Based on the monitoring results of environmental quality in the sea area near the Aojiang estuary in Wenzou during 2010-2012,the present situation of environmental quality in the sea area was analyzed and evaluated. T...Based on the monitoring results of environmental quality in the sea area near the Aojiang estuary in Wenzou during 2010-2012,the present situation of environmental quality in the sea area was analyzed and evaluated. The results show that p H,DO,CODMn,petroleum,and heavy metals( Cu,Pb,Zn,Cd,Hg,As and Cr) in the sea area near the Aojiang estuary did not exceed the second-class standard of Seawater Quality Standard( GB 3097-1997),but both inorganic nitrogen and reactive phosphate in the sea area exceeded the second-class standard seriously,and the water quality of the sea area was in an eutrophic state; domestic sewage and fertilizer loss were the main sources of nitrogen and phosphorus. The standard index of most evaluation factors of sediment quality except for Zn was smaller than 1,meeting the demands of sediment quality for environmental protection.展开更多
Based on the monitoring results of environmental quality in Yueqing Bay during 2007-2014,the current situation of environmental quality in the bay was analyzed and assessed. The results show that pH,DO,CODMn,petroleum...Based on the monitoring results of environmental quality in Yueqing Bay during 2007-2014,the current situation of environmental quality in the bay was analyzed and assessed. The results show that pH,DO,CODMn,petroleum,and heavy metals( Cu,Pb,Zn,Cd,Hg,As and Cr)in the seawater of Yueqing Bay did not exceed the second class standard of Seawater Quality Standard( GB 3097-1997),but inorganic nitrogen and reactive phosphate in the seawater of Yueqing Bay exceeded the second class standard seriously,and the water quality of the bay was in an eutrophic state; the standard index of evaluation factors of sediment quality was smaller than 1,meeting the demands of sediment quality for environmental protection.展开更多
Chinese government has adopted a series of management measures to prevent and manage marine pollution and to protect ocean bio resources and ecosystem. The key points of Chinese marine environmental quality status, po...Chinese government has adopted a series of management measures to prevent and manage marine pollution and to protect ocean bio resources and ecosystem. The key points of Chinese marine environmental quality status, pollution monitoring and environmental management since 1980' were discussed in this paper. Those included the investigations of Chinese coast environmental quality, monitoring techniques and standards, as well as the marine environmental management measures. Recent status of marine environmental pollution and the monitoring network in China were also introduced.展开更多
With the acceleration of urbanization and increase of points in power systems,complaints about power grids have increased.In the actual on-site measurement process,although the actual measurement results can meet the ...With the acceleration of urbanization and increase of points in power systems,complaints about power grids have increased.In the actual on-site measurement process,although the actual measurement results can meet the relevant standards,some people are still concerned that the electromagnetic environment may change drastically outside the measurement period,which will have an impact on human health.In this study,the situation of electromagnetic online monitoring systems at home and abroad was introduced firstly,and then some practical requirements for establishing monitoring stations were analyzed.According to existing technologies and related writings,the methods and steps for establishing a quality assurance system were introduced,including the identification of quality assurance system activities and their corresponding structure of quality assurance system documents,the preparation and principles of the documents,and the operation of the quality assurance system.It intends to provide reference for the relevant organizations and personnel conducting electromagnetic environment monitoring when establishing a quality assurance system.Through the establishment of the online monitoring system and the later data publicity,the public have an intuitive understanding of the electromagnetic environment attenuation around power transmission and transformation projects,which can not only make China's electric power industry develop better,but also monitor the unexpected situation in time,maintain public safety and reduce people's fear of electromagnetic radiation in substations.展开更多
Automatic monitoring data of pollution sources is an important basis for environmental supervision and management.At present,it is difficult to guarantee the quality of automatic monitoring data of pollution sources,a...Automatic monitoring data of pollution sources is an important basis for environmental supervision and management.At present,it is difficult to guarantee the quality of automatic monitoring data of pollution sources,and it is difficult to play the role of the monitoring data.In response to this problem,the factors influencing the quality of automatic monitoring data of pollution sources were analyzed in detail,and technical assurance measures for the quality of automatic monitoring data of pollution sources in Shandong Province were studied.Besides,the dynamic management and control idea of automatic monitoring of pollution sources was proposed,and specific technical measures were analyzed from five aspects of standardizing automatic monitoring equipment of pollution sources,improving the data collection and transmission system,establishing a mechanism for reporting operating status information of monitoring equipment,setting alarm rules and alarm processing procedures,and statistically analyzing the operating status of the equipment.Practice has proved that the dynamic management and control system can effectively ensure the quality of automatic monitoring data of pollution sources.展开更多
