期刊文献+
共找到8,028篇文章
< 1 2 250 >
每页显示 20 50 100
Rim^(18)F-fluorodeoxyglucose uptake of hepatic cavernous hemangioma on positron emission tomography/computed tomography:A case report
1
作者 Yong-An Hu Ya-Xin Guo Qi-Feng Huang 《World Journal of Clinical Cases》 SCIE 2024年第13期2243-2247,共5页
BACKGROUND Peripheral FDG accumulation in a hepatic hemangioma presenting in a patient with prolonged fever is rare.Therefore,clinicians should pay close attention to patients with hepatic mass.CASE SUMMARY A 54-year-... BACKGROUND Peripheral FDG accumulation in a hepatic hemangioma presenting in a patient with prolonged fever is rare.Therefore,clinicians should pay close attention to patients with hepatic mass.CASE SUMMARY A 54-year-old woman with a 4-wk history of daily fevers was admitted to our hospital.A whole body^(18)-Fluordesoxyglucose(PET-FDG)positron emission tomography/computed tomography(PET/CT)was performed to elucidate the source of the fever.However,whole body^(18)-FDG PET/CT raised the suspicion of a malignant lesion because of peripheral FDG accumulation(SUVmax 3.5 g/mL)higher than that of the normal liver parenchyma(SUVmax 1.6 g/mL)surrounding a hypoactive area,and no other abnormalities were showed.Subsequently,the patient underwent liver mass resection.Histopathology showed a hepatic cavernous hemangioma with fatty infiltration around the lesion.The fever disappeared four days after surgery and the patient did not present any complications during follow-up.CONCLUSION Fatty infiltration in the peripheral parts of hepatic cavernous hemangioma may lead to subacute inflammation which further activate the Kupffer cells.This may cause prolonged fever and peripheral rim FDG accumulation on PET/CT. 展开更多
关键词 ^(18)-Fluordesoxyglucose positron emission tomography/computed tomography Hepatocellular carcinoma FEVER Fatty infiltration Case report
下载PDF
Guiding function of positron emission tomographycomputed tomography examination in the diagnosis and treatment of ocular adnexal mucosa associated lymphoid tissue lymphoma
2
作者 Xuan Zhang Qi-Han Guo +3 位作者 Rui Liu Jing Li Ying-Chao Li Jian-Min Ma 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期693-699,共7页
AIM:To explore the role of positron emission tomographycomputed tomography(PET-CT)examination in the diagnosis and treatment of ocular adnexal mucosa associated lymphoid tissue lymphoma(OAML).METHODS:The general clini... AIM:To explore the role of positron emission tomographycomputed tomography(PET-CT)examination in the diagnosis and treatment of ocular adnexal mucosa associated lymphoid tissue lymphoma(OAML).METHODS:The general clinical data,postoperative PET-CT results,treatment regimens,and the prognosis of 21 histopathologically confirmed OAML patients between October 2017 and September 2021 were collected.Among the 21 patients,five patients underwent surgical treatment alone,13 patients underwent surgical treatment combined with radiotherapy,and three patients underwent surgical treatment combined with chemotherapy.RESULTS:The follow-up period ranged from 8 to 79mo,with four cases of recurrence and no deaths.Through PETCT examination,two patients exhibited both local ocular metabolic elevation and systemic metastasis,and one of these patients had cervical lymph node metastasis,while the other had submandibular and parotid gland metastasis.Nine patients showed only local ocular metabolic elevation,while 10 patients had no abnormal metabolic activity locally.CONCLUSION:PET-CT examination plays a crucial role in detecting residual lesions and recurrence following tumor resection,aiding in precise disease staging,and facilitating the development of personalized treatment plans,ultimately improving patient prognosis. 展开更多
关键词 ocular adnexal mucosa associated lymphoid tissue lymphoma positron emission tomographycomputed tomography ocular tumors
下载PDF
Application of ^(18)F-fluorodeoxyglucose positron emission tomography/computed tomography imaging in recurrent anastomotic tumors after surgery in digestive tract tumors
3
作者 Deng-Feng Ge Hao Ren +4 位作者 Zi-Chen Yang Shou-Xiang Zhao Zhen-Ting Cheng Da-Da Wu Bin Zhang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第8期2474-2483,共10页
BACKGROUND This study was to investigate the application value of whole-body dynamic ^(18)F-fluorodeoxyglucose(FDG)positron emission tomography/computed tomogra-phy(PET/CT)imaging in recurrent anastomotic tumors of di... BACKGROUND This study was to investigate the application value of whole-body dynamic ^(18)F-fluorodeoxyglucose(FDG)positron emission tomography/computed tomogra-phy(PET/CT)imaging in recurrent anastomotic tumors of digestive tract after gastric and esophageal cancer surgery.Postoperative patients with gastric and esophageal cancer have a high risk of tumor recurrence,and traditional imaging methods have certain limitations in early detection of recurrent tumors.Whole-body dynamic ^(18)F-FDG PET/CT imaging,due to its high sensitivity and specifi-city,can provide comprehensive information on tumor metabolic activity,which is expected to improve the early diagnosis rate of postoperative recurrent tumors,and provide an important reference for clinical treatment decision-making.METHODS A retrospective analysis was performed on 53 patients with upper digestive tract tumors after operation and systemic dynamic ^(18)F-FDG PET/CT imaging indi-cating abnormal FDG uptake by anastomosis,including 29 cases of gastric cancer and 24 cases of esophageal cancer.According