The development of tellurium(Te)-based semiconductor nanomaterials for efficient light-to-heat conversion may offer an effective means of harvesting sunlight to address global energy concerns.However,the nanosized Te(...The development of tellurium(Te)-based semiconductor nanomaterials for efficient light-to-heat conversion may offer an effective means of harvesting sunlight to address global energy concerns.However,the nanosized Te(nano-Te)materials reported to date suffer from a series of drawbacks,including limited light absorption and a lack of surface structures.Herein,we report the preparation of nano-Te by electrochemical exfoliation using an electrolyzable room-temperature ionic liquid.Anions,cations,and their corresponding electrolytic products acting as chemical scissors can precisely intercalate and functionalize bulk Te.The resulting nano-Te has high morphological entropy,rich surface functional groups,and broad light absorption.We also constructed foam hydrogels based on poly(vinyl alcohol)/nano-Te,which achieved an evaporation rate and energy efficiency of 4.11 kg m^(−2)h^(−1)and 128%,respectively,under 1 sun irradiation.Furthermore,the evaporation rate was maintained in the range 2.5-3.0 kg m^(−2)h^(−1)outdoors under 0.5-1.0 sun,providing highly efficient evaporation under low light conditions.展开更多
Solar-driven interfacial evaporation is a promising technology for freshwater production from seawater,but salt accumulation on the evaporator surface hinders its performance and sustainability.In this study,we report...Solar-driven interfacial evaporation is a promising technology for freshwater production from seawater,but salt accumulation on the evaporator surface hinders its performance and sustainability.In this study,we report a simple and green strategy to fabricate a three-dimensional porous graphene spiral roll(3GSR)that enables highly efficient solar evaporation,salt collection,and water production from near-saturated brine with zero liquid discharge(ZLD).The 3GSR design facilitates energy recovery,radial brine transport,and directional salt crystallization,thereby resulting in an ultrahigh evaporation rate of 9.05 kg m^(-2) h^(-1)6 in 25 wt%brine under 1-sun illumina-tion for 48 h continuously.Remarkably,the directional salt crystallization on its outer surface not only enlarges the evaporation area but also achieves an ultrahigh salt collection rate of 2.92 kg m^(-2) h^(-1),thus enabling ZLD desalination.Additionally,3GSR exhibits a record-high water production rate of 3.14 kg m^(-2) h^(-1) in an outdoor test.This innovative solution offers a highly efficient and continuous solar desalination method for water production and ZLD brine treatment,which has great implications for addressing global water scarcity and environmental issues arising from brine disposal.展开更多
The agitated thin film evaporator(ATFE),which is known for its high efficiency,force the material to form a film through the scraping process of a scraper,followed by evaporation and purification.The complex shape of ...The agitated thin film evaporator(ATFE),which is known for its high efficiency,force the material to form a film through the scraping process of a scraper,followed by evaporation and purification.The complex shape of the liquid film inside the evaporator can significantly affect its evaporation capability.This work explores how change in shape of the liquid films affect the evaporation of the materials with non-Newtonian characteristics,achieved by changing the structure of the scraper.Examining the distribution of circumferential temperature,viscosity,and mass transfer of the flat liquid film shows that the film evaporates rapidly in shear-thinning region.Various wavy liquid films are developed by using shear-thinning theory,emphasizing the flow condition in the thinning area and the factors contributing to the exceptional evaporation capability.Further exploration is conducted on the spread patterns of the wavy liquid film and flat liquid film on the evaporation wall throughout the process.It is noted that breaking the wavy liquid film on the evaporating wall during evaporation is challenging due to its film-forming condition.For which the fundamental causes are demonstrated by acquiring the data regarding the flow rate and temperature of the liquid film.The definitive findings of the analysis reveal a significant improvement in the evaporation capability of the wavy liquid film.This enhancement is attributed to increasing the shear-thinning areas and maintaining the overall shape of the film throughout the entire evaporation process.展开更多
A theoretical investigation is presented about a double evaporator ejector refrigeration cycle(DEERC).Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by...A theoretical investigation is presented about a double evaporator ejector refrigeration cycle(DEERC).Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by an internal heat exchanger(IHX).The ejector is introduced into the baseline cycle in order to mitigate the throttling process losses and increase the compressor suction pressure.Moreover,the IHX has the structure of a concentric counter-flow type heat exchanger and is intentionally used to ensure that the fluid at the compressor inlet is vapor.To assess accurately the influence of the IHX on the DEERC performance,a mathematical model is derived in the frame of the dominant one-dimensional theory for ejectors.The model also accounts for the friction effect in the ejector mixing section.The equations of this model are solved using an Engineering Equation Solver(EES)for different fluids.These are:R134a as baseline fluid and other environment friendly refrigerants used for comparison,namely,R1234yf,R1234ze,R600,R600a,R290,R717 and R1270.The simulation results show that the DEERC with an IHX can achieve COP(the coefficient of performance)improvements from 5.2 until 10%.展开更多
