A PVC membrane enoxacin ion-selective electrode based on a needle-shaped inner reference electrode was prepared. A Ag/AgCl wire was used as the substrate of this electrode. It was previously coated with a thin sheet o...A PVC membrane enoxacin ion-selective electrode based on a needle-shaped inner reference electrode was prepared. A Ag/AgCl wire was used as the substrate of this electrode. It was previously coated with a thin sheet of urea-formaldehyde resin containing Cl - ions to form a needle-shaped inner reference electrode, then the inner reference electrode was coated with a thin sheet of a PVC membrane containing an enoxacin tetraphenylborate ion-pair complex. The influences of various ion-pair complexes, concentrations of the active components in the membrane and the plasticizers on the performance of the electrode were studied by orthogonal design. The linear response range of the electrode was 7.9×10 -5 -1.0×10 -2 mol/L. The detection limit was 2.0×10 -5 mol/L. The slope was 30.4 mV/decade(25 ℃). The electrode can be used for the potentiometric determination of enoxacin tablets directly. The average recovery was 100.4%, and the RSD was 0.9%. The results agreed with those determined by the method in Chinese Pharmacopoeia.展开更多
A new ion-selective pH electrode of PVC membrane used formeasuring pH of the upper digestive tract is reported in this paper, which wasprepared with tri-n-octylamine or tris-(2-ehtylhexy)amine sensitive materials,and ...A new ion-selective pH electrode of PVC membrane used formeasuring pH of the upper digestive tract is reported in this paper, which wasprepared with tri-n-octylamine or tris-(2-ehtylhexy)amine sensitive materials,and polyvinylchloride (PVC) as a base. It was shown that the electrode has widelinearity (0.5-8, 3-12), good reproducibility, proper responsible time (【30s),longer life span (15 days). And the measurement was carried out in 50 cases bythe electrode.展开更多
A calcium ion-setective eletrode based on a new neutral carrier was studied.The electrode gives a Nernstian response in the rang 5.9-1 Pa and the response is stable in a wide pH range.Logarithms of setectivity coeffic...A calcium ion-setective eletrode based on a new neutral carrier was studied.The electrode gives a Nernstian response in the rang 5.9-1 Pa and the response is stable in a wide pH range.Logarithms of setectivity coefficents are -2.3 Li(+),-3.5 Na(+),-4.0 K(+),-3.7NH_4(+),-4.5 Mg(2+) and -4.4Zn(2+).展开更多
The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulf...The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulfonate)(PEDOT(PSS))was characterized by a developed coulometric signal transduction method.PEDOT(PSS)solid contact is covered by PVC based H+-selective membrane.The obtained coulometric signal demonstrates that the cumulated charge can be amplified by increasing the capacitance of solid contact.SCISEs covered with spin-coated membrane behave faster amperometric response than electrodes with drop-cast mem-brane.In contrast to earlier works,the amperometric response and impedance spectrum demonstrates H+transfer through SCISEs is independent from the thickness of membrane.The exceptional behavior of PANI(Cl)H+-SCISEs shows that the capacitance estimated from impedance spectrum at low frequency 10 mHz and coulometric signal of PANI(Cl)based SCISEs is influenced by the applied po-tentials,whereas PEDOT(PSS)solid contact is independent from the chosen applied potentials.Furthermore,preliminary investiga-tions of coulometric signal transduction on flexible pH sensor implies its potential applications in wearable sensors for sweat ion concentration detection.展开更多
Three new 'tailed' porphyrins and their corresponding Mn(Ⅲ) metalloporphyrins were synthesized and characterized. The potentiometric response characteristics of the PVC membrane electrode based on the Mn(Ⅲ...Three new 'tailed' porphyrins and their corresponding Mn(Ⅲ) metalloporphyrins were synthesized and characterized. The potentiometric response characteristics of the PVC membrane electrode based on the Mn(Ⅲ) complexes of the three new 'tailed' porphyrins toward SCN- have been studied.展开更多
