期刊文献+
共找到1,784篇文章
< 1 2 90 >
每页显示 20 50 100
Research status and development trends of evaporative cooling air-conditioning technology in data centers 被引量:6
1
作者 Junjie Chu Xiang Huang 《Energy and Built Environment》 2023年第1期86-110,共25页
This paper systematically describes the technical principles,evaluation indicators,system forms and research progress of air-side evaporative cooling air conditioning systems,water-side evaporative cooling air conditi... This paper systematically describes the technical principles,evaluation indicators,system forms and research progress of air-side evaporative cooling air conditioning systems,water-side evaporative cooling air conditioning systems and freon-side evaporative cold coagulation heat air conditioning systems of Data center.In order to reduce the energy consumption of the refrigeration and air-conditioning system in the Data center,the applica-tion conditions and scenarios of the different forms of evaporative cooling air-conditioning systems should be considered comprehensively.Therefore,it is very important that the renewable energy-dry air can be used to the greatest extent.These efforts would contribute to China’s 2030"Carbon Peak"and 2060"Carbon Neutral." 展开更多
关键词 Data center evaporative cooling Air-side Water-side Freon-side
原文传递
Evaporative Cooling Applied in Thermal Power Plants:A Review of the State-ofthe-Art and Typical Case Studies 被引量:1
2
作者 Tiantian Liu Huimin Pang +7 位作者 Suoying He Bin Zhao Zhiyu Zhang Jucheng Wang Zhilan Liu Xiang Huang Yuetao Shi Ming Gao 《Fluid Dynamics & Materials Processing》 EI 2023年第9期2229-2265,共37页
A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-coo... A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-cooled systems,gas turbine inlet cooling,wet cooling towers,and hybrid cooling towers with a crosswind effect.Some effort is provided to describe the advantages related to direct evaporative cooling when it is applied in thermal power plants and illustrate the research gaps,which have not been filled yet.In particular,typical case studies are intentionally used to compare the cooling performances when direct evaporative cooling is implemented in different types of cooling towers,including the natural draft wet cooling tower(NDWCT)and the pre-cooled natural draft dry cooling tower(NDDCT).It is shown that the NDWCT provides the best cooling performance in terms of power station cooling,followed by the pre-cooled NDDCT,and the NDDCT;moreover,the evaporative pre-cooling is able to enhance the cooling performance of NDDCT.Besides,on a yearly basis,better NDDCT cooling performances can be obtained by means of a spray-based pre-cooling approach with respect to wet media pre-cooling.Therefore,the use of nozzle spray is suggested for improvement in the performance of indirect/direct air-cooling systems with controlled water consumption. 展开更多
关键词 Direct evaporative cooling cooling tower cooling performance wet media nozzle spray thermal power plants
下载PDF
Experimental Study on the Thermal Performances of a Tube-Type Indirect Evaporative Cooler
3
作者 Tiezhu Sun Huan Sun +2 位作者 Tingzheng Tang Yongcheng Yan Peixuan Li 《Fluid Dynamics & Materials Processing》 EI 2023年第10期2519-2531,共13页
The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need... The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need to be addressed to make this technology more reliable and easy to implement.This experimental study deals with the performances of a tube-type indirect evaporative cooler based on an aluminum tube with a 10 mm diameter.In particular,the required tests were carried out considering a range of dry-bulb temperatures between 16℃ and 18℃ and a temperature difference between the wet-bulb and dry-bulb temperature of 2℃∼4℃.The integrated convective heat transfer coefficient inside the tube in the drenching condition has been found to lie in the range between 36.10 and 437.4(W/(m^(2)⋅K)). 展开更多
关键词 Tubular indirect evaporative cooler integrated convection heat transfer coefficient evaporative cooling thermal engineering calculation energy saving
下载PDF
Experimental Study of Air Conditioning Unit of Evaporative Cooling Assisted Mechanical Refrigeration 被引量:3
4
