A selective and sensitive competitive enzyme-linked immunosorbent assay(ELISA) method was developed and validated for the quantification of erlotinib in 50 mL of samples of human serum. Anti-erlotinib serum was obtain...A selective and sensitive competitive enzyme-linked immunosorbent assay(ELISA) method was developed and validated for the quantification of erlotinib in 50 mL of samples of human serum. Anti-erlotinib serum was obtained by immunizing mice with an antigen conjugated with bovine serum albumin and 3,4-bis(2-methoxyethoxy)benzoic acid using the N-succinimidyl ester method. Enzyme labeling of erlotinib with horseradish peroxidase was similarly performed using 3,4-bis(2-methoxyethoxy)benzoic acid. A simple competitive ELISA for erlotinib was developed using the principle of direct competition between erlotinib and the enzyme marker for anti-erlotinib antibody, which had been immobilized on the plastic surface of a microtiter plate. Serum erlotinib concentrations lower than 40 ng/mL were reproducibly measurable using the ELISA. This ELISA was specific to erlotinib and showed very slight cross-reactivity(6.7%) with a major metabolite, O-desmethyl erlotinib. Using this assay, drug levels were easily measured in the blood of mice after oral administration of erlotinib at a single dose of 30 mg/kg. ELISA should be used as a valuable tool for therapeutic drug monitoring and in pharmacokinetic studies of erlotinib.展开更多
A total of 66 samples (from 27 cases with neuromyelitis optica, 26 cases with multiple sclerosis, aa 13 cases with optic neuritis) were tested for aquaporin-4 antibody by a cell-based immunofluorescence assay and an...A total of 66 samples (from 27 cases with neuromyelitis optica, 26 cases with multiple sclerosis, aa 13 cases with optic neuritis) were tested for aquaporin-4 antibody by a cell-based immunofluorescence assay and an enzyme-linked immunosorbent assay. The sensitivities and specificities of the two assays were similar. We further analyzed an additional 68 patients and 93 healthy controls using the enzyme-linked immunosorbent assay. A Kappa test showed good consistency between the two methods in terms of detection of anti-aquaporin-4 antibody in the se of neuromyelitis optica patients. No significant correlations were identified with onset age or disea duration, suggesting that aquaporin-4 antibody is a good marker for neuromyelitis optica. The enzyme-linked immunosorbent assay can be used for quantifying aquaporin-4 antibody concentrations and may be useful to dynamically monitor changes in the levels of aquaporin-4 antibody during disease duration.展开更多
During the course of study, we found that both poly (N-isopropylacrylamide ) (PNIP) and PNIP-Ab (enzyme-labelled antibody)could be adhere tightly to a cellulose acetale-nitrate membrane, and that the retention of PNI...During the course of study, we found that both poly (N-isopropylacrylamide ) (PNIP) and PNIP-Ab (enzyme-labelled antibody)could be adhere tightly to a cellulose acetale-nitrate membrane, and that the retention of PNIP-Ab on the membrane increased over 30-fold when compared with the unconjugated Ab.Thus we used this characteristic to develop a novel immunoassay method-polymer enzyme linked immunoassay method: homogeneous antigen-antibody reaction and heterogeneous separation process. When applied for detection of human serum HBsAg, this immunoassay system can detect as little as 1 ng/ml of human serum HBsAg.展开更多
The simple rapid and sensitive enzyme-linked immunosorbent assay (ELISA) methods, di-rect and indirect ELISA, for quantitation of ochratoxin A in cereal had been developed by theutilization of monoclonal antibody on i...The simple rapid and sensitive enzyme-linked immunosorbent assay (ELISA) methods, di-rect and indirect ELISA, for quantitation of ochratoxin A in cereal had been developed by theutilization of monoclonal antibody on immunomicroplate. Direct FLIAS was found to be less timeconsuming than indirect ELISA. For direct FLISA, recovery of 1 -500 ppb OA added to wheat was78.9-100.0% and rice was 88.9- 120.0%. For indirect EI.IAS, recovery of 1-500 ppb OA addedto wheat was 79.0- 110.0% and rice was 82.0 120.0%. The minimal detection level for OA was Ippb. Analyses of 31 samples that caused humanintoxicant for OA showed that the ELISA resultsagreed wtll with those obtained by thin-layer chromatogrdphy.展开更多