Solar-driven hydrogel evaporator used for water purification demonstrates great potential in seawater desalination and domestic sewage treatment.However,much uncertainty still exists about the most efficient design to...Solar-driven hydrogel evaporator used for water purification demonstrates great potential in seawater desalination and domestic sewage treatment.However,much uncertainty still exists about the most efficient design to obtain cost-effective drinkable water.In this paper,a natural rich biomass Nicandra physalodes(Linn.)Gaertn.polysaccharide was introduced into the polyvinyl alcohol network to control the water distribution during evaporation and build a low-cost hybrid hydrogel solar evaporator with a total material cost of$7.95 m^(−2).The mixed evaporator works stably in a long-span acid–base range(pH 1–14)and salinity range(0–320 g kg^(−1)).Its daily water purification capacity can reach 24.4 kg m^(−2)with a water purification capacity of 3.51 kg m^(−2)h^(−1)under sunlight.This paper provides a new possibility for a highly efficient and cost-effective water desalination system with guaranteed water quality by focusing on the dynamic regulation of water molecules at the evaporation interface.展开更多
A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distr...A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distribution.Water and polyformaldehyde particle(POM)were used as the liquid and solid phases,respectively.The effects of operating parameters such as the amount of added particles,circulating flow rate,and particle size were systematically investigated.The results showed that the addition of the particles increased the pressure drop in the vertical tube bundle.The maximum pressure drop ratios were 18.65%,21.15%,18.00%,and 21.15%within the experimental range of the amount of added particles for POM1,POM2,POM3,and POM4,respectively.The pressure drop ratio basically decreased with the increase in the circulating flow rate but fluctuated with the increase in the amount of added particles and particle size.The difference in pressure drop ratio decreased with the increase in the circulating flow rate.As the amount of added particles increased,the difference in pressure drop ratio fluctuated at low circulating flow rate but basically decreased at high circulating flow rate.The pressure drop in the vertical tube bundle accounted for about 70%of the overall pressure drop in the up-flow heating chamber and was the main component of the overall pressure within the experimental range.Three-dimensional phase diagrams were established to display the variation ranges of the pressure drop and pressure drop ratio in the vertical tube bundle corresponding to the operating parameters.The research results can provide some reference for the application of the fluidized bed heat transfer technology in the industry.展开更多
The paper presents the results of development and investigation of a copper miniature loop heat pipe (LHP) with acetone as a working fluid. The device was equipped with a flat evaporator measuring 80 × 42 × ...The paper presents the results of development and investigation of a copper miniature loop heat pipe (LHP) with acetone as a working fluid. The device was equipped with a flat evaporator measuring 80 × 42 × 7 mm and vapor and liquid lines with an outside diameter of 3 mm, whose lengths were 145 mm and 175 mm, respectively. The LHP was tested at heat loads from 5 W to 60 W, different orientations in the gravity field and heat-sink temperatures from -40°C to +50°C. It is shown that the LHP retains its efficiency at all testing conditions. It is also mentioned that at a heat-sink temperature of +50°C the device operates in the mode of constant conductivity in the whole range of heat loads, and in this case a minimum thermal resistance of the “heat source-heat sink” system equal to 0.16°C/W is achieved, which is independent of the LHP orientation in the gravity field.展开更多
Short path distillation (SPD) is a kind of high vacuum distillation method, which is suitable for the separation of high boiling, heat sensitivity and viscidity products.In this paper,through measuring the phase-avera...Short path distillation (SPD) is a kind of high vacuum distillation method, which is suitable for the separation of high boiling, heat sensitivity and viscidity products.In this paper,through measuring the phase-averaged velocity distributions with a conditional sampling method of the particle imaging velocimetry (PIV), the liquid flow field that affects the heat and mass transfer of evaporating thin-film in an SPD evaporator is investigated.Measured results show that the flow velocities decrease rapidly apart from the wiper at different wiper velocities, the maximum velocity appears before wipers, and the quicker the wiping, the larger the flow velocity. Meanwhile, the evaluation of numerical calculations is carried out.The measured velocity distributions indicate clearly the effect of the wiper both on the flow field along its moving direction and on the vortices behind the wiper.Simulation data show that the performance of liquid flow field on the heating surface not only agrees with the experimental results well,but also can give further more information, such as the distribution of turbulent kinetic energy.In this study,turbulent kinetic energy mainly distributes before wipers and laminar flow appears far away from the wipers.展开更多
The evaporator is the main part of a quick-freeze equipment. There are many factors influencing the heat transfer coefficient of an evaporator. The most important factors among them are the fin shape, tube diameter, d...The evaporator is the main part of a quick-freeze equipment. There are many factors influencing the heat transfer coefficient of an evaporator. The most important factors among them are the fin shape, tube diameter, distance of fin space, frost, and velocity of air flow etc. They mainly influence the thermal efficiency of an evaporator, and therefore its thermal efficiency has direct relationship with the whole efficiency of the quick freeze plant. Evaporators with different structural types have different heat transfer efficiency, in order to obtain high efficiency structure of evaporator, 8 evaporator models with different fin shape, tube diameter and tube arrangement are analyzed and compared. The calculation results show that the integral waved fins, equilateral-triangle arranged small diameter tubes and varying fin-spacing has the highest heat transfer coefficient. The experimental result also shows that the evaporator with this type of structure has better thermal efficiency. The experimental result is in good agreement with the calculation result, it can instruct engineering design for usual designer. A real quick-freeze equipment is designed and put into production. The result shows that, compared with traditional domestic quick-freeze equipments, this equipment decreases by 40% in size and by 20% in energy consumption.展开更多
