期刊文献+
共找到911篇文章
< 1 2 46 >
每页显示 20 50 100
Chemical Scissors Tailored Nano‑Tellurium with High‑Entropy Morphology for Efficient Foam‑Hydrogel‑Based Solar Photothermal Evaporators
1
作者 Chenyang Xing Zihao Li +4 位作者 Ziao Wang Shaohui Zhang Zhongjian Xie Xi Zhu Zhengchun Peng 《Nano-Micro Letters》 SCIE EI CSCD 2024年第3期149-168,共20页
The development of tellurium(Te)-based semiconductor nanomaterials for efficient light-to-heat conversion may offer an effective means of harvesting sunlight to address global energy concerns.However,the nanosized Te(... The development of tellurium(Te)-based semiconductor nanomaterials for efficient light-to-heat conversion may offer an effective means of harvesting sunlight to address global energy concerns.However,the nanosized Te(nano-Te)materials reported to date suffer from a series of drawbacks,including limited light absorption and a lack of surface structures.Herein,we report the preparation of nano-Te by electrochemical exfoliation using an electrolyzable room-temperature ionic liquid.Anions,cations,and their corresponding electrolytic products acting as chemical scissors can precisely intercalate and functionalize bulk Te.The resulting nano-Te has high morphological entropy,rich surface functional groups,and broad light absorption.We also constructed foam hydrogels based on poly(vinyl alcohol)/nano-Te,which achieved an evaporation rate and energy efficiency of 4.11 kg m^(−2)h^(−1)and 128%,respectively,under 1 sun irradiation.Furthermore,the evaporation rate was maintained in the range 2.5-3.0 kg m^(−2)h^(−1)outdoors under 0.5-1.0 sun,providing highly efficient evaporation under low light conditions. 展开更多
关键词 TELLURIUM High entropy Electrochemical modification Solar absorption Evaporation rate
下载PDF
Highly efficient three-dimensional solar evaporator for zero liquid discharge desalination of high-salinity brine
2
作者 Meichun Ding Demin Zhao +6 位作者 Panpan Feng Baolei Wang Zhenying Duan Rui Wei Yuxi Zhao Chen-Yang Liu Chenwei Li 《Carbon Energy》 SCIE EI CAS CSCD 2024年第9期52-65,共14页
Solar-driven interfacial evaporation is a promising technology for freshwater production from seawater,but salt accumulation on the evaporator surface hinders its performance and sustainability.In this study,we report... Solar-driven interfacial evaporation is a promising technology for freshwater production from seawater,but salt accumulation on the evaporator surface hinders its performance and sustainability.In this study,we report a simple and green strategy to fabricate a three-dimensional porous graphene spiral roll(3GSR)that enables highly efficient solar evaporation,salt collection,and water production from near-saturated brine with zero liquid discharge(ZLD).The 3GSR design facilitates energy recovery,radial brine transport,and directional salt crystallization,thereby resulting in an ultrahigh evaporation rate of 9.05 kg m^(-2) h^(-1)6 in 25 wt%brine under 1-sun illumina-tion for 48 h continuously.Remarkably,the directional salt crystallization on its outer surface not only enlarges the evaporation area but also achieves an ultrahigh salt collection rate of 2.92 kg m^(-2) h^(-1),thus enabling ZLD desalination.Additionally,3GSR exhibits a record-high water production rate of 3.14 kg m^(-2) h^(-1) in an outdoor test.This innovative solution offers a highly efficient and continuous solar desalination method for water production and ZLD brine treatment,which has great implications for addressing global water scarcity and environmental issues arising from brine disposal. 展开更多
关键词 graphene aerogels graphene composites solar desalination solar-driven interfacial evaporation
下载PDF
Influence of liquid film shape on evaporation performance of agitated thin film evaporator
3
作者 顾鑫强 黄瑶 +1 位作者 邹鲲 彭倚天 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期305-314,共10页
The agitated thin film evaporator(ATFE),which is known for its high efficiency,force the material to form a film through the scraping process of a scraper,followed by evaporation and purification.The complex shape of ... The agitated thin film evaporator(ATFE),which is known for its high efficiency,force the material to form a film through the scraping process of a scraper,followed by evaporation and purification.The complex shape of the liquid film inside the evaporator can significantly affect its evaporation capability.This work explores how change in shape of the liquid films affect the evaporation of the materials with non-Newtonian characteristics,achieved by changing the structure of the scraper.Examining the distribution of circumferential temperature,viscosity,and mass