Afatinib is an oral tyrosine kinase inhibitor(TKI) approved for treating advanced non-small cell lung cancer. It is necessary to develop a simple quantification method for TKIs in order to facilitate therapeutic drug ...Afatinib is an oral tyrosine kinase inhibitor(TKI) approved for treating advanced non-small cell lung cancer. It is necessary to develop a simple quantification method for TKIs in order to facilitate therapeutic drug monitoring(TDM) in clinical settings. This study sought to develop a simple and sensitive competitive enzyme-linked immunosorbent assay(ELISA) to quantify afatinib in plasma for routine pharmacokinetic applications. An anti-afatinib antibody was obtained using(S)-N-4-(3-chloro-4-fluorophenyl)-7-(tetrahydrofuran-3-yloxy)-quinazoline-4,6-diamine(CTQD), which has the same substructure as afatinib, as a hapten. Enzyme labeling of afatinib with horseradish peroxidase was similarly performed using CTQD. A simple competitive ELISA for afatinib was developed based on the principle of direct competition between afatinib and the enzyme marker for the anti-afatinib antibody, which had been immobilized on the plastic surface of a microtiter plate. Plasma afatinib concentrations below the limit of quantification of 30 pg/mL were reproducibly measurable. Also, the values of plasma afatinib levels measured from 20 patients were comparable with those measured by high-performance liquid chromatography, and there was a strong correlation between the values determined by both methods(Y=0.976 X – 0.207, r=0.975). As indicated by its specificity and sensitivity, this newly developed ELISA for afatinib is an important tool for TDM and studies of the pharmacokinetics of afatinib.展开更多
Mycoplasma mycoides subsp mycoides SC (MmmSC) is the etiological agent of contagious bovine pleuropneumonia (CBPP). The lipoprotein LppQ encoded by lppQ gene is specific to MmmSC and is found in the type strain an...Mycoplasma mycoides subsp mycoides SC (MmmSC) is the etiological agent of contagious bovine pleuropneumonia (CBPP). The lipoprotein LppQ encoded by lppQ gene is specific to MmmSC and is found in the type strain and in field strains isolated in Europe, Africa, and Australia, as well as in vaccine strains. No serological cross-reactions were observed with the related mycoplasmas of the Mycoplasma mycoides cluster. The N-terminal domain of the mature lipoprotein LppQ is hydrophilic, and it induces a strong, specific, early, and persistent immune response in naturally and experimentally infected animals. Mycoplasma-specific TGA (Trp) codons are utilized as stop codons in most other organisms. The lppQ N-terminal fragment from MmmSC HVRI X strain, the Chinese strain for CF antigen production, was mutated with one-step overlapping extension PCR. Sequence analysis confirmed the successful mutation from A to G in codon 198 in the lppQ gene. The fragment containing the mutation site was subcloned into the pET32a expression vector. The recombinant protein with molecular weight of 42 kDa was purified using the Ni-NTA His.Bind purification kit, with a purity of up to 95%. Western blot indicated that the standard positive serum of CBPP could react with the recombinant protein. The purified protein was diluted to 0.35 μg mL^-1, and coated to microtiter enzyme-linked immunosorbent assay (ELISA) plates. Indirect ELISA reaction conditions were optimized. The value of P/N was determined to be 4.8 (0.934/0.193), the sensitivity to be 95.8% (46/48), and the specificity to be 98.9% (161/163). 3 817 cattle serum samples from three different provinces were detected by the indirect ELISA and CFT. The Kappa value is 0.63, which is middle or high agreement between the two methods.展开更多
