, such as electron temperature, plasma density, plasma potential, poloidal electric field and their fluctuations. The results indicate the existence of a Er ×BT shear layer at the vicinity of last closed flux surface (LCFS), with the fluctuations suppressed in varying degrees. The turbulence-induced particle and energy fluxes can be calculated by the local plasma parameters above. Convection dominates the cross-field turbulent transport in boundary plasma. Electrostatic fluctuations properties are also studied in detail with the help of numerical analysis. Statistical analysis on density fluctuation shows that, the intermittency can affect the turbulence in the scrape-off layer (SOL).
基金supported by the National Magnetic Confinement Fusion Energy R&D Program of China (Nos. 2019YFE03030000 and 2022YFE03020004)National Natural Science Foundation of China (Nos. 12105187, 11905250 and 11975275)+1 种基金the China Postdoctoral Science Foundation (No. 2021M702245)the Users with Excellence Program of Hefei Science Center, CAS (No. 2021HSC-UE014)。
文摘A novel electromagnetic probe array(EMPA) diagnostic, which consists of a magnetic probe array and an electrostatic probe array, has recently been developed on EAST. The EMPA is fixed near the first wall at horizontal port P. The magnetic probe array of the EMPA consists of 24 identical magnetic probes, each of them capable of measuring toroidal, poloidal and radial magnetic fluctuations simultaneously, providing additional toroidal magnetic fluctuation measurements compared with the regular magnetic probes on EAST. With a higher sampling rate and self-resonant frequency, the EMPA magnetic probes can provide higher frequency magnetic fluctuation measurements. The magnetic probe array of the EMPA is composed of two parallel layers of magnetic probes with a radial distance of 63 mm, and each layer of magnetic probes is arranged in four poloidal rows and three toroidal columns. The compact arrangement of the EMPA magnetic probe array largely improves the toroidal mode number measurement ability from-8≤ n≤ 8 to-112≤ n≤ 112, and also improves the high poloidal wave number measurement ability of magnetic fluctuations compared with the regular high frequency magnetic probes on EAST. The electrostatic probe array of the EMPA consists of two sets of four-tip probes and a single-tip probe array with three poloidal rows and four toroidal columns. It complements the electrostatic parameter measurements behind the main limiter and near the first wall in EAST. The engineering details of the EMPA diagnostic, including the mechanical system, the electrical system, the acquisition and control system, and the effective area calibration, are presented. The preliminary applications of the EMPA in L-mode and H-mode discharges on EAST have demonstrated that the EMPA works well for providing information on the magnetic and electrostatic fluctuations and can contribute to deeper physical analysis in future EAST experiments.
基金supported by National Natural Science Foundation of China(Nos.11827810 and 11875177)International Atomic Energy Agency Research Contract No.22733the National Ten Thousand Talent Program。
文摘The effect of background fluctuation on velocity diagnostics is discussed and studied. The kinetic theory of Mach probe(MP) and the theory of BGK mode are combined to evaluate how the measurement of MP is affected by electrostatics fluctuation. It is found that the quantity of speed by the MP model is closer to the effective velocity in the picture of momentum flux rather than the real mean velocity, while, with high fluctuation, the fitting parameter of MP's exponential formula should be corrected.
文摘Vigorous particle collisions and mechanical processes occurring during high-velocity pneumatic con- veying often lead to particle degradation. The resulting particle size reduction and particle number increase will impact on the flow characteristics, and subsequently affect the electrostatic type of flow measurements. This study investigates this phenomenon using both experimental and numerical meth- ods. Particle degradation was induced experimentally by recursively conveying the fillite material within a pneumatic pipeline. The associated particle size reduction was monitored. Three electrostatic sensors were embedded along the pipeline to monitor the flow. The results indicated a decreasing trend in the electrostatic sensor outputs with decreasing particle size, which suggested the attenuation of the flow velocity fluctuation. This trend was more apparent at higher conveying velocities, which suggested that more severe particle degradation occurred under these conditions. Coupled computational fluid dynamics and discrete element methods (CFD-DEM) analysis was used to qualitatively validate these experimental results. The numerical results suggested that smaller particles exhibited lower flow velocity fluctua- tions, which was consistent with the observed experimental results. These findings provide important information for the accurate aoolication of electrostatic measurement devices in oneumatic conveyors.