期刊文献+
共找到120篇文章
< 1 2 6 >
每页显示 20 50 100
Quantitative detection of Streptococcus mutans from saliva using FTA^(TM) elute cards and real-time polymerase chain reaction
1
作者 Sepideh Seghatoleslami Lars Ohlsson +3 位作者 Kristina Hamberg Peter Carlsson Dan Ericson Lennart Ljunggren 《American Journal of Molecular Biology》 2013年第3期148-152,共5页
Dental caries is a localized, transmissible, pathological infection process that ends up in the destruction of hard dental tissue. Numerous reports have shown the close relationship between salivary levels of Streptoc... Dental caries is a localized, transmissible, pathological infection process that ends up in the destruction of hard dental tissue. Numerous reports have shown the close relationship between salivary levels of Streptococcus mutans and dental caries. As S. mutans, is considered to be the principle etiological agent of dental caries, the development of a quick and convenient method for detection and quantification of these bacteria from patient saliva samples would simplify diagnosis and treatment. The purpose of this study was to compare a new means of quantifying bacteria using FTATM Elute cards and Real-Time Polymerase Chain Reaction to a conventional culture-based assay using oral S. mutans as a model sample. A total of 60 different saliva samples were investigated. The results show a significant negative correlation between the two methods, with a correlation coefficient of -0.577 (Spearman’s Correlation) and p < 0.01. The method demonstrates a high sensitivity, specificity and reliable quantitative results, covering a large range of bacterial concentrations. 展开更多
关键词 Streptococcus mutans FTA^(TM) elute Cards Real-Time PCR
下载PDF
FTA Elute指示卡联合第二代杂交捕获技术用于宫颈癌筛查的有效性研究 被引量:1
2
作者 陈凤 张希 +6 位作者 王少明 胡尚英 陈汶 赵方辉 何微 张雨晴 乔友林 《中华预防医学杂志》 CAS CSCD 北大核心 2015年第2期137-141,共5页
目的探讨FTA Elute指示卡(英国GE公司)联合第二代杂交捕获技术(hybrid capture 2,HC2)在人群中开展宫颈癌筛查的有效性。方法2012年5—6月,选择江西省铜鼓县参与“低成本子宫颈癌分子技术筛查方法研究(LCMCCSS)”项目复查的412... 目的探讨FTA Elute指示卡(英国GE公司)联合第二代杂交捕获技术(hybrid capture 2,HC2)在人群中开展宫颈癌筛查的有效性。方法2012年5—6月,选择江西省铜鼓县参与“低成本子宫颈癌分子技术筛查方法研究(LCMCCSS)”项目复查的412名25~65岁妇女纳入研究。以病理结果为金标准,分别评价医师采样和自我采样时,FTA Elute指示卡和液体管联合HC2检测方法筛查宫颈上皮内瘤变2级及以上病变(CIN2+)的有效性。结果医师采样时,在维持液体管检测灵敏度(12/13)的基础上,FTA Elute指示卡会大幅提高检测的特异度,特异度由69.5%(266/383)增长到77.8%(298/383)(P〈0.001)。自我采样时,FTA Elute指示卡虽会提高检测的特异度,特异度由62.3%(238/382)增长到75.7%(289/382)(P〈0.001),但其灵敏度由液体管的10/13降为8/13(P=0.625)。对于FTA Elute指示卡采样标本,医师和自我采样一致率为86.1%(340/395);对于液体管采样标本,医师和自我采样一致率为79.5%(314/395)。医师通过FTA Elute指示卡采样,筛查效果最优(受试者工作特征曲线下面积=0.898,95%CI:0.838~0.958)。结论FTA Elute指示卡联合HC2法检测筛查宫颈癌具有较好的有效性,通过进一步大样本验证,有望成为卫生资源匮乏地区宫颈癌筛查的有效手段。 展开更多
关键词 宫颈肿瘤 筛查采样方法 人乳头瘤病毒 FTA elute指示卡
原文传递
Superficial femoral artery pseudoaneurysm at implantation site of drug eluting stent discovered due to bacteremia:A case report