The global energy demand increases with development and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy ...The global energy demand increases with development and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy resources such as fossil fuels have been declining and harmful combustion byproducts are causing global warming. The Organic Rankine Cycle power plant is a very effective option for utilization of low grade heat sources for power generation. In the Organic Rankine Cycle heat exchangers such as evaporators and condensers are key components that determine its performance. Researches indicated that shell tube heat exchangers are effectively utilized in this cycle. The design of the heat exchanger involves establishing the right flow pattern of the interacting fluids. The performance of these exchangers can be optimized by inserting baffles in the shell to direct the flow of fluid across the tubes on shell side. In this work heat exchangers have been developed to improve heat recovery from geothermal brine for additional power generation. The design involved sizing of heat exchanger (evaporator) using the LMTD method based on an expected heat transfer rate. The heat exchanger of the model power plant was tested in which hot water simulated brine. The results indicated that the heat exchanger is thermally suitable for the evaporator of the model power plant.展开更多
Heat transfer of a capillary evaporator in a loop heat pipe was analyzed through 3D numerical simulations to study the effects of the thermal conductivity of the wick, the contact area between the casing and the wick,...Heat transfer of a capillary evaporator in a loop heat pipe was analyzed through 3D numerical simulations to study the effects of the thermal conductivity of the wick, the contact area between the casing and the wick, and the subcooling in the compensation chamber (CC) on the thermal performance of the evaporator. A pore network model with a distribution of pore radii was used to simulate liquid flow in the porous structure of the wick. To obtain high accuracy, fine meshes were used at the boundaries among the casing, the wick, and the grooves. Distributions of temperature, pressure, and mass flow rate were compared for polytetra-fluoroethylene (PTFE) and stainless steel wicks. The thermal conductivity of the wick and the contact area between the casing and the wick significantly impacted thermal performance of the evaporator heat-transfer coefficient and the heat leak to the CC. The 3D analysis provided highly accurate values for the heat leak;in some cases, the heat leaks of PTFE and stainless steel wicks showed little differences. In general, the heat flux is concentrated at the boundaries between the casing, the wick, and the grooves;therefore, thermal performance can be optimized by increasing the length of the boundary.展开更多
In this paper,the mechanism of operation of an inverse circulating thermosyphon evaporator isproposed.The performance characteristics of this novel evaporator have been studied experimentally andtheoretically,The inve...In this paper,the mechanism of operation of an inverse circulating thermosyphon evaporator isproposed.The performance characteristics of this novel evaporator have been studied experimentally andtheoretically,The inverse circulating thermosyphon evaporators have higher heat transfer coefficient and longeroperation period in comparison with ordinary circulating ordinary circulating evaporators.展开更多
According to the problem that the selection of traditional PID control parameters is too complicated in evaporator of Organic Rankine Cycle system(ORC),an evaporator PID controller based on BP neural netw ork optimiza...According to the problem that the selection of traditional PID control parameters is too complicated in evaporator of Organic Rankine Cycle system(ORC),an evaporator PID controller based on BP neural netw ork optimization is designed. Based on the control theory,the model of ORC evaporator is set up. The BP algorithm is used to control the Kp,Kiand Kdparameters of the evaporator PID controller,so that the evaporator temperature can reach the optimal state quickly and steadily. The M ATLAB softw are is used to simulate the traditional PID controller and the BP neural netw ork PID controller. The experimental results show that the Kp,Kiand Kdparameters of the BP neural netw ork PID controller are 0. 5677,0. 2970,and 0. 1353,respectively.Therefore,the evaporator PID controller based on BP neural netw ork optimization not only satisfies the requirements of the system performance,but also has better control parameters than the traditional PID controller.展开更多
This paper investigated the influence of geometric factors of vapor groove structures on the performance of flat evaporator of a loop heat pipe system. COMSOL multiphysics software was employed to simulate the heat tr...This paper investigated the influence of geometric factors of vapor groove structures on the performance of flat evaporator of a loop heat pipe system. COMSOL multiphysics software was employed to simulate the heat transfer in the evaporator with convex platforms of different shapes,sizes and area ratios(φ)between convex platforms and the heated surface. The maximum temperature and temperature distribution of each model were obtained. The results showed that the decrease of the size of platforms and the increase of φ can lower temperatures and improve temperature distribution homogeneity of the heated surface. Compared with circle and oval platforms,square platforms achieved lower temperature. The results also indicated that φ had the most significant impact on the performance of the evaporator.展开更多
Objective To prevent the maldistribution of two phase refrigerant in dry expansion evaporators composed of parallel coils, a distributor is needed to supply refrigerant into the coils. Methods A simplified model of...Objective To prevent the maldistribution of two phase refrigerant in dry expansion evaporators composed of parallel coils, a distributor is needed to supply refrigerant into the coils. Methods A simplified model of dry expansion evaporator was proposed. The flow and heat transfer in distributing pipes and evaporator coils were simulated with a numerical method. Results The heat flow rate decreases while the refrigerant is distributed unequally to evaporator coils. Conclusion In order to maintain the heat flow rate, larger heat transfer area should be arranged to make up the effect of maldistribution. The larger the discrepancy of mass flow rate is, the more heat transfer area is needed.展开更多
