期刊文献+
共找到67,003篇文章
< 1 2 250 >
每页显示 20 50 100
Energy Saving Cooperative Communication over Fading Channels with Relay Selection and Power Control 被引量:7
1
作者 Wei Yifei Teng Yinglei +2 位作者 Wang Li Song Mei Man Yi 《China Communications》 SCIE CSCD 2012年第6期124-134,共11页
In order to save energy and make more efficient use of wireless channel, this article puts forward an energy saving cooperative relaying scheme which actuates the cooperative transmis- sion only when the feedback from... In order to save energy and make more efficient use of wireless channel, this article puts forward an energy saving cooperative relaying scheme which actuates the cooperative transmis- sion only when the feedback from the destination indicates failure of the direct transmission. The proposed scheme selects the optimal relay and its corresponding transmission power in each time slot based on channel condition and residual ener- gy with the objective of minimizing energy con- sumption and extending network lifetime. In the study, the f'mite-state Markov channel model is used to characterize the correlation structure of channel fading in wireless networks, and the pro- cedure of relay selection and transmission power decision is formulated as a M arkov decision process. Numerical and simulation results show that the proposed scheme consumes less energy and prolongs the network lifetime. 展开更多
关键词 energy saving relay selection POWERcontrol coop erative communication
下载PDF
Analysis of Power Matching on Energy Savings of a Pneumatic Rotary Actuator Servo-Control System 被引量:3
2
作者 Yeming Zhang Hongwei Yue +1 位作者 Ke Li Maolin Cai 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2020年第2期87-99,共13页
When saving energy in a pneumatic system,the problem of energy losses is usually solved by reducing the air supply pressure.The power-matching method is applied to optimize the air-supply pressure of the pneumatic sys... When saving energy in a pneumatic system,the problem of energy losses is usually solved by reducing the air supply pressure.The power-matching method is applied to optimize the air-supply pressure of the pneumatic system,and the energy-saving effect is verified by experiments.First,the experimental platform of a pneumatic rotary actuator servo-control system is built,and the mechanism of the valve-controlled cylinder system is analyzed.Then,the output power characteristics and load characteristics of the system are derived,and their characteristic curves are drawn.The employed air compressor is considered as a constant-pressure source of a quantitative pump,and the power characteristic of the system is matched.The power source characteristic curve should envelope the output characteristic curve and load characteristic curve.The minimum gas supply pressure obtained by power matching represents the optimal gas supply pressure.The comparative experiments under two different gas supply pressure conditions show that the system under the optimal gas supply pressure can greatly reduce energy losses. 展开更多
关键词 Pneumatic rotary actuator energy savings Gas supply pressure Characteristic curve Power matching
下载PDF
Review of the Tuned Mass Damper Inerter(TMDI)in Energy Harvesting and Vibration Control:Designs,Analysis and Applications
3
作者 Xiaofang Kang Qiwen Huang +3 位作者 Zongqin Wu Jianjun Tang Xueqin Jiang Shancheng Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第6期2361-2398,共38页
Tuned mass damper inerter(TMDI)is a device that couples traditional tuned mass dampers(TMD)with an inertial device.The inertial device produces resistance proportional to the relative acceleration at its two ends thro... Tuned mass damper inerter(TMDI)is a device that couples traditional tuned mass dampers(TMD)with an inertial device.The inertial device produces resistance proportional to the relative acceleration at its two ends through its“inertial”constant.Due to its unique mechanical properties,TMDI has received widespread attention and application in the past twenty years.As different configurations are required in different practical situations,TMDI is still active in the research on vibration control and energy harvesting in structures.This paper provides a comprehensive review of the research status of TMDI.This work first examines the generation and important vibration control characteristics of TMDI.Then,the energy harvesting performance of electromagnetic tuned mass damper inerter(EM-TMDI)is discussed.This work emphasizes the formation of a passive dynamic vibration absorber by coupling traditional TMD with inertial devices.This paper also summarizes the design and implementation of optimal vibration control and energy harvesting for TMDI.Furthermore,this paper details the applications of TMDI in the fields of bridges and building engineering.Finally,this paper summarizes the necessity of research on tuned mass-damper-inertia,the challenges faced currently,and future research directions,such as control of parameters in electromagnetic energy harvesting TMDI systems and low-cost TMDI. 展开更多
关键词 TMDI EM-TMDI energy harvesting vibration control inertial device
下载PDF
Intelligent Fractional-Order Controller for SMES Systems in Renewable Energy-Based Microgrid
4
作者 Aadel M.Alatwi Abualkasim Bakeer +3 位作者 Sherif A.Zaid Ibrahem E.Atawi Hani Albalawi Ahmed M.Kassem 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第8期1807-1830,共24页
An autonomous microgrid that runs on renewable energy sources is presented in this article.It has a supercon-ducting magnetic energy storage(SMES)device,wind energy-producing devices,and an energy storage battery.Howe... An autonomous microgrid that runs on renewable energy sources is presented in this article.It has a supercon-ducting magnetic energy storage(SMES)device,wind energy-producing devices,and an energy storage battery.However,because such microgrids are nonlinear and the energy they create varies with time,controlling and managing the energy inside them is a difficult issue.Fractional-order proportional integral(FOPI)controller is recommended for the current research to enhance a standalone microgrid’s energy management and performance.The suggested dedicated control for the SMES comprises two loops:the outer loop,which uses the FOPI to regulate the DC-link voltage,and the inner loop,responsible for regulating the SMES current,is constructed using the intelligent FOPI(iFOPI).The FOPI+iFOPI parameters are best developed using the dandelion optimizer(DO)approach to achieve the optimum performance.The suggested FOPI+iFOPI controller’s performance is contrasted with a conventional PI controller for variations in wind speed and microgrid load.The optimal FOPI+iFOPI controller manages the voltage and frequency of the load.The behavior of the microgrid as a reaction to step changes in load and wind speed was measured using the proposed controller.MATLAB simulations were used to evaluate the recommended system’s performance.The results of the simulations showed that throughout all interruptions,the recommended microgrid provided the load with AC power with a constant amplitude and frequency.In addition,the required load demand was accurately reduced.Furthermore,the microgrid functioned incredibly well despite SMES and varying wind speeds.Results obtained under identical conditions were compared with and without the best FOPI+iFOPI controller.When utilizing the optimal FOPI+iFOPI controller with SMES,it was found that the microgrid performed better than the microgrid without SMES. 展开更多
关键词 Fractional-order proportional integral(FOPI) intelligent controller renewable energy resources superconducting magnetic energy storage OPTIMIZATION
下载PDF
Performance enhancement of a viscoelastic bistable energy harvester using time-delayed feedback control
5
作者 黄美玲 杨勇歌 刘洋 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第6期142-154,共13页
This paper focuses on the stochastic analysis of a viscoelastic bistable energy harvesting system under colored noise and harmonic excitation, and adopts the time-delayed feedback control to improve its harvesting eff... This paper focuses on the stochastic analysis of a viscoelastic bistable energy harvesting system under colored noise and harmonic excitation, and adopts the time-delayed feedback control to improve its harvesting efficiency. Firstly, to obtain the dimensionless governing equation of the system, the original bistable system is approximated as a system without viscoelastic term by using the stochastic averaging method of energy envelope, and then is further decoupled to derive an equivalent system. The credibility of the proposed method is validated by contrasting the consistency between the numerical and the analytical results of the equivalent system under different noise conditions. The influence of system parameters on average output power is analyzed, and the control effect of the time-delayed feedback control on system performance is compared. The output performance of the system is improved with the occurrence of stochastic resonance(SR). Therefore, the signal-to-noise ratio expression for measuring SR is derived, and the dependence of its SR behavior on different parameters is explored. 展开更多
关键词 energy harvesting BISTABILITY stochastic averaging method stochastic resonance time-delayed feedback control
下载PDF
Identification of time-varying system and energy-based optimization of adaptive control in seismically excited structure
6
作者 Elham Aghabarari Fereidoun Amini Pedram Ghaderi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第1期227-240,共14页
The combination of structural health monitoring and vibration control is of great importance to provide components of smart structures.While synthetic algorithms have been proposed,adaptive control that is compatible ... The combination of structural health monitoring and vibration control is of great importance to provide components of smart structures.While synthetic algorithms have been proposed,adaptive control that is compatible with changing conditions still needs to be used,and time-varying systems are required to be simultaneously estimated with the application of adaptive control.In this research,the identification of structural time-varying dynamic characteristics and optimized simple adaptive control are integrated.First,reduced variations of physical parameters are estimated online using the multiple forgetting factor recursive least squares(MFRLS)method.Then,the energy from the structural vibration is simultaneously specified to optimize the control force with the identified parameters to be operational.Optimization is also performed based on the probability density function of the energy under the seismic excitation at any time.Finally,the optimal control force is obtained by the simple adaptive control(SAC)algorithm and energy coefficient.A numerical example and benchmark structure are employed to investigate the efficiency of the proposed approach.The simulation results revealed the effectiveness of the integrated online identification and optimal adaptive control in systems. 展开更多
关键词 integrated online identification time-varying systems structural energy multiple forgetting factor recursive least squares optimal simple adaptive control algorithm
下载PDF
Adaptive linear active disturbance-rejection control strategy reduces the impulse current of compressed air energy storage connected to the grid
7
作者 Jianhui Meng Yaxin Sun Zili Zhang 《Global Energy Interconnection》 EI CSCD 2024年第5期577-589,共13页
The merits of compressed air energy storage(CAES)include large power generation capacity,long service life,and environmental safety.When a CAES plant is switched to the grid-connected mode and participates in grid reg... The merits of compressed air energy storage(CAES)include large power generation capacity,long service life,and environmental safety.When a CAES plant is switched to the grid-connected mode and participates in grid regulation,using the traditional control mode with low accuracy can result in excess grid-connected impulse current and junction voltage.This occurs because the CAES output voltage does not match the frequency,amplitude,and phase of the power grid voltage.Therefore,an adaptive linear active disturbance-rejection control(A-LADRC)strategy was proposed.Based on the LADRC strategy,which is more accurate than the traditional proportional integral controller,the proposed controller is enhanced to allow adaptive adjustment of bandwidth parameters,resulting in improved accuracy and response speed.The problem of large impulse current when CAES is switched to the grid-connected mode is addressed,and the frequency fluctuation is reduced.Finally,the effectiveness of the proposed strategy in reducing the impact of CAES on the grid connection was verified using a hardware-in-the-loop simulation platform.The influence of the k value in the adaptive-adjustment formula on the A-LADRC was analyzed through simulation.The anti-interference performance of the control was verified by increasing and decreasing the load during the presynchronization process. 展开更多
关键词 Compressed air energy storage Linear active disturbance-rejection control Smooth grid connection Impulse current Adaptive adjustment of bandwidth parameters
下载PDF
Multi-Time Scale Optimal Scheduling of a Photovoltaic Energy Storage Building System Based on Model Predictive Control
8
作者 Ximin Cao Xinglong Chen +2 位作者 He Huang Yanchi Zhang Qifan Huang 《Energy Engineering》 EI 2024年第4期1067-1089,共23页
Building emission reduction is an important way to achieve China’s carbon peaking and carbon neutrality goals.Aiming at the problem of low carbon economic operation of a photovoltaic energy storage building system,a ... Building emission reduction is an important way to achieve China’s carbon peaking and carbon neutrality goals.Aiming at the problem of low carbon economic operation of a photovoltaic energy storage building system,a multi-time scale optimal scheduling strategy based on model predictive control(MPC)is proposed under the consideration of load optimization.First,load optimization is achieved by controlling the charging time of electric vehicles as well as adjusting the air conditioning operation temperature,and the photovoltaic energy storage building system model is constructed to propose a day-ahead scheduling strategy with the lowest daily operation cost.Second,considering inter-day to intra-day source-load prediction error,an intraday rolling optimal scheduling strategy based on MPC is proposed that dynamically corrects the day-ahead dispatch results to stabilize system power fluctuations and promote photovoltaic consumption.Finally,taking an office building on a summer work day as an example,the effectiveness of the proposed scheduling strategy is verified.The results of the example show that the strategy reduces the total operating cost of the photovoltaic energy storage building system by 17.11%,improves the carbon emission reduction by 7.99%,and the photovoltaic consumption rate reaches 98.57%,improving the system’s low-carbon and economic performance. 展开更多
关键词 Load optimization model predictive control multi-time scale optimal scheduling photovoltaic consumption photovoltaic energy storage building
下载PDF
An Energy-Saving Control Strategy on Central Air-Conditioning System 被引量:1
9
作者 Sheng Xing 1 , Yin Juan 2 , Shang Jingfu 3 , Yu Yang 4 , Wu Zhangxian 5 1. State Grid Information & Telecommunication Co., Ltd. 2. China Huadian Finance Corporation Limited 3. State Grid AC Engineering Construction Company 4. Northeast China Electric Power Dispatching & Communication Center 5. North China Electric Power University 《Electricity》 2011年第4期62-66,共5页
An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature con... An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature control systems, and then parameters in the cold load model and in the central air-conditioning system model are estimated. Generalized predictive control (GPC) is used to establish an optimization model to minimize the consumption of energy and the control error of temperature. The simulated annealing (SA) algorithm, combined with quadratic programming, is adopted to solve the optimal problem. Contrasted with the simulation of traditional PID control, the results prove the effectiveness of this proposed strategy. 展开更多
关键词 central air-conditioning predictive control energy saving time-delay system simulated annealing
下载PDF
Control performance and energy saving of multi-level pressure switching control system based on independent metering control
10
作者 Cao Xiaoming Yao Jing +1 位作者 Sha Tong Wang Pei 《High Technology Letters》 EI CAS 2020年第2期224-234,共11页
Aiming at the problem of large energy consumption in hydraulic control system with large load and variable working conditions,based on the multi-level pressure switching control system(MPSCS),a multi-level pressure sw... Aiming at the problem of large energy consumption in hydraulic control system with large load and variable working conditions,based on the multi-level pressure switching control system(MPSCS),a multi-level pressure switching control system based on independent metering control is proposed combined with the independent metering control technology.The configuration principle of the system is given,the mathematical model of this system is established,and the control strategy of the system under 4 different working quadrants is put forward.Finally,the control performance and energy saving characteristics of the system are tested.The test results show that the switching of high and low pressure power supply has a certain effect on the response of step position and ramp position under impedance working condition.The displacement curves show slow climbing or abrupt change of ramp position,and the position accuracy is less than 1 mm.The multi-level pressure switching control system based on independent metering control can recover and store energy under the transcendence working conditions.The control accuracy is about 1 mm,and the energy recovery rate is about 70%~80%. 展开更多
关键词 MULTI-LEVEL pressure INDEPENDENT METERING control DISPLACEMENT control energy saving hydraulic switching system
下载PDF
A Stable Energy Saving Adaptive Control Scheme for Building Heating and Cooling Systems
11
作者 Sumera I. Chaudhry Manohar Das 《Journal of Power and Energy Engineering》 2014年第5期14-25,共12页
This paper presents a stable, nonlinear, adaptive control scheme for building heating and cooling systems. The proposed controller utilizes the principle of adaptive one step ahead control and aims at reducing the ene... This paper presents a stable, nonlinear, adaptive control scheme for building heating and cooling systems. The proposed controller utilizes the principle of adaptive one step ahead control and aims at reducing the energy consumed for heating or cooling a building. The design steps are discussed in details and a proof of global stability is also provided. Also, the performance of the proposed controller is demonstrated on a simulated building thermal model. 展开更多
关键词 BUILDING HVAC control ADAPTIVE control energy saving control
下载PDF
Using the Power Control and Cooperative Communication for Energy Saving in Mobile Ad Hoc Networks
12
作者 Chunjie Chen Chao Jin +2 位作者 Demin Li Jiacun Wang Jianan Fang 《Communications and Network》 2010年第1期1-10,共10页
In this paper, we investigate the energy saving problem in mobile ad hoc network, and give out an improved variable-range transmission power control algorithm based on minimum spanning tree algorithm (MST). Using prev... In this paper, we investigate the energy saving problem in mobile ad hoc network, and give out an improved variable-range transmission power control algorithm based on minimum spanning tree algorithm (MST). Using previous work by Gomez and Campbell [1], we show that in consider of node's mobility, the previous variable-range transmission power control based on minimum spanning tree algorithm can not support nodes' mobility in mobile ad hoc network. For this reason, we give out an improved variable-range transmission power control algorithm to support node's mobility and solve asymmetric graph problem. To save more energy without changing the topology of the network, we give out two new data transmission mechanisms based on the idea of cooperative communication. The results of this paper enhance the possibility of using variable-range transmission power control in mobile ad hoc networks. 展开更多
关键词 minimum SPANNING TREE TRAFFIC capacity energy savingS COOPERATIVE communication
下载PDF
Energy Saving for Automatic Train Control in Moving Block Signaling System
13
作者 GU Qing MENG Yu MA Fei 《China Communications》 SCIE CSCD 2014年第A02期12-22,共11页
With rapid development of the railway traffic, the moving block signaling system (MBS) method has become more and more important for increasing the track capacity by allowing trains to run in a shorter time-headway ... With rapid development of the railway traffic, the moving block signaling system (MBS) method has become more and more important for increasing the track capacity by allowing trains to run in a shorter time-headway while maintaining the required safety margins. In this framework, the tracking target point of the following train is moving forward with its leading train. This paper focuses on the energy saving tracking control of two successive trains in MBS. Nonlinear programming method is used to optimize the energy-saving speed trajectory of the following train. The real-time location of the leading train could be integrated into the optimization process. Due to simplicity, it can be used for online implementation. The feasibility and effectiveness are verified through simulation. The results show that the new method is efficient on energy saving even when disturbances present. 展开更多
关键词 moving block signaling (MBS) energy saving automatic train protection (ATP) automatic train operation (ATO) TRACKING train speed trajectory
下载PDF
Research on the cooperative train control method in the metro system for energy saving
14
作者 Siyao Li Bo Yuan +1 位作者 Yun Bai Jianfeng Liu 《Railway Sciences》 2023年第3期371-394,共24页
Purpose–To address the problem that the current train operation mode that train selects one of several offline pre-generated control schemes before the departure and operates following the scheme after the departure,... Purpose–To address the problem that the current train operation mode that train selects one of several offline pre-generated control schemes before the departure and operates following the scheme after the departure,energy-saving performance of the whole metro system cannot be guaranteed.Design/methodology/approach–A cooperative train control framework is formulated to regulate a novel train operation mode.The classic train four-phase control strategy is improved for generating specific energy-efficient control schemes for each train.An improved brute force(BF)algorithm with a two-layer searching idea is designed to solve the optimisation model of energy-efficient train control schemes.Findings–Case studies on the actual metro line in Guangzhou,China verify the effectiveness of the proposed train control methods compared with four-phase control strategy under different kinds of train operation scenarios and calculation parameters.The verification on the computation efficiency as well as accuracy of the proposed algorithm indicates that it meets the requirement of online optimisation.Originality/value–Most existing studies optimised energy-efficient train timetable or train control strategies through an offline process,which has a defect in coping with the disturbance or delays effectively and promptly during real-time train operation.This paper studies an online optimisation of cooperative train control based on the rolling optimisation idea,where energy-efficient train operation can be realised once train running time is determined,thus mitigating the impact of unpredictable operation situations on the energy-saving performance of trains. 展开更多
关键词 Train operation scheme energy saving Cooperative control Metro system
下载PDF
Design of Weigh Feeder Control System for Energy Saving Using Performance-Adaptive Method
15
作者 Takao Sato Shohei Kitano +2 位作者 Toru Yamamoto Nozomu Araki Yasuo Konishi 《Journal of Mechanics Engineering and Automation》 2012年第1期1-8,共8页
This paper discusses a design method for the control system of a weigh feeder that supplies powder and granular material at a constant rate. Most weigh feeders employed in industry are controlled by proportional and i... This paper discusses a design method for the control system of a weigh feeder that supplies powder and granular material at a constant rate. Most weigh feeders employed in industry are controlled by proportional and integral (PI) compensation, and the control performance is decided by the selection of parameters. To attain advanced control performance by PI control, the PI parameters are designed on the basis of generalized minimum variance control (GMVC). In this study, to achieve user-specified control performance by GMVC-based PI control, the design parameters of GMVC are automatically adjusted using a performance-adaptive method. The control performance discussed in this study consists of the variance of the control error and that of the difference in the control input. In a conventional performance-adaptive method, the variance of the control error is reduced. In this study, to reduce energy consumption and to achieve user-specified control performance, the variance of the difference in the control input is specified and the design parameter is determined. To demonstrate its effectiveness, the proposed method is applied to an actual weigh feeder. 展开更多
关键词 Weigh feeder performance-adaptive PI (proportional and integral) control generalized minimum variance control energy saving.
下载PDF
Research of Energy-saving Control of Oil-well Power Heater Based on RNN Neural Network
16
作者 SUN Jingen YANG Yang 《沈阳理工大学学报》 CAS 2014年第4期87-94,共8页
For the beam pumping unit,the power consumption of oil-well power heater accounts for a large part of the pumping unit.Decreasing the energy consumption of the power heater is an important approach to reduce that of t... For the beam pumping unit,the power consumption of oil-well power heater accounts for a large part of the pumping unit.Decreasing the energy consumption of the power heater is an important approach to reduce that of the pumping unit.To decrease the energy consumption of oil-well power heater,the proper control method is needed.Based on summarizing the existing control method of power heater,a control method of oil-well power heater of beam pumping unit based on RNN neural network is proposed.The method is forecasting the polished rod load of the beam pumping unit through RNN neural network and using the polished rod load for real-time closed-loop control of the power heater,which adjusts average output power,so as to decrease the power consumption.The experimental data show that the control method is entirely feasible.It not only ensures the oil production,but also improves the energy-saving effect of the pumping unit. 展开更多
关键词 RNN neural network oil-wells power heating energy-saving
下载PDF
Application of the intelligent parameter control energy-saving technology in pumping unit of cluster well
17
《石油石化节能》 2012年第11期57-58,共2页
关键词 《石油石化节能》 英文摘要 期刊 编辑工作 23
下载PDF
Strategies for Introducing Energy Saving Idea into Residential Planning and Design in Urban and Rural Areas of China 被引量:4
18
作者 卢玫珺 郝丽君 《Journal of Landscape Research》 2012年第5期35-36,共2页
Currently,energy saving design has been conducted on single building but not on the whole residential community in urban and rural areas.So,the paper has proposed energy saving measures for residential planning from t... Currently,energy saving design has been conducted on single building but not on the whole residential community in urban and rural areas.So,the paper has proposed energy saving measures for residential planning from the perspective of site selection and layout of buildings.Specific measures are as follows.Firstly,buildings should be constructed on the sunny side and leeside;secondly,buildings on the south should be lower than those on the north;the east side of the building should be open while the west side should be closed;thirdly,climate protection unit should be set;fourthly,buildings should be of northsouth direction primarily,and the main room should be set on the east side and the assistant rooms or passage on the west side in the buildings of east-west direction;fifthly,it should select compact and wellarranged households and the units should not be combined in point and dislocation and jointing. 展开更多
关键词 RESIDENTIAL area PLANNING and DESIGN PLANNING SOURCE Integrated DESIGN energy saving IDEA
下载PDF
Optimal control of wireless energy transfer system via decreasing frequency 被引量:2
19
作者 谭林林 黄学良 +1 位作者 周亚龙 赵俊峰 《Journal of Southeast University(English Edition)》 EI CAS 2013年第3期259-263,共5页
In order to solve the multiple power extreme value point problem caused by system frequency splitting during wireless energy transmission at short distances a transmission model of the system is established.With the c... In order to solve the multiple power extreme value point problem caused by system frequency splitting during wireless energy transmission at short distances a transmission model of the system is established.With the comprehensive consideration of the resonance frequency load parameters and the coupling between coils the internal factors of frequency splitting and boundary conditions are discussed.The results show that under the condition of the fixed load the higher the natural resonance frequency the easier the frequency splitting. As the frequency splitting occurs the frequency of the maximum power transfer is no longer with the natural resonance frequency which can make the system unstable and the transfer power more difficult to control. Therefore a decreasing-frequency method is proposed to avoid the system frequency splitting. And decreasing the system resonance frequency can make the system successfully withdraw the frequency splitting area at a short-distance range.Under the fixed load condition the transmission power of the system can be increased by 400% and the transmission efficiency is reduced by only 14% which greatly improves the transmission performance of the system. 展开更多
关键词 optimal control wireless energy transfer decreasing frequency
下载PDF
Experimental study and energy saving analysis of a novel radiant ceiling heating system 被引量:1
20
作者 汪峰 梁彩华 张小松 《Journal of Southeast University(English Edition)》 EI CAS 2015年第1期118-123,共6页
In order to have an in-depth understanding of the metal ceiling radiant panel with capillary tubes, a radiant ceiling heating system is constructed to study the actual heating performance and thermal comfort by experi... In order to have an in-depth understanding of the metal ceiling radiant panel with capillary tubes, a radiant ceiling heating system is constructed to study the actual heating performance and thermal comfort by experiments. In addition, the energy saving potential of the novel heating system is discussed in terms of the COP (coefficient of performance) of the ground source heat pump and the exergy efficiency of the radiant terminal. The results indicate that the heating system shows high thermal stability and thermal comfort. When the system reaches a stable condition, the radiant heat transfer accounts for 62.7% of the total heat transfer, and the total heat transfer can meet the heating demands of most buildings. Compared to a radiant floor heating system, it offers advantages in a shorter preheating time, a lower supply water temperature and a stronger heating capability. The COP of the ground source heat pump is increased greatly when the supply water temperature is 28 to 33 ℃, and the exergy efficiency of the metal ceiling with capillary tubes is 1.6 times that of the radiant floor when the reference temperature is 5 ℃ The novel radiant ceiling heating system shows a tremendous energy saving potential. 展开更多
关键词 radiant heating system capillary tube heatingperformance energy saving exergy efficiency
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部