transfer of the flat liquid film shows that the film evaporates rapidly in shear-thinning region.Various wavy liquid films are developed by using shear-thinning theory,emphasizing the flow condition in the thinning area and the factors contributing to the exceptional evaporation capability.Further exploration is conducted on the spread patterns of the wavy liquid film and flat liquid film on the evaporation wall throughout the process.It is noted that breaking the wavy liquid film on the evaporating wall during evaporation is challenging due to its film-forming condition.For which the fundamental causes are demonstrated by acquiring the data regarding the flow rate and temperature of the liquid film.The definitive findings of the analysis reveal a significant improvement in the evaporation capability of the wavy liquid film.This enhancement is attributed to increasing the shear-thinning areas and maintaining the overall shape of the film throughout the entire evaporation process. 展开更多
关键词 liquid film shape shear-thinning fluids flow characteristics evaporative heat transfer
下载PDF
Effect of an Internal Heat Exchanger on the Performances of a Double Evaporator Ejector Refrigeration Cycle
4
作者 Rachedi Khadraoui Latra Boumaraf Philippe Haberschill 《Fluid Dynamics & Materials Processing》 EI 2023年第5期1115-1128,共14页
A theoretical investigation is presented about a double evaporator ejector refrigeration cycle(DEERC).Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by... A theoretical investigation is presented about a double evaporator ejector refrigeration cycle(DEERC).Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by an internal heat exchanger(IHX).The ejector is introduced into the baseline cycle in order to mitigate the throttling process losses and increase the compressor suction pressure.Moreover,the IHX has the structure of a concentric counter-flow type heat exchanger and is intentionally used to ensure that the fluid at the compressor inlet is vapor.To assess accurately the influence of the IHX on the DEERC performance,a mathematical model is derived in the frame of the dominant one-dimensional theory for ejectors.The model also accounts for the friction effect in the ejector mixing section.The equations of this model are solved using an Engineering Equation Solver(EES)for different fluids.These are:R134a as baseline fluid and other environment friendly refrigerants used for comparison,namely,R1234yf,R1234ze,R600,R600a,R290,R717 and R1270.The simulation results show that the DEERC with an IHX can achieve COP(the coefficient of performance)improvements from 5.2 until 10%. 展开更多
关键词 Refrigeration cycle double evaporator EJECTOR IHX performance improvement environment-friendlyrefrigerants
下载PDF
A Biomass-Based Hydrogel Evaporator Modified Through Dynamic Regulation of Water Molecules:Highly Efficient and Cost-Effective 被引量:1
5
作者 Boqiu Luo Jin Wen +5 位作者 Hao Wang Size Zheng Rui Liao Wenjing Chen Omid Mahian Xiaoke Li 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2023年第3期20-30,共11页
Solar-driven hydrogel evaporator used for water purification demonstrates great potential in seawater desalination and domestic sewage treatment.However,much uncertainty still exists about the most efficient design to... Solar-driven hydrogel evaporator used for water purification demonstrates great potential in seawater desalination and domestic sewage treatment.However,much uncertainty still exists about the most efficient design to obtain cost-effective drinkable water.In this paper,a natural rich biomass Nicandra physalodes(Linn.)Gaertn.polysaccharide was introduced into the polyvinyl alcohol network to control the water distribution during evaporation and build a low-cost hybrid hydrogel solar evaporator with a total material cost of$7.95 m^(−2).The mixed evaporator works stably in a long-span acid–base range(pH 1–14)and salinity range(0–320 g kg^(−1)).Its daily water purification capacity can reach 24.4 kg m^(−2)with a water purification capacity of 3.51 kg m^(−2)h^(−1)under sunlight.This paper provides a new possibility for a highly efficient and cost-effective water desalination system with guaranteed water quality by focusing on the dynamic regulation of water molecules at the evaporation interface. 展开更多
关键词 DESALINATION HYDROGELS interfacial evaporation POLYSACCHARIDE solar energy
下载PDF
Pressure Drop of Liquid–Solid Two-Phase Flow in the Vertical Tube Bundle of a Cold-Model Circulating Fluidized Bed Evaporator 被引量:2
6
作者 Feng Jiang Siyao Lv +2 位作者 Guopeng Qi Xiaoling Chen Xiulun Li 《Transactions of Tianjin University》 EI CAS 2019年第6期618-630,共13页