The standard k-ε turbulence model and discrete phase model (DPM) were used to simulate the heat and mass transfer in a liquid-desiccant evaporator driven by a heat pump using FLUENT software, and the temperature fiel...The standard k-ε turbulence model and discrete phase model (DPM) were used to simulate the heat and mass transfer in a liquid-desiccant evaporator driven by a heat pump using FLUENT software, and the temperature field and velocity field in the device were obtained. The performance of the liquid-desiccant evaporator was studied as the concentration of the inlet solution varied between 21% and 30% and the pipe wall temperature between 30 and 50 ℃. Results show that the humidification rate and the humidification efficiency increased with the inlet air temperature, the solution flow rate, the solution temperature, and the pipe wall temperature. The humidification rate and humidification efficiency decreased with increasing moisture content in inlet air and the concentration of inlet solution. The humidification rate increased substantially but the humidification efficiency decreased as the inlet air flow rate increased. The error between the simulations and experimental results is acceptable, meaning that our model can provide a theoretical basis for optimizing the performance of a humidifying evaporator.展开更多
A vapor-liquid-solid horizontal circulating fluidized bed evaporation setup was constructed to study the thermal-exchange properties and pressure change.The influences of the operating variables,including the amount o...A vapor-liquid-solid horizontal circulating fluidized bed evaporation setup was constructed to study the thermal-exchange properties and pressure change.The influences of the operating variables,including the amount of added particles,heat flux,and circulating flow velocity,were systematically inspected using resistance temperature detectors and pressure sensors.The results showed that the heat transfer eff ect was improved with the increase in the amount of added particles,circulating flow velocity,and particle diameter,but decreased with increasing heat flux.The pressure drop fluctuated with the increase in operating parameters,except circulating flow velocity.The enhancing factor reached up to 71.5%.The enhancing fac-tor initially increased and then decreased with the increase in the amount of added particles and circulating flow velocity,fluctuated with increasing particle diameter,and decreased with increasing heat flux.Phase diagrams showing the variation ranges of the operation variables for the enhancing factor were constructed.展开更多
The synthetic fuzzy assessing method is usually applied to sensory evaluation. The method has simple and reliable virtue, and it is consistent with objective evaluation results. Using this method, system status of pla...The synthetic fuzzy assessing method is usually applied to sensory evaluation. The method has simple and reliable virtue, and it is consistent with objective evaluation results. Using this method, system status of plating solution evaporator is evaluated, and the result is applied to compensate a fuzzy controller. Experimental results have shown the correctness and the validity of the proposed approach.展开更多
Direct expansion solar assisted heat pump (DX-SAHP) technology is developed by combining solar energy heat utilization with heat pump energy saving technology. The experimental researches of the DX-SAHP hot water syst...Direct expansion solar assisted heat pump (DX-SAHP) technology is developed by combining solar energy heat utilization with heat pump energy saving technology. The experimental researches of the DX-SAHP hot water system are conducted in this paper, and overall performance of DX-SAHP is analyzed with three different structures of collectors/evaporators, namely a bare-plate collector, a glass-plate collector and double collectors/evaporators (a bare-plate collector and a glass-plate collector). The influence factors and overall performance are studied, which show that the overall performance of the system is mainly influenced by solar irradiation intensity and the collector area. Comparing with glass-plate collector in similar conditions, bare-plate collector system COP is higher. While increasing collector area is conducive to improve the system COP, but will reduce the collector efficiency and increase the workload of the compressor by comparing the bare-plate collector with double-plate collectors.展开更多
Multiple loop heat pipes which have two evaporators and two condensers in one loop are a kind of active heat transfer device. Since they have two evaporators and two condensers, the operating mode also becomes multipl...Multiple loop heat pipes which have two evaporators and two condensers in one loop are a kind of active heat transfer device. Since they have two evaporators and two condensers, the operating mode also becomes multiple. This work discusses the cases that multiple loop heat pipes were operated with one condenser at high temperature and the other at low temperature. To avoid the high temperature returning liquid and keep the multiple loop heat pipes work properly, the flow regulator which was made of polyethylene was designed, fabricated and applied in this test. The effect of flow regulator was confirmed and analyzed. In the test that large temperature difference existed between two sinks, it can be found according to the result that the flow regulator worked effectively and prevented the high temperature vapor to enter the inlet of common liquid line, which can keep the evaporators and returning liquid to operate at low temperature. With the increment of heat loads and the temperature difference between two sinks, the pressure difference between two condensers became larger and larger. When the pressure difference was larger than the flow regulator’s capillary force, the flow regulator could not work properly because the high temperature vapor began to flow through the flow regulator. According to the test data, the flow regulator can work properly within the sinks’ temperature 0°C/60°C and the two evaporators’ heat load 30/30 W.展开更多
基金the Science and Technology Innovation Council of Shenzhen(Grant Nos.JCYJ20200109105212568,KQTD20170810105439418,JCYJ20200109114237902,20200812203318002,and 20200810103814002)the National Natural Science Foundation of China(Grant No.12274197)the Guangdong Basic and Applied Basic Research Foundation(Grant Nos.2023A1515030240,2019A1515010790,2021A0505110015).