Environmental protection is an important topic of global concern in recent years,and environmental monitoring is one of the most intuitive and effective means to reflect the environmental situation.With the increasing...Environmental protection is an important topic of global concern in recent years,and environmental monitoring is one of the most intuitive and effective means to reflect the environmental situation.With the increasing task of environmental monitoring,the number of environmental monitoring institutions is increasing.It should strengthen quality management to ensure the accuracy and effectiveness of environmental monitoring results.展开更多
By researching the data quality problem in the monitoring and diagnosis system (MDS) , the method of detecting non-condition data based on the development trend of equipment condition is proposed, and three requirem...By researching the data quality problem in the monitoring and diagnosis system (MDS) , the method of detecting non-condition data based on the development trend of equipment condition is proposed, and three requirements of criteria for detecting non-condition data: dynamic, syntheses and simplicity are discussed. According to the general mode of data management in MDS, a data quality assurance system (DQAS) comprising data quality monitoring, data quality diagnosis, detection criteria adjusting and artificial confirmation is set up. A route inspection system called MTREE realizes the DQAS. Aiming at vibration data of route inspection, two detecting criteria are made. One is the quality monitoring parameter, which is found through combining and optimizing some fundamental parameters by genetic programming (GP). The other is the quality diagnosis criterion, i. e. pseudo distance of Spectral-Energy-Vector (SEV) named Adjacent J-divergence, which indicates the variation degree of adjacent data's spectral energy distribution. Results show that DQAS, including these two criteria, is effective to improve the data quality of MDS.展开更多
In the state of Sao Paulo, Brazil, public policies regarding the air quality aimed at the welfare of the population are strongly dependent on monitoring conducted by the Sao Paulo State Environmental Company (CETESB),...In the state of Sao Paulo, Brazil, public policies regarding the air quality aimed at the welfare of the population are strongly dependent on monitoring conducted by the Sao Paulo State Environmental Company (CETESB), which can be influenced by faulty monitors and equipment support and cuts in power supply, among others. A research conducted from 1998 to 2008 indicated that a significant portion of the air quality automatic stations in the state of Sao Paulo did not meet the criterion of representativeness of measurements of PM10, NO2, O3, CO and SO2 concentrations which resulted in the classification of some municipalities as the nonattainment area, a situation evidenced for PM10 and O3 parameters. The network unavailability for each parameter was estimated and compared with the monitoring networks operated in Canada and the UK. This paper discusses the implications of the lack of representativeness of measurements in the environmental licensing process of pollution sources from 2008, when by the effect of state law, municipalities have been qualified according to their air quality nonattainment level.展开更多
Transfer station(TS)is an integral part of present-day municipal solid waste(MSW)management systems.To provide information for the incorporation of waste facilities within the current integrated waste management syste...Transfer station(TS)is an integral part of present-day municipal solid waste(MSW)management systems.To provide information for the incorporation of waste facilities within the current integrated waste management system,the authors measured the existing environmental quality at five MSW TSs.Discharged wastewater,air,and noise were monitored and assayed at the five TSs in Beijing in 2001-2006 during rainy seasons(RSs)and dry seasons(DSs).Except Ammonia(NH_3)and hydrogen sulfide(H_2S),the analytical results of...展开更多
Environmental sustainability is the rate of renewable resourceharvesting, pollution control, and non-renewable resource exhaustion. Airpollution is a significant issue confronted by the environment particularlyby high...Environmental sustainability is the rate of renewable resourceharvesting, pollution control, and non-renewable resource exhaustion. Airpollution is a significant issue confronted by the environment particularlyby highly populated countries like India. Due to increased population, thenumber of vehicles also continues to increase. Each vehicle has its individualemission rate;however, the issue arises when the emission rate crosses thestandard value and the quality of the air gets degraded. Owing to the technological advances in machine learning (ML), it is possible to develop predictionapproaches to monitor and control pollution using real time data. With thedevelopment of the Internet of Things (IoT) and Big Data Analytics (BDA),there is a huge paradigm shift in how environmental data are employed forsustainable cities and societies, especially by applying intelligent algorithms.In this view, this study develops an optimal AI based air quality prediction andclassification (OAI-AQPC) model in big data environment. For handling bigdata from environmental monitoring, Hadoop MapReduce tool is employed.In addition, a predictive model is built using the hybridization of ARIMAand neural network (NN) called ARIMA-NN to predict the pollution level.For improving the performance of the ARIMA-NN algorithm, the parametertuning process takes place using oppositional swallow swarm optimization(OSSO) algorithm. Finally, Adaptive neuro-fuzzy inference system (ANFIS)classifier is used to classify the air quality into pollutant and non-pollutant.A detailed experimental analysis is performed for highlighting the betterprediction performance of the proposed ARIMA-NN method. The obtainedoutcomes pointed out the enhanced outcomes of the proposed OAI-AQPCtechnique over the recent state of art techniques.展开更多