A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distr... A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distribution.Water and polyformaldehyde particle(POM)were used as the liquid and solid phases,respectively.The effects of operating parameters such as the amount of added particles,circulating flow rate,and particle size were systematically investigated.The results showed that the addition of the particles increased the pressure drop in the vertical tube bundle.The maximum pressure drop ratios were 18.65%,21.15%,18.00%,and 21.15%within the experimental range of the amount of added particles for POM1,POM2,POM3,and POM4,respectively.The pressure drop ratio basically decreased with the increase in the circulating flow rate but fluctuated with the increase in the amount of added particles and particle size.The difference in pressure drop ratio decreased with the increase in the circulating flow rate.As the amount of added particles increased,the difference in pressure drop ratio fluctuated at low circulating flow rate but basically decreased at high circulating flow rate.The pressure drop in the vertical tube bundle accounted for about 70%of the overall pressure drop in the up-flow heating chamber and was the main component of the overall pressure within the experimental range.Three-dimensional phase diagrams were established to display the variation ranges of the pressure drop and pressure drop ratio in the vertical tube bundle corresponding to the operating parameters.The research results can provide some reference for the application of the fluidized bed heat transfer technology in the industry. 展开更多
关键词 Pressure drop Liquid-solid two-phase flow CIRCULATING fluidized bed evaporator VERTICAL tube BUNDLE Heat transfer enhancement FOULING prevention DESCALING
下载PDF
Development and Investigation of a Miniature Copper-Acetone Loop Heat Pipe with a Flat Evaporator 被引量:3
7
作者 Yury F. Maydanik Vladimir G. Pastukhov Mariya A. Chernysheva 《Journal of Electronics Cooling and Thermal Control》 2015年第4期77-88,共12页
The paper presents the results of development and investigation of a copper miniature loop heat pipe (LHP) with acetone as a working fluid. The device was equipped with a flat evaporator measuring 80 × 42 × ... The paper presents the results of development and investigation of a copper miniature loop heat pipe (LHP) with acetone as a working fluid. The device was equipped with a flat evaporator measuring 80 × 42 × 7 mm and vapor and liquid lines with an outside diameter of 3 mm, whose lengths were 145 mm and 175 mm, respectively. The LHP was tested at heat loads from 5 W to 60 W, different orientations in the gravity field and heat-sink temperatures from -40°C to +50°C. It is shown that the LHP retains its efficiency at all testing conditions. It is also mentioned that at a heat-sink temperature of +50°C the device operates in the mode of constant conductivity in the whole range of heat loads, and in this case a minimum thermal resistance of the “heat source-heat sink” system equal to 0.16°C/W is achieved, which is independent of the LHP orientation in the gravity field. 展开更多
关键词 LOOP Heat Pipe FLAT evaporator Copper-Acetone Different Orientation
下载PDF
Liquid Flow Field on Evaporator of Wiped Short Path Distillation——Experimental Results and Computer Simulation  被引量:1
8
作者 许松林 王军武 +1 位作者 向爱双 徐世民 《Transactions of Tianjin University》 EI CAS 2005年第1期6-10,共5页
Short path distillation (SPD) is a kind of high vacuum distillation method, which is suitable for the separation of high boiling, heat sensitivity and viscidity products.In this paper,through measuring the phase-avera... Short path distillation (SPD) is a kind of high vacuum distillation method, which is suitable for the separation of high boiling, heat sensitivity and viscidity products.In this paper,through measuring the phase-averaged velocity distributions with a conditional sampling method of the particle imaging velocimetry (PIV), the liquid flow field that affects the heat and mass transfer of evaporating thin-film in an SPD evaporator is investigated.Measured results show that the flow velocities decrease rapidly apart from the wiper at different wiper velocities, the maximum velocity appears before wipers, and the quicker the wiping, the larger the flow velocity. Meanwhile, the evaluation of numerical calculations is carried out.The measured velocity distributions indicate clearly the effect of the wiper both on the flow field along its moving direction and on the vortices behind the wiper.Simulation data show that the performance of liquid flow field on the heating surface not only agrees with the experimental results well,but also can give further more information, such as the distribution of turbulent kinetic energy.In this study,turbulent kinetic energy mainly distributes before wipers and laminar flow appears far away from the wipers. 展开更多