PVC (a poly vinyl chloride) membrane was prepared by using phenyl disulfide as a carrier for selective determination of Pd (II) ion. The membrane can be worked well over a wide concentration range (1.0 × 106...PVC (a poly vinyl chloride) membrane was prepared by using phenyl disulfide as a carrier for selective determination of Pd (II) ion. The membrane can be worked well over a wide concentration range (1.0 × 106-1.0 × 10-1) M with a slope 29.53 mV/decade and a limit of detection (1.77× 10-7) M. The measured of response time was 9 s. It was found to be selective and useable within the pH range (3.0-7.0). The lifetime of membrane sensor prepared could be used for at least 4 months. The electrode was successfully used as an indicator electrode in potentiometric titration of palladium ion with EDTA.展开更多
The construction and performance characteristics of a novel Iron(III) membrane sensor based on (37-bis-[(diethoxy-thiophosphoryl)-oxy]-5,11,17,23,29,35-hexa-kis-(1,1-dimethylethyl)-calix[6]-arene-38,39,40,41,42-pentol...The construction and performance characteristics of a novel Iron(III) membrane sensor based on (37-bis-[(diethoxy-thiophosphoryl)-oxy]-5,11,17,23,29,35-hexa-kis-(1,1-dimethylethyl)-calix[6]-arene-38,39,40,41,42-pentol) (A) were reported in this paper. The sensor was prepared by incorporating compound (A) into a plasticized polyvinyl chloride PVC membrane. The electrode reveals a Nernstian behavior over a wide iron ion concentration range (1.0 × 10-2 - 1.0 × 10-4 mol·L-1), and relatively low detection limit (1.0 × 10-5 mol·L-1). The potentiometric response was independent on the pH of the solution in the range of 4 - 7. The electrode showed a very short response time (<5 s). It exhibited very good selectivity relative to a wide variety of metal cations. Correlation of selectivity coefficient values with ionic radii of interferent cations was discussed. The proposed iron- ISE was applied for analysis of iron containing samples with comparison to a recommended spectrophotometric method.展开更多
A novel Ce(Ⅳ) ion-selective polyvinyl chloride(PVC) membrane electrode based on HDEHP and HEH/EHP as ionophore was successfully prepared. The factors affecting the response of Ce(Ⅳ) ion were investigated, such...A novel Ce(Ⅳ) ion-selective polyvinyl chloride(PVC) membrane electrode based on HDEHP and HEH/EHP as ionophore was successfully prepared. The factors affecting the response of Ce(Ⅳ) ion were investigated, such as membrane composition, internal solution, concentration of SO_4^(2–), and acidity in test solution. The best performance was obtained using the membrane with PVC:DBP:HDEHP:HEH/EHP:OA mass ratio of 75:175:5:5:5. The proposed electrode exhibited a Nernstian slope of 30.44 mV/decade for Ce(Ⅳ) ion over a linear concentration range of 1×10^(–5)–1×10^(–1) mol/L with the detection limit of 9.0×10^(-6) mol/L. The electrode showed stable response within the SO_4^(2–) concentration range of 0.1–1 mol/L and the acidity range of 0.25–1.2 mol/L H+. The proposed electrode showed high selectivity for Ce(Ⅳ) over a wide variety of interfering ions and a fast response time. It was used as an indicator in the potentiometric titration of Ce(Ⅳ) solution with H_2O_2 solution, and could also be used for the determination of Ce(Ⅳ) in real Ce(Ⅳ)-containing aqueous samples.展开更多
The construction,performance characteristics and application of a new bismuth(Ⅲ) PVC membrane electrode based on 5-(3,4,5-trimethoxyphenyl)-4-amino-1,2,4-triazole-3-thiol are reported in this paper.The designed s...The construction,performance characteristics and application of a new bismuth(Ⅲ) PVC membrane electrode based on 5-(3,4,5-trimethoxyphenyl)-4-amino-1,2,4-triazole-3-thiol are reported in this paper.The designed sensor exhibited a Nernstian response for Bi^3+ ion ranging from 5.0×10^-7 mol/L to1.0×10^-2 mol/L with a slope of 19.8 mV/decade.The operational pH range of the sensor is 3.0-6.0.The electrode shows a response time of 6 s and can be used for at least five weeks without any considerable divergence in potentials.It exhibits very good selectivity relative to a wide variety of alkali,alkaline earth,transition and heavy metal ions.The proposed electrode could be used as an indicator electrode in potentiometric titration of Bi^3+ ions with EDTA and in the determination of Bi^3+ content in stomach medicine.展开更多