The development of Chinese system of aquatic environmental monitoring methods was summarized. The existing problem of the system of aquatic environmental monitoring methods was analyzed. At last, some suggestions were...The development of Chinese system of aquatic environmental monitoring methods was summarized. The existing problem of the system of aquatic environmental monitoring methods was analyzed. At last, some suggestions were made on setting and implementing the system of aquat- ic environmental monitoring methods in China.展开更多
ENVISAT/MERIS scenes of Lake Guiers covering the period 2003-2010 were processed for concentration retrieval of chlorophyll a (CHLa), suspended particulate matter (SPM) and colored fraction of dissolved organic matter...ENVISAT/MERIS scenes of Lake Guiers covering the period 2003-2010 were processed for concentration retrieval of chlorophyll a (CHLa), suspended particulate matter (SPM) and colored fraction of dissolved organic matter (CDOM), i.e. the three main parameters relevant to the water quality management of the lake. Estimates in the range of 30 - 117 μg CHLa L<sup>-1</sup> (average 62.13 μg·L<sup>-1</sup>), 0.10 - 29.0 mg SPM L<sup>-1</sup> (average 22.01 mg·L<sup>-1</sup>), and 1.10 - 1.90 CDOM m<sup>-1</sup> (average 1.33 m<sup>-1</sup>) were recorded, suggesting the possibility of occasional poor quality waters in some compartments of the lake. The values calculated as part of this study are consistent with literature data. On the basis of these estimates, interpretations were made as to the feasibility of applying MERIS data for synoptic environmental monitoring purposes. The data were subjected to statistical analysis, including regression analysis and significance tests. Estimates of CHLa and CDOM revealed some level of correlation, which suggests that phytoplankton biomass degradation may account for nearly 47% of the dissolved optical compounds CDOM. Notable areas of high CHLa and CDOM concentrations are found in the southern inshore zone, an environment with less water agitation. In contrast, SPM concentrations tend to increase in environments of very shallow water marked by high water turbulence and bottom mobility. However, it was not possible to fully assess the model performance and detection accuracy of the results due to lack of ground truths. Nonetheless, the results show concentrations that compared well with the insitu data from earlier studies and data reported elsewhere from other lacustrine systems. Therefore, it can be inferred from this study that MERIS data present a useful low-cost (i.e. cost effective and readily available) approach for environmental monitoring of Lake Guiers waters with excellent spatial coverage. In addition, the study highlighted the minimal effect of the so-called “bottom effect” on model predictions, despite the small depth of the lake.展开更多
In a local context, sustainable development entails utilizing the current resources—material and immaterial, measurable and immeasurable, popular and unpopular—of the community in a manner that avoids overexploitati...In a local context, sustainable development entails utilizing the current resources—material and immaterial, measurable and immeasurable, popular and unpopular—of the community in a manner that avoids overexploitation and ensures intergenerational equity. This approach prioritizes the safety and health of local citizens, placing communal productivity above corporate profitability. This research aims to assess air quality surrounding 28 chemical industry sites in Baton Rouge, Louisiana, to understand the environmental and health impacts of industrial pollutants, with a focus on environmental justice. Air quality pollutants, including PM2.5, PM10, O3, NO2, CO, and SO2, were monitored for 75 days during the Summer, using the BreezoMeter app. Python, Mapize, and QGIS software technologies were utilized for data analysis and visualization. Findings indicate a reduction in NO2 and CO levels, compared to existing literature. However, the persistent challenge of particulate matter suggests areas for further environmental management efforts. Additionally, the research suggests a significant disparity in air pollution exposure, probably affecting marginalized communities. Although the nature of the study might not fully capture annual pollution trends, the findings highlight the urgent need for the chemical industry to adopt efficient production methods and for policymakers to enhance air quality standards and enforcement, particularly in pollution-sensitive areas. The disproportionate impact of air pollution on vulnerable communities calls for a more inclusive approach to environmental justice, ensuring equitable distribution of clean air benefits and community involvement in pollution management decisions.展开更多
The underground water has been contaminated seriously by the leaching water of dumping area or hillock. To determine the pollution limits of underground water, author took samples in the study area, analyzed samples f...The underground water has been contaminated seriously by the leaching water of dumping area or hillock. To determine the pollution limits of underground water, author took samples in the study area, analyzed samples for water quality, assessed the water quality of each monitoring point by the grey associated analysis method, and gave out the classifications of the underground water quality of the study area. Comparing with fuzzy comprehensive appraisal method, it is demonstrated that grey associated analysis method is applied easily, because of its clear concept, simple and convenient calculation and excellently operation.展开更多