关键词 short-path distillation turbulent liquid film particle imaging velocimetry(PIV): evaporator
下载PDF
EXPERIMENTAL RESEARCH AND DESIGN ON HEAT TRANSFER OF EVAPORATOR USED IN THE LARGE QUICK FREEZE PLANT 被引量:2
9
作者 ZHENG Chuanxiang ZHUO Chuanmin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第6期18-23,共6页
The evaporator is the main part of a quick-freeze equipment. There are many factors influencing the heat transfer coefficient of an evaporator. The most important factors among them are the fin shape, tube diameter, d... The evaporator is the main part of a quick-freeze equipment. There are many factors influencing the heat transfer coefficient of an evaporator. The most important factors among them are the fin shape, tube diameter, distance of fin space, frost, and velocity of air flow etc. They mainly influence the thermal efficiency of an evaporator, and therefore its thermal efficiency has direct relationship with the whole efficiency of the quick freeze plant. Evaporators with different structural types have different heat transfer efficiency, in order to obtain high efficiency structure of evaporator, 8 evaporator models with different fin shape, tube diameter and tube arrangement are analyzed and compared. The calculation results show that the integral waved fins, equilateral-triangle arranged small diameter tubes and varying fin-spacing has the highest heat transfer coefficient. The experimental result also shows that the evaporator with this type of structure has better thermal efficiency. The experimental result is in good agreement with the calculation result, it can instruct engineering design for usual designer. A real quick-freeze equipment is designed and put into production. The result shows that, compared with traditional domestic quick-freeze equipments, this equipment decreases by 40% in size and by 20% in energy consumption. 展开更多
关键词 Heat transfer coefficient evaporator Quick freeze plant Theoretical and experimental research Application
下载PDF
Performance Assessment of a Shell Tube Evaporator for a Model Organic Rankine Cycle for Use in Geothermal Power Plant 被引量:1
10
作者 Haile Araya Nigusse Hiram M. Ndiritu Robert Kiplimo 《Journal of Power and Energy Engineering》 2014年第10期9-18,共10页
The global energy demand increases with development and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy ... The global energy demand increases with development and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy resources such as fossil fuels have been declining and harmful combustion byproducts are causing global warming. The Organic Rankine Cycle power plant is a very effective option for utilization of low grade heat sources for power generation. In the Organic Rankine Cycle heat exchangers such as evaporators and condensers are key components that determine its performance. Researches indicated that shell tube heat exchangers are effectively utilized in this cycle. The design of the heat exchanger involves establishing the right flow pattern of the interacting fluids. The performance of these exchangers can be optimized by inserting baffles in the shell to direct the flow of fluid across the tubes on shell side. In this work heat exchangers have been developed to improve heat recovery from geothermal brine for additional power generation. The design involved sizing of heat exchanger (evaporator) using the LMTD method based on an expected heat transfer rate. The heat exchanger of the model power plant was tested in which hot water simulated brine. The results indicated that the heat exchanger is thermally suitable for the evaporator of the model power plant. 展开更多
关键词 SHELL TUBE evaporator HEAT TRANSFER Co-Efficient LMTD ORC
下载PDF
Numerical Study of Thermal Performance of a Capillary Evaporator in a Loop Heat Pipe with Liquid-Saturated Wick 被引量:1
11
作者 Masahito Nishikawara Hosei Nagano +1 位作者 Laetitia Mottet Marc Prat 《Journal of Electronics Cooling and Thermal Control》 2014年第4期118-127,共10页