3
作者 Takafumi Akai Shintarou Ninomiya Takanori Kaneko 《World Journal of Clinical Cases》 SCIE 2024年第17期3194-3199,共6页
BACKGROUND Drug-eluting stents(DES)are used to treat lower extremity arterial disease.During DES treatment,aneurysmal degeneration occasionally occurs,especially with fluoropolymer-based DES.However,the incidence of p... BACKGROUND Drug-eluting stents(DES)are used to treat lower extremity arterial disease.During DES treatment,aneurysmal degeneration occasionally occurs,especially with fluoropolymer-based DES.However,the incidence of pseudoaneurysms after DES placement is rarely reported in the lower extremity region,although there have been several reports on pseudoaneurysm formation after DES placement in the coronary artery region.CASE SUMMARY We report the case of a 64-year-old man who presented with fever and pain in his left hand after dialysis.Bacteremia was diagnosed by blood culture,and after admission,he developed pain on the medial side of the right thigh.A pseudoaneurysm was observed in the right superficial femoral artery(SFA)at the proximal end of a previously placed DES.The bacteremia was thought to have been caused by a pseudoaneurysm of the left superficial brachial artery,and the pseudoaneurysm of the left superficial brachial artery was removed after antibiotic treatment.The pseudoaneurysm of the right SFA rapidly expanded after admission,but the expansion rate was reduced after infection control.Seven months after the first admission,the pseudoaneurysm of the left SFA was re-moved and in situ revascularization performed using a rifampicin-soaked Dacron graft.CONCLUSION Although pseudoaneurysm after DES placement in the lower extremity region is rare,it must be considered in patients with bacteremia. 展开更多
关键词 PSEUDOANEURYSM Drug eluting stent Superficial femoral artery BACTEREMIA REVASCULARIZATION Case report
下载PDF
Bond Elut PBA固相萃取柱净化-高效液相色谱-串联质谱法同时测定鸡肉中金刚烷胺和利巴韦林的残留量 被引量:2
4
作者 王飞 俞子萱 李淑静 《理化检验(化学分册)》 CAS CSCD 北大核心 2023年第2期172-177,共6页
取鸡肉样品约2.0 g,加入100μg·L^(-1)金刚烷胺-d6和利巴韦林-13C5的混合内标溶液100μL和体积比为7∶3的20 g·L^(-1)三氯乙酸溶液-乙腈的混合溶液15 mL,涡旋30 s,振荡15 min,离心5 min,上层有机相转移至50 mL离心管中。重复... 取鸡肉样品约2.0 g,加入100μg·L^(-1)金刚烷胺-d6和利巴韦林-13C5的混合内标溶液100μL和体积比为7∶3的20 g·L^(-1)三氯乙酸溶液-乙腈的混合溶液15 mL,涡旋30 s,振荡15 min,离心5 min,上层有机相转移至50 mL离心管中。重复上述操作一次,合并上层有机相,过普通滤纸,滤液用约100μL氨水调节酸度至pH 8.5,过活化好的Bond Elut PBA固相萃取柱。固相萃取柱先以体积比1∶9的乙腈-0.25 mol·L^(-1)乙酸铵混合溶液3 mL和含5%(体积分数)氨水的甲醇溶液3 mL淋洗,然后以含2%(体积分数)甲酸的甲醇溶液4 mL洗脱。收集洗脱液,氮吹至干,残渣用体积比1∶9乙腈-水混合溶液1 mL复溶后,过0.22μm滤膜。滤液进入高效液相色谱-串联质谱仪,在Eclipse XDB-C8色谱柱上用不同体积比的含5 mmol·L^(-1)乙酸铵的1%(体积分数)甲酸溶液-甲醇-水的混合溶液梯度洗脱分离其中的金刚烷胺和利巴韦林,在多反应监测模式和电喷雾离子源正离子模式下检测,以内标法定量。结果显示:金刚烷胺和利巴韦林在Eclipse XDB-C8色谱柱上的保留较强,分别在4.30,9.13 min出峰;标准曲线的线性范围均为2~40μg·L^(-1),检出限(3S/N)分别为0.2,0.3μg·kg-1;对空白鸡肉样品进行3个浓度水平的加标回收试验,回收率分别为70.5~84.4%和98.5%~99.6%,测定值的相对标准偏差(n=6)均小于5.0%。 展开更多