文摘The development of tellurium(Te)-based semiconductor nanomaterials for efficient light-to-heat conversion may offer an effective means of harvesting sunlight to address global energy concerns.However,the nanosized Te(nano-Te)materials reported to date suffer from a series of drawbacks,including limited light absorption and a lack of surface structures.Herein,we report the preparation of nano-Te by electrochemical exfoliation using an electrolyzable room-temperature ionic liquid.Anions,cations,and their corresponding electrolytic products acting as chemical scissors can precisely intercalate and functionalize bulk Te.The resulting nano-Te has high morphological entropy,rich surface functional groups,and broad light absorption.We also constructed foam hydrogels based on poly(vinyl alcohol)/nano-Te,which achieved an evaporation rate and energy efficiency of 4.11 kg m^(−2)h^(−1)and 128%,respectively,under 1 sun irradiation.Furthermore,the evaporation rate was maintained in the range 2.5-3.0 kg m^(−2)h^(−1)outdoors under 0.5-1.0 sun,providing highly efficient evaporation under low light conditions.
基金This work was supported by the Taishan Young Scholar Program(tsqn202306267)the National Natural Science Foundation of China(51802168)the Natural Science Foundation of Shandong Province(ZR2023ME172).
文摘Solar-driven interfacial evaporation is a promising technology for freshwater production from seawater,but salt accumulation on the evaporator surface hinders its performance and sustainability.In this study,we report a simple and green strategy to fabricate a three-dimensional porous graphene spiral roll(3GSR)that enables highly efficient solar evaporation,salt collection,and water production from near-saturated brine with zero liquid discharge(ZLD).The 3GSR design facilitates energy recovery,radial brine transport,and directional salt crystallization,thereby resulting in an ultrahigh evaporation rate of 9.05 kg m^(-2) h^(-1)6 in 25 wt%brine under 1-sun illumina-tion for 48 h continuously.Remarkably,the directional salt crystallization on its outer surface not only enlarges the evaporation area but also achieves an ultrahigh salt collection rate of 2.92 kg m^(-2) h^(-1),thus enabling ZLD desalination.Additionally,3GSR exhibits a record-high water production rate of 3.14 kg m^(-2) h^(-1) in an outdoor test.This innovative solution offers a highly efficient and continuous solar desalination method for water production and ZLD brine treatment,which has great implications for addressing global water scarcity and environmental issues arising from brine disposal.
基金supported by the National Natural Science Foundation of China (Grant Nos.52375172,52075093,and 51905089).
文摘The agitated thin film evaporator(ATFE),which is known for its high efficiency,force the material to form a film through the scraping process of a scraper,followed by evaporation and purification.The complex shape of the liquid film inside the evaporator can significantly affect its evaporation capability.This work explores how change in shape of the liquid films affect the evaporation of the materials with non-Newtonian characteristics,achieved by changing the structure of the scraper.Examining the distribution of circumferential temperature,viscosity,and mass transfer of the flat liquid film shows that the film evaporates rapidly in shear-thinning region.Various wavy liquid films are developed by using shear-thinning theory,emphasizing the flow condition in the thinning area and the factors contributing to the exceptional evaporation capability.Further exploration is conducted on the spread patterns of the wavy liquid film and flat liquid film on the evaporation wall throughout the process.It is noted that breaking the wavy liquid film on the evaporating wall during evaporation is challenging due to its film-forming condition.For which the fundamental causes are demonstrated by acquiring the data regarding the flow rate and temperature of the liquid film.The definitive findings of the analysis reveal a significant improvement in the evaporation capability of the wavy liquid film.This enhancement is attributed to increasing the shear-thinning areas and maintaining the overall shape of the film throughout the entire evaporation process.