Indoor environmental quality(IEQ)significantly affects human health and wellbeing.Therefore,continuous IEQ monitoring and feedback is of great concern in both the industrial and academic communities.However,most exist...Indoor environmental quality(IEQ)significantly affects human health and wellbeing.Therefore,continuous IEQ monitoring and feedback is of great concern in both the industrial and academic communities.However,most existing studies only focus on developing sensors that cost-effectively promote IEQ measurement while ignoring interactions between the human side and IEQ monitoring.In this study,an intelligent IEQ monitoring and feedback system-the Intelligent Built Enviroment(IBEM)-is developed.Firstly,the IBEM hardware instrument integrates air temperature,relative humidity,CO_(2),particulate matter with an aerodynamic diameter no greater than _(2.5)μm(PM_(2.5)),and illuminance sensors within a small device.The accuracy of this integrated device was tested through a co-location experiment with reference sensors;the device exhibited a strong correlation with the reference sensors,with a slight deviation(R^(2)>0.97 and slopes between 1.01 and 1.05).Secondly,a wireless data transmission module,a cloud storage module,and graphical user interfaces(i.e.,a web platform and mobile interface)were built to establish a pathway for dataflow and interactive feedback with the occupants of the indoor environments.Thus,the IEQ parameters can be continuously monitored with a high spatiotemporal resolution,interactive feedback can be induced,and synchronous data collection on occupant satisfaction and objective environmental parameters can be realized.IBEM has been widely applied in 131 buildings in 18cities/areas in China,with 1188 sample locations.Among these applications,we report on the targeted IEQ diagnoses of two individual buildings and the exploration of relationships between subjective and objective IEQ data in detail here.This work demonstrates the great value of IBEM in both industrial and academic research.展开更多
With the atmospheric stereoscopic monitoring, air quality forecasting and decision of environment management as the main line, and comprehensive management system as the guidance, five platforms including infrastruct...With the atmospheric stereoscopic monitoring, air quality forecasting and decision of environment management as the main line, and comprehensive management system as the guidance, five platforms including infrastructure, technological support, monitoring and early monitoring, decision support and information services were established. These platforms have 15 subsystems, including stereoscopic monitoring network, visual business consultation, high-performance computing environment, comprehensive management of atmospheric data, emission inventories of pollu-tion sources, evaluation tools of atmospheric models, monitoring and management of air pollution, forecasting and early warning of air quality, diag-nostic analysis of atmospheric environment, tracking of air pollution sources, emergency management of air pollution, conformity management of air quality, comprehensive display of information, releasing of information to external networks, and releasing of information by mobile networks. The decision support system (DSS) of atmospheric environment management could realize an integration business system of 11 air quality forecast - heavy pollution weather warning - diagnosis of pollution causes (dynamic analysis of pollution sources) -air quality conformity planning (air pollu-tion emergency management) -evaluation of forecasting and warning results (evaluation pf management measures) -air quality forecasting" and provide the technical support for the prevention and control of atmosphere pollution in Anhui province.展开更多
Research works of Wireless Sensor Networks (WSNs) applications and its constraints solutions occupy wide area around the world and attract many researchers. In this paper, an important one of environmental WSN applica...Research works of Wireless Sensor Networks (WSNs) applications and its constraints solutions occupy wide area around the world and attract many researchers. In this paper, an important one of environmental WSN applications is presented that is the water monitoring applications. An efficient approach for monitoring and controlling water parameters in real-time is implemented utilizing merging between WSN and designed simple workstation. For implementation simplicity, two water parameters (pH and temperature) are monitored and controlled in the proposed approach. Most of past work of water monitoring presented different proposed monitoring scenarios for different water parameters only. This research work utilizes the concept of interactive WSN nodes. The interactive nodes interact with the monitored water parameters to control its value. In the base station, the collected data is analyzed and the real-time value of the monitored parameters appears on the designed Graphic User Interface (GUI). The GUI is designed using the Matlab program. Through the GUI, the operator can switch the control between automatic and manual. ZigBee module is used for implementing the wireless communications between the nodes and the workstation. Due to the cost and simplicity, two sensors only are used in the proposed approach. Different real-time experiments are performed to test and measure the effectiveness and performance of the presented approach. These experiments reveal that the presented approach is effective for water treatment and efficient more than the past proposed water monitoring scenarios.展开更多