作者 HUANG Xiang,XU Fang-cheng,WU Jun-mei(Xi’an polytechnic University,Xi’an,Shaanxi 710048,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期106-110,共5页
The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analy... The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analyzed.The test shows that making full use of the evaporative cooling "free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the energy efficiency ratio of the Unit(EER)is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the new wind ratio up to 50 percent,more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent. 展开更多
关键词 evaporative cooling mechanical REFRIGERATION air-conditioning unit EER
下载PDF
Stark-potential evaporative cooling of polar molecules in a novel optical-access opened electrostatic trap 被引量:1
5
作者 孙慧 王振霞 +3 位作者 王琴 李兴佳 刘建平 印建平 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第11期196-205,共10页
We propose a novel optical-access opened electrostatic trap to study the Stark-potential evaporative cooling of polar molecules by using two charged disk electrodes with a central hole of radius r0 = 1.5 mm, and deriv... We propose a novel optical-access opened electrostatic trap to study the Stark-potential evaporative cooling of polar molecules by using two charged disk electrodes with a central hole of radius r0 = 1.5 mm, and derive a set of new analytical equations to calculate the spatial distributions of the electrostatic field in the above charged-disk layout. Afterwards, we calculate the electric-field distributions of our electrostatic trap and the Stark potential for cold ND3 molecules, and analyze the dependences of both the electric field and the Stark potential on the geometric parameters of our charged-disk scheme, and find an optimal condition to form a desirable trap with the same trap depth in the x, y, and z directions. Also, we propose a desirable scheme to realize an efficient loading of cold polar molecules in the weak-field-seeking states, and investigate the dependences of the loading efficiency on both the initial forward velocity of the incident molecular beam and the loading time by Monte Carlo simulations. Our study shows that the maximal loading efficiency of our trap scheme can reach about 95%, and the corresponding temperature of the trapped cold molecules is about 28.8 inK. Finally, we study the Stark-potential evaporative cooling for cold polar molecules in our trap by the Monte Carlo method, and find that our simulated evaporative cooling results are consistent with our developed analytical model based on trapping-potential evaporative cooling. 展开更多
关键词 evaporative cooling electrostatic trap Monte Carlo simulations
下载PDF
A Mathematical Model of an Evaporative Cooling Pad Using Sintered Nigerian Clay 被引量:1
6
作者 Chukwuneke Jeremiah Lekwuwa Ajike Chinagorom Ogbu +1 位作者 Achebe Chinonso Hubert Okolie Paul Chukwulozie 《Journal of Minerals and Materials Characterization and Engineering》 2012年第11期1113-1120,共8页
Overtime, reduction in the amount of heat generated in engineering systems in operations have been of great concern and have continuously been under study. It is in line with the above that this research work develope... Overtime, reduction in the amount of heat generated in engineering systems in operations have been of great concern and have continuously been under study. It is in line with the above that this research work developed a mathematical model of an evaporative cooling pad using sintered Nigerian clay. A physical model of the evaporative cooling phenomenon was developed followed by the derivation of the governing equations describing the energy and mass transfer for the clay model from the laws of conservation of continuum mechanics. A set of reasonable and appropriate as-sumptions were imposed upon the physical model. Constitutive relationships were also developed for further analysis of the developed equations. The finite element model of numerical methods was used to analyse the energy transfer governing equations which resulted in the determination of the temperature of the exposed boundary surface at any given time, t2 after the commencement of the evaporative cooling processes. In this paper, it was found out that surface temperature differences could be as much as 6?C in the first cycle of evaporative cooling with the potential of further reduction. Further, an equation for the prediction of the effectiveness of an evaporative cooling system using clay modeled cooling pads was developed. The findings in this research work can be applied in the design, construction and maintenance of evaporative coolers used to dissipate waste heat when a large amount of natural water is not readily available or if for environmental and safety reasons the large water body can no longer absorb waste heat. 展开更多