关键词 Bond Elut PBA固相萃取柱 高效液相色谱-串联质谱法 利巴韦林 金刚烷胺 残留量 鸡肉
下载PDF
染发剂中2-氨基-4-硝基苯酚和2-氨基-5-硝基苯酚的液相色谱-质谱法测定方法研究 被引量:13
5
作者 于文莲 周新 +3 位作者 张青 陈伟 白桦 陈会明 《分析测试学报》 CAS CSCD 北大核心 2007年第z1期355-356,359,共3页
A new method of 2-amino-4-nitrophenol and 2-amino-5-nitrophenol in hair dye determined by liquid chromatography-mass spectrometry.Chromatographic separation was carried out on a Atlantis C18 (2.1 mm i.d.×150 mm,5... A new method of 2-amino-4-nitrophenol and 2-amino-5-nitrophenol in hair dye determined by liquid chromatography-mass spectrometry.Chromatographic separation was carried out on a Atlantis C18 (2.1 mm i.d.×150 mm,5 μm)column with gradient elution with methanol-acetonitrile at a flow rate 0.2 mL/min.The mass spectrometry was operated in the positive electrospray ionization mode.Quantity was performed using multiple reaction monitoring of the product ion transitions m/z153.0>m/z106(17eV) for 2-amino-4-nitrophenol and m/z153.0>m/z122(15eV) for 2-amino-5-nitrophenol.Linearity of peak was obtained over a range of concentration is from 0.2 to 100 mg/L.The limit is 0.2 mg/L of the method.The proposed method was accurate and rapid with wide linear range.The repeatability and the reproducibility of the method were excellent.It has been applied to detect the real with satisfactory results. 展开更多
关键词 Liquid chromatography Mass spectrometry Gradient elution Hair dye
下载PDF
Purification and Identification of Antifreeze Proteins in Ammopiptanthus mongolicus 被引量:13
6
作者 江勇 魏令波 +2 位作者 费云标 舒念红 高素琴 《Acta Botanica Sinica》 CSCD 1999年第9期967-971,共5页
The conventional protein chromatography technique was adopted to purify the antifreeze proteins (AFPs) from the leaves of Ammopiptanthus mongolicus (Maxim.) Cheng f. Two bands on native PAGE gel showed thermal hys... The conventional protein chromatography technique was adopted to purify the antifreeze proteins (AFPs) from the leaves of Ammopiptanthus mongolicus (Maxim.) Cheng f. Two bands on native PAGE gel showed thermal hysteresis activity, one was band B1, whose thermal hysteresis was 0.46 ℃ at 8 g/L, which showed two bands (67 kD, 21 kD) on SDS_PAGE gel; the other was B3, whose thermal hysteresis was 0.45 ℃ at 10 g/L, and it contained only a single protein (39.8 kD). Both B1 and B3 are not glycoproteins, because neither do they interact with Shiff_reagent, nor show ultraviolet characteristics of a typical glycoprotein. 展开更多
关键词 Ammopiptanthus mongolicus Antifreeze proteins CHROMATOGRAPHY Electrophoresis elution
下载PDF
安捷伦7000三重串联四极杆气质联用仪一次进样同时检测大葱中170种农药残留 被引量:11
7
作者 王雯雯 刘畅 《环境化学》 CAS CSCD 北大核心 2011年第10期1822-1827,共6页