Tool wear, chatter vibration, chip breaking and built up edge are main phenomena to be monitored in modern manufacturing processes, which are considered as important factors to the quality of products. They are closel...Tool wear, chatter vibration, chip breaking and built up edge are main phenomena to be monitored in modern manufacturing processes, which are considered as important factors to the quality of products. They are closely related to the cutting parameters, which are to be selected in manufacturing process. However, it is very difficult to measure directly the cutting quality based on on line monitoring. In this study, the relationship between the cutting parameters and cutting quality is analyzed. A Radical Basis Function (RBF) neural network based on line quality recognition scheme is also presented, which monitors the level of surface roughness. The experimental results reveal that the RBF neural network has a high prediction success rate.展开更多
文摘Based on the monitoring results of environmental quality in the sea area near the Aojiang estuary in Wenzou during 2010-2012,the present situation of environmental quality in the sea area was analyzed and evaluated. The results show that p H,DO,CODMn,petroleum,and heavy metals( Cu,Pb,Zn,Cd,Hg,As and Cr) in the sea area near the Aojiang estuary did not exceed the second-class standard of Seawater Quality Standard( GB 3097-1997),but both inorganic nitrogen and reactive phosphate in the sea area exceeded the second-class standard seriously,and the water quality of the sea area was in an eutrophic state; domestic sewage and fertilizer loss were the main sources of nitrogen and phosphorus. The standard index of most evaluation factors of sediment quality except for Zn was smaller than 1,meeting the demands of sediment quality for environmental protection.
基金Supported by National Natural Science Foundation of China(4127-6199)
文摘Based on the monitoring results of environmental quality in Yueqing Bay during 2007-2014,the current situation of environmental quality in the bay was analyzed and assessed. The results show that pH,DO,CODMn,petroleum,and heavy metals( Cu,Pb,Zn,Cd,Hg,As and Cr)in the seawater of Yueqing Bay did not exceed the second class standard of Seawater Quality Standard( GB 3097-1997),but inorganic nitrogen and reactive phosphate in the seawater of Yueqing Bay exceeded the second class standard seriously,and the water quality of the bay was in an eutrophic state; the standard index of evaluation factors of sediment quality was smaller than 1,meeting the demands of sediment quality for environmental protection.
文摘Chinese government has adopted a series of management measures to prevent and manage marine pollution and to protect ocean bio resources and ecosystem. The key points of Chinese marine environmental quality status, pollution monitoring and environmental management since 1980' were discussed in this paper. Those included the investigations of Chinese coast environmental quality, monitoring techniques and standards, as well as the marine environmental management measures. Recent status of marine environmental pollution and the monitoring network in China were also introduced.
基金Supported by the Open Project of Jiangsu Key Laboratory of Environmental Engineering(ZX2017005)
文摘With the acceleration of urbanization and increase of points in power systems,complaints about power grids have increased.In the actual on-site measurement process,although the actual measurement results can meet the relevant standards,some people are still concerned that the electromagnetic environment may change drastically outside the measurement period,which will have an impact on human health.In this study,the situation of electromagnetic online monitoring systems at home and abroad was introduced firstly,and then some practical requirements for establishing monitoring stations were analyzed.According to existing technologies and related writings,the methods and steps for establishing a quality assurance system were introduced,including the identification of quality assurance system activities and their corresponding structure of quality assurance system documents,the preparation and principles of the documents,and the operation of the quality assurance system.It intends to provide reference for the relevant organizations and personnel conducting electromagnetic environment monitoring when establishing a quality assurance system.Through the establishment of the online monitoring system and the later data publicity,the public have an intuitive understanding of the electromagnetic environment attenuation around power transmission and transformation projects,which can not only make China's electric power industry develop better,but also monitor the unexpected situation in time,maintain public safety and reduce people's fear of electromagnetic radiation in substations.
文摘Automatic monitoring data of pollution sources is an important basis for environmental supervision and management.At present,it is difficult to guarantee the quality of automatic monitoring data of pollution sources,and it is difficult to play the role of the monitoring data.In response to this problem,the factors influencing the quality of automatic monitoring data of pollution sources were analyzed in detail,and technical assurance measures for the quality of automatic monitoring data of pollution sources in Shandong Province were studied.Besides,the dynamic management and control idea of automatic monitoring of pollution sources was proposed,and specific technical measures were analyzed from five aspects of standardizing automatic monitoring equipment of pollution sources,improving the data collection and transmission system,establishing a mechanism for reporting operating status information of monitoring equipment,setting alarm rules and alarm processing procedures,and statistically analyzing the operating status of the equipment.Practice has proved that the dynamic management and control system can effectively ensure the quality of automatic monitoring data of pollution sources.
