The design scheme for a new kind of long-distance intelligent watt-hour meter is presented. In the system, the control computer communicates with the bank's host computer by the X. 25 network; the built-in embeded se...The design scheme for a new kind of long-distance intelligent watt-hour meter is presented. In the system, the control computer communicates with the bank's host computer by the X. 25 network; the built-in embeded secure access module (ESAM) can verify data by commutation with the intelligent nodes that enhance the security of the data. IC TSS721 is adopted to collect data remotely, and the CPU IC card is used to ensure the the bargaining security and reliability. In addition, the software of the system is introduced.展开更多
There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R4...There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R46 contents to provide a reference of the integrity comparison between the accuracy system and technical parameter system. The comparison result shows that the watt-hour meter accuracy technical indicators system of OIML R46 is more integrated. First reason is that it determines all the accuracy (basic error) defining rules just by using the technical parameter I efficiently; secondly, it can solve the contradiction that no error regulation of the range from starting current to minimum current in the process of providing, handing over and checking watt-hour meter products' qualities efficiently. Please pay close attention to the R46 official version which will be released soon, as it is still in the Committee Draft (CD6) stage currently.展开更多
由于DCS控制器中电表传感器在计量检测过程中,传统的B-MAC-DCS协议能耗和丢包率较高,无法缓解汇聚节点的漏斗效应,导致在远程抄表过程中传感器计量误差增大。提出一种机械电表接触传感器计量误差检测方法。采用小波基函数对DCS控制器中...由于DCS控制器中电表传感器在计量检测过程中,传统的B-MAC-DCS协议能耗和丢包率较高,无法缓解汇聚节点的漏斗效应,导致在远程抄表过程中传感器计量误差增大。提出一种机械电表接触传感器计量误差检测方法。采用小波基函数对DCS控制器中的接触传感器计量数据抗干扰处理,并通过动态选取阈值的方法,对经过小波变换后的数据去除噪声。使用低功耗自适应集簇分层型(low energy adaptive clustering hierarchy,LEACH)协议分簇代替传统的B-MAC协议;根据簇内监测值,引入阈值分析方法获取传感器计量指标,并将其作为判定依据进行误差检测,根据计量指标的变化情况判断是否存在计量误差。实验结果表明,所提方法可以准确且有效检测出机械电表接触传感器计量误差,解决DCS中机械电表的运行隐患问题。展开更多
文摘The design scheme for a new kind of long-distance intelligent watt-hour meter is presented. In the system, the control computer communicates with the bank's host computer by the X. 25 network; the built-in embeded secure access module (ESAM) can verify data by commutation with the intelligent nodes that enhance the security of the data. IC TSS721 is adopted to collect data remotely, and the CPU IC card is used to ensure the the bargaining security and reliability. In addition, the software of the system is introduced.
文摘There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R46 contents to provide a reference of the integrity comparison between the accuracy system and technical parameter system. The comparison result shows that the watt-hour meter accuracy technical indicators system of OIML R46 is more integrated. First reason is that it determines all the accuracy (basic error) defining rules just by using the technical parameter I efficiently; secondly, it can solve the contradiction that no error regulation of the range from starting current to minimum current in the process of providing, handing over and checking watt-hour meter products' qualities efficiently. Please pay close attention to the R46 official version which will be released soon, as it is still in the Committee Draft (CD6) stage currently.
文摘由于DCS控制器中电表传感器在计量检测过程中,传统的B-MAC-DCS协议能耗和丢包率较高,无法缓解汇聚节点的漏斗效应,导致在远程抄表过程中传感器计量误差增大。提出一种机械电表接触传感器计量误差检测方法。采用小波基函数对DCS控制器中的接触传感器计量数据抗干扰处理,并通过动态选取阈值的方法,对经过小波变换后的数据去除噪声。使用低功耗自适应集簇分层型(low energy adaptive clustering hierarchy,LEACH)协议分簇代替传统的B-MAC协议;根据簇内监测值,引入阈值分析方法获取传感器计量指标,并将其作为判定依据进行误差检测,根据计量指标的变化情况判断是否存在计量误差。实验结果表明,所提方法可以准确且有效检测出机械电表接触传感器计量误差,解决DCS中机械电表的运行隐患问题。