to the follow-up results of gas-troscopy and other imaging examinations before and after PET/CT examination,the patients were divided into an anastomotic recurrence group and anastomotic inflammation group.Patlak multi-parameter analysis software was used to obtain the metabolic rate(MRFDG),volume of distribution maximum(DVmax)of anastomotic lesions,and MRmean and DVmean of normal liver tissue.The lesion/background ratio(LBR)was calculated by dividing the MRFDG and DVmax of the anastomotic lesion by the MRmean and DVmean of the normal liver tissue,respectively,to obtain LBR-MRFDG and LBR-DVmax.An independent sample t test was used for statistical analysis,and a receiver operating characteristic curve was used to analyze the differential diagnostic efficacy of each parameter for anastomotic recurrence and inflammation.RESULTS The dynamic ^(18)F-FDG PET/CT imaging parameters MRFDG,DVmax,LBR-MRFDG,and LBR-DVmax of postoperative anastomotic lesions in gastric cancer and esophageal cancer showed statistically significant differences between the recurrence group and the inflammatory group(P<0.05).The parameter LBR-MRFDG showed good diagnostic efficacy in differentiating anastomotic inflammation from recurrent lesions.In the gastric cancer group,the area under the curve(AUC)value was 0.935(0.778,0.993)when the threshold was 1.83,and in the esophageal cancer group,the AUC value was 1.When 86 is the threshold,the AUC value is 0.927(0.743,0.993).CONCLUSION Whole-body dynamic ^(18)F-FDG PET/CT imaging can accurately differentiate the diagnosis of postoperative anastomotic recurrence and inflammation of gastric cancer and esophageal cancer and has the potential to be an effective monitoring method for patients with upper digestive tract tumors after surgical treatment. 展开更多
关键词 Gastric cancer Esophageal cancer ANASTOMOSIS Dynamic positron emission tomography Differential diagnosis Metabolic rate
下载PDF
Recent progress in the applications of presynaptic dopaminergic positron emission tomography imaging in parkinsonism
4
作者 Yujie Yang Xinyi Li +7 位作者 Jiaying Lu Jingjie Ge Mingjia Chen Ruixin Yao Mei Tian Jian Wang Fengtao Liu Chuantao Zuo 《Neural Regeneration Research》 SCIE CAS 2025年第1期93-106,共14页
Nowadays,presynaptic dopaminergic positron emission tomography,which assesses deficiencies in dopamine synthesis,storage,and transport,is widely utilized for early diagnosis and differential diagnosis of parkinsonism.... Nowadays,presynaptic dopaminergic positron emission tomography,which assesses deficiencies in dopamine synthesis,storage,and transport,is widely utilized for early diagnosis and differential diagnosis of parkinsonism.This review provides a comprehensive summary of the latest developments in the application of presynaptic dopaminergic positron emission tomography imaging in disorders that manifest parkinsonism.We conducted a thorough literature search using reputable databases such as PubMed and Web of Science.Selection criteria involved identifying peer-reviewed articles published within the last 5 years,with emphasis on their relevance to clinical applications.The findings from these studies highlight that presynaptic dopaminergic positron emission tomography has demonstrated potential not only in diagnosing and differentiating various Parkinsonian conditions but also in assessing disease severity and predicting prognosis.Moreover,when employed in conjunction with other imaging modalities and advanced analytical methods,presynaptic dopaminergic positron emission tomography has been validated as a reliable in vivo biomarker.This validation extends to screening and exploring potential neuropathological mechanisms associated with dopaminergic depletion.In summary,the insights gained from interpreting these studies are crucial for enhancing the effectiveness of preclinical investigations and clinical trials,ultimately advancing toward the goals of neuroregeneration in parkinsonian disorders. 展开更多
关键词 aromatic amino acid decarboxylase brain imaging dopamine transporter Parkinson’s disease PARKINSONISM positron emission tomography presynaptic dopaminergic function vesicle monoamine transporter type 2
下载PDF
Technetium-99m-methylene diphosphonate single photon emission computed tomography/computed tomography combined with prostate-specific antigen/free prostate-specific antigen ratio for bone metastasis of prostate cancer
5
作者 Jian He Yi-Pu Zhong Shuang Zhang 《World Journal of Clinical Cases》 SCIE 2024年第20期4082-4090,共9页
BACKGROUND Prostate cancer(PC)is one of the most common malignant tumors in men,and bone metastasis is one of its common complications,which seriously affects the quality of life and prognosis of patients.AIM To inves... BACKGROUND Prostate cancer(PC)is one of the most common malignant tumors in men,and bone metastasis is one of its common complications,which seriously affects the quality of life and prognosis of patients.AIM To investigate the diagnostic value of technetium-99m-methylene diphosphonate(99mTc-MDP)single photon emission computed tomography(SPECT)/CT imaging combined with the serum prostate-specific antigen(PSA)/free PSA ratio for PC bone metastasis(PCBM).METHODS One hundred patients with PC who visited the Hospital of Chengdu University of Traditional Chinese Medicine from January 2020 to January 2022 were recruited as the experimental(Exp)group,while 30 patients with benign prostatic lesions(BPLs)were recruited as the control(Ctrl)group.All patients underwent 