文摘Environmental protection is an important topic of global concern in recent years,and environmental monitoring is one of the most intuitive and effective means to reflect the environmental situation.With the increasing task of environmental monitoring,the number of environmental monitoring institutions is increasing.It should strengthen quality management to ensure the accuracy and effectiveness of environmental monitoring results.
基金This paper is supported by National Natural Science Foundation of China under Grant No.50335030
文摘By researching the data quality problem in the monitoring and diagnosis system (MDS) , the method of detecting non-condition data based on the development trend of equipment condition is proposed, and three requirements of criteria for detecting non-condition data: dynamic, syntheses and simplicity are discussed. According to the general mode of data management in MDS, a data quality assurance system (DQAS) comprising data quality monitoring, data quality diagnosis, detection criteria adjusting and artificial confirmation is set up. A route inspection system called MTREE realizes the DQAS. Aiming at vibration data of route inspection, two detecting criteria are made. One is the quality monitoring parameter, which is found through combining and optimizing some fundamental parameters by genetic programming (GP). The other is the quality diagnosis criterion, i. e. pseudo distance of Spectral-Energy-Vector (SEV) named Adjacent J-divergence, which indicates the variation degree of adjacent data's spectral energy distribution. Results show that DQAS, including these two criteria, is effective to improve the data quality of MDS.
文摘In the state of Sao Paulo, Brazil, public policies regarding the air quality aimed at the welfare of the population are strongly dependent on monitoring conducted by the Sao Paulo State Environmental Company (CETESB), which can be influenced by faulty monitors and equipment support and cuts in power supply, among others. A research conducted from 1998 to 2008 indicated that a significant portion of the air quality automatic stations in the state of Sao Paulo did not meet the criterion of representativeness of measurements of PM10, NO2, O3, CO and SO2 concentrations which resulted in the classification of some municipalities as the nonattainment area, a situation evidenced for PM10 and O3 parameters. The network unavailability for each parameter was estimated and compared with the monitoring networks operated in Canada and the UK. This paper discusses the implications of the lack of representativeness of measurements in the environmental licensing process of pollution sources from 2008, when by the effect of state law, municipalities have been qualified according to their air quality nonattainment level.
文摘Transfer station(TS)is an integral part of present-day municipal solid waste(MSW)management systems.To provide information for the incorporation of waste facilities within the current integrated waste management system,the authors measured the existing environmental quality at five MSW TSs.Discharged wastewater,air,and noise were monitored and assayed at the five TSs in Beijing in 2001-2006 during rainy seasons(RSs)and dry seasons(DSs).Except Ammonia(NH_3)and hydrogen sulfide(H_2S),the analytical results of...
基金The authors extend their appreciation to the Deanship of Scientific Research at King Khalid University for funding this work under grant number(RGP2/45/43)Princess Nourah bint Abdulrahman University Researchers Supporting Project number(PNURSP2022R135)Princess Nourah bint Abdulrahman University,Riyadh,Saudi Arabia.The authors would like to thank the Deanship of Scientific Research at Umm Al-Qura University for supporting this work by Grant Code:(22UQU4270206DSR02).
文摘Environmental sustainability is the rate of renewable resourceharvesting, pollution control, and non-renewable resource exhaustion. Airpollution is a significant issue confronted by the environment particularlyby highly populated countries like India. Due to increased population, thenumber of vehicles also continues to increase. Each vehicle has its individualemission rate;however, the issue arises when the emission rate crosses thestandard value and the quality of the air gets degraded. Owing to the technological advances in machine learning (ML), it is possible to develop predictionapproaches to monitor and control pollution using real time data. With thedevelopment of the Internet of Things (IoT) and Big Data Analytics (BDA),there is a huge paradigm shift in how environmental data are employed forsustainable cities and societies, especially by applying intelligent algorithms.In this view, this study develops an optimal AI based air quality prediction andclassification (OAI-AQPC) model in big data environment. For handling bigdata from environmental monitoring, Hadoop MapReduce tool is employed.In addition, a predictive model is built using the hybridization of ARIMAand neural network (NN) called ARIMA-NN to predict the pollution level.For improving the performance of the ARIMA-NN algorithm, the parametertuning process takes place using oppositional swallow swarm optimization(OSSO) algorithm. Finally, Adaptive neuro-fuzzy inference system (ANFIS)classifier is used to classify the air quality into pollutant and non-pollutant.A detailed experimental analysis is performed for highlighting the betterprediction performance of the proposed ARIMA-NN method. The obtainedoutcomes pointed out the enhanced outcomes of the proposed OAI-AQPCtechnique over the recent state of art techniques.