Heat transfer of a capillary evaporator in a loop heat pipe was analyzed through 3D numerical simulations to study the effects of the thermal conductivity of the wick, the contact area between the casing and the wick,... Heat transfer of a capillary evaporator in a loop heat pipe was analyzed through 3D numerical simulations to study the effects of the thermal conductivity of the wick, the contact area between the casing and the wick, and the subcooling in the compensation chamber (CC) on the thermal performance of the evaporator. A pore network model with a distribution of pore radii was used to simulate liquid flow in the porous structure of the wick. To obtain high accuracy, fine meshes were used at the boundaries among the casing, the wick, and the grooves. Distributions of temperature, pressure, and mass flow rate were compared for polytetra-fluoroethylene (PTFE) and stainless steel wicks. The thermal conductivity of the wick and the contact area between the casing and the wick significantly impacted thermal performance of the evaporator heat-transfer coefficient and the heat leak to the CC. The 3D analysis provided highly accurate values for the heat leak;in some cases, the heat leaks of PTFE and stainless steel wicks showed little differences. In general, the heat flux is concentrated at the boundaries between the casing, the wick, and the grooves;therefore, thermal performance can be optimized by increasing the length of the boundary. 展开更多
关键词 CAPILLARY evaporator Loop HEAT Pipe Numerical Simulation PORE Network Model TWO-PHASE HEAT Transfer
下载PDF
INVERSE CIRCULATING THERMOSYPHON EVAPORATOR
12
作者 沙庆云 仝爱星 +2 位作者 李淞平 沈自求 B.H.Chen 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1994年第1期43-51,共9页
In this paper,the mechanism of operation of an inverse circulating thermosyphon evaporator isproposed.The performance characteristics of this novel evaporator have been studied experimentally andtheoretically,The inve... In this paper,the mechanism of operation of an inverse circulating thermosyphon evaporator isproposed.The performance characteristics of this novel evaporator have been studied experimentally andtheoretically,The inverse circulating thermosyphon evaporators have higher heat transfer coefficient and longeroperation period in comparison with ordinary circulating ordinary circulating evaporators. 展开更多
关键词 evaporator HEAT TRANSFER two phase flow
下载PDF
BP-PID Control Applied in Evaporator of Organic Rankine Cycle System 被引量:1
13
作者 WANG Zhigang GUO Shuang 《Instrumentation》 2017年第3期54-58,共5页
According to the problem that the selection of traditional PID control parameters is too complicated in evaporator of Organic Rankine Cycle system(ORC),an evaporator PID controller based on BP neural netw ork optimiza... According to the problem that the selection of traditional PID control parameters is too complicated in evaporator of Organic Rankine Cycle system(ORC),an evaporator PID controller based on BP neural netw ork optimization is designed. Based on the control theory,the model of ORC evaporator is set up. The BP algorithm is used to control the Kp,Kiand Kdparameters of the evaporator PID controller,so that the evaporator temperature can reach the optimal state quickly and steadily. The M ATLAB softw are is used to simulate the traditional PID controller and the BP neural netw ork PID controller. The experimental results show that the Kp,Kiand Kdparameters of the BP neural netw ork PID controller are 0. 5677,0. 2970,and 0. 1353,respectively.Therefore,the evaporator PID controller based on BP neural netw ork optimization not only satisfies the requirements of the system performance,but also has better control parameters than the traditional PID controller. 展开更多
关键词 Organic Rankine Cycle PID Controller evaporator BP Neural Network
下载PDF
Investigation of Geometric Factors of Convex Platforms in the Flat Evaporator of Loop Heat Pipes
14
作者 Ge Zhang Wenshuai Miao +2 位作者 Li Liu Yingying Hong Jiao Bai 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2017年第6期90-96,共7页
This paper investigated the influence of geometric factors of vapor groove structures on the performance of flat evaporator of a loop heat pipe system. COMSOL multiphysics software was employed to simulate the heat tr... This paper investigated the influence of geometric factors of vapor groove structures on the performance of flat evaporator of a loop heat pipe system. COMSOL multiphysics software was employed to simulate the heat transfer in the evaporator with convex platforms of different shapes,sizes and area ratios(φ)between convex platforms and the heated surface. The maximum temperature and temperature distribution of each model were obtained. The results showed that the decrease of the size of platforms and the increase of φ can lower temperatures and improve temperature distribution homogeneity of the heated surface. Compared with circle and oval platforms,square platforms achieved lower temperature. The results also indicated that φ had the most significant impact on the performance of the evaporator. 展开更多