文摘A theoretical investigation is presented about a double evaporator ejector refrigeration cycle(DEERC).Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by an internal heat exchanger(IHX).The ejector is introduced into the baseline cycle in order to mitigate the throttling process losses and increase the compressor suction pressure.Moreover,the IHX has the structure of a concentric counter-flow type heat exchanger and is intentionally used to ensure that the fluid at the compressor inlet is vapor.To assess accurately the influence of the IHX on the DEERC performance,a mathematical model is derived in the frame of the dominant one-dimensional theory for ejectors.The model also accounts for the friction effect in the ejector mixing section.The equations of this model are solved using an Engineering Equation Solver(EES)for different fluids.These are:R134a as baseline fluid and other environment friendly refrigerants used for comparison,namely,R1234yf,R1234ze,R600,R600a,R290,R717 and R1270.The simulation results show that the DEERC with an IHX can achieve COP(the coefficient of performance)improvements from 5.2 until 10%.
基金support of Chengdu University of Technology(10912-2019KYQD-07545)Sichuan Ministry of Science,Technology Project(22ZDYF2878).
文摘Solar-driven hydrogel evaporator used for water purification demonstrates great potential in seawater desalination and domestic sewage treatment.However,much uncertainty still exists about the most efficient design to obtain cost-effective drinkable water.In this paper,a natural rich biomass Nicandra physalodes(Linn.)Gaertn.polysaccharide was introduced into the polyvinyl alcohol network to control the water distribution during evaporation and build a low-cost hybrid hydrogel solar evaporator with a total material cost of$7.95 m^(−2).The mixed evaporator works stably in a long-span acid–base range(pH 1–14)and salinity range(0–320 g kg^(−1)).Its daily water purification capacity can reach 24.4 kg m^(−2)with a water purification capacity of 3.51 kg m^(−2)h^(−1)under sunlight.This paper provides a new possibility for a highly efficient and cost-effective water desalination system with guaranteed water quality by focusing on the dynamic regulation of water molecules at the evaporation interface.
基金supported by the open foundation of State Key Laboratory of Chemical Engineering (SKL-ChE-18B03)the Municipal Science and Technology Commission of Tianjin (No. 2009ZCKFGX01900)
文摘A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distribution.Water and polyformaldehyde particle(POM)were used as the liquid and solid phases,respectively.The effects of operating parameters such as the amount of added particles,circulating flow rate,and particle size were systematically investigated.The results showed that the addition of the particles increased the pressure drop in the vertical tube bundle.The maximum pressure drop ratios were 18.65%,21.15%,18.00%,and 21.15%within the experimental range of the amount of added particles for POM1,POM2,POM3,and POM4,respectively.The pressure drop ratio basically decreased with the increase in the circulating flow rate but fluctuated with the increase in the amount of added particles and particle size.The difference in pressure drop ratio decreased with the increase in the circulating flow rate.As the amount of added particles increased,the difference in pressure drop ratio fluctuated at low circulating flow rate but basically decreased at high circulating flow rate.The pressure drop in the vertical tube bundle accounted for about 70%of the overall pressure drop in the up-flow heating chamber and was the main component of the overall pressure within the experimental range.Three-dimensional phase diagrams were established to display the variation ranges of the pressure drop and pressure drop ratio in the vertical tube bundle corresponding to the operating parameters.The research results can provide some reference for the application of the fluidized bed heat transfer technology in the industry.
文摘The paper presents the results of development and investigation of a copper miniature loop heat pipe (LHP) with acetone as a working fluid. The device was equipped with a flat evaporator measuring 80 × 42 × 7 mm and vapor and liquid lines with an outside diameter of 3 mm, whose lengths were 145 mm and 175 mm, respectively. The LHP was tested at heat loads from 5 W to 60 W, different orientations in the gravity field and heat-sink temperatures from -40°C to +50°C. It is shown that the LHP retains its efficiency at all testing conditions. It is also mentioned that at a heat-sink temperature of +50°C the device operates in the mode of constant conductivity in the whole range of heat loads, and in this case a minimum thermal resistance of the “heat source-heat sink” system equal to 0.16°C/W is achieved, which is independent of the LHP orientation in the gravity field.
文摘Short path distillation (SPD) is a kind of high vacuum distillation method, which is suitable for the separation of high boiling, heat sensitivity and viscidity products.In this paper,through measuring the phase-averaged velocity distributions with a conditional sampling method of the particle imaging velocimetry (PIV), the liquid flow field that affects the heat and mass transfer of evaporating thin-film in an SPD evaporator is investigated.Measured results show that the flow velocities decrease rapidly apart from the wiper at different wiper velocities, the maximum velocity appears before wipers, and the quicker the wiping, the larger the flow velocity. Meanwhile, the evaluation of numerical calculations is carried out.The measured velocity distributions indicate clearly the effect of the wiper both on the flow field along its moving direction and on the vortices behind the wiper.Simulation data show that the performance of liquid flow field on the heating surface not only agrees with the experimental results well,but also can give further more information, such as the distribution of turbulent kinetic energy.In this study,turbulent kinetic energy mainly distributes before wipers and laminar flow appears far away from the wipers.
基金This project is supported by National Key Technologies R&D Programme,China (No.2001BA501A22).