99mTc-MDP SPECT/CT imaging and serum PSA/fPSA testing.The SPECT/CT imaging results and serum PSA/fPSA ratios of patients were analyzed to evaluate their diagnostic values for PCBM.RESULTS The difference in general information of the patients was not obvious,showing comparability.The two methods showed no visible differences in negative predictive value and sensitivity for patients with PCBM,but had great differences in positive predictive value and specificity(P<0.05).The PSA/fPSA ratio of patients with PC in the Exp group was lower than those with BPLs,and patients with PCBM had a much lower PSA/fPSA ratio than those without PC(P<0.05).The results confirmed that the combined use of 99mTc-MDP SPECT/CT imaging and serum PSA/fPSA ratio achieved a detection rate of 95%for PCBM.CONCLUSION The combination of 99mTc-MDP SPECT/CT and PSA/fPSA ratio is accurate and reliable for the diagnosis of PCBM,which provides an important reference for clinical practice. 展开更多
关键词 Matrix metalloproteinase 9 Single photon emission computed tomography Prostate-specific antigen to free prostate-specific antigen ratio Prostate cancer Bone metastasis
下载PDF
Utility of Preoperative Positron Emission Tomography (PET) in Localizing Perforator Vessels of Anterolateral Thigh Free Flap
6
作者 Alexandra McMillan Sameer A. Alvi +3 位作者 Zaid Al-Qurayshi Zachary Fleishacker Nitin A. Pagedar Marisa R. Buchakjian 《International Journal of Otolaryngology and Head & Neck Surgery》 2024年第4期275-284,共10页
Objectives: The anterolateral thigh (ALT) flap is often considered the workhorse in soft tissue reconstruction of head and neck defects secondary to trauma, infection, or tumor resection. Despite its many advantages, ... Objectives: The anterolateral thigh (ALT) flap is often considered the workhorse in soft tissue reconstruction of head and neck defects secondary to trauma, infection, or tumor resection. Despite its many advantages, ALT flaps have been criticized due to variability in vasculature, which may result in inadequate or non-existent perforators. This retrospective study aims to investigate the utility and validity of positron emission tomography (PET) scan to identify the location and characteristics of perforators to the ALT flap. Methods: We performed a 10-year retrospective review of ALT flaps at our institution to identify patients with preoperative PET scans available for analysis. Three reviewers (attending physician, fellow, and resident) were asked to identify the number, location, and characteristics (myocutaneous versus septocutaneous) of ALT perforators on imaging, and reviewer agreement was assessed. Results were then compared to available operative data. Results: One hundred twenty-one patients were identified who underwent ALT free flap surgery. Thirty-eight preoperative PET scans were identified for review. At least one perforator was identified in 92.1% of scans. Agreement percentages regarding the number of perforators ranged from 53% - 61% whereas agreement regarding the location of a single perforator ranged from 79% - 90%. However, reviewers did not agree regarding the type of perforator, with agreement ranging from 34% - 53%. Poor agreement was observed when compared to intraoperative data, with the number of perforators ranging from 26% - 34% and the type of perforator 11% - 24%. These findings are likely due to insufficient data available in operative reports. Conclusion: Although initial studies suggest that PET scan shows promising evidence to support the capacity to preoperatively identify ALT perforators, future prospective studies are warranted to fully validate these findings. 展开更多
关键词 Anterolateral Thigh Flaps Positron emission tomography Head and Neck Defects Perforator Mapping
下载PDF
Pancreatic neuroendocrine tumor detected by technetium-99m methoxy-2-isobutylisonitrile single photon emission computed tomography/computed tomography:A case report
7
作者 Chang-Jiang Liu Hua-Jun Yang +1 位作者 Yan-Chun Peng De-Yu Huang 《World Journal of Clinical Cases》 SCIE 2023年第12期2825-2831,共7页
BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging mod... BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging modalities for the diagnosis of pancreatic NETs.Furthermore,somatostatin receptor imaging is of great value for diagnosing pancreatic NETs.Herein,we report the efficacy of technetium-99m methoxy-2-isobutylisonitrile(99mTc-MIBI)single photon emission CT(SPECT)/CT for detecting pancreatic NETs.CASE SUMMARY A 57-year-old woman presented to our hospital with a 1-d history of persistent upper abdominal distending pain.The distending pain in the upper abdomen was aggravated after eating,with nausea and retching.Routine blood test results showed a high neutrophil percentage,low leukomonocyte and monocyte percentages,and low leukomonocyte and eosinophil counts.Amylase,liver and kidney function,and tumor markers alpha-fetoprotein,carcinoembryonic antigen,and cancer antigen(CA)125,CA72-4,CA19-9,and CA153 were normal.Abdominal CT showed a mass,with multiple calcifications between the pancreas and the spleen.The boundary between the mass and the pancreas and spleen was poorly defined.Contrast-enhanced CT revealed that the upper abdominal mass was unevenly and gradually enhanced.99mTc-MIBI SPECT/CT revealed that a focal radioactive concentration,with mild radioactive concentration extending into the upper abdominal mass,was present at the pancreatic body and tail.The 99mTc-MIBI SPECT/CT manifestations were consistent with the final pathological diagnosis of pancreatic NET.CONCLUSION 99mTc-MIBI SPECT/CT appears to be a valuable tool for detecting pancreatic NETs. 展开更多