关键词 evaporative cooling NIGERIAN CLAY Finite Difference Model Energy TRANSFER cooling PAD Moulded CLAY Material Heat TRANSFER Refrigeration Temperature
下载PDF
Collision of cold CaF molecules: Towards evaporative cooling
7
作者 顾跃凤 黄云霞 +1 位作者 李传亮 杨晓华 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第3期161-167,共7页
Long range intermolecular interaction potential surface of CaF(~2∑^+) was simulated by employing the MOLPRO program and using the RCCSD(T)/def2-TZVP theory. The predicted data were further fitted to obtain the collis... Long range intermolecular interaction potential surface of CaF(~2∑^+) was simulated by employing the MOLPRO program and using the RCCSD(T)/def2-TZVP theory. The predicted data were further fitted to obtain the collision crosssection. The elastic collision cross-section of CaF at the temperature around 2 mK is as high as 6.5 × 10^(-9) cm^2 and the collision rate is over 4.1 × 10~6 Hz. Additionally, we found that an orientation electric field will simplify the intermolecular interaction potential function from quaternary into ternary and the collision cross-section will be raised by about three orders. All-optical evaporative cooling of cold CaF is discussed in the conclusion. 展开更多
关键词 INTERMOLECULAR interaction potential energy surface COLD COLLISION evaporative cooling
下载PDF
Surface-induced evaporative cooling
8
作者 柯敏 颜波 +1 位作者 程锋 王育竹 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第10期4274-4280,共7页
The effects of surface-induced evaporative cooling on an atom chip are investigated. The evolutions of temperature, number and phase-space density of the atom cloud are measured when the atom cloud is brought close to... The effects of surface-induced evaporative cooling on an atom chip are investigated. The evolutions of temperature, number and phase-space density of the atom cloud are measured when the atom cloud is brought close to the surface. Rapid decrease of the temperature and number of the atoms is found when the atom-surface distance is 〈 100 ttm. A gain of about a factor of five on the phase-space density is obtained. It is found that the efficiency of the surface-induced evaporative cooling depends on the atom-surface distance and the shape of the evaporative trap. When the atoms are moved very close to the surface, severe heating is observed, which dominates when the holding time is 〉 8 ms. It is important that the surface-induced evaporative cooling offers novel possibilities for the realization of a continuous condensation, where a spatially varying evaporative cooling is required. 展开更多
关键词 atom chip atom-surface distance surface-induced evaporative cooling
下载PDF
Experimental investigation of evaporative cooling mixture of bosonic ^(87)Rb and fermionic ^(40)K atoms with microwave and radio frequency radiation
9
作者 王鹏军 熊德智 +1 位作者 付正坤 张靖 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第1期515-520,共6页
We investigate sympathetic cooling fermions 40K by evaporatively cooling bosonic 87Rb atoms in a magnetic trap with microwave and radio frequency induced evaporations in detail. The mixture of bosonic and fermionic at... We investigate sympathetic cooling fermions 40K by evaporatively cooling bosonic 87Rb atoms in a magnetic trap with microwave and radio frequency induced evaporations in detail. The mixture of bosonic and fermionic atoms is prepared in their polarized spin states IF = 9/2, mF = 9/2) for 40K and IF = 2, mF=2〉 for 87Rb, which is trapped in Quadrupole-Ioffe-Configuration trap. Comparing microwave with radio frequency evaporatively cooling bosonic STRb atoms with sympathetically cooling Fermi gas 40K, we find that the presence of rubidium atoms in the [2, 1} Zeeman states, which are generated in the evaporative process, gives rise to a significant loss of 40K due to inelastic collisions. Thus, the rubidium atoms populated in the [2, 1} Zeeman states should be removed in order to effectively perform sympathetically cooling 40K with the evaporatively cooled STRb atoms. 展开更多