文摘The evaporator is the main part of a quick-freeze equipment. There are many factors influencing the heat transfer coefficient of an evaporator. The most important factors among them are the fin shape, tube diameter, distance of fin space, frost, and velocity of air flow etc. They mainly influence the thermal efficiency of an evaporator, and therefore its thermal efficiency has direct relationship with the whole efficiency of the quick freeze plant. Evaporators with different structural types have different heat transfer efficiency, in order to obtain high efficiency structure of evaporator, 8 evaporator models with different fin shape, tube diameter and tube arrangement are analyzed and compared. The calculation results show that the integral waved fins, equilateral-triangle arranged small diameter tubes and varying fin-spacing has the highest heat transfer coefficient. The experimental result also shows that the evaporator with this type of structure has better thermal efficiency. The experimental result is in good agreement with the calculation result, it can instruct engineering design for usual designer. A real quick-freeze equipment is designed and put into production. The result shows that, compared with traditional domestic quick-freeze equipments, this equipment decreases by 40% in size and by 20% in energy consumption.
文摘The global energy demand increases with development and population rise. Most electrical power is currently generated by conventional methods from fossil fuels. Despite the high energy demand, the conventional energy resources such as fossil fuels have been declining and harmful combustion byproducts are causing global warming. The Organic Rankine Cycle power plant is a very effective option for utilization of low grade heat sources for power generation. In the Organic Rankine Cycle heat exchangers such as evaporators and condensers are key components that determine its performance. Researches indicated that shell tube heat exchangers are effectively utilized in this cycle. The design of the heat exchanger involves establishing the right flow pattern of the interacting fluids. The performance of these exchangers can be optimized by inserting baffles in the shell to direct the flow of fluid across the tubes on shell side. In this work heat exchangers have been developed to improve heat recovery from geothermal brine for additional power generation. The design involved sizing of heat exchanger (evaporator) using the LMTD method based on an expected heat transfer rate. The heat exchanger of the model power plant was tested in which hot water simulated brine. The results indicated that the heat exchanger is thermally suitable for the evaporator of the model power plant.
文摘Heat transfer of a capillary evaporator in a loop heat pipe was analyzed through 3D numerical simulations to study the effects of the thermal conductivity of the wick, the contact area between the casing and the wick, and the subcooling in the compensation chamber (CC) on the thermal performance of the evaporator. A pore network model with a distribution of pore radii was used to simulate liquid flow in the porous structure of the wick. To obtain high accuracy, fine meshes were used at the boundaries among the casing, the wick, and the grooves. Distributions of temperature, pressure, and mass flow rate were compared for polytetra-fluoroethylene (PTFE) and stainless steel wicks. The thermal conductivity of the wick and the contact area between the casing and the wick significantly impacted thermal performance of the evaporator heat-transfer coefficient and the heat leak to the CC. The 3D analysis provided highly accurate values for the heat leak;in some cases, the heat leaks of PTFE and stainless steel wicks showed little differences. In general, the heat flux is concentrated at the boundaries between the casing, the wick, and the grooves;therefore, thermal performance can be optimized by increasing the length of the boundary.
基金Project supported by the special scientific research funds for doctoral studies
文摘In this paper,the mechanism of operation of an inverse circulating thermosyphon evaporator isproposed.The performance characteristics of this novel evaporator have been studied experimentally andtheoretically,The inverse circulating thermosyphon evaporators have higher heat transfer coefficient and longeroperation period in comparison with ordinary circulating ordinary circulating evaporators.
基金supported by the Key Technologies R&D program of Tianjin,China (16YFZCGX00090)
文摘According to the problem that the selection of traditional PID control parameters is too complicated in evaporator of Organic Rankine Cycle system(ORC),an evaporator PID controller based on BP neural netw ork optimization is designed. Based on the control theory,the model of ORC evaporator is set up. The BP algorithm is used to control the Kp,Kiand Kdparameters of the evaporator PID controller,so that the evaporator temperature can reach the optimal state quickly and steadily. The M ATLAB softw are is used to simulate the traditional PID controller and the BP neural netw ork PID controller. The experimental results show that the Kp,Kiand Kdparameters of the BP neural netw ork PID controller are 0. 5677,0. 2970,and 0. 1353,respectively.Therefore,the evaporator PID controller based on BP neural netw ork optimization not only satisfies the requirements of the system performance,but also has better control parameters than the traditional PID controller.
基金Sponsored by the National Natural Science Foundation of China(Grant No.51276012)
文摘This paper investigated the influence of geometric factors of vapor groove structures on the performance of flat evaporator of a loop heat pipe system. COMSOL multiphysics software was employed to simulate the heat transfer in the evaporator with convex platforms of different shapes,sizes and area ratios(φ)between convex platforms and the heated surface. The maximum temperature and temperature distribution of each model were obtained. The results showed that the decrease of the size of platforms and the increase of φ can lower temperatures and improve temperature distribution homogeneity of the heated surface. Compared with circle and oval platforms,square platforms achieved lower temperature. The results also indicated that φ had the most significant impact on the performance of the evaporator.