关键词 Neuroendocrine tumors PANCREAS Tc-99m-Methoxy-2-isobutylisonitrile Single photon emission computed tomography X-ray computed tomography Case report
下载PDF
Polyarteritis nodosa presenting as leg pain with resolution of positron emission tomography-images:A case report
8
作者 Ji-Hyoun Kang Jahae Kim 《World Journal of Clinical Cases》 SCIE 2023年第4期918-921,共4页
BACKGROUND Although fluorodeoxyglucose-positron emission tomography/computed tomography(FDG-PET/CT)is widely used for diagnosis and follow-up of large sized vessel vasculitis,it is still not widely used for small to m... BACKGROUND Although fluorodeoxyglucose-positron emission tomography/computed tomography(FDG-PET/CT)is widely used for diagnosis and follow-up of large sized vessel vasculitis,it is still not widely used for small to medium sized vessel vasculitis.CASE SUMMARY This is the case of a 68-year-old male who presented at the emergency department complaining of fever,myalgia,and bilateral leg pain of over two weeks duration,with elevated levels of C-reactive protein.He was subsequently admitted and despite the absence of clinically significant findings,the patient continued to exhibit recurrent fever.A fever of unknown origin workup,which included imaging studies using FDG-PET/CT,revealed vasculitis involving small to medium-sized vessels of both lower extremities,demonstrated by linear hypermetabolism throughout the leg muscles.The patient was treated with methylprednisolone and methotrexate after diagnosis leading to the gradual resolution of the patient’s symptoms.Three weeks later,a follow-up FDGPET/CT was performed.Previously hypermetabolic vessels were markedly improved.CONCLUSION Our case report demonstrated that FDG-PET/CT has tremendous potential to detect medium-sized vessel inflammation;it can also play a crucial role in prognosticating outcomes and monitoring therapeutic efficacy. 展开更多
关键词 Positron emission tomography-computed tomography Polyarteritis nodosa Case report
下载PDF
Evaluation of response to gemcitabine plus cisplatin-based chemotherapy using positron emission computed tomography for metastatic bladder cancer
9
作者 HakanÖztürk İnançKarapolat 《World Journal of Clinical Cases》 SCIE 2023年第36期8447-8457,共11页
BACKGROUND The purpose of the present study was to examine retrospectively the contribution of 18Fluorodeoxyglucose positron emission tomography computed tomography(18FDG-PET/CT)to the evaluation of response to first-... BACKGROUND The purpose of the present study was to examine retrospectively the contribution of 18Fluorodeoxyglucose positron emission tomography computed tomography(18FDG-PET/CT)to the evaluation of response to first-line gemcitabine plus cispla-tin-based chemotherapy in patients with metastatic bladder cancer.AIM To evaluate the response to Gemcitabine plus Cisplatin-based chemotherapy using 18FDG-PET/CT imaging in patients with metastatic bladder cancer.METHODS Between July 2007 and April 2019,79 patients underwent 18FDG-PET/CT imaging with the diagnosis of Metastatic Bladder Carcinoma(M-BCa).A total of 42 pa-tients(38 male,4 female)were included in the study,and all had been admi-nistered Gemcitabine plus Cisplatin-based chemotherapy.After completion of the therapy,the patients underwent a repeat 18FDG-PET/CT scan and the results were compared with the PET/CT findings before chemotherapy according to European Organisation for the Research and treatment of cancer criteria.Mean age was 66.1 years and standard deviation was 10.7 years(range:41–84 years).RESULTS Of the patients,seven(16.6%)were in complete remission,17(40.5%)were in partial remission,six(14.3%)had a stable disease,and 12(28.6%)had a pro-gressive disease.The overall response rate was 57.1 percent.CONCLUSION 18FDG-PET/CT can be considered as a successful imaging tool in evaluating response to first-line chemotherapy for metastatic bladder cancer.Anatomical and functional data obtained from PET/CT scans may be useful in the planning of secondline and thirdline chemotherapy. 展开更多
关键词 Metastatic bladder cancer Response to chemotheraphy Positron emission tomography computed tomography 18FDG-PET/CT
下载PDF
Rare finding of primary aortoduodenal fistula on single-photon emission computed tomography/computed tomography of gastrointestinal bleeding: A case report
10
作者 Chun-Liang Kuo Ching-Fu Chen +2 位作者 Wen-Ko Su Rong-Hsin Yang Yu-Hong Chang 《World Journal of Clinical Cases》 SCIE 2023年第29期7162-7169,共8页
BACKGROUND Primary aortoduodenal fistula is a rare cause of gastrointestinal(GI)bleeding consisting of abnormal channels between the aorta and GI tract without previous vascular intervention that results in massive in... BACKGROUND Primary aortoduodenal fistula is a rare cause of gastrointestinal(GI)bleeding consisting of abnormal channels between the aorta and GI tract without previous vascular intervention that results in massive intraluminal hemorrhage.CASE SUMMARY A 67-year-old man was hospitalized for coffee ground vomiting,tarry stools,and colic abdominal pain.He was repeatedly admitted for active GI bleeding and hypovolemic shock.Intermittent and spontaneously stopped bleeders were undetectable on multiple GI endoscopy,angiography,computed tomography angiography(CTA),capsule endoscopy,and ^(99)mTc-labeled red blood cell(RBC)scans.The patient received supportive treatment