建立了使用安捷伦7000三重串联四极杆气质联用仪一次进样同时测定大葱中170种农药残留的分析方法.样品采用乙腈匀浆提取,经氯化钠盐析离心后,用Agilent Bond Elut Carbon/NH2柱净化,使用乙腈/甲苯(3∶1,V/V)洗脱,经DB-1701气相色谱柱分... 建立了使用安捷伦7000三重串联四极杆气质联用仪一次进样同时测定大葱中170种农药残留的分析方法.样品采用乙腈匀浆提取,经氯化钠盐析离心后,用Agilent Bond Elut Carbon/NH2柱净化,使用乙腈/甲苯(3∶1,V/V)洗脱,经DB-1701气相色谱柱分离,在三重串联四极杆多反应监测模式下进行测定.40 min内即可完成大葱中170种农残检测.本方法采用外标法定量,绝大多数农药在0.01 mg·L-1的浓度下能够检出,线性范围在0.01 mg·L-1到0.50 mg·L-1间,90%农药的线性相关系数大于0.995.在0.01 mg·kg-1的添加水平进行农药回收率的五次平行测定,其中88%的农药平均回收率在80.0%—130.0%之间,97%的农药相对标准偏差小于20%.方法操作简单、快速、灵敏度高,能够对大葱当中痕量多组分农药残留进行准确的定性和定量分析. 展开更多
关键词 安捷伦7000三重串联四极杆气质联用仪 BOND Elut Carbon/NH2固相萃取柱 大葱 农药多残留
下载PDF
冠心病患者双联抗血小板治疗策略进展——ACC/AHA冠心病患者双联抗血小板治疗指南更新解读 被引量:17
8
作者 沈迎 张瑞岩 沈卫峰 《心脑血管病防治》 2016年第3期169-170,173,共3页
在当前临床心脏病领域中,双联抗血小板治疗(dual antiplatelet therapy,DAPT)已被广泛应用于稳定型缺血性心脏病、急性冠状动脉(冠脉)综合征、冠脉旁路移植术(CABG)后或接受经皮冠脉介入治疗(PCI)患者的管理。
关键词 双联 ACC/AHA 药物洗脱支架 冠脉旁路移植术 eluting STENT 急性冠脉综合征 缺血性心脏病 随机对照试验 血栓形成
下载PDF
药物涂层支架的研究进展 被引量:4
9
作者 赵琪 冉峰 《中国血管外科杂志(电子版)》 2017年第2期156-160,共5页
动脉粥样硬化(atherosclerosis,AS)是冠心病、脑梗死、外周血管病的主要原因,是危害人类健康的主要疾病之一。经皮血管腔内成形术(percutaneous transluminal angiography,PTA)包括球囊成形术、支架植入术、斑块旋切术等,已成为AS... 动脉粥样硬化(atherosclerosis,AS)是冠心病、脑梗死、外周血管病的主要原因,是危害人类健康的主要疾病之一。经皮血管腔内成形术(percutaneous transluminal angiography,PTA)包括球囊成形术、支架植入术、斑块旋切术等,已成为AS的重要治疗手段。但支架植入术长期受限于支架内再狭窄(in-stent restenosis,ISR),金属裸支架(bare metal stent,BMS)植入术后20%~30%的患者会发生ISR,成为介入治疗面临的重要问题[1]。 展开更多
关键词 药物涂层支架 支架植入术 STENT 金属裸支架 支架内再狭窄 RESTENOSIS eluting 聚合物涂层支架 支架内血栓 支架材料
下载PDF
非均匀药物涂层支架初步研究
10
作者 孙安强 赵宜鹏 +1 位作者 王振泽 邓小燕 《医用生物力学》 EI CAS CSCD 北大核心 2013年第S1期122-122,共1页
动脉血管支架介入治疗具有手术创伤小、见效快、病人恢复时间短等诸多优点,成为治疗血管狭窄的主要手段之一。特别是药物涂层支架(drug eluting stent,DES)的出现将血管介入治疗带入了一个崭新的时代<sup>[1]</sup>。药... 动脉血管支架介入治疗具有手术创伤小、见效快、病人恢复时间短等诸多优点,成为治疗血管狭窄的主要手段之一。特别是药物涂层支架(drug eluting stent,DES)的出现将血管介入治疗带入了一个崭新的时代<sup>[1]</sup>。药物涂层支架上缓释出来的药物可以起到抗血栓、抗炎症、抗细胞增殖等作用,显著提高支架植入后的近期通畅率。血流动力学研究发现,血管内的血流动力学特征对药物涂层支架植入后的药物缓释规律、药物传输和分布规律均产生明显的影响<sup>[2]</sup>。 展开更多
关键词 药物涂层支架 eluting 介入治疗 血流动力学研究 支架植入 STENT 血液流动 药物传输 血管支架 药物缓释
下载PDF
Analysis of the effect of sirolimus-eluting stent on diabetes
11
作者 吴小凡 柳弘 宋现涛 《心肺血管病杂志》 CAS 2010年第S1期68-68,共1页
Objective:To evaluate the effect of diabetes on outcome of sirolimus-eluting stent.Methods:From December 2002 to May 2005,262 diabetes and 262 non-diabetics treated with sirolimus-eluting stents were studied.The follo... Objective:To evaluate the effect of diabetes on outcome of sirolimus-eluting stent.Methods:From December 2002 to May 2005,262 diabetes and 262 non-diabetics treated with sirolimus-eluting stents were studied.The follow-up angiography was performed in 8-month.Major adverse cardiac events(MACE)defined as death,myocardial infarction,or target lesion revascularization and follow-up angiography were analyzed.Results:Successful rate of stent implantation was 100%.There was no death during the procedure,hospitalization,and follow-up period.Acute myocardial infarction occurred in 1 diabetic at 2 days after PCI,and in 2 non-diabetics at follow-up period.Angiographic