Anti-bungarotoxin anti-serum,which has the internal image of nicotinicacetylcholine receptor,was used as a tool to measure anti-idiotypic antibodies toantibodies to Iigand of nicotinic acctylcholine receptor in scra f...Anti-bungarotoxin anti-serum,which has the internal image of nicotinicacetylcholine receptor,was used as a tool to measure anti-idiotypic antibodies toantibodies to Iigand of nicotinic acctylcholine receptor in scra from 81 patients withmyasthenia gravis.Enzyme-linked immunosorbcnt assay was adopted.Thc positive ratewas 46.9%(38/81).The specific cross inhibitory test with nicotinic acetylcholinereceptor was positive.Anti-idiotype antibodies to antibodies to ligand of nicotinicacetylcholine receptor in sera of different types of myasthenia gravis patients classified ac-cording to modified Osserman’s standard and myasthenia gravis patients with or withoutthymoma were comparcd in this study and the role of anti-idiotype antibodies toantibodies to Iigand of nicotinic acctylcholinc receptor in the immunity of myasthcniagravis and the possibility of thcrapeutic use of anti-idiotype antibodies arc discussed.展开更多
In thes paper the authors used the Horseradish peroxidase labelledstaphylococcal protein A(HRP—SPA)in ELISA,for the detection of Clo-norchis sinensis infection.Serum tests were made on 116 confirmed cases ofclonorchi...In thes paper the authors used the Horseradish peroxidase labelledstaphylococcal protein A(HRP—SPA)in ELISA,for the detection of Clo-norchis sinensis infection.Serum tests were made on 116 confirmed cases ofclonorchiasis,103(88.8%)of them showed positive,while only 6(4.4%)werepositive among 138 healthy people.Samples were collected on filter paperstrips,111(95.7%)cases were positive among 116 comfirmed cases tested,but only 2(1.5%)were positive out of 138 healthy persons.The resultswere similar to those obtained by sheep antihuman IgG.Animal experimentalso showed that the SPA—ELISA can be used for the diagnosis ofclonorchiasis.In an endemic area,stool egg positive rate was 8.8%(62/703).whenchecked with SPA—ELISA,the rate of conformity in both filter paperstrips and stool examinations was 90.3(56/62).Among 641 serum testsfrom individuals negative in stool examinations,only 35(5.5%)reactedpositively.The authors suggested—that SPA—ELISA with soluble Clo-norchis antigens could be used in a large scale seroepidemiological surveyin endemic areas.展开更多
Enzyme-linked immunosorbent assay (ELISA) is the most widely used method for measuring a single cytokine. Recent developments in cytokine quantification such as multiple arrays measure multiple cytokines simultaneousl...Enzyme-linked immunosorbent assay (ELISA) is the most widely used method for measuring a single cytokine. Recent developments in cytokine quantification such as multiple arrays measure multiple cytokines simultaneously. Although good correlations between ELISA and multiplex methods have been observed, side by side comparisons are limited. In the present study we hypothesized that ELISA and Luminex techniques are comparable in detecting cytokines in culture medium when pulmonary artery smooth muscle cells (PASMC) are exposed to stress. Primary human PASMC were cultured in modular chambers and exposed to 21% FiO2 and peak inspiratory and positive end expiratory pressure of 24 and 8 cmH2O respectively, and 95% FiO2. At 24 hours, culture medium was collected and assayed for interleukin-6 (IL-6) and IL-8 by quantitative ELISA and by Human Cytokine 25-Plex Panel using a Luminex 200 analyzer. A comparative analysis of agreement between our ELISA and Luminex data was detailed for control and stress conditions using the Bland-Altman plot analysis. Each assay resulted in comparable increased (p < 0.001) levels of IL-6 and IL-8 as compared to control in response to oxidative and biophysical stress. The Bland-Altman analysis demonstrated that 95% of the differences between ELISA and Luminex values were within ±1.96 SD from the mean difference indicated by the 95% limits of agreement for the measurements of IL-6 and IL-8. There was no systematic bias as a function of inflammation level. We conclude that in this cell culture model, ELISA and Luminex are comparable in detecting the levels of IL-6 and IL-8 in the culture medium. If measurements of multiple cytokines are demanded and the amount of sample is limited, Luminex multi-analyte profiling technology is accurate and sensitive.展开更多