The zwitterionic compound,levofloxacin,was determined for the first time at different pH values in pure samples,pharmaceutical preparations and spiked serum and urine samples.Different types of potentiometric sensors ...The zwitterionic compound,levofloxacin,was determined for the first time at different pH values in pure samples,pharmaceutical preparations and spiked serum and urine samples.Different types of potentiometric sensors including poly(vinyl chloride)membrane electrode,carbon paste electrode and screen printed electrode,containing the ion pair levofloxaciniumphosphomolybdate as the electroactaive species,were used for this purpose.The effect of pH is the key factor in determining the ratio of the different species that can exist in the medium(zwitterionic,monocationic,dicationic,anionic and neutral),and so it is the controller of the electrochemical performance.The different sensors were fully characterized and optimized in terms of composition,pH effect,selectivity,response and lifetimes.The different sensors showed reliable reversibility and could be utilized for the determination of the drug in real spiked physiological fluids with reliable recovery values.展开更多
文摘A PVC membrane enoxacin ion-selective electrode based on a needle-shaped inner reference electrode was prepared. A Ag/AgCl wire was used as the substrate of this electrode. It was previously coated with a thin sheet of urea-formaldehyde resin containing Cl - ions to form a needle-shaped inner reference electrode, then the inner reference electrode was coated with a thin sheet of a PVC membrane containing an enoxacin tetraphenylborate ion-pair complex. The influences of various ion-pair complexes, concentrations of the active components in the membrane and the plasticizers on the performance of the electrode were studied by orthogonal design. The linear response range of the electrode was 7.9×10 -5 -1.0×10 -2 mol/L. The detection limit was 2.0×10 -5 mol/L. The slope was 30.4 mV/decade(25 ℃). The electrode can be used for the potentiometric determination of enoxacin tablets directly. The average recovery was 100.4%, and the RSD was 0.9%. The results agreed with those determined by the method in Chinese Pharmacopoeia.
文摘A new ion-selective pH electrode of PVC membrane used formeasuring pH of the upper digestive tract is reported in this paper, which wasprepared with tri-n-octylamine or tris-(2-ehtylhexy)amine sensitive materials,and polyvinylchloride (PVC) as a base. It was shown that the electrode has widelinearity (0.5-8, 3-12), good reproducibility, proper responsible time (【30s),longer life span (15 days). And the measurement was carried out in 50 cases bythe electrode.
文摘A calcium ion-setective eletrode based on a new neutral carrier was studied.The electrode gives a Nernstian response in the rang 5.9-1 Pa and the response is stable in a wide pH range.Logarithms of setectivity coefficents are -2.3 Li(+),-3.5 Na(+),-4.0 K(+),-3.7NH_4(+),-4.5 Mg(2+) and -4.4Zn(2+).
基金We are grateful to the National Natural Science Foundation of China(22172040,21974031 and 22204026)the Project Funded by China Postdoctoral Science Foundation(2022M710859)+2 种基金the Department of Science and Techniques of Guangdong Province(2021A1515010180,2019B010933001)Guangzhou Municipal Science and Technology Bureau(202102010449)the Department of Guangdong Provincial Public Security(GZQC20-PZ11-FD084)fortheirfinancial support of thiswork.
文摘The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulfonate)(PEDOT(PSS))was characterized by a developed coulometric signal transduction method.PEDOT(PSS)solid contact is covered by PVC based H+-selective membrane.The obtained coulometric signal demonstrates that the cumulated charge can be amplified by increasing the capacitance of solid contact.SCISEs covered with spin-coated membrane behave faster amperometric response than electrodes with drop-cast mem-brane.In contrast to earlier works,the amperometric response and impedance spectrum demonstrates H+transfer through SCISEs is independent from the thickness of membrane.The exceptional behavior of PANI(Cl)H+-SCISEs shows that the capacitance estimated from impedance spectrum at low frequency 10 mHz and coulometric signal of PANI(Cl)based SCISEs is influenced by the applied po-tentials,whereas PEDOT(PSS)solid contact is independent from the chosen applied potentials.Furthermore,preliminary investiga-tions of coulometric signal transduction on flexible pH sensor implies its potential applications in wearable sensors for sweat ion concentration detection.
文摘Three new 'tailed' porphyrins and their corresponding Mn(Ⅲ) metalloporphyrins were synthesized and characterized. The potentiometric response characteristics of the PVC membrane electrode based on the Mn(Ⅲ) complexes of the three new 'tailed' porphyrins toward SCN- have been studied.
文摘PVC (a poly vinyl chloride) membrane was prepared by using phenyl disulfide as a carrier for selective determination of Pd (II) ion. The membrane can be worked well over a wide concentration range (1.0 × 106-1.0 × 10-1) M with a slope 29.53 mV/decade and a limit of detection (1.77× 10-7) M. The measured of response time was 9 s. It was found to be selective and useable within the pH range (3.0-7.0). The lifetime of membrane sensor prepared could be used for at least 4 months. The electrode was successfully used as an indicator electrode in potentiometric titration of palladium ion with EDTA.
文摘The construction and performance characteristics of a novel Iron(III) membrane sensor based on (37-bis-[(diethoxy-thiophosphoryl)-oxy]-5,11,17,23,29,35-hexa-kis-(1,1-dimethylethyl)-calix[6]-arene-38,39,40,41,42-pentol) (A) were reported in this paper. The sensor was prepared by incorporating compound (A) into a plasticized polyvinyl chloride PVC membrane. The electrode reveals a Nernstian behavior over a wide iron ion concentration range (1.0 × 10-2 - 1.0 × 10-4 mol·L-1), and relatively low detection limit (1.0 × 10-5 mol·L-1). The potentiometric response was independent on the pH of the solution in the range of 4 - 7. The electrode showed a very short response time (<5 s). It exhibited very good selectivity relative to a wide variety of metal cations. Correlation of selectivity coefficient values with ionic radii of interferent cations was discussed. The proposed iron- ISE was applied for analysis of iron containing samples with comparison to a recommended spectrophotometric method.
基金supported by the Key Program of National Natural Science Foundation of China(50934004)National Natural Science Foundation of China(51274061)+1 种基金Major State Basic Research Development Program of China(2012CBA01205)Fundamental Research Supporting Project of Northeastern University(N110602006)
文摘A novel Ce(Ⅳ) ion-selective polyvinyl chloride(PVC) membrane electrode based on HDEHP and HEH/EHP as ionophore was successfully prepared. The factors affecting the response of Ce(Ⅳ) ion were investigated, such as membrane composition, internal solution, concentration of SO_4^(2–), and acidity in test solution. The best performance was obtained using the membrane with PVC:DBP:HDEHP:HEH/EHP:OA mass ratio of 75:175:5:5:5. The proposed electrode exhibited a Nernstian slope of 30.44 mV/decade for Ce(Ⅳ) ion over a linear concentration range of 1×10^(–5)–1×10^(–1) mol/L with the detection limit of 9.0×10^(-6) mol/L. The electrode showed stable response within the SO_4^(2–) concentration range of 0.1–1 mol/L and the acidity range of 0.25–1.2 mol/L H+. The proposed electrode showed high selectivity for Ce(Ⅳ) over a wide variety of interfering ions and a fast response time. It was used as an indicator in the potentiometric titration of Ce(Ⅳ) solution with H_2O_2 solution, and could also be used for the determination of Ce(Ⅳ) in real Ce(Ⅳ)-containing aqueous samples.
基金supported by the Science Foundation of Henan Province(No.142102310336)
文摘The construction,performance characteristics and application of a new bismuth(Ⅲ) PVC membrane electrode based on 5-(3,4,5-trimethoxyphenyl)-4-amino-1,2,4-triazole-3-thiol are reported in this paper.The designed sensor exhibited a Nernstian response for Bi^3+ ion ranging from 5.0×10^-7 mol/L to1.0×10^-2 mol/L with a slope of 19.8 mV/decade.The operational pH range of the sensor is 3.0-6.0.The electrode shows a response time of 6 s and can be used for at least five weeks without any considerable divergence in potentials.It exhibits very good selectivity relative to a wide variety of alkali,alkaline earth,transition and heavy metal ions.The proposed electrode could be used as an indicator electrode in potentiometric titration of Bi^3+ ions with EDTA and in the determination of Bi^3+ content in stomach medicine.
文摘The zwitterionic compound,levofloxacin,was determined for the first time at different pH values in pure samples,pharmaceutical preparations and spiked serum and urine samples.Different types of potentiometric sensors including poly(vinyl chloride)membrane electrode,carbon paste electrode and screen printed electrode,containing the ion pair levofloxaciniumphosphomolybdate as the electroactaive species,were used for this purpose.The effect of pH is the key factor in determining the ratio of the different species that can exist in the medium(zwitterionic,monocationic,dicationic,anionic and neutral),and so it is the controller of the electrochemical performance.The different sensors were fully characterized and optimized in terms of composition,pH effect,selectivity,response and lifetimes.The different sensors showed reliable reversibility and could be utilized for the determination of the drug in real spiked physiological fluids with reliable recovery values.