follow up at 8 months showed that absolute late lumen loss was 0.06 vs 0.04mm(P>0.05),relative late lumen loss was 2.32% vs 1.63%,and TLR rate was 12.60% vs 9.92% in diabetic group and non-diabetic group respectively.Logistic regression analysis showed that reference vessel lumen and relative late lumen loss were significantly associated with restenosis.Conclusion:Cypher stent implantation in diabetes is safe and effective,while relative late lumen loss may be related to restenosis.In a word,diabetes with small vessel may be considered to be risk factor for restenosis after Cypher stents implantation. 展开更多
关键词 eluting STENT RESTENOSIS IMPLANTATION LUMEN ABSOLUTE Major
下载PDF
梯度洗脱层析法
12
作者 董纪昌 沈竞康 《医药工业》 CAS 1988年第5期235-236,195+208,共4页
层析法已广泛应用于分离纯化合成或天然的产物。一般的柱层析虽可用于分离各种结构类型的化合物,但对于在结构上近似、极性相差不大的混合物分离效率较差。应用梯度洗脱的柱层析法可提高分离效率,有时会取得满意的结果。
关键词 gradient elution column chromatography SEPARATION
下载PDF
采用新型固相萃取柱快速测定食用植物油中苯并[a]芘 被引量:14
13
作者 何强 孔祥虹 +2 位作者 李建华 赵洁 张莹 《分析测试学报》 CAS CSCD 北大核心 2012年第6期710-714,共5页
研究了Bond Elut ENV新型固相萃取柱在食用植物油中苯并[a]芘快速检测中的应用,建立了快速测定食用植物油样品中苯并[a]芘残留量的固相萃取/液相色谱/荧光检测法。样品用正己烷溶解,固相萃取净化,SUPELCOSILTMLC-PAH(25 cm×4.6 mm,... 研究了Bond Elut ENV新型固相萃取柱在食用植物油中苯并[a]芘快速检测中的应用,建立了快速测定食用植物油样品中苯并[a]芘残留量的固相萃取/液相色谱/荧光检测法。样品用正己烷溶解,固相萃取净化,SUPELCOSILTMLC-PAH(25 cm×4.6 mm,5μm)色谱柱分离,以乙腈-水(95∶5)为流动相,荧光检测(λex=297 nm,λem=408 nm),外标法定量。苯并[a]芘的检出限为0.3μg/kg,在1.0~50.0μg/L范围内线性关系良好,相关系数为0.999 6,方法的回收率为79%~102%,相对标准偏差不高于9.4%。该方法准确、实用、简便、快速,在食用植物油的苯并[a]芘残留量检测方面有广泛的应用前景。 展开更多
关键词 BOND Elut ENV固相萃取柱 食用植物油 苯并[A]芘 硅胶固相萃取柱 液相色谱/荧光检测
下载PDF
载药球囊在下肢动脉疾病中的应用 被引量:1
14
作者 毛荣富 符伟国 +3 位作者 徐欣 杨珏 竺挺 岳嘉宁 《中国血管外科杂志(电子版)》 2014年第2期118-120,共3页
1974年,Gruentzig在苏黎世进行了第一例经皮血管成形术(percutaneous transluminal angioplasty,PTA),至今数十年间,球囊扩张已成为外周动脉疾病(peripheral artery disease,PAD)手术的一个重要步骤。随着球囊、导丝等器械的不断发展和... 1974年,Gruentzig在苏黎世进行了第一例经皮血管成形术(percutaneous transluminal angioplasty,PTA),至今数十年间,球囊扩张已成为外周动脉疾病(peripheral artery disease,PAD)手术的一个重要步骤。随着球囊、导丝等器械的不断发展和改善,球囊扩张和支架成形术后再狭窄,始终是这项微创术的一个主要缺陷。载药球囊(drug-eluting balloon, 展开更多
关键词 再狭窄 下肢动脉疾病 支架成形术 eluting 微创术 外周动脉疾病 ANGIOPLASTY 冠状动脉病 靶病变 冠脉疾病
下载PDF
固相萃取法提取典型海水溶解有机质及其红外光谱和固态^(13)C核磁共振表征 被引量:1
15
作者 武奕鑫 王孝聪 +3 位作者 周振淞 何晨 潘良浩 宋桂雪 《海洋与湖沼》 CAS CSCD 北大核心 2022年第6期1360-1369,共10页
由于海水盐度大、有机质含量低,从海水中提取和纯化克级溶解性有机质(dissolved organic matter,DOM)一直十分困难。基于Bond Elut PPL固相萃取小柱法进行海水DOM固体样品提取的放大试验,建立DOM自动化调酸、PPL树脂吸附技术,最后形成... 由于海水盐度大、有机质含量低,从海水中提取和纯化克级溶解性有机质(dissolved organic matter,DOM)一直十分困难。基于Bond Elut PPL固相萃取小柱法进行海水DOM固体样品提取的放大试验,建立DOM自动化调酸、PPL树脂吸附技术,最后形成提纯、冷冻干燥PPL-DOM(通过PPL树脂提取的DOM)完整工艺。采用元素分析、三维荧光光谱、红外光谱和固态^(13)C核磁共振(NMR)波谱法进行样品表征。结果表明:(1)该方法对近海表层海水DOM回收率稳定在50%以上,搭建的提取装置DOM日吸附量可达230 mg;(2)鳌山湾四个季节批次PPL-DOM整体分析结果表明,样品的元素组成和光谱特征相似,表明方法适用性和稳定性较好;(3)三种水生态环境的PPL-DOM^(13)C NMR谱图显示样品的基本特征相似,以烷基碳、碳水化合物碳、芳香碳和羧基碳/酰胺碳为主,其中偶极去相(dipolar dephasing)谱显示了DOM前体化合物来源的差异。多种结果表明放大后的PPL固相萃取法可稳定提取克级DOM样品。 展开更多