关键词 microwave and radio frequency induced evaporation sympathetically cooling inelasticcollisions
下载PDF
Light-induced evaporative cooling in a magneto-optical trap
10
作者 马红玉 成华东 +1 位作者 王育竹 刘亮 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第11期4180-4183,共4页
This paper presents an experimental demonstration of light-induced evaporative cooling in a magneto-optical trap. An additional laser is used to interact with atoms at the edge of the atomic cloud in the trap. These a... This paper presents an experimental demonstration of light-induced evaporative cooling in a magneto-optical trap. An additional laser is used to interact with atoms at the edge of the atomic cloud in the trap. These atoms get an additional force and evaporated away from the trap by both the magnetic field and laser fields. The remaining atoms have lower kinetic energy and thus are cooled. It reports the measurements on the temperature and atomic number after the evaporative cooling with different parameters including the distance between the laser and the centre of the atomic cloud, the detuning, the intensity. The results show that the light-induced evaporative cooling is a way to generate an ultra-cold atom source. 展开更多
关键词 evaporative cooling magneto-optical trap
下载PDF
The Effects of Evaporative Cooling on Folliculogenesis and Ovarian Hormones during the Estrous Cycle of Dairy Holstein Cows during the Summer Months in Saudi Arabia
11
作者 Mohamed Jafar Al-Hassan 《Open Journal of Veterinary Medicine》 2018年第10期175-185,共11页
Heat stress is identified as a major cause of lower productive and reproductive performance in animal farming. This situation is more common in Saudi Arabia than in other countries because of extremely high ambient te... Heat stress is identified as a major cause of lower productive and reproductive performance in animal farming. This situation is more common in Saudi Arabia than in other countries because of extremely high ambient temperatures experienced during the summers. The evaporative cooling cow group had significantly increased serum E2 concentrations on days 7 and 14 - 19 of their estrous cycles, and significantly decreased serum P4 concentrations on days 7 - 18 of their estrous cycles. Evaporative cooling plus shade lowered ambient temperatures (41.80 ± 0.74 versus 47.40?C ± 0.84?C) have increased the relative humidity (0.33 ± 0.01 versus 0.24 ± 0.01) and decreased the temperature humidity index (80.24 ± 0.60 versus 84.77 ± 0.68) when compared with shade alone. However, cows under shade alone, compared to cows under evaporative cooling with shade, had a larger number of small (10.04 ± 0.54 versus 4.72 ± 0.58), medium (2.80 ± 0.21 versus 1.79 ± 0.17), and large follicles (6.82 ± 0.28 versus 5.66 ± 0.22). These results demonstrated that while evaporative cooling had positive effects on dairy cows in this experiment, changes could have been more profound, if installations of curtains and fans were implemented, which might need further investigation. 展开更多
关键词 evaporative cooling FOLLICULOGENESIS Heat Stress E2 and P4
下载PDF
Analysis of Solar Direct-Driven Organic Rankine Cycle Powered Vapor Compression Cooling System Combined with Electric Motor for Office Building Air-Conditioning
12
作者 Xiang Xiao Wei Zhao +4 位作者 Wei Wang Wei Zhang Xianbiao Bu Lingbao Wang Huashan Li 《Energy Engineering》 EI 2021年第1期89-101,共13页
Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electri... Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electric motor is proposed to ensure smooth operation under the conditions that solar radiation is unstable and discontinuous,and an office building located in Guangzhou,China is selected as a case study.The results show that beam solar radiation and generation temperature have considerable effects on the system performance.There is an optimal generation temperature at which the system achieves optimum performance.Also,as a key indicator,the cooling power per square meter collector should be considered in the hybrid solar cooling system in design process.Compared to the vapor compression cooling system,the hybrid cooling system can save almost 68.23%of electricity consumption. 展开更多