关键词 loop heat pipe FLAT evaporator vapor GROOVE structure GEOMETRIC factor
下载PDF
INFLUENCE OF REFRIGERANT DISTRIBUTION ON HEAT TRANSFER IN EVAPORATORS
15
作者 高原 田怀璋 +1 位作者 曾艳 袁秀玲 《Journal of Pharmaceutical Analysis》 SCIE CAS 2003年第1期10-14,共5页
Objective To prevent the maldistribution of two phase refrigerant in dry expansion evaporators composed of parallel coils, a distributor is needed to supply refrigerant into the coils. Methods A simplified model of... Objective To prevent the maldistribution of two phase refrigerant in dry expansion evaporators composed of parallel coils, a distributor is needed to supply refrigerant into the coils. Methods A simplified model of dry expansion evaporator was proposed. The flow and heat transfer in distributing pipes and evaporator coils were simulated with a numerical method. Results The heat flow rate decreases while the refrigerant is distributed unequally to evaporator coils. Conclusion In order to maintain the heat flow rate, larger heat transfer area should be arranged to make up the effect of maldistribution. The larger the discrepancy of mass flow rate is, the more heat transfer area is needed. 展开更多
关键词 DISTRIBUTOR CAPILLARY evaporator numerical simulation
下载PDF
Numerical simulation of liquid desiccant evaporator driven by heat pump
16
作者 NIU Run-ping CHEN Xiao-yi +1 位作者 WANG Zi-ye KUANG Da-qing 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第8期2197-2213,共17页
The standard k-ε turbulence model and discrete phase model (DPM) were used to simulate the heat and mass transfer in a liquid-desiccant evaporator driven by a heat pump using FLUENT software, and the temperature fiel... The standard k-ε turbulence model and discrete phase model (DPM) were used to simulate the heat and mass transfer in a liquid-desiccant evaporator driven by a heat pump using FLUENT software, and the temperature field and velocity field in the device were obtained. The performance of the liquid-desiccant evaporator was studied as the concentration of the inlet solution varied between 21% and 30% and the pipe wall temperature between 30 and 50 ℃. Results show that the humidification rate and the humidification efficiency increased with the inlet air temperature, the solution flow rate, the solution temperature, and the pipe wall temperature. The humidification rate and humidification efficiency decreased with increasing moisture content in inlet air and the concentration of inlet solution. The humidification rate increased substantially but the humidification efficiency decreased as the inlet air flow rate increased. The error between the simulations and experimental results is acceptable, meaning that our model can provide a theoretical basis for optimizing the performance of a humidifying evaporator. 展开更多
关键词 heat pump condensation heat discrete phase model (DPM) liquid desiccant evaporator numerical simulation
下载PDF
Heat Transfer Characteristics and Pressure Drop in a Horizontal Circulating Fluidized Bed Evaporator
17
作者 Xu Liang Feng Jiang +5 位作者 Guopeng Qi Jinjin Wang Xinhua Dong Wenyue Jing Ruijia Li Xiulun Li 《Transactions of Tianjin University》 EI CAS 2021年第6期487-504,共18页
A vapor-liquid-solid horizontal circulating fluidized bed evaporation setup was constructed to study the thermal-exchange properties and pressure change.The influences of the operating variables,including the amount o... A vapor-liquid-solid horizontal circulating fluidized bed evaporation setup was constructed to study the thermal-exchange properties and pressure change.The influences of the operating variables,including the amount of added particles,heat flux,and circulating flow velocity,were systematically inspected using resistance temperature detectors and pressure sensors.The results showed that the heat transfer eff ect was improved with the increase in the amount of added particles,circulating flow velocity,and particle diameter,but decreased with increasing heat flux.The pressure drop fluctuated with the increase in operating parameters,except circulating flow velocity.The enhancing factor reached up to 71.5%.The enhancing fac-tor initially increased and then decreased with the increase in the amount of added particles and circulating flow velocity,fluctuated with increasing particle diameter,and decreased with increasing heat flux.Phase diagrams showing the variation ranges of the operation variables for the enhancing factor were constructed. 展开更多
关键词 Heat transfer characteristics Pressure drop Horizontal circulating fluidized bed evaporator Vertical heights Fouling prevention and removal
