The equivalent simplification of large wind farms is essential for evaluating the safety of power systems.However,sub-synchronous oscillations can significantly affect the stability of power systems.Although detailed ...The equivalent simplification of large wind farms is essential for evaluating the safety of power systems.However,sub-synchronous oscillations can significantly affect the stability of power systems.Although detailed mathematical models of wind farms can help accurately analyze the oscillation mechanism,the solution process is complicated and may lead to problems such as the“dimensional disaster.”Therefore,this paper proposes a sub-synchronous frequency domain-equivalent modeling method for wind farms based on the nature of the equivalent resistance of the rotor,in order to analyze sub-synchronous oscillations accurately.To this end,Matlab/Simulink is used to simulate a detailed model,a single-unit model,and an equivalent model,considering a wind farm as an example.A simulation analysis is then performed under the sub-synchronous frequency to prove that the model is effective and that the wind farm equivalence model method is valid.展开更多
An improved single-π equivalent circuit model for on-chip inductors in the GaAs process is presented in this paper. Considering high order parasites, the model is established by comprising an improved skin effect bra...An improved single-π equivalent circuit model for on-chip inductors in the GaAs process is presented in this paper. Considering high order parasites, the model is established by comprising an improved skin effect branch and a substrate lateral coupling branch. The parameter extraction is based on an improved characteristic function approach and vector fitting method. The model has better simulation than the previous work over the measured data of 2.5r and 4.5r on-chip inductors in the GaAs process.展开更多
Compared with non-gray model,equivalent gray model has equal calculation accuracy but much higher computing speed.To solve the existing problems of the equivalent gray method,sole ternary model was developed.In the mo...Compared with non-gray model,equivalent gray model has equal calculation accuracy but much higher computing speed.To solve the existing problems of the equivalent gray method,sole ternary model was developed.In the model,coupling solving process of energy balance equations is omitted and the model zone is real closed.Meanwhile,the full furnace temperature and heat flow calculations are avoided,which makes it easier to find the relationship between the equivalent gray gas radiation characteristic parameter and the initial conditions.The radiation characteristic parameter was calculated with different temperature combinations,different model zone sizes and different partial pressures of absorbent gas.The results show the similar variations in the absorption coefficient and emissivity for the equivalent gray model,which both decrease with the increase of the gas temperature and the surface temperature(especially the former one)as well as the model zone size while increase with the increase of the partial pressure of absorbent gas.展开更多
基金supported by the National Key R&D Program of China“Response-driven intelligent enhanced analysis and control for bulk power system stability”(No.2021YFB2400800)。
文摘The equivalent simplification of large wind farms is essential for evaluating the safety of power systems.However,sub-synchronous oscillations can significantly affect the stability of power systems.Although detailed mathematical models of wind farms can help accurately analyze the oscillation mechanism,the solution process is complicated and may lead to problems such as the“dimensional disaster.”Therefore,this paper proposes a sub-synchronous frequency domain-equivalent modeling method for wind farms based on the nature of the equivalent resistance of the rotor,in order to analyze sub-synchronous oscillations accurately.To this end,Matlab/Simulink is used to simulate a detailed model,a single-unit model,and an equivalent model,considering a wind farm as an example.A simulation analysis is then performed under the sub-synchronous frequency to prove that the model is effective and that the wind farm equivalence model method is valid.
基金Project supported by the National Natural Science Foundation of China(No.61674036)
文摘An improved single-π equivalent circuit model for on-chip inductors in the GaAs process is presented in this paper. Considering high order parasites, the model is established by comprising an improved skin effect branch and a substrate lateral coupling branch. The parameter extraction is based on an improved characteristic function approach and vector fitting method. The model has better simulation than the previous work over the measured data of 2.5r and 4.5r on-chip inductors in the GaAs process.
基金Sponsored by National Science and Technology Support Plan of China(2011AA060104)
文摘Compared with non-gray model,equivalent gray model has equal calculation accuracy but much higher computing speed.To solve the existing problems of the equivalent gray method,sole ternary model was developed.In the model,coupling solving process of energy balance equations is omitted and the model zone is real closed.Meanwhile,the full furnace temperature and heat flow calculations are avoided,which makes it easier to find the relationship between the equivalent gray gas radiation characteristic parameter and the initial conditions.The radiation characteristic parameter was calculated with different temperature combinations,different model zone sizes and different partial pressures of absorbent gas.The results show the similar variations in the absorption coefficient and emissivity for the equivalent gray model,which both decrease with the increase of the gas temperature and the surface temperature(especially the former one)as well as the model zone size while increase with the increase of the partial pressure of absorbent gas.