and was discharged without signs of rebleeding.Thereafter,he was re-admitted for bleeder identification.Repeated CTA after a bleed revealed a small aortic aneurysm at the renal level contacting the fourth portion of the duodenum.A ^(99)mTc-labeled RBC singlephoton emission CT(SPECT)/CT scan performed during bleeding symptoms revealed active bleeding at the duodenal level.According to his clinical symptoms(intermittent massive GI bleeding with hypovolemic shock,dizziness,dark red stool,and bloody vomitus)and the abdominal CTA and ^(99)mTc-labeled RBC SPECT/CT results,we suspected a small aneurysm and an aortoduodenal fistula.Subsequent duodenal excision and duodenojejunal anastomosis were performed.A 7-mm saccular aneurysm arising from the anterior wall of the abdominal aorta near the left renal artery was identified.Percutaneous intravascular stenting of the abdominal aorta was performed and his symptoms improved.CONCLUSION Our findings suggest that ^(99)mTc-labeled RBC SPECT/CT scanning can aid the diagnosis of a rare cause of active GI bleeding. 展开更多
关键词 Gastrointestinal active bleeding Computed tomography angiography 99mTc-labeled red blood cell scan Singlephoton emission computed tomography/computed tomography Primary aortoduodenal fistula Case report
下载PDF
Impact of random and scattered coincidences from outside of field of view on positron emission tomography/computed tomography imaging with different reconstruction protocols
11
作者 Mahak Osouli Alamdari Pardis Ghafarian +2 位作者 Arman Rahmim Mehrdad Bakhshayesh‑Karam Mohammad Reza Ay 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期40-52,共13页
Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outsi... Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm. 展开更多
关键词 Positron emission tomography/computed tomography(PET/CT) Random coincidences Scatter coincidences·Time of flight(TOF) Point spread function(PSF) Field of view(FOV) Noise equivalent count rate(NECR) Signal-toNoise ratio(SNR)
下载PDF
Appearance of aseptic vascular grafts after endovascular aortic repair on[(18)F]fluorodeoxyglucose positron emission tomography/computed tomography
12
作者 Paige Bennett Maria Bernadette Tomas +2 位作者 Christopher F Koch Kenneth J Nichols Christopher J Palestro 《World Journal of Radiology》 2023年第8期241-249,共9页
BACKGROUND Diagnosis of prosthetic vascular graft infection with[(18)F]fluorodeoxyglucose positron emission tomography/computed tomography(18F-FDG PET/CT)allows for early detection of functional changes associated wit... BACKGROUND Diagnosis of prosthetic vascular graft infection with[(18)F]fluorodeoxyglucose positron emission tomography/computed tomography(18F-FDG PET/CT)allows for early detection of functional changes associated with infection,based on increased glucose utilization by activated macrophages and granulocytes.Aseptic vascular grafts,like all foreign bodies,can stimulate an inflammatory response,which can present as increased activity on 18F-FDG PET/CT.Consequently,distinguishing aseptic inflammation from graft infection,though important,can be difficult.In the case of endovascular aneurysm repair(EVAR),a minimally invasive procedure involving the transfemoral insertion of an endoprosthetic stent graft,the normal postoperative appearance of these grafts on 18F-FDG PET/CT can vary over time,potentially confounding study interpretation.AIM To investigate the visual,semiquantitative,and temporal characteristics of aseptic vascular grafts in patients status post EVAR.METHODS In this observational retrospective cohort study,patients with history of EVAR who underwent 18F-FDG PET/CT for indications other than infection were identified retrospectively.All patients were asymptomatic for graft infection-no abdominal pain,fever of unknown origin,sepsis,or leukocytosis-at the time of imaging and for≥2 mo after each PET/CT.Imaging studies such as CT for each patient were also reviewed,and any patients with suspected or confirmed vascular graft infection were excluded.One hundred two scans performed on 43 patients(34 males;9 females;age=77±8 years at the time of the final PET/CT)were retrospectively reviewed.All 43 patients had an abdominal aortic(AA)vascular graft,40 patients had a right iliac(RI)limb graft,and 41 patients had a left iliac(LI)limb graft.Twentytwo patients had 1 PET/CT and 21 patients had from 2 to 9 PET/CTs.Grafts were imaged between 2 mo to 168 mo(about 14 years)post placement.Eight grafts were imaged within 6 mo of placement,including three that were imaged within three months of placement.The mean interval between graft placement and PET/CT for all 102 scans was 51±39 mo.PET/CT data was reconstructed with region-of-interest analysis of proximal,mid and distal portions of the grafts and background ascending aorta.Maximum standardized uptake value(SUVmax)was recorded for each region.SUVmax-to-background uptake ratios(URs)were calculated.Visual assessment was performed using a 2-pattern grading scale:Diffuse(homogeneous uptake less than liver uptake)and focal(one or more areas of focal uptake in any part of the graft).Statistical analysis was performed.RESULTS In total,there were 306 AA grafts,285 LI grafts,282 RI grafts,and 306 ascending aorta background SUVmax measurements.For all 102 scans,mean SUVmax values for AA grafts were 2.8-3.0 along proximal,mid,and distal segments.Mean SUVmax values for LI grafts and RI grafts were 2.7-2.8.Mean SUVmax values for background were 2.5±0.5.Mean URs were 1.1-1.2.Visual analysis