基金Supported by Study on Water Environment Quality Monitoring Technological Method (2009ZX07527-001)Chongqing Natural Science Fund (CSTC,2009B137391)
文摘The development of Chinese system of aquatic environmental monitoring methods was summarized. The existing problem of the system of aquatic environmental monitoring methods was analyzed. At last, some suggestions were made on setting and implementing the system of aquat- ic environmental monitoring methods in China.
文摘ENVISAT/MERIS scenes of Lake Guiers covering the period 2003-2010 were processed for concentration retrieval of chlorophyll a (CHLa), suspended particulate matter (SPM) and colored fraction of dissolved organic matter (CDOM), i.e. the three main parameters relevant to the water quality management of the lake. Estimates in the range of 30 - 117 μg CHLa L<sup>-1</sup> (average 62.13 μg·L<sup>-1</sup>), 0.10 - 29.0 mg SPM L<sup>-1</sup> (average 22.01 mg·L<sup>-1</sup>), and 1.10 - 1.90 CDOM m<sup>-1</sup> (average 1.33 m<sup>-1</sup>) were recorded, suggesting the possibility of occasional poor quality waters in some compartments of the lake. The values calculated as part of this study are consistent with literature data. On the basis of these estimates, interpretations were made as to the feasibility of applying MERIS data for synoptic environmental monitoring purposes. The data were subjected to statistical analysis, including regression analysis and significance tests. Estimates of CHLa and CDOM revealed some level of correlation, which suggests that phytoplankton biomass degradation may account for nearly 47% of the dissolved optical compounds CDOM. Notable areas of high CHLa and CDOM concentrations are found in the southern inshore zone, an environment with less water agitation. In contrast, SPM concentrations tend to increase in environments of very shallow water marked by high water turbulence and bottom mobility. However, it was not possible to fully assess the model performance and detection accuracy of the results due to lack of ground truths. Nonetheless, the results show concentrations that compared well with the insitu data from earlier studies and data reported elsewhere from other lacustrine systems. Therefore, it can be inferred from this study that MERIS data present a useful low-cost (i.e. cost effective and readily available) approach for environmental monitoring of Lake Guiers waters with excellent spatial coverage. In addition, the study highlighted the minimal effect of the so-called “bottom effect” on model predictions, despite the small depth of the lake.
文摘In a local context, sustainable development entails utilizing the current resources—material and immaterial, measurable and immeasurable, popular and unpopular—of the community in a manner that avoids overexploitation and ensures intergenerational equity. This approach prioritizes the safety and health of local citizens, placing communal productivity above corporate profitability. This research aims to assess air quality surrounding 28 chemical industry sites in Baton Rouge, Louisiana, to understand the environmental and health impacts of industrial pollutants, with a focus on environmental justice. Air quality pollutants, including PM2.5, PM10, O3, NO2, CO, and SO2, were monitored for 75 days during the Summer, using the BreezoMeter app. Python, Mapize, and QGIS software technologies were utilized for data analysis and visualization. Findings indicate a reduction in NO2 and CO levels, compared to existing literature. However, the persistent challenge of particulate matter suggests areas for further environmental management efforts. Additionally, the research suggests a significant disparity in air pollution exposure, probably affecting marginalized communities. Although the nature of the study might not fully capture annual pollution trends, the findings highlight the urgent need for the chemical industry to adopt efficient production methods and for policymakers to enhance air quality standards and enforcement, particularly in pollution-sensitive areas. The disproportionate impact of air pollution on vulnerable communities calls for a more inclusive approach to environmental justice, ensuring equitable distribution of clean air benefits and community involvement in pollution management decisions.
文摘The underground water has been contaminated seriously by the leaching water of dumping area or hillock. To determine the pollution limits of underground water, author took samples in the study area, analyzed samples for water quality, assessed the water quality of each monitoring point by the grey associated analysis method, and gave out the classifications of the underground water quality of the study area. Comparing with fuzzy comprehensive appraisal method, it is demonstrated that grey associated analysis method is applied easily, because of its clear concept, simple and convenient calculation and excellently operation.
