A Johann-type X-ray spectrometer was successfully developed at the hard X-ray branch(in-vacuum undulator with a 24-mm periodic length)of the energy material beamline(E-line)at the Shanghai Synchrotron Radiation Facili...A Johann-type X-ray spectrometer was successfully developed at the hard X-ray branch(in-vacuum undulator with a 24-mm periodic length)of the energy material beamline(E-line)at the Shanghai Synchrotron Radiation Facility(SSRF).This spectrometer was utilized to implement X-ray emission spectroscopy(XES),high-energy resolution fluorescence-detected X-ray absorption spectroscopy(HERFD-XAS),and resonant inelastic X-ray scattering.Seven spherically bent crystals were positioned on the respective vertical 500-mm-diameter Rowland circles,adopting an area detector to increase the solid angle to 1.75%of 4πsr,facilitating the study of low-concentrate systems under complex reaction conditions.Operated under the atmosphere pressure,the spectrometer covers the energy region from 3.5 to 18 keV,with the Bragg angle ranging from 73°to 86°during vertical scanning.It offers a promised energy resolution of sub-eV(XES)and super-eV(HERFD-XAS).Generally,these comprehensive core-level spectroscopy methods based on hard X-rays at the E-line with an extremely high photon flux can meet the crucial requirements of a green energy strategy.Moreover,they provide substantial support for scientific advances in fundamental research.展开更多
A space-resolved EUV spectrometer for measuring the one-dimensional distribution of impurity line emissions in Large Helical Device (LHD) has been upgraded to measure two- dimensional distributions of impurity line ...A space-resolved EUV spectrometer for measuring the one-dimensional distribution of impurity line emissions in Large Helical Device (LHD) has been upgraded to measure two- dimensional distributions of impurity line emissions with an extension of working wavelength range to 30-650% The two-dimensional measurement is performed by scanning the observation chord horizontally. A rectangular plasma region of 520 × 700 mm2 in vertical and horizontal sizes can be observed during a single horizontal scan. The horizontal scan requires a time duration of 5 s at least. The spatial resolution is 10 mm in the vertical direction when a spatial-resolution slit of 0.2 mm in width is adopted. Although a spatial resolution in the toroidal direction is 75 mm, it is a function of CCD exposure time and horizontal scanning speed. Two-dimensional distribution of EUV line emissions from several impurities has been successfully observed for the first time from steady discharges in LHD. In this paper two-dimensional distributions of He II (303.78A), C V (40.27A), C VI (33.73A) and Fe XX (132.85A) located at different radial positions are presented with simple analysis on the magnetic field structure of LHD.展开更多
Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spur...Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spurted within nanoseconds and accompanied by strong electromagnetic pulses(EMP), so traditional multi-channel detectors are no longer applicable.In this work, we designed a reflective elliptical crystal spectrometer for the diagnosis of laser-PIXE. The device can detect the energy range of 1 keV–11 ke V with a high resolution. A calibration experiment was completed on the electrostatic accelerator of Peking University using samples of Al, Ti, Cu, and ceramic artifacts. The detection efficiency of the elliptical crystal spectrometer was obtained in the order of 10-9.展开更多
应用被动式遥感FTIR,分别对掺入纳米级金属氧化物、掺入同种材料普通金属氧化物及无掺入物的固体推进剂的燃烧火焰温度进行了测量。固体推进剂的主要成分为硝化棉和硝化甘油。掺加物分别为6nm CuO,56nmFe2O3,16nm Ni O粒子及相应的普通...应用被动式遥感FTIR,分别对掺入纳米级金属氧化物、掺入同种材料普通金属氧化物及无掺入物的固体推进剂的燃烧火焰温度进行了测量。固体推进剂的主要成分为硝化棉和硝化甘油。掺加物分别为6nm CuO,56nmFe2O3,16nm Ni O粒子及相应的普通金属氧化物。FTIR仪器分辨率为1cm-1。利用燃烧产物中H2O分子在2.75μm处的基带发射光谱精细结构,根据分子转振光谱测温法,计算出燃烧火焰温度。结果表明,掺有纳米级CuO,Fe2O3和Ni O粒子的固体推进剂的燃烧火焰温度分别为3089,3193和3183K,此温度与掺入同种材料的普通金属氧化物和无掺入物的固体推进剂的燃烧火焰温度无明显差别。展开更多