关键词 海洋溶解性有机质 固相萃取 Bond Elut PPL 固态^(13)C核磁共振 红外光谱
下载PDF
Isolation of Lysozyme from Chicken Egg White Using Polyacrylamide-based Cation-exchange Cryogel 被引量:13
16
作者 晏禄丁 沈绍传 +1 位作者 贠军贤 姚克俭 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第5期876-880,共5页
An effective cation-exchange chromatographic method for lysozyme isolation from chicken egg white is presented, using supermacroporous cryogel grafted with sulfo functional groups. The chromatographic processes were c... An effective cation-exchange chromatographic method for lysozyme isolation from chicken egg white is presented, using supermacroporous cryogel grafted with sulfo functional groups. The chromatographic processes were carried out by one-step and sequential elution, respectively. Sodium phosphate buffer (pH 7.8) containing different concentrations of NaC1 is used as elution agent. The corresponding breakthrough characteristics and elution behaviors in the cryogel bed were investigated and analyzed. Purity of lysozyme in the elution effluent was assayed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). The maximum purity of the obtained lysozyme was about 96%, and the cryogel is demonstrated as a potential separation medium for purification of high-purit lysozyme from chicken egg white. 展开更多
关键词 cation-exchange cryogel.iysozyme ISOLATION sequential elution chicken egg white
下载PDF
Advantages and disadvantages of biodegradable platforms in drug eluting stents 被引量:7
17
作者 Agustina Rodriguez-Granillo Bibiana Rubilar +1 位作者 Gaston Rodriguez-Granillo Alfredo E Rodriguez 《World Journal of Cardiology》 CAS 2011年第3期84-92,共9页
Coronary angioplasty with drug-eluting stent(DES)implantation is currently the most common stent procedure worldwide.Since the introduction of DES,coronary restenosis as well as the incidence of target vessel and targ... Coronary angioplasty with drug-eluting stent(DES)implantation is currently the most common stent procedure worldwide.Since the introduction of DES,coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced.However,the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to baremetal stent(BMS)implantation.Several factors have been associated with very late stent thrombosis after DES implantation,such as delayed healing,inflammation,stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers,which were essential to allow the elution of the immunosuppressive drug in the first DES designs.The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug,after which a BMS remains in place.Several DES designs with biodegradable(BIO)polymers have been introduced in preclinical and clinical studies, including randomized trials.In this review,we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology. 展开更多