关键词 Solar cooling organic Rankine cycle vapor compression cycle hybrid solar cooling system office building air-conditioning
下载PDF
Modeling and Simulation of Evaporative Cooling System in Controlled Environment Greenhouse
13
作者 Faten Hosney Fahmy Hanaa Mohamed Farghally +1 位作者 Ninet Mohamed Ahmed A. A. Nafeh 《Smart Grid and Renewable Energy》 2012年第1期67-71,共5页
Greenhouses are used for the main purpose of improving the environmental conditions in which plants are grown. There are many parameters can affect the growing of plants inside greenhouse, such as air temperature and ... Greenhouses are used for the main purpose of improving the environmental conditions in which plants are grown. There are many parameters can affect the growing of plants inside greenhouse, such as air temperature and relative humidity. The adjustment of these parameters is achieved by selecting appropriate control actions. This work proposes a controlling technique for greenhouse indoor temperature and relative humidity. The proposed greenhouse cooling system temperature controller is designed to adjust the air volume flow rate in pad-fan cooling system to fix the greenhouse indoor temperature at 20?C and 70% relative humidity. The designed control technique is realized to ensure the required and continuous operation of the greenhouse. Moreover, this work present, a complete mathematical modeling and simulation of cooling system is introduced. In addition, a computer model based on MATLAB SIMULINK software has been used to predict the temperature and relative humidity profiles inside the greenhouse. The results are realized the requirements of the greenhouse cooling system environment. 展开更多
关键词 Pad-Fan evaporative cooling System PI CONTROLLER and GREENHOUSE
下载PDF
Observation of Atomic Dynamic Behaviors in the Evaporative Cooling by In-Situ Imaging the Plugged Hole of Ultracold Atoms
14
作者 高天佑 张东方 +2 位作者 孔令冉 李睿宗 江开军 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第8期58-61,共4页
We experimentally observe the dynamic evolution of atoms in the evaporative cooling, by in-situ imaging the plugged hole of ultracold atoms. Ultracold rubidium atoms confined in a magnetic trap are plugged using a blu... We experimentally observe the dynamic evolution of atoms in the evaporative cooling, by in-situ imaging the plugged hole of ultracold atoms. Ultracold rubidium atoms confined in a magnetic trap are plugged using a blue-detuned laser beam with a waist of 20 m at a wavelength of 767 nm. We probe the variation of the atomic temperature and width versus the radio frequency in the evaporative cooling. Both the behaviors are in good agreement with the calculation of the trapping potential dressed by the rf signal above the threshold temperature,while deviating from the calculation near the phase transition. To accurately obtain the atomic width, we use the plugged hole as the reference to optimize the optical imaging system by precisely minimizing the artificial structures due to the defocus effect. 展开更多
关键词 Observation of Atomic Dynamic Behaviors in the evaporative cooling by In-Situ Imaging the Plugged Hole of Ultracold Atoms
下载PDF
Radiative-coupled evaporative cooling:Fundamentals,development,and applications
15
作者 Li Yu Yimou Huang +4 位作者 Weihong Li Changmin Shi Brian W.Sheldon Zhuo Chen Meijie Chen 《Nano Research Energy》 2024年第2期56-68,共13页
As global energy demand continues to rise and climate change accelerates,the need for sustainable and energy-efficient cooling solutions has reached a critical level.Conventional air conditioning systems heavily rely ... As global energy demand continues to rise and climate change accelerates,the need for sustainable and energy-efficient cooling solutions has reached a critical level.Conventional air conditioning systems heavily rely on energy-intensive mechanical cooling,which significantly contributes to both electricity demand and greenhouse gas emissions.Passive cooling strategies,particularly radiative cooling(RC)and evaporative cooling(EC),present an alternative approach by harnessing natural processes for temperature regulation.While standalone RC can be affected by