文摘Objective To prevent the maldistribution of two phase refrigerant in dry expansion evaporators composed of parallel coils, a distributor is needed to supply refrigerant into the coils. Methods A simplified model of dry expansion evaporator was proposed. The flow and heat transfer in distributing pipes and evaporator coils were simulated with a numerical method. Results The heat flow rate decreases while the refrigerant is distributed unequally to evaporator coils. Conclusion In order to maintain the heat flow rate, larger heat transfer area should be arranged to make up the effect of maldistribution. The larger the discrepancy of mass flow rate is, the more heat transfer area is needed.
基金Project(2016YFC0700100) supported by the National Key R&D Program of ChinaProject(JDJQ20160103) supported by Promotion of the Connotation Development Quota Project of Colleges and Universities-Outstanding Youth of Architectural University,China
文摘The standard k-ε turbulence model and discrete phase model (DPM) were used to simulate the heat and mass transfer in a liquid-desiccant evaporator driven by a heat pump using FLUENT software, and the temperature field and velocity field in the device were obtained. The performance of the liquid-desiccant evaporator was studied as the concentration of the inlet solution varied between 21% and 30% and the pipe wall temperature between 30 and 50 ℃. Results show that the humidification rate and the humidification efficiency increased with the inlet air temperature, the solution flow rate, the solution temperature, and the pipe wall temperature. The humidification rate and humidification efficiency decreased with increasing moisture content in inlet air and the concentration of inlet solution. The humidification rate increased substantially but the humidification efficiency decreased as the inlet air flow rate increased. The error between the simulations and experimental results is acceptable, meaning that our model can provide a theoretical basis for optimizing the performance of a humidifying evaporator.
基金supported by the open foundation of State Key Laboratory of Chemical Engineering(No.SKL-ChE-18B03)by the Municipal Science and Technology Commission of Tianjin,China(No.2009ZCKFGX01900).
文摘A vapor-liquid-solid horizontal circulating fluidized bed evaporation setup was constructed to study the thermal-exchange properties and pressure change.The influences of the operating variables,including the amount of added particles,heat flux,and circulating flow velocity,were systematically inspected using resistance temperature detectors and pressure sensors.The results showed that the heat transfer eff ect was improved with the increase in the amount of added particles,circulating flow velocity,and particle diameter,but decreased with increasing heat flux.The pressure drop fluctuated with the increase in operating parameters,except circulating flow velocity.The enhancing factor reached up to 71.5%.The enhancing fac-tor initially increased and then decreased with the increase in the amount of added particles and circulating flow velocity,fluctuated with increasing particle diameter,and decreased with increasing heat flux.Phase diagrams showing the variation ranges of the operation variables for the enhancing factor were constructed.
文摘The synthetic fuzzy assessing method is usually applied to sensory evaluation. The method has simple and reliable virtue, and it is consistent with objective evaluation results. Using this method, system status of plating solution evaporator is evaluated, and the result is applied to compensate a fuzzy controller. Experimental results have shown the correctness and the validity of the proposed approach.
文摘Direct expansion solar assisted heat pump (DX-SAHP) technology is developed by combining solar energy heat utilization with heat pump energy saving technology. The experimental researches of the DX-SAHP hot water system are conducted in this paper, and overall performance of DX-SAHP is analyzed with three different structures of collectors/evaporators, namely a bare-plate collector, a glass-plate collector and double collectors/evaporators (a bare-plate collector and a glass-plate collector). The influence factors and overall performance are studied, which show that the overall performance of the system is mainly influenced by solar irradiation intensity and the collector area. Comparing with glass-plate collector in similar conditions, bare-plate collector system COP is higher. While increasing collector area is conducive to improve the system COP, but will reduce the collector efficiency and increase the workload of the compressor by comparing the bare-plate collector with double-plate collectors.
文摘Multiple loop heat pipes which have two evaporators and two condensers in one loop are a kind of active heat transfer device. Since they have two evaporators and two condensers, the operating mode also becomes multiple. This work discusses the cases that multiple loop heat pipes were operated with one condenser at high temperature and the other at low temperature. To avoid the high temperature returning liquid and keep the multiple loop heat pipes work properly, the flow regulator which was made of polyethylene was designed, fabricated and applied in this test. The effect of flow regulator was confirmed and analyzed. In the test that large temperature difference existed between two sinks, it can be found according to the result that the flow regulator worked effectively and prevented the high temperature vapor to enter the inlet of common liquid line, which can keep the evaporators and returning liquid to operate at low temperature. With the increment of heat loads and the temperature difference between two sinks, the pressure difference between two condensers became larger and larger. When the pressure difference was larger than the flow regulator’s capillary force, the flow regulator could not work properly because the high temperature vapor began to flow through the flow regulator. According to the test data, the flow regulator can work properly within the sinks’ temperature 0°C/60°C and the two evaporators’ heat load 30/30 W.