期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Thermo-economic analysis of the performance of the combined system with evacuated tube collectors
1
作者 Ghassan Fadhil Smaisim Salema K.Hadrawi +2 位作者 Azher M.Abed Hasan Sh.Majdi Ali Shamel 《Clean Energy》 EI CSCD 2023年第2期242-252,共11页
Using combined cooling,heat and power systems can be an appropriate substitute for preventing emissions of pollutants and excessive consumption of fossil fuels.Utilizing renewable energy in these systems as a source o... Using combined cooling,heat and power systems can be an appropriate substitute for preventing emissions of pollutants and excessive consumption of fossil fuels.Utilizing renewable energy in these systems as a source of power generation can be an appropriate substitute for fossil-fuel-based systems.Therefore,in this paper,cogeneration cooling,heat and power systems based on gas-fired internal combustion engines with a solar-thermal system with evacuated tube collectors have been modelled and thermo-economic analysis has been done to compare fossil-fuel-based systems.The required rate of heat to supply the hot water is 50 kW.In the studied system,the internal combustion engine produces electrical energy.Then,the solar-thermal system with evacuated tube collectors and the gas-burning generator provide the thermal energy required by the studied building and the primary stimulus of the absorption chiller for cooling.In this study,two different scenarios are conducted in states considering simultaneous production systems and regardless of this environmental and thermo-economic analysis system.The results showed that the efficiency of the studied system was 60% in summer and 56% in winter. 展开更多
关键词 combined cooling heat and power thermo-economic analysis evacuated tube collectors environmental analysis solar-thermal energy
原文传递
Experiment and numerical simulation on flow and heat transfer in all-glass evacuated tube solar collectors
2
作者 张涛 韩吉田 +2 位作者 陈常念 孔令健 刘洋 《Journal of Southeast University(English Edition)》 EI CAS 2016年第4期489-495,共7页
The experimental study of natural convection in allglass evacuated tube solar collectors is performed through the experimental platform of the solar-assisted fuel cell system.The experimental facility includes solar c... The experimental study of natural convection in allglass evacuated tube solar collectors is performed through the experimental platform of the solar-assisted fuel cell system.The experimental facility includes solar collectors with different length and diameter tubes, different coating materials, and with / without guide plates, respectively. Threedimensional mathematical models on natural and forced convections in the solar collectors are established and the experimental data is validated by field synergy and entransy principles. The results of natural convection show that the water temperature increases and thermal efficiency decreases gradually with the evacuated tube length. The thermal efficiency increases when absorption rates increase from 0. 95 to 1. 0 and emission rates decrease from 0. 16 to 0. 06. The thermal efficiency of solar collectors is increased after being equipped with the guide plate, which is attributed to the disappearance of the mixed flowand the enhancement of the heat transfer at the bottom of the evacuated tube. The results of forced convertion indicate that the Reynolds, Nusselt and entransy increments of the horizontal double collectors are higher than those of the vertical single collector while the entransy dissipation is lower than that of the vertical single collector. It is concluded that the solar collectors with guide plates are suitable for natural convection while the double horizontal collectors are suitable for forced convection in the thermal field of solar-assisted fuel cell systems with lowand medium temperatures. 展开更多
关键词 all-glass evacuated tube solar collectors the solar-assisted fuel cells field synergy principle entransy dissipation
下载PDF
Developments of solar collectors in China
3
作者 Yin Zhiqiang 《Engineering Sciences》 EI 2009年第2期80-85,共6页
China has abundant solar energy resource. Solar thermal collectors, particularly all-glass evacuated tubular collectors, have been studied and developed for 30 years, and solar thermal industry has developed rapidly f... China has abundant solar energy resource. Solar thermal collectors, particularly all-glass evacuated tubular collectors, have been studied and developed for 30 years, and solar thermal industry has developed rapidly for 15 years. There are various solar thermal systems, with an operation area of around 108 million m2 in 2007. These systems mainly provide domestic hot water, but some other applications are under extensive study and development as well. 展开更多
关键词 solar collector domestic hot water flat plate collector all-glass evacuated collector tube all-glass evacuated tube collector glass-metal evacuated tube collector
下载PDF
Performance of U-tube Solar Water Heaters Facing Different Directions
4
作者 Ong Kok-Seng Tong Wei-Li David Cheong 《Journal of Energy and Power Engineering》 2013年第9期1729-1734,共6页
System performance of solar water heaters depends upon collector and storage tank designs, solar radiation intensity and ambient temperature, amongst others. Evacuated glass tube collectors with U-tubes inside are les... System performance of solar water heaters depends upon collector and storage tank designs, solar radiation intensity and ambient temperature, amongst others. Evacuated glass tube collectors with U-tubes inside are less prone to leakages than the all-glass or the heat pipe types. U-tube solar water heaters suspended on walls and balconies could help overcome present day roof space restriction and increasing apartment-style housing. As such, their performance would depend upon its orientation when mounted in a vertical position. This paper reports the results of outdoor tests conducted on natural convection U-tube solar water heaters oriented towards different directions. Long and short term test procedures were employed to allow us to compare their performances as if they were tested simultaneously side-by-side. 展开更多
关键词 Solar water heater evacuated glass tube U-tube collector natural convection long and short term tests directional effects.