关键词 POLYMERS Drug eluting STENTS BIODEGRADABLE POLYMERS STENTS THROMBOSIS RESTENOSIS
下载PDF
Removal of Cd(II) by Nanometer AIO(OH) Loaded on Fiberglass with Activated Carbon Fiber Felt as Carrier 被引量:5
18
作者 刘光辉 王培培 +1 位作者 刘琼 韩炜 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第5期805-811,共7页
A new nanometer material, nanometer AlO(OH) loaded on the fiberglass with activated carbon fibers felt(ACF) as the carrier, was prepared by hydrolytic reaction for the removal of Cd(II) from aqueous solution usi... A new nanometer material, nanometer AlO(OH) loaded on the fiberglass with activated carbon fibers felt(ACF) as the carrier, was prepared by hydrolytic reaction for the removal of Cd(II) from aqueous solution using column adsorption experiment. As was confirmed by XRD determination, the hydrolysis production loaded on fiberglass was similar to the orthorhombic phase AlO(OH). SEM images showed that AlO(OH) particles were in the form of small aggregated clusters. The Thomas model was applied for estimating the kinetic parameters and the saturated adsorption ability of Cd(II) adsorption on the new adsorbent. The results showed that the maximum adsorption capacity of Cd(II) was 128.50 mg·g^-1 and 117.86 mg·g^-1 for the adsorbent mass of 0.3289 g and the adsorbent mass of 0.2867 g, respectively. The elution experiment result indicated that the adsorbed Cd ions was easily desorbed from the material with 0.1 mol·L^-1 HCl solution. Adsorption-desorption cycles showed the feasibility of repealed uses of the composited material. The adsorption capacities were influenced by pH and the initial Cd(II) concentration. The amount adsorbed was greatest at pH 6.5 and the initial Cd(II) concentration of 0.07 mg·L^-1, respectively. Nanometer AlO(OH) played a major role in the adsorption process, whereas the fiberglass and ACF were assistants in the process of removing Cd(II). In addition, the adsorption capacities for Cd(II) were obviously reduced from 128.50 mg·L^-1 to 64.28 mg·L^-1 when Pb ions were present because Pb ions took up more adsorption sites. 展开更多
关键词 REMOVAL Cd(II) nanometer AlO(OH) adsorption and elution mechanism
下载PDF
Grouping separation of mixed rare earths from their coexisting aqueous solutions by liquid-column elution 被引量:3
19
作者 Wenjuan Cao Kun Huang +1 位作者 Xiaoqin Wang Huizhou Liu 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第8期1828-1836,共9页