基金supported by the National Key Research and Development Program of China(Nos.2022YFA1503801,2021YFA1600800)the Photon Science Center for Carbon Neutrality of Chinese Academy of Sciences+2 种基金Shanghai Science and Technology Development Funds(Nos.22YF1454500,23ZR1471400)the CAS Project for Young Scientists in Basic Research(No.YSBR-022)the National Natural Science Foundation of China(No.12305375)。
文摘A Johann-type X-ray spectrometer was successfully developed at the hard X-ray branch(in-vacuum undulator with a 24-mm periodic length)of the energy material beamline(E-line)at the Shanghai Synchrotron Radiation Facility(SSRF).This spectrometer was utilized to implement X-ray emission spectroscopy(XES),high-energy resolution fluorescence-detected X-ray absorption spectroscopy(HERFD-XAS),and resonant inelastic X-ray scattering.Seven spherically bent crystals were positioned on the respective vertical 500-mm-diameter Rowland circles,adopting an area detector to increase the solid angle to 1.75%of 4πsr,facilitating the study of low-concentrate systems under complex reaction conditions.Operated under the atmosphere pressure,the spectrometer covers the energy region from 3.5 to 18 keV,with the Bragg angle ranging from 73°to 86°during vertical scanning.It offers a promised energy resolution of sub-eV(XES)and super-eV(HERFD-XAS).Generally,these comprehensive core-level spectroscopy methods based on hard X-rays at the E-line with an extremely high photon flux can meet the crucial requirements of a green energy strategy.Moreover,they provide substantial support for scientific advances in fundamental research.
基金partially carried out under the LHD project financial support (NIFS12ULPP010)partly supported by the JSPS-NRF-NSFC A3 Foresight Program in the field of Plasma Physics (No. 11261140328)
文摘A space-resolved EUV spectrometer for measuring the one-dimensional distribution of impurity line emissions in Large Helical Device (LHD) has been upgraded to measure two- dimensional distributions of impurity line emissions with an extension of working wavelength range to 30-650% The two-dimensional measurement is performed by scanning the observation chord horizontally. A rectangular plasma region of 520 × 700 mm2 in vertical and horizontal sizes can be observed during a single horizontal scan. The horizontal scan requires a time duration of 5 s at least. The spatial resolution is 10 mm in the vertical direction when a spatial-resolution slit of 0.2 mm in width is adopted. Although a spatial resolution in the toroidal direction is 75 mm, it is a function of CCD exposure time and horizontal scanning speed. Two-dimensional distribution of EUV line emissions from several impurities has been successfully observed for the first time from steady discharges in LHD. In this paper two-dimensional distributions of He II (303.78A), C V (40.27A), C VI (33.73A) and Fe XX (132.85A) located at different radial positions are presented with simple analysis on the magnetic field structure of LHD.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 11975037 and 11921006)the National Grand Instrument Project of China (Grant Nos. 2019YFF01014400 and 2019YFF01014404)。
文摘Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spurted within nanoseconds and accompanied by strong electromagnetic pulses(EMP), so traditional multi-channel detectors are no longer applicable.In this work, we designed a reflective elliptical crystal spectrometer for the diagnosis of laser-PIXE. The device can detect the energy range of 1 keV–11 ke V with a high resolution. A calibration experiment was completed on the electrostatic accelerator of Peking University using samples of Al, Ti, Cu, and ceramic artifacts. The detection efficiency of the elliptical crystal spectrometer was obtained in the order of 10-9.
文摘应用被动式遥感FTIR,分别对掺入纳米级金属氧化物、掺入同种材料普通金属氧化物及无掺入物的固体推进剂的燃烧火焰温度进行了测量。固体推进剂的主要成分为硝化棉和硝化甘油。掺加物分别为6nm CuO,56nmFe2O3,16nm Ni O粒子及相应的普通金属氧化物。FTIR仪器分辨率为1cm-1。利用燃烧产物中H2O分子在2.75μm处的基带发射光谱精细结构,根据分子转振光谱测温法,计算出燃烧火焰温度。结果表明,掺有纳米级CuO,Fe2O3和Ni O粒子的固体推进剂的燃烧火焰温度分别为3089,3193和3183K,此温度与掺入同种材料的普通金属氧化物和无掺入物的固体推进剂的燃烧火焰温度无明显差别。