A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELI...A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELISA).A systematic comparison between the MmPs-CLEIA and colorimetric ELISA concluded that the MPs-CLEIA exhibited fewer dosages of immunoreagents,less total assay time,and better linearity,recovery,precision,sensitivity and validity.AFP was detected in forty human serum samples by the proposed MPs-CLEIA and ELISA,and the results were compared with commercial electrochemiluminescence immunoassay (ECLIA) kit.The correlation coefficient between MPs-CLEIA and ELISA was obtained with R 2 0.6703;however,the correlation between MPs-CLEIA and ECLIA (R 2 0.9582) was obviously better than that between colorimetric ELISA and ECLIA (R 2 0.6866).展开更多
文摘A selective and sensitive competitive enzyme-linked immunosorbent assay(ELISA) method was developed and validated for the quantification of erlotinib in 50 mL of samples of human serum. Anti-erlotinib serum was obtained by immunizing mice with an antigen conjugated with bovine serum albumin and 3,4-bis(2-methoxyethoxy)benzoic acid using the N-succinimidyl ester method. Enzyme labeling of erlotinib with horseradish peroxidase was similarly performed using 3,4-bis(2-methoxyethoxy)benzoic acid. A simple competitive ELISA for erlotinib was developed using the principle of direct competition between erlotinib and the enzyme marker for anti-erlotinib antibody, which had been immobilized on the plastic surface of a microtiter plate. Serum erlotinib concentrations lower than 40 ng/mL were reproducibly measurable using the ELISA. This ELISA was specific to erlotinib and showed very slight cross-reactivity(6.7%) with a major metabolite, O-desmethyl erlotinib. Using this assay, drug levels were easily measured in the blood of mice after oral administration of erlotinib at a single dose of 30 mg/kg. ELISA should be used as a valuable tool for therapeutic drug monitoring and in pharmacokinetic studies of erlotinib.
基金the grants from the Ministry of Sciences and Technology of China, No. 2006AA02A408, 2008ZX09312-014
文摘A total of 66 samples (from 27 cases with neuromyelitis optica, 26 cases with multiple sclerosis, aa 13 cases with optic neuritis) were tested for aquaporin-4 antibody by a cell-based immunofluorescence assay and an enzyme-linked immunosorbent assay. The sensitivities and specificities of the two assays were similar. We further analyzed an additional 68 patients and 93 healthy controls using the enzyme-linked immunosorbent assay. A Kappa test showed good consistency between the two methods in terms of detection of anti-aquaporin-4 antibody in the se of neuromyelitis optica patients. No significant correlations were identified with onset age or disea duration, suggesting that aquaporin-4 antibody is a good marker for neuromyelitis optica. The enzyme-linked immunosorbent assay can be used for quantifying aquaporin-4 antibody concentrations and may be useful to dynamically monitor changes in the levels of aquaporin-4 antibody during disease duration.
文摘During the course of study, we found that both poly (N-isopropylacrylamide ) (PNIP) and PNIP-Ab (enzyme-labelled antibody)could be adhere tightly to a cellulose acetale-nitrate membrane, and that the retention of PNIP-Ab on the membrane increased over 30-fold when compared with the unconjugated Ab.Thus we used this characteristic to develop a novel immunoassay method-polymer enzyme linked immunoassay method: homogeneous antigen-antibody reaction and heterogeneous separation process. When applied for detection of human serum HBsAg, this immunoassay system can detect as little as 1 ng/ml of human serum HBsAg.