A new approach was proposed for grouping separation of 14 lanthanide rare-earth ions from their coexisting mixed aqueous solutions, by performing liquid-column elution using the aqueous solution containing 14 lanthani... A new approach was proposed for grouping separation of 14 lanthanide rare-earth ions from their coexisting mixed aqueous solutions, by performing liquid-column elution using the aqueous solution containing 14 lanthanide rare-earth ions as the stationary phase and the dispersed organic oil droplets containing P507 extractant as the mobile phase. It was revealed that 14 lanthanide rare-earth ions could be separated into four groups, according to the lanthanide tetrad effect, respectively eluting out from the liquid column at different time in a certain order. Various effects including the saponification degree of P507, the concentration of P507 in organic phase, the length and inner diameter of the extraction column on the performance of grouping separation of rare-earth ions were discussed. The changes of the mass transfer coefficients were also investigated. The separation efficiency of the four groups of rareearth elements(REEs) was evaluated based on the elution resolution, Rs, of the elution peaks of La(Ⅲ),Gd(Ⅲ), Ho(Ⅲ) and Lu(Ⅲ), the four representative elements respectively from each of the four groups of REEs. Experimental results demonstrated that the separation of REEs by liquid-column elution mainly depended on the competitive adsorption of different rare-earth groups onto the surface of ascending P507 oil droplets. The affinity of different rare-earth groups with P507 extractant and a limited adsorption capacity of P507 molecules at the surface of the oil droplets ascending in liquid column play the important role. The present work highlights a promising technique for grouping separation of multiple lanthanide elements co-existing complex systems. 展开更多
关键词 ELUTION LANTHANIDE TETRAD effect RARE-EARTHS Group SEPARATION
下载PDF
Development and validation of a stability indicating RP-HPLC method for the determination of Rufinamide 被引量:4
20
作者 B.Sai Pavan Kumar M.Mathrusri Annapurna S.Pavani 《Journal of Pharmaceutical Analysis》 SCIE CAS 2013年第1期66-70,共5页
A stability-indicating RP-HPLC method was developed and validated lbr the determination of Rufinamide in tablet dosage forms using C 18 column (250 mm x 4.6 mm, 5 μm) wilh mobile phase consisting of water acetonitr... A stability-indicating RP-HPLC method was developed and validated lbr the determination of Rufinamide in tablet dosage forms using C 18 column (250 mm x 4.6 mm, 5 μm) wilh mobile phase consisting of water acetonitrile (40:60, v/v) with a [low rate of 0.8 mL/min (UV detection 215 nm). Linearity was observed over the concentration range 1.0 200 μg/mL (R2=0.9997) with regression equation y-113190 x+63053. Rufinamide was subjected to stress conditions including acidic, alkaline, oxidation, photolysis and thermal degradation. Rufinaraide is more sensitive towards acidic degradation. The method was validated as per ICH guidelines. 展开更多
关键词 RUFINAMIDE Reversed-phase HPLCIsocratic elution VALIDATION STABILITY-INDICATING
下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部