下载PDF
Laminar Natural Convective Heat Transfer in theEnclosed Evacuated Collector Tube with East-West Symmetric Heat Input
5
作者 ZhangHeng-Yun GeXin-Shi 《Journal of Thermal Science》 SCIE EI CAS CSCD 1997年第1期35-43,共9页
Heat transfer in the evacuated collector tube is a three-dimensional laminar natural convection prob-lem driven by buoyancy. Because of its complexity, no effective theoretical model is available despiteof limited exp... Heat transfer in the evacuated collector tube is a three-dimensional laminar natural convection prob-lem driven by buoyancy. Because of its complexity, no effective theoretical model is available despiteof limited experimental work which is confined to one aspect- The present work aims to depict theconvective heat transfer inside a tweended inclined tube with East-West symmetric heat input us-ing numerical methods. Based on reasonable assumptions, governing equations of the inside fluid areestabllshed. The corresponding discretizated equations are solved by employing numerical methods.The calculated results are displayed for velocity and temperature profiles on different cross-sectionalplanes, which present the flow pattern characterized by upflow and dowallow along the axial direc-tion and adherent flow along the peripheral direction, and the heat transfer process from the wall tothe center. Furthermore, the transient Nusselt number and average temperature level are shown anddiscussed. Finally, the parametric effects of the tube radius and the heat input on the flow and heattransfer are also given. 展开更多
关键词 natural convection evacuated collector tube E-W symmetric heat input boundary singularity numerical simulation
原文传递
Modelling, Transient Simulation and Economic Analysis of Solar Thermal Based Air Conditioning System in Gujarat
6
作者 Ganesh Utham Sagarkumar M. Agravat +1 位作者 Bela Jani Jignasha Bhutka 《Smart Grid and Renewable Energy》 2016年第8期233-246,共14页
Commercial building sector accounts for 8% of the total electricity consumption in India. Cooling activities (HVAC) in commercial buildings consume 55% of the total energy utilized. Consequently, CO<sub>2</su... Commercial building sector accounts for 8% of the total electricity consumption in India. Cooling activities (HVAC) in commercial buildings consume 55% of the total energy utilized. Consequently, CO<sub>2</sub> emissions from conventional buildings in India were estimated to be 98 metric tonnes of CO<sub>2</sub> per million ft<sup>2</sup> in 2014. Solar thermal air conditioning can be the solution to these demands and can contribute to about 15% to 20% of India’s total oil consumption thereby reducing the dependence on fossil fuels. Hence, the main objective of the work is to model and simulate a solar absorption cooling system for GERMI office building located in Gandhinagar, Gujarat, India, using the transient simulation software ‘TRNSYS’. Cooling load estimation and comfort conditions required for the building were determined based on ASHRAE standards. Evacuated tube collectors were selected because of its market availability, ease of manufacturing and proven technology. Single effect absorption chiller was used because of its commercial availability. The effects of storage tank volume, collector area and collector slope were also investigated for parametric optimization. The results of the simulation and parametric analysis are analyzed and presented in the paper. 展开更多
关键词 Solar Air Conditioning evacuated tube collectors (ETC) TRNSYS Simulation Single Effect Absorption Chiller Parametric Analysis INDIA
下载PDF
A Mechanical and Experimental Study on the Heat Loss of Solar Evacuated Tube 被引量:1
7
作者 赵惠忠 刘震炎 +3 位作者 张敏 黄晨 王丽慧 邹志军 《Journal of Shanghai Jiaotong university(Science)》 EI 2009年第1期52-57,共6页
The experimental system of heat loss of all-glass evacuated solar collector tubes(evacuated tube) is firstly designed and constructed,which uses electric heater as thermal resource.The equilibrium temperatures are les... The experimental system of heat loss of all-glass evacuated solar collector tubes(evacuated tube) is firstly designed and constructed,which uses electric heater as thermal resource.The equilibrium temperatures are less than±1℃during the test.and the temperature differences of up/middle/low node in the tube are less than 1℃,3℃,and 7℃respectively.The heat loss of evacuated tube increases about 2.7%with vacuum state of 0.01--1 mPa,and it has the best performance at tube temperature of 20--280℃.The invalidation tube(>200 mPa) has the biggest heat loss that increases linearly with the tube temperature.The evacuated tubes with the vacuum of 0.01-1 mPa are suitable for most solar adsorption refrigeration. 展开更多
关键词 all-glass evacuated solar collector tube adsorption refrigeration vacuum state heat loss equilibrium temperature
原文传递
Solar Heater Technologies Selection Using Multi-criteria Analysis
8
作者 Mohsine Bouya Badr Abou El Majd +1 位作者 Merieme Agdid Abdellatif Ben Abdellah 《Journal of Energy and Power Engineering》 2015年第4期393-398,共6页
Regarding sun's potential in Middle East and North Africa zone and particularly in Morocco, we focus our work on the development of the knowledge and information concerning the solar heaters for domestic applications... Regarding sun's potential in Middle East and North Africa zone and particularly in Morocco, we focus our work on the development of the knowledge and information concerning the solar heaters for domestic applications, in order to help the industrial and the consumer to select an adaptive technology. As a result, a Moroccan mapping of solar water heating systems is presented in this work. This mapping concerns two technologies commonly used: the FPC (flat plate collectors) and the ETC (evacuated tubes ones). It is based on three criteria: firstly, the efficiency of the STC (solar thermal collectors); secondly, the economic aspect and at last, the reliability requirements. Based on these information, the multi-criteria outranking methodology PROMETHEE (preference ranking organization method for the enrichment evaluations) allows us to define an adequate solar heater technology linked with the climatic zoning of Morocco. 展开更多
关键词 MAPPING solar water heating flat plate collector evacuated tubes collectors PROMETHEE.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部