weather conditions and EC relies on water availability,Radiative-coupled EC(REC)offers a versatile and sustainable cooling solution suitable for various applications.Here we summarize an overview of the theoretical foundations and mathematical models of REC,encompassing REC by bulk water(REC-BW),REC by perspiration(REC-P),and REC by sorbed water(REC-SW).Moreover,we explore a range of applications,spanning from industrial processes to personal thermal management,and examine the advantages and challenges associated with each REC approach.The significance of REC lies in its potential to revolutionize cooling technology,reduce energy consumption,and minimize the environmental impact.REC-BW can conserve water resources in industrial cooling processes,while REC-P offers innovative solutions for wearable electronics and textiles.REC-SW’s adaptability makes it suitable for food preservation and future potable cooling devices.By addressing the challenges posed by REC,including water consumption,textile design,and optimization of bilayer structures,we can unlock the transformative potential of REC and contribute to sustainable cooling technologies in a warming world. 展开更多
关键词 radiative cooling evaporative cooling passive cooling thermal radiation mass transfer
原文传递
Studying the Role Played by Evaporative Cooler on the Performance of GE Gas Turbine Existed in Shuaiba North Electric Generator Power Plant
16
作者 O. R. AL-Hamdan A. A. Saker 《Energy and Power Engineering》 2013年第6期391-400,共10页
It’s well known that the performance of a gas turbine (efficiency, heat rate and power generated) is largely dependent on mass flow rate of air, inlet air temperature and turbine inlet temperature (TIT). As turbine i... It’s well known that the performance of a gas turbine (efficiency, heat rate and power generated) is largely dependent on mass flow rate of air, inlet air temperature and turbine inlet temperature (TIT). As turbine inlet temperature is dependent on quantity of burned fuel so that this factor is dropped out from this paper. It’s also known that gas turbines are constant volume machines i.e. at a given shaft speed they always move the same volume of air, but the power out-put of a turbine depends on the flow of mass through it. This is precisely the reason why on hot days, when air is less dense, power output falls off. A rise of one degree Centigrade temperature of inlet air decreases the power output by 1% and at the same time heat rate of the turbine also goes up. This is a matter of great concern to power producers. Many techniques have been developed to cool the inlet air to gas turbine. Some of these techniques to decrease the inlet air temperature are discussed here. The evaporative cooling technique is taken as a case study in this paper. A comparative studying is carried out between a unit using this technique and the same unit when the evaporative cooler is idle. The results advert to an increase in power output by 11.07% and a decrease in heat rate by approximately 4% when inlet air temperature drops from 50°C to 26°C. 展开更多
关键词 Gas TURBINE SHAFT Speed Power Output The evaporative cooling Technique
下载PDF
Applying Neural Network in Evaporative Cooler Performance Prediction
17
作者 强天伟 沈恒根 +1 位作者 黄翔 宣永梅 《Journal of Donghua University(English Edition)》 EI CAS 2007年第3期400-403,共4页
背繁殖(BP ) 神经网络被创造预言性能一直接成为蒸气的冷却(DEC ) 有 GLASdek 的空调填。关于 DEC 空调的表演的实验数据被获得。一些实验数据被用来训练网络直到这些数据能接近一个函数然后,与残余的数据模仿网络。预言的结果显示出... 背繁殖(BP ) 神经网络被创造预言性能一直接成为蒸气的冷却(DEC ) 有 GLASdek 的空调填。关于 DEC 空调的表演的实验数据被获得。一些实验数据被用来训练网络直到这些数据能接近一个函数然后,与残余的数据模仿网络。预言的结果显示出令人满意的效果。 展开更多
关键词 制冷技术 空气 神经网络 设计方案
下载PDF
Numerical simulation on boiling heat transfer of evaporation cooling in a billet reheating furnace
18
作者 冯明杰 王恩刚 +2 位作者 王海 李艳东 刘兵 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第6期1515-1524,共10页
The boiling heat transfer of evaporation cooling in a billet reheating furnace was simulated.The results indicate that the bubbles easily aggregate inside of the elbow and upper side of the horizontal regions in theπ... The boiling heat transfer of evaporation cooling in a billet reheating furnace was simulated.The results indicate that the bubbles easily aggregate inside of the elbow and upper side of the horizontal regions in theπshaped support tubes.The circulation velocity increasing helps to improve the uniformity of vapor distribution and decrease the difference of vapor volume fraction between upper and down at end of the horizontal sections.With the increase of circulation velocity,the resistance loss and the circulation ratio both increase,but the former will decrease with the increase of work pressure. 展开更多