文摘The simple rapid and sensitive enzyme-linked immunosorbent assay (ELISA) methods, di-rect and indirect ELISA, for quantitation of ochratoxin A in cereal had been developed by theutilization of monoclonal antibody on immunomicroplate. Direct FLIAS was found to be less timeconsuming than indirect ELISA. For direct FLISA, recovery of 1 -500 ppb OA added to wheat was78.9-100.0% and rice was 88.9- 120.0%. For indirect EI.IAS, recovery of 1-500 ppb OA addedto wheat was 79.0- 110.0% and rice was 82.0 120.0%. The minimal detection level for OA was Ippb. Analyses of 31 samples that caused humanintoxicant for OA showed that the ELISA resultsagreed wtll with those obtained by thin-layer chromatogrdphy.
文摘Afatinib is an oral tyrosine kinase inhibitor(TKI) approved for treating advanced non-small cell lung cancer. It is necessary to develop a simple quantification method for TKIs in order to facilitate therapeutic drug monitoring(TDM) in clinical settings. This study sought to develop a simple and sensitive competitive enzyme-linked immunosorbent assay(ELISA) to quantify afatinib in plasma for routine pharmacokinetic applications. An anti-afatinib antibody was obtained using(S)-N-4-(3-chloro-4-fluorophenyl)-7-(tetrahydrofuran-3-yloxy)-quinazoline-4,6-diamine(CTQD), which has the same substructure as afatinib, as a hapten. Enzyme labeling of afatinib with horseradish peroxidase was similarly performed using CTQD. A simple competitive ELISA for afatinib was developed based on the principle of direct competition between afatinib and the enzyme marker for the anti-afatinib antibody, which had been immobilized on the plastic surface of a microtiter plate. Plasma afatinib concentrations below the limit of quantification of 30 pg/mL were reproducibly measurable. Also, the values of plasma afatinib levels measured from 20 patients were comparable with those measured by high-performance liquid chromatography, and there was a strong correlation between the values determined by both methods(Y=0.976 X – 0.207, r=0.975). As indicated by its specificity and sensitivity, this newly developed ELISA for afatinib is an important tool for TDM and studies of the pharmacokinetics of afatinib.
文摘Mycoplasma mycoides subsp mycoides SC (MmmSC) is the etiological agent of contagious bovine pleuropneumonia (CBPP). The lipoprotein LppQ encoded by lppQ gene is specific to MmmSC and is found in the type strain and in field strains isolated in Europe, Africa, and Australia, as well as in vaccine strains. No serological cross-reactions were observed with the related mycoplasmas of the Mycoplasma mycoides cluster. The N-terminal domain of the mature lipoprotein LppQ is hydrophilic, and it induces a strong, specific, early, and persistent immune response in naturally and experimentally infected animals. Mycoplasma-specific TGA (Trp) codons are utilized as stop codons in most other organisms. The lppQ N-terminal fragment from MmmSC HVRI X strain, the Chinese strain for CF antigen production, was mutated with one-step overlapping extension PCR. Sequence analysis confirmed the successful mutation from A to G in codon 198 in the lppQ gene. The fragment containing the mutation site was subcloned into the pET32a expression vector. The recombinant protein with molecular weight of 42 kDa was purified using the Ni-NTA His.Bind purification kit, with a purity of up to 95%. Western blot indicated that the standard positive serum of CBPP could react with the recombinant protein. The purified protein was diluted to 0.35 μg mL^-1, and coated to microtiter enzyme-linked immunosorbent assay (ELISA) plates. Indirect ELISA reaction conditions were optimized. The value of P/N was determined to be 4.8 (0.934/0.193), the sensitivity to be 95.8% (46/48), and the specificity to be 98.9% (161/163). 3 817 cattle serum samples from three different provinces were detected by the indirect ELISA and CFT. The Kappa value is 0.63, which is middle or high agreement between the two methods.