基金supported by the China National Key Research and Development(R&D)Program(2018YFE0106100)the National Science Foundation for Distinguished Young Scholars of China(51825802)+3 种基金the Innovative Research Groups of the National Natural Science Foundation of China(51521005)the Strategic Research and Consulting Project of Chinese Academy of Engineering(2021XY-3)the China Postdoctoral Science Foundation(2021M691789)Shuimu Tsinghua Scholar Program(2020SM001)。
文摘Indoor environmental quality(IEQ)significantly affects human health and wellbeing.Therefore,continuous IEQ monitoring and feedback is of great concern in both the industrial and academic communities.However,most existing studies only focus on developing sensors that cost-effectively promote IEQ measurement while ignoring interactions between the human side and IEQ monitoring.In this study,an intelligent IEQ monitoring and feedback system-the Intelligent Built Enviroment(IBEM)-is developed.Firstly,the IBEM hardware instrument integrates air temperature,relative humidity,CO_(2),particulate matter with an aerodynamic diameter no greater than _(2.5)μm(PM_(2.5)),and illuminance sensors within a small device.The accuracy of this integrated device was tested through a co-location experiment with reference sensors;the device exhibited a strong correlation with the reference sensors,with a slight deviation(R^(2)>0.97 and slopes between 1.01 and 1.05).Secondly,a wireless data transmission module,a cloud storage module,and graphical user interfaces(i.e.,a web platform and mobile interface)were built to establish a pathway for dataflow and interactive feedback with the occupants of the indoor environments.Thus,the IEQ parameters can be continuously monitored with a high spatiotemporal resolution,interactive feedback can be induced,and synchronous data collection on occupant satisfaction and objective environmental parameters can be realized.IBEM has been widely applied in 131 buildings in 18cities/areas in China,with 1188 sample locations.Among these applications,we report on the targeted IEQ diagnoses of two individual buildings and the exploration of relationships between subjective and objective IEQ data in detail here.This work demonstrates the great value of IBEM in both industrial and academic research.
基金Supported by the National Science and Technology Support Plan(2014BAC22B06)Public Welfare Research Project of Science and Technology Department of Anhui Province in 2017(1704f0804056)
文摘With the atmospheric stereoscopic monitoring, air quality forecasting and decision of environment management as the main line, and comprehensive management system as the guidance, five platforms including infrastructure, technological support, monitoring and early monitoring, decision support and information services were established. These platforms have 15 subsystems, including stereoscopic monitoring network, visual business consultation, high-performance computing environment, comprehensive management of atmospheric data, emission inventories of pollu-tion sources, evaluation tools of atmospheric models, monitoring and management of air pollution, forecasting and early warning of air quality, diag-nostic analysis of atmospheric environment, tracking of air pollution sources, emergency management of air pollution, conformity management of air quality, comprehensive display of information, releasing of information to external networks, and releasing of information by mobile networks. The decision support system (DSS) of atmospheric environment management could realize an integration business system of 11 air quality forecast - heavy pollution weather warning - diagnosis of pollution causes (dynamic analysis of pollution sources) -air quality conformity planning (air pollu-tion emergency management) -evaluation of forecasting and warning results (evaluation pf management measures) -air quality forecasting" and provide the technical support for the prevention and control of atmosphere pollution in Anhui province.
文摘Research works of Wireless Sensor Networks (WSNs) applications and its constraints solutions occupy wide area around the world and attract many researchers. In this paper, an important one of environmental WSN applications is presented that is the water monitoring applications. An efficient approach for monitoring and controlling water parameters in real-time is implemented utilizing merging between WSN and designed simple workstation. For implementation simplicity, two water parameters (pH and temperature) are monitored and controlled in the proposed approach. Most of past work of water monitoring presented different proposed monitoring scenarios for different water parameters only. This research work utilizes the concept of interactive WSN nodes. The interactive nodes interact with the monitored water parameters to control its value. In the base station, the collected data is analyzed and the real-time value of the monitored parameters appears on the designed Graphic User Interface (GUI). The GUI is designed using the Matlab program. Through the GUI, the operator can switch the control between automatic and manual. ZigBee module is used for implementing the wireless communications between the nodes and the workstation. Due to the cost and simplicity, two sensors only are used in the proposed approach. Different real-time experiments are performed to test and measure the effectiveness and performance of the presented approach. These experiments reveal that the presented approach is effective for water treatment and efficient more than the past proposed water monitoring scenarios.
基金SupportedbytheResearchFundofKumohNationalUniversityofTechnology R .Korea
文摘Tool wear, chatter vibration, chip breaking and built up edge are main phenomena to be monitored in modern manufacturing processes, which are considered as important factors to the quality of products. They are closely related to the cutting parameters, which are to be selected in manufacturing process. However, it is very difficult to measure directly the cutting quality based on on line monitoring. In this study, the relationship between the cutting parameters and cutting quality is analyzed. A Radical Basis Function (RBF) neural network based on line quality recognition scheme is also presented, which monitors the level of surface roughness. The experimental results reveal that the RBF neural network has a high prediction success rate.