关键词 钢坯加热炉 数值模拟 沸腾换热 蒸发冷却 循环速度 体积分数 阻力损失 工作压力
下载PDF
Experimental investigation of evaporative cooling systems for agricultural storage and livestock air-conditioning in Pakistan 被引量:2
19
作者 Hafiz M.U.Raza Muhammad Sultan +1 位作者 Majid Bahrami Alamgir A.Khan 《Building Simulation》 SCIE EI CSCD 2021年第3期617-631,共15页
Evaporative cooling(EC)is an ancient technique that is usually suitable for hot and dry climatic conditions due to the potential of water vapor evaporation.In this study,three kinds of evaporative cooling systems such... Evaporative cooling(EC)is an ancient technique that is usually suitable for hot and dry climatic conditions due to the potential of water vapor evaporation.In this study,three kinds of evaporative cooling systems such as direct EC(DEC),indirect EC(IEC),and Maisotsenko cycle EC(MEC)were locally developed at lab-scale.The performance of the systems was evaluated and compared for agricultural storage and livestock air-conditioning application in Pakistan.The experiments were performed for climatic conditions of Multan city(Pakistan)and the data were collected for hourly and daily basis.According to the results,it was observed that the DEC system has the ability to reduce the temperature of ambient air to an average of 8.5℃.Whilst IEC and MEC systems were able to drop the temperature of ambient air to an average of 6.8℃and 8.9℃,respectively.As per the results,the DEC system remained behind to provide desired conditions for livestock and agricultural product storage applications due to excessive humidity.On the other hand,the IEC and MEC systems can achieve the desired conditions for livestock application,but could not provide feasible conditions for various fruits and vegetable storage.The study concludes that hybrid EC systems can be developed to provide desired conditions for a wide range of applications under varying climatic conditions. 展开更多
关键词 evaporative cooling air-conditioning dew-point WET-BULB STORAGE LIVESTOCK
原文传递
Evaporative/radiative electrospun membrane for personal cooling 被引量:3
20
作者 Mohammad Irfan Iqbal Shuo Shi +1 位作者 Gokula Manikandan Senthil Kumar Jinlian Hu 《Nano Research》 SCIE EI CSCD 2023年第2期2563-2571,共9页
Functional textiles that promote daily comfort and productivity must efficiently release body sweats and transmit radiative heat through sweat evaporation and mid-infrared radiation(MIR)(8–13μm).However,most of the ... Functional textiles that promote daily comfort and productivity must efficiently release body sweats and transmit radiative heat through sweat evaporation and mid-infrared radiation(MIR)(8–13μm).However,most of the traditional clothing cannot provide simultaneous sweat evaporation and mid-infrared radiation transmission efficiently,leading to a poor design of personal cooling wearables.Herein,an evaporative/radiative integrated functional fibrous electrospun membrane is meticulously designed and controllably fabricated via facile electrospinning technology for personal cooling management.The developed membrane can be applied as a smart wearable with distinct personal thermal management applications.The promising temperature and humidity responsive vapor transmission of the membrane grants 1.2 times of evaporative cooling than that of traditional cotton.Besides,based on its high mid-infrared radiation transmission(53%)property in the range of 8–13μm,the as-spun membrane provides extra cooling of 1.5°C than that of cotton.Moreover,the building energy saving performances demonstrated that 47.1%annual building cooling can be achieved using the developed electrospun membrane.In general,the evaporative/radiative electrospun membrane creates a passive cooling microclimate for the human body,meeting the growing demand of wearable for personal cooling. 展开更多
关键词 building energy cooling management ELECTROSPINNING evaporative cooling radiative cooling
原文传递
上一页 1 2 90 下一页 到第