下载PDF
The Application of Synthetic Fuzzy Assessing Method in Measurement and Control System of Plating Solution Evaporator
18
作者 周晓兵 费敏锐 陈维刚 《Journal of Donghua University(English Edition)》 EI CAS 2004年第3期134-138,共5页
The synthetic fuzzy assessing method is usually applied to sensory evaluation. The method has simple and reliable virtue, and it is consistent with objective evaluation results. Using this method, system status of pla... The synthetic fuzzy assessing method is usually applied to sensory evaluation. The method has simple and reliable virtue, and it is consistent with objective evaluation results. Using this method, system status of plating solution evaporator is evaluated, and the result is applied to compensate a fuzzy controller. Experimental results have shown the correctness and the validity of the proposed approach. 展开更多
关键词 Plating solution evaporator Synthetic fuzzy assessing method fuzzy control PC-BASED configuration software
下载PDF
The Characteristics of the Evaporator/Evaporator for Direct Expansion Solar Assisted Heat Pump System
19
作者 Mingyan Zhu Huanrong Xie +1 位作者 Biao Zhang Xin Guan 《Journal of Power and Energy Engineering》 2013年第5期73-76,共4页
Direct expansion solar assisted heat pump (DX-SAHP) technology is developed by combining solar energy heat utilization with heat pump energy saving technology. The experimental researches of the DX-SAHP hot water syst... Direct expansion solar assisted heat pump (DX-SAHP) technology is developed by combining solar energy heat utilization with heat pump energy saving technology. The experimental researches of the DX-SAHP hot water system are conducted in this paper, and overall performance of DX-SAHP is analyzed with three different structures of collectors/evaporators, namely a bare-plate collector, a glass-plate collector and double collectors/evaporators (a bare-plate collector and a glass-plate collector). The influence factors and overall performance are studied, which show that the overall performance of the system is mainly influenced by solar irradiation intensity and the collector area. Comparing with glass-plate collector in similar conditions, bare-plate collector system COP is higher. While increasing collector area is conducive to improve the system COP, but will reduce the collector efficiency and increase the workload of the compressor by comparing the bare-plate collector with double-plate collectors. 展开更多
关键词 Direct EXPANSION SOLAR ASSISTED HEAT PUMP Collector/evaporator Experimental Research
下载PDF
Experimental Investigation on the Effection of Flow Regulator in a Multiple Evaporators/Condensers Loop Heat Pipe with Plastic Porous Structure
20
作者 Xinyu Chang H. Nagano 《Journal of Power and Energy Engineering》 2014年第9期49-56,共8页
Multiple loop heat pipes which have two evaporators and two condensers in one loop are a kind of active heat transfer device. Since they have two evaporators and two condensers, the operating mode also becomes multipl... Multiple loop heat pipes which have two evaporators and two condensers in one loop are a kind of active heat transfer device. Since they have two evaporators and two condensers, the operating mode also becomes multiple. This work discusses the cases that multiple loop heat pipes were operated with one condenser at high temperature and the other at low temperature. To avoid the high temperature returning liquid and keep the multiple loop heat pipes work properly, the flow regulator which was made of polyethylene was designed, fabricated and applied in this test. The effect of flow regulator was confirmed and analyzed. In the test that large temperature difference existed between two sinks, it can be found according to the result that the flow regulator worked effectively and prevented the high temperature vapor to enter the inlet of common liquid line, which can keep the evaporators and returning liquid to operate at low temperature. With the increment of heat loads and the temperature difference between two sinks, the pressure difference between two condensers became larger and larger. When the pressure difference was larger than the flow regulator’s capillary force, the flow regulator could not work properly because the high temperature vapor began to flow through the flow regulator. According to the test data, the flow regulator can work properly within the sinks’ temperature 0&deg;C/60&deg;C and the two evaporators’ heat load 30/30 W. 展开更多
关键词 Flow REGULATOR Loop HEAT Pipe MULTIPLE evaporators and CONDENSERS Two-Phase HEAT Transfer
下载PDF
上一页 1 2 46 下一页 到第
使用帮助 返回顶部