of the scans reflected results of quantitative analysis.On visual inspection,98%revealed diffuse,homogeneous 18F-FDG uptake less than liver.Graft URs and visual pattern categories were significantly associated for AA graft URs(F-ratio=21.5,P<0.001),LI graft URs(F-ratio=20.4,P<0.001),and RI graft URs(F-ratio=30.4,P<0.001).Thus,visual patterns of 18F-FDG uptake corresponded statistically significantly to semiquantitative URs.The age of grafts showing focal patterns was greater than grafts showing diffuse patterns,87±89 vs 50±37 mo,respectively(P=0.02).URs were significantly associated with graft age for AA grafts(r=0.19,P=0.001).URs were also significantly associated with graft age for LI grafts(r=0.25,P<0.0001),and RI grafts(r=0.31,P<0.001).Quartiles of similar numbers of graft(n=25-27)grouped by graft age indicated that URs were significantly higher for 4th quartile vs 2nd quartile URs(F-ratio=19.5,P<0.001).When evaluating URs,graft SUVmax values within 10%-20%of the ascending aorta SUVmax is evident in aseptic grafts,except for grafts in the oldest quartiles.In this study,grafts in the oldest quartiles(>7 years post EVAR)showed SUVmax up to 30%higher than the ascending aorta SUVmax.CONCLUSION Characteristics of an aseptic vascular stent graft in the aorta and iliac vessels on 18F-FDG PET/CT include graft SUVmax values within 10%-20%of the ascending aorta background SUVmax.The SUVmax of older aseptic grafts can be as much as 30%above background.The visual uptake pattern of diffuse,homogeneous uptake less than liver was seen in 98%of aseptic vascular grafts,making this pattern particularly reassuring for clinicians. 展开更多
关键词 Aseptic vascular grafts Endovascular aortic repair [(18)F]fluorodeoxyglucose positron emission tomography/computed tomography
下载PDF
IN VIVO VALIDATION OF DUAL-MODALITY SYSTEM FOR SIMULTANEOUS POSITRON EMISSION TOMOGRAPHY AND OPTICAL TOMOGRAPHIC IMAGING
13
作者 XIN WANG BIN ZHANG +4 位作者 XU CAO FEI LIU SHUANGQUAN LIU BAOCI SHAN JING BAI 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2011年第2期165-171,共7页
We report on tests of combined positron emission tomography(PET)andfluorescence molecular tomography(FMT)imaging system for in vivo investigation on small animals.A nude mouse was inoculated with MD-MB-231 breast canc... We report on tests of combined positron emission tomography(PET)andfluorescence molecular tomography(FMT)imaging system for in vivo investigation on small animals.A nude mouse was inoculated with MD-MB-231 breast cancer cells which expressed redfluorescent protein(RFP).For FMT system,reflective illumination mode was adopted with full-angle data acquisition.[18F]-Fluorodeoxyglucose([18F]-FDG)was used as radioactive tracer for PET.Both data were acquired simultaneously and then reconstructed separately before fusion.Fluorescent tomography results showed exactly where the tumor was located while PET results offered more metabolic information.Results confirmed feasibility for tumor detection and showed superiority to single modality imaging. 展开更多
关键词 Dual-modality imaging positron emission tomography fluorescence molecular tomography
下载PDF
Diagnosis and evaluation of gastric cancer by positron emission tomography 被引量:21
14
作者 Chen-Xi Wu Zhao-Hui Zhu 《World Journal of Gastroenterology》 SCIE CAS 2014年第16期4574-4585,共12页
Gastric cancer is the second leading cause of cancer mortality worldwide. The diagnosis of gastric cancer has been significantly improved with the broad availability of gastrointestinal endoscopy. Effective technologi... Gastric cancer is the second leading cause of cancer mortality worldwide. The diagnosis of gastric cancer has been significantly improved with the broad availability of gastrointestinal endoscopy. Effective technologies for accurate staging and quantitative evaluation are still in demand to merit reasonable treatment and better prognosis for the patients presented with advanced disease. Preoperative staging using conventional imaging tools, such as computed tomography (CT) and endoscopic ultrasonography, is inadequate. Positron emission tomography (PET), using <sup>18</sup>F-fluorodeoxyglucose (FDG) as a tracer and integrating CT for anatomic localization, holds a promise to detect unsuspected metastasis and has been extensively used in a variety of malignancies. However, the value of FDG PET/CT in diagnosis and evaluation of gastric cancer is still controversial. This article reviews the current literature in diagnosis, staging, response evaluation, and relapse monitoring of gastric cancer, and discusses the current understanding, improvement, and future prospects in this area. 展开更多
关键词 Gastric cancer Positron emission tomography/computed tomography 18F-fluorodeoxyglucose
下载PDF
Positron-emission tomography for hepatocellular carcinoma:Current status and future prospects 被引量:7
15
作者 Ren-Cai Lu Bo She +4 位作者 Wen-Tao Gao Yun-Hai Ji Dong-Dong Xu Quan-Shi Wang Shao-Bo Wang 《World Journal of Gastroenterology》 SCIE CAS 2019年第32期4682-4695,共14页