文摘Anti-bungarotoxin anti-serum,which has the internal image of nicotinicacetylcholine receptor,was used as a tool to measure anti-idiotypic antibodies toantibodies to Iigand of nicotinic acctylcholine receptor in scra from 81 patients withmyasthenia gravis.Enzyme-linked immunosorbcnt assay was adopted.Thc positive ratewas 46.9%(38/81).The specific cross inhibitory test with nicotinic acetylcholinereceptor was positive.Anti-idiotype antibodies to antibodies to ligand of nicotinicacetylcholine receptor in sera of different types of myasthenia gravis patients classified ac-cording to modified Osserman’s standard and myasthenia gravis patients with or withoutthymoma were comparcd in this study and the role of anti-idiotype antibodies toantibodies to Iigand of nicotinic acctylcholinc receptor in the immunity of myasthcniagravis and the possibility of thcrapeutic use of anti-idiotype antibodies arc discussed.
文摘In thes paper the authors used the Horseradish peroxidase labelledstaphylococcal protein A(HRP—SPA)in ELISA,for the detection of Clo-norchis sinensis infection.Serum tests were made on 116 confirmed cases ofclonorchiasis,103(88.8%)of them showed positive,while only 6(4.4%)werepositive among 138 healthy people.Samples were collected on filter paperstrips,111(95.7%)cases were positive among 116 comfirmed cases tested,but only 2(1.5%)were positive out of 138 healthy persons.The resultswere similar to those obtained by sheep antihuman IgG.Animal experimentalso showed that the SPA—ELISA can be used for the diagnosis ofclonorchiasis.In an endemic area,stool egg positive rate was 8.8%(62/703).whenchecked with SPA—ELISA,the rate of conformity in both filter paperstrips and stool examinations was 90.3(56/62).Among 641 serum testsfrom individuals negative in stool examinations,only 35(5.5%)reactedpositively.The authors suggested—that SPA—ELISA with soluble Clo-norchis antigens could be used in a large scale seroepidemiological surveyin endemic areas.
文摘Enzyme-linked immunosorbent assay (ELISA) is the most widely used method for measuring a single cytokine. Recent developments in cytokine quantification such as multiple arrays measure multiple cytokines simultaneously. Although good correlations between ELISA and multiplex methods have been observed, side by side comparisons are limited. In the present study we hypothesized that ELISA and Luminex techniques are comparable in detecting cytokines in culture medium when pulmonary artery smooth muscle cells (PASMC) are exposed to stress. Primary human PASMC were cultured in modular chambers and exposed to 21% FiO2 and peak inspiratory and positive end expiratory pressure of 24 and 8 cmH2O respectively, and 95% FiO2. At 24 hours, culture medium was collected and assayed for interleukin-6 (IL-6) and IL-8 by quantitative ELISA and by Human Cytokine 25-Plex Panel using a Luminex 200 analyzer. A comparative analysis of agreement between our ELISA and Luminex data was detailed for control and stress conditions using the Bland-Altman plot analysis. Each assay resulted in comparable increased (p < 0.001) levels of IL-6 and IL-8 as compared to control in response to oxidative and biophysical stress. The Bland-Altman analysis demonstrated that 95% of the differences between ELISA and Luminex values were within ±1.96 SD from the mean difference indicated by the 95% limits of agreement for the measurements of IL-6 and IL-8. There was no systematic bias as a function of inflammation level. We conclude that in this cell culture model, ELISA and Luminex are comparable in detecting the levels of IL-6 and IL-8 in the culture medium. If measurements of multiple cytokines are demanded and the amount of sample is limited, Luminex multi-analyte profiling technology is accurate and sensitive.
基金supported by the National Basic Research Program of China (973 Program,no. 2007CB714507)National Nature Science Foundation of China (no. 90813015)
文摘A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELISA).A systematic comparison between the MmPs-CLEIA and colorimetric ELISA concluded that the MPs-CLEIA exhibited fewer dosages of immunoreagents,less total assay time,and better linearity,recovery,precision,sensitivity and validity.AFP was detected in forty human serum samples by the proposed MPs-CLEIA and ELISA,and the results were compared with commercial electrochemiluminescence immunoassay (ECLIA) kit.The correlation coefficient between MPs-CLEIA and ELISA was obtained with R 2 0.6703;however,the correlation between MPs-CLEIA and ECLIA (R 2 0.9582) was obviously better than that between colorimetric ELISA and ECLIA (R 2 0.6866).