Hepatocellular carcinoma(HCC)is one of the leading causes of cancer mortality worldwide.Various imaging modalities provide important information about HCC for its clinical management.Since positron-emission tomography... Hepatocellular carcinoma(HCC)is one of the leading causes of cancer mortality worldwide.Various imaging modalities provide important information about HCC for its clinical management.Since positron-emission tomography(PET)or PET-computed tomography was introduced to the oncologic setting,it has played crucial roles in detecting,distinguishing,accurately staging,and evaluating local,residual,and recurrent HCC.PET imaging visualizes tissue metabolic information that is closely associated with treatment.Dynamic PET imaging and dual-tracer have emerged as complementary techniques that aid in various aspects of HCC diagnosis.The advent of new radiotracers and the development of immuno-PET and PET-magnetic resonance imaging have improved the ability to detect lesions and have made great progress in treatment surveillance.The current PET diagnostic capabilities for HCC and the supplementary techniques are reviewed herein. 展开更多
关键词 HEPATOCELLULAR CARCINOMA Positron-emission tomography Radiotracer Immuno-positron emission tomography
下载PDF
Diagnostic accuracy of fluorine-18-fluorodeoxyglucose positron emission tomography in gallbladder cancer: A meta-analysis 被引量:8
16
作者 Salvatore Annunziata Daniele Antonio Pizzuto +3 位作者 Carmelo Caldarella Federica Galiandro Ramin Sadeghi Giorgio Treglia 《World Journal of Gastroenterology》 SCIE CAS 2015年第40期11481-11488,共8页
AIM: To meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose(18F-FDG) positron emission tomography(PET) and PET/computed tomography(PET/CT) in the evaluation of primary tumor in ... AIM: To meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose(18F-FDG) positron emission tomography(PET) and PET/computed tomography(PET/CT) in the evaluation of primary tumor in patients with gallbladder cancer(GBCa).METHODS: A comprehensive literature search of studies published through 30 th June 2014 regarding the role of 18F-FDG PET and PET/CT in the evaluation of primary gallbladder cancer(GBCa) was performed. All retrieved studies were reviewed. Pooled sensitivity and specificity of 18F-FDG PET or PET/CT in the evaluation of primary GBCa were calculated. The area under the summary receiving operator characteristics curve(AUC) was calculated to measure the accuracy of these methods. Sub-analyses considering the device used(PET vs PET/CT) were carried out.RESULTS: Twenty-one studies comprising 495 patients who underwent 18F-FDG PET or PET/CT for suspicious GBCa were selected for the systematic review. The meta-analysis of 13 selected studies provided the following results: sensitivity 87%(95%CI: 82%-92%),specificity 78%(95%CI: 68%-86%). The AUC was 0.88. Improvement of sensitivity and specificity was observed when PET/CT was used.CONCLUSION: 18F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of primary tumor in GBCa patients,nevertheless possible sources of false-negative and false-positive results should be kept in mind. PET/CT seems to have a better diagnostic accuracy than PET alone in this setting. 展开更多
关键词 POSITRON emission tomography POSITRON emission TOM
下载PDF
Pitfalls in Positron Emission Tomography/Computed Tomography Imaging:Causes and Their Classifications 被引量:2
17
作者 Tian-ran Li Jia-he Tian +2 位作者 Hui Wang Zi-qian Chen Chun-lei Zhao 《Chinese Medical Sciences Journal》 CAS CSCD 2009年第1期12-19,共8页
Objective To describe the pitfalls in positron emission tomography/computed tomography (PET/CT) imaging and classify them according to the principles of their generation. Methods We summarized retrospectively the ^... Objective To describe the pitfalls in positron emission tomography/computed tomography (PET/CT) imaging and classify them according to the principles of their generation. Methods We summarized retrospectively the ^18F-fluorodeoxyglucose (FDP) PET/CT imaging pitfalls through reviewing the PET/CT images of 872 patients. The pitfalls were divided into artifacts and infrequent physiological uptake, and the artifacts were further classified according to their causes. Meanwhile, we calculated the incidences of various pitfalls. Whether the PET/CT pitfalls influenced the diagnostic decision was analyzed. The appearances of pitfalls in PET were also described. Results Pitfalls could be found in PET/CT images of 684(78.4%) patients. Artifacts were found in 664 (76.15%) patients, and could be classified into self-factor artifacts and equipment-or technology-related artifacts. Among self-factor artifacts, respiratory motion (57.5%), postprandial or hyperglycemia artifacts (2.41%), and metal or high density matter artifacts (1.38%) were frequent. As for equipment-or tectmology-related factors, injection point outleakage or radiotracer contamination (13.88%) and truncation artifacts (1.83%) were most common ones. Infrequent physiological FDG uptakes, including fatty up-take, endometrial uptake, and bilateral breast feeding period uptake, were found in 20 (2.29%) patients. Among all pitfalls, the artifacts in 92 (13.4%) patients and infrequent physiological uptakes in 6 (0.88%) patients affected the diagnostic results. Artifact images in PET could be described as hot or cold area and the images of infrequent physiological uptake were always shown as hot area. Conclusions The incidence of pitfall in PET/CT imaging was high and the causes of pitfalls are various. Among all causes that artifacts generated, respiratory motion is the most common. Some pitfalls may disturb clinical physicians' decision, so it is important to recognize artifacts and physiological uptake, and distinguish them from pathological uptakes. 展开更多
关键词 ^18 F-fluorodeoxyglucose positron emission tomography / computedtomography PITFALL ARTIFACT attenuation correction
下载PDF
Emerging role of ^(18)F-fluorodeoxyglucose positron emission tomography for guiding management of hepatocellular carcinoma 被引量:8
18
作者 Sang Mi Lee Hong Soo Kim +1 位作者 Sangheun Lee Jeong Won Lee 《World Journal of Gastroenterology》 SCIE CAS 2019年第11期1289-1306,共18页
Hepatocellular carcinoma(HCC) is one of major causes of cancer mortality worldwide. For decades, ^(18)F-fluorodeoxyglucose(FDG) positron emission tomography(PET) has been widely used for staging, predicting prognosis,... Hepatocellular carcinoma(HCC) is one of major causes of cancer mortality worldwide. For decades, ^(18)F-fluorodeoxyglucose(FDG) positron emission tomography(PET) has been widely used for staging, predicting prognosis, and detecting cancer recurrence in various types of malignant diseases. Due to low sensitivity of FDG PET for detecting intrahepatic HCC lesions, the clinical value of FDG PET in HCC patients has been limited. However, recent studies with diverse analytic methods have shown that FDG PET has promising role in aiding management of HCC patients. In this review, we will discuss the clinical role of FDG PET for staging, predicting prognosis, and evaluating treatment response in HCC. Further, we will focus on recent clinical studies regarding implication of volumetric FDG PET parameters, the significance of FDG uptake in HCC for selecting treatment and predicting treatment response, and the use of radiomics of FDG PET in HCC. 展开更多
关键词 HEPATOCELLULAR carcinoma FLUORODEOXYGLUCOSE F18 POSITRON emission tomography STAGING Prognosis
下载PDF
^(18)F-Fluorodeoxyglucose positron emission tomography/computed tomography comparison of gastric lymphoma and gastric carcinoma 被引量:5
19
作者 Xiao-Feng Li Qiang Fu +5 位作者 You-Wen Dong Jian-Jing Liu Xiu-Yu Song Dong Dai Cong Zuo Wen-Gui Xu 《World Journal of Gastroenterology》 SCIE CAS 2016年第34期7787-7796,共10页
AIM To compare ^(18)F-fluorodeoxyglucose positron emission tomography/computed tomography(^(18)F-FDG PET/CT) features in gastric lymphoma and gastric carcinoma.METHODS Patients with newly diagnosed gastric lymphoma or... AIM To compare ^(18)F-fluorodeoxyglucose positron emission tomography/computed tomography(^(18)F-FDG PET/CT) features in gastric lymphoma and gastric carcinoma.METHODS Patients with newly diagnosed gastric lymphoma or gastric carcinoma who underwent ^(18)F-FDG PET/CT prior to treatment were included in this study. We reviewed and analyzed the PET/CT features of gastric wall lesions,including FDG avidity,pattern(focal/diffuse),and intensity [maximal standard uptake value:(SUVmax)]. The correlation of SUVmax with gastricclinicopathological variables was investigated by χ~2 test,and receiver-operating characteristic(ROC) curve analysis was performed to determine the differential diagnostic value of SUVmax-associated parameters in gastric lymphoma and gastric carcinoma. RESULTS Fifty-two patients with gastric lymphoma and 73 with gastric carcinoma were included in this study. Abnormal gastric FDG accumulation was found in 49 patients(94.23%) with gastric lymphoma and 65 patients(89.04%) with gastric carcinoma. Gastric lymphoma patients predominantly presented with type Ⅰ and type Ⅱ lesions,whereas gastric carcinoma patients mainly had type Ⅲ lesions. The SUVmax(13.39 ± 9.24 vs 8.35 ± 5.80,P < 0.001) and SUVmax/THKmax(maximal thickness)(7.96 ± 4.02 vs 4.88 ± 3.32,P < 0.001) were both higher in patients with gastric lymphoma compared with gastric carcinoma. ROC curve analysis suggested a better performance of SUVmax/THKmax in the evaluation of gastric lesions between gastric lymphoma and gastric carcinoma in comparison with that of SUVmax alone.CONCLUSION PET/CT features differ between gastric lymphoma and carcinoma,which can improve PET/CT evaluation of gastric wall lesions and help differentiate gastric lymphoma from gastric carcinoma. 展开更多
关键词 GASTRIC LYMPHOMAS GASTRIC CARCINOMAS 18F-FLUORODEOXYGLUCOSE positron emission tomography/ computed tomography MAXIMAL standard uptake value MAXIMAL thickness Differential diagnosis
下载PDF
Positron emission tomography/computerized tomography in the evaluation of primary non-Hodgkin's lymphoma of prostate 被引量:4
20
作者 Bo Pan Jian-Kui Han +1 位作者 Shi-Cun Wang Ao Xu 《World Journal of Gastroenterology》 SCIE CAS 2013年第39期6699-6702,共4页
Primary malignant lymphoma of the prostate is exceedingly rare.Here we report a case of a 65-year-old man who presented with increased urinary frequency,urinary urgency,and urinary incontinence for two years.Benign pr... Primary malignant lymphoma of the prostate is exceedingly rare.Here we report a case of a 65-year-old man who presented with increased urinary frequency,urinary urgency,and urinary incontinence for two years.Benign prostatic hypertrophy was suspected at primary impression.Ultrasound revealed a hypoechoic lesion of the prostate.The total serum prostate-specific antigen was within normal range.Positron emission tomography/computerized tomography(PET/CT)showed a hypermetabolic prostatic lesion.Prostate biopsy was consistent with a non-germinal center diffuse large B cell lymphoma.There was complete remission of the prostatic lesion following six cycles of chemotherapy as shown on the second PET/CT imaging.18F-fluoro-deoxy glucose PET/CT is not only a complement to conventional imaging,but also plays a significant role in the diagnosis and evaluation of treatment response of prostatic lymphoma. 展开更多
关键词 Fluoro-Deoxy-Glucose Positron emission tomography/computerized tomography Non-Hodgkin’s LYMPHOMA PROSTATIC LYMPHOMA EVALUATION
下载PDF